• Title/Summary/Keyword: light curing

Search Result 464, Processing Time 0.02 seconds

Microhardness and microleakage of composite resin according to the change of curing light intensity

  • Park, Soo-Man;Shin, Dong-Hoon
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.586.2-586
    • /
    • 2001
  • The selection of a curing light is a multifactorial decision. While each method of polymerization presents unique clinical benefits, the optimal light-curing technique remains to be determined. The objective of this study was to check the difference of micro hardness and microleakage according to various light intensity (50, 100, 200, 300, 400, 600 ㎽/$\textrm{cm}^2$) and curing time (10, 20, 40 seconds). A3 color of two composite resin, hybrid type DenFil and submicron type Esthet X were tested.(중략)

  • PDF

Effect of light source on depth of cure and polymerization shrinkage of composites

  • Na, Joon-Sok;Oh, Won-Mann;Hwang, In-Nam
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.578.1-578
    • /
    • 2001
  • The aim of this study was to evaluate the efficiency of the recently introduced light curing units to polymerize a light curing resin composite. Four light curing units XL 3000, Optilux 500 for halogen light source, Apollo 95E for plasma arc and Easy cure for LED (blue-light Emitting Diode) were evaluated. Radiometer was used for measure the light intensity.(omitted)

  • PDF

A Study on the Accuracy of the record base of the Complete Denture to the Master Cast according to Kinds of Resin and Polymerization Method

  • Choi, Hyo-Jin;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.310-320
    • /
    • 2000
  • Statement of the problem. The record base in fabricating procedures of the complete denture, as a temporary form for reproducing denture base, is used to record upper and lower jaw relation and to align artificial teeth and try-in it in the mouth. The accuracy of jaw relation record is affected by the accuracy, stiffness and stability of the record base. So, the accuracy of record base is the most important requirements of jaw relation records. Purpose of study. The purpose of this study was to evaluate the gap that occurred over the palatal area of a maxillary record base fabricated with autopolymerizing resin and light-curing resin. Methods/material. The maxillary record bases were fabricated out of autopolymerizing resin that is used the most frequently in clinics and light-curing resin that attracts special attention for its several merits. The light-curing resin was made by two kinds of polymerization methods, which are one step curing method and multiple step curing method. All record bases were cut in certain positions of the master cast 1 hour and 1 day later after fabrication and the accuracy of the master cast was measured and analyzed with a microscope. Results. A pattern of gap formation between the record base and the maxillary cast was observed in all specimens. According to kinds of resins, autopolymerizing resin was significantly more accurate than light-curing resin. There was no statistical difference according to time lapse, and in all three groups, the maximum discrepancy occurred at the posterior border in the mid-palatal region. Conclusion. The autopolymerizing resin is better than light-curing resin, and multiple step curing method is more accurate than one step curing method when using light-curing resin.

  • PDF

Degree of conversion of two dual-cured resin cements light-irradiated through zirconia ceramic disks

  • Kim, Min-Jeong;Kim, Kyo-Han;Kim, Young-Kyung;Kwon, Tae-Yub
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.464-470
    • /
    • 2013
  • PURPOSE. The aim of this Fourier transform infrared (FTIR) spectroscopic study was to measure the degree of conversion (DC) of dual-cured resin cements light-irradiated through zirconia ceramic disks with different thicknesses using various light-curing methods. MATERIALS AND METHODS. Zirconia ceramic disks (KT12) with three different thicknesses (1.0, 2.0, and 4.0 mm) were prepared. The light transmittance of the disks was measured using ultraviolet visible near-infrared spectroscopy. Four different light-curing protocols were used by combining two curing light modes (Elipar TriLight (standard mode) and bluephase G2 (high power mode)) with light-exposure times of 40 and 120 seconds. The DCs of the two dual-cured resin cements (Duo-Link and Panavia F2.0) light-irradiated through the disks was analyzed at three time intervals (3, 7, and 10 minutes) by FTIR spectroscopy. The data was analyzed using repeated measures ANOVA (${\alpha}$=.05).Two-way ANOVA and Tukey post hoc test were used to analyze the 10 minute DC results. RESULTS. The 1.0 mm thick disk exhibited low light transmittance (<25%), and the transmittance decreased considerably with increasing disk thickness. All groups exhibited significantly higher 10 minute DC values than the 3 or 7 minute values (P<.05), but some exceptions were observed in Duo-Link. Two-way ANOVA revealed that the influence of the zirconia disk thickness on the 10 minute DC was dependent on the light-curing methods (P<.001). This finding was still valid even at 4.0 mm thickness, where substantial light attenuation took place. CONCLUSION. The curing of the dual-cured resin cements was affected significantly by the light-curing technique, even though the additional chemical polymerization mechanism worked effectively.

A CLINICAL STUDY ON THE MAINTENANCE OF LIGHT INTENSITY OF VISIBLE-LIGHT CURING MACHINES FOR THE POLYMERIZATION OF COMPOSITE RESINS (복합레진 중합용 가시광선 광중합기의 적정 광강도 유지를 위한 임상적 고찰)

  • Lee, Dong-Soo;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.363-368
    • /
    • 2001
  • It is well known that numerous factors influence the light output of curing units, but many dentists are un aware that the output of their curing lights are inadequate. This study was conducted to evaluate the light in tensity of visible-light curing units in some private dental clinics and hospital dental clinics. In order to determine the maximum light intensity of the curing units, lamps, filters and fiber optic bundles, they were replaced with new ones and light intensity was remeasured. Light intensity was measured by employing a digital radiometer (EFOS model #8000, USA). Light intensity ranged in $29\sim866mW/cm^2$ (below $150mW/cm^2$ ; 17.8%, $150\sim300mW/cm^2$ : 46.6%, above $300mW/cm^2$ ; 35.6%). The replacement of the components increased the light intensity, with maximum increases of 94.8% for lamps, 82.3% for filters, 200.8% for fiber optics and 361.5% for all three parts. According to the manufacturer of radiometer, curing light is considered as unsuitable for use with a reading of above $300mW/cm^2$ by the radiometer. Applying these criteria to the present study, 64.4% of the curing units required repair or replacement. The results of this study indicated that the light intensities of the curing units used in dental practice were lower than optimum level.

  • PDF

MECHANICAL PROPERTIES AND MICROLEAKAGE OF COMPOSITE RESIN MATERIALS CURED BY VARIABLE LIGHT INTENSITIES (가변 광도에 따른 복합레진의 기계적 물성 및 변연누출도 변화)

  • Han, Seung-Ryul;Min, Kyung-San;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.134-145
    • /
    • 2003
  • Mechanical properties and microleakage of two composites [conventional hybrid type DenFil (VERICOM Co., Anyang, Korea) / micro matrix hybrid type Esthet X (Dentsply Caulk, Milford, DE, U.S.A.)] were evaluated to assess whether variable light intensity curing is better than conventional curing technique. Curing was done for 40 seconds in two ways of 2 step soft-start technique and 5 step ramping technique. Three kinds of light intensities of 50, 100, $200{\;}mW/\textrm{cm}^2$ were initially used for 10, 20, 30 seconds each and the maximum intensity of $600 {\;}mW/\textrm{cm}^2$ was used for the rest of curing time in a soft-start curing tech nique. In a ramping technique, curing was done with the same initial intensities and the light intensity was increased 5 times with the same rate to the maximum intensity of $600{\;}mW/\textrm{cm}^2$. After determining conditions that showed no different mechanical properties with conventional technique, Esthet X composite was filled in a class V cavity, which dimension was $4{\times}3{\times}1.5{\;}mm$ and cured under those conditions. Microleakage was evaluated in two ways of dye penetration and maximum gap estimation through SEM observation. ANOVA and Spearman's rho test were used to confirm any statistical significance among groups. The results were as follows : 1 Several curing conditions of variable light intensities resulted in the similar mechanical properties with a conventional continuous curing technique, except conditions that start curing with an initial light intensity of $50{\;}mW/\textrm{cm}^2$. 2. Conventional and ramping techniques were better than soft-start technique in mechanical properties of microhardness and compressive strength. 3. Soft-start group that started curing with an initial light intensity of $100{\;}mW/\textrm{cm}^2$ for 10 seconds showed the least dye penetration. Soft-start group that started curing with an initial light intensity of $200{\;}mW/\textrm{cm}^2$ for 10 seconds showed the smallest marginal gap, if there was no difference among groups. 4. Soft-start technique resulted in better dye-proof margin than conventional technique(p=0.014) and ramping technique(p = 0.002). 5. There was a very low relationship(p=0.157) between the methods of dye penetration and marginal gap determination through SEM evaluation. From the results of this study, it was revealed that ramping technique would be better than conventional technique in mechanical properties, however, soft-start technique might be better than conventional one in microleakage. It was concluded that much endeavor should be made to find out the curing conditions, which have advantages of both aspects or to solve these kinds of problems through a novel idea of polymerization.

THE EFFECTS OF WAVELENGTH AND INTENSITY OF VISIBLE LIGHT ON THE CURING OF VISIBLE LIGHT CURED COMPOSITE RESIN (가시광선의 파장과 광도가 광중합형 복합레진의 경화에 미치는 영향)

  • Lee, Chae-Gyeong;Hur, Bok
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.149-159
    • /
    • 1989
  • The purpose of this study was to assess the effects of wavelength and intensity of light curing units on the curing of composite resin. The wavelength and intensity of nine units were evaluated with Optical Multichannel Analyzer and Radiometer. Two-part split stainless steel mold with a cylindrical hole-3.0mm in diameter, 6.0mm in hgieht-was prepared. After placing a Mylar strip between two parts, 100 specimens were made by inserting each of four composite resins into the mold and irradiating for 20 seconds with five light units alternatively. The curing depths were measured by scraping method and evaluated by two-way ANOVA. And Vicker's hardness measurements were made on the longitudinally sectioned surface at 0.5mm interval. The results were as follows: 1. Visilux 2 showed a narrow spectral band within the effective wavelength in initiating polymerization and the highest intensity. Translux showed the diffuse spectrum of wavelength and the lower light intensity. 2. Visilux 2 showed the highest curing effect in any composite resin and then followed by Optilux, Efos 35, Heliomat and Translux. (p < 0.01) 3. Durafill showed the deepest curing depth in any light unit and then followed by Bisfil M, Silux and Heliosit. (p < 0.01). 4. Maximum hardness values showed 0.1mm and 0.5mm under top surface and then gradually decreased with depth.

  • PDF

Evaluation of High-power Light Emitting Diode Curing Light on Sealant Polymerization (고출력 발광 다이오드 광중합기의 치면열구전색제 중합능 평가)

  • Park, Youngjun;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.57-63
    • /
    • 2019
  • This study aimed to determine whether the curing times of Xtra Power and High Power modes of high-power light emitting diode (LED) curing light are sufficient for polymerization of resin sealants. The specimens were prepared and their microhardness values were measured and compared with those of specimens polymerized under conventional LED curing light. The filled sealant polymerized for 8 seconds in the High Power mode and for 3 seconds in the Xtra Power mode showed significantly lower microhardness than the control specimen (p = 0.000). The unfilled sealant polymerized for 8, 12 seconds in the High Power mode and for 6 seconds in the Xtra Power mode showed significantly lower microhardness than the control specimen (p = 0.000). The results of this study suggest that the short curing time with the Xtra Power and High Power modes of highpower LED curing light are not sufficient for adequate polymerization of sealants under specific conditions, taking into account the curing times and the type of sealant.

Effect of infection control barrier thickness on light curing units (감염 조절용 차단막의 두께가 광중합기의 중합광에 미치는 영향)

  • Chang, Hoon-Sang;Lee, Seok-Ryun;Hong, Sung-Ok;Ryu, Hyun-Wook;Song, Chang-Kyu;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.368-373
    • /
    • 2010
  • Objectives: This study investigated the effect of infection control barrier thickness on power density, wavelength, and light diffusion of light curing units. Materials and Methods: Infection control barrier (Cleanwrap) in one-fold, two-fold, four-fold, and eightfold, and a halogen light curing unit (Optilux 360) and a light emitting diode (LED) light curing unit (Elipar FreeLight 2) were used in this study. Power density of light curing units with infection control barriers covering the fiberoptic bundle was measured with a hand held dental radiometer (Cure Rite). Wavelength of light curing units fixed on a custom made optical breadboard was measured with a portable spectroradiometer (CS-1000). Light diffusion of light curing units was photographed with DSLR (Nikon D70s) as above. Results: Power density decreased significantly as the layer thickness of the infection control barrier increased, except the one-fold and two-fold in halogen light curing unit. Especially, when the barrier was four-fold and more in the halogen light curing unit, the decrease of power density was more prominent. The wavelength of light curing units was not affected by the barriers and almost no change was detected in the peak wavelength. Light diffusion of LED light curing unit was not affected by barriers, however, halogen light curing unit showed decrease in light diffusion angle when the barrier was four-fold and statistically different decrease when the barrier was eight-fold (p < 0.05). Conclusions: It could be assumed that the infection control barriers should be used as two-fold rather than one-fold to prevent tearing of the barriers and subsequent cross contamination between the patients.

A STUDY ON THE TENSILE BOND STRENGTH TO TOOTH STRUCTURE OF TOOTH COLORED MATERIALS ACCORDING TO FILLING METHODS AND LIGHT CURING UNITS (심미수복재의 수복방법과 광조사기기에 따른 치질과의 인장결합강도에 관한 연구)

  • Hwang, Ho-Keel;Kim, Young-Kwan;Oh, Haeng-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.652-663
    • /
    • 1996
  • The purpose of this study was to evaluate the tensile bond strength to tooth structure of composite resin and glass ionomer cement according to filling methods and light curing units. In this study, two class V cavities were prepared on the buccal surface of each tooth of 140 extracted human molars, and they were randomly assigned into 3 experimental groups with 40 teeth and control group with 20 teeth. And then, each experimental groups subdivided into 2 groups(A,B) according to light curing units. The cavities of each group were filled with the CLEARFIL FII self curing resin(Control Group), Z-100 light curing resin(Group 1), Vitremer$^{TM}$ light curing glass ionomer cement(Group 2) and Z-100 light curing resin over the Vitrebond$^{TM}$ liner(Group 3). And subdivided A Group used Argon Laser(SPECTRUM$^{TM}$, U.S.A.), B Group used XL 1,000 curing light (3M, U.S.A.). The specimens underwent temperature changed from $5^{\circ}C$ to $55^{\circ}C$ five hundred times. After thermocycling, specimens were stored in 100% relative humidity at $37^{\circ}C$ for 24 hours. And then, the tensile bond strength of specimens were calculated with Universal Testing Machine(AGS-100A, Japan). The results were as follows : 1. Among the experimental groups, the group 2-B showed the highest tensile bond strength ($18.89{\pm}7.80$) and the group 1-A showed the lowest tensile bond strength ($11.68{\pm}2.28$). There was significant difference between group 2-B and group 1-A(p<0.01). 2. Between the light curing units, the XL 1,000 unit showed higher tensile bond strength ($16.63{\pm}3.20$) than that of the Argon Laser unit ($13.73{\pm}2.30$). There was significant difference between XL 1,000 and Argon Laser(p<0.01). 3. About filling methods and materials, the group 2 showed the highest tensile bond strength ($17.56{\pm}1.89$) and the group 1 showed the lowest tensile bond strength($13.03{\pm}1.90$). There was significant difference between group 2 and group 1,3(p<0.01). In conclusion, the results showed that the glass-ionomer cement that cured by XL 1,000 light curing unit demonstrated significantly higher tensile bond strength than other curing unit and filling methods.

  • PDF