• Title/Summary/Keyword: light curing

Search Result 466, Processing Time 0.025 seconds

CLINICAL APPLICATION OF ARGON LASER IN PEDIATRIC DENTISTRY (아르곤 레이저의 소아치과에서의 임상적 적용)

  • Lee, Mi-Na;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.139-147
    • /
    • 1997
  • Argon laser used in this case report, is special in having two wavelength of 488, 514nm blue-green visible light spectrum. Blue light is used for composite resin polymerization and caries detection. Green light is used for soft tissue surgery and coagulation. Maximum absorption of this laser light occurs in red pigmentation such as hemoglobin. The argon laser may be well-suited for selective destruction of blood clots and hemangioma with minimal damage to adjacent tissues. Argon laser light penetrates tissue to the 1 mm depth, so its thermal intensity is lower than $CO_2$ laser light. Also, due to its short wavelength it can be focused in a small spot and even single gene can be excised by this laser and microscopy. After applicating argon laser to 4 patient for surgical procedure and to 1 patient for curing the composite resin, following results were obtained. 1. Improved visibility were gained due to hemostasis and no specific technique were needed according to easy recontouring of the tissue. 2. Ability to use by contact mode, tactile sense was superior but tissue dragability and accumulation of tissue on the tip needed sweeping motion. 3. Additive local anesthetic procedure was needed. 4. No suture and less curing time reduced chair time, this made argon laser available in pediatric dentistry.

  • PDF

AN EXPERIMENTAL STUDY ON THE SHEAR BOND STRENGTH OF THE COMPOSITE RESIN WITH THE VARIOUS SURFACE TREATMENTS OF LIGHT - CURED GLASS IONOMER CEMENTS (광중합형 Glass Ionomer Cement의 표면처리 방법에 따른 복합레진과의 결합력에 관한 실험적 연구)

  • Yong, Seung-Hee;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.421-430
    • /
    • 1992
  • The purpose of this study was to evaluate the bond strength between the composite resin and light - cured glass ionomer cement base / liners treated by the several methods. The light - cured glass ionomer cement(Vitrebond / Cavalite) were injected into cavites prepared in acrylic plates. One hundred and twenty specimens were uniformly prepared and devided into 3 groups. For the first group, primer was not applied to glass ionomer cement. For the second group, no application of primer was undertaken and light - curing procedure to uncured glass ionomer cement surface which was covered by bonding agent was undertaken. After bonding composite resin to light - cured glass ionomer surface, the specimens, were stored in $37^{\circ}C$, 100% humidity for 1 hour. The following results were obtained : 1. The omission of application of a primer did not produce a significantly poorer bond strength. 2. Light - curing technique to uncured glass ionomer cement which was covered by bonding agent did not produce a significantly poorer bonding strength. 3. The bond strength of Cavalite to composite resin was significantly higher than that of Vitrebond. 4. There was no significant difference between two different types of composite materials(Silux-Plus / Herculite XR) when it was applied to bond to glass ionomer cement.

  • PDF

THE EFFECT OF INTERMITTENT COMPOSITE CURING ON MARGINAL ADAPTATION (복합레진의 간헐적 광중합 방법이 변연적합도에 미치는 영향)

  • Yun, Yong-Hwan;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.248-259
    • /
    • 2007
  • The aim of this research was to study the effect of intermittent polymerization on marginal adaptation by comparing the marginal adaptation of intermittently polymerized composite to that of continuously polymerized composite. The materials used for this study were Pyramid (Bisco Inc., Schaumburg, U.S.A.) and Heliomolar (Ivoclar Vivadent, Liechtenstein) . The experiment was carried out in class II MOD cavities prepared in 48 extracted human maxillary premolars. The samples were divided into 4 groups by light curing method: group 1- continuous curing (60s light on with no light off), group 2-intermittent curing (cycles of 3s with 2s light on & 1s light off for 90s); group 3- intermittent curing (cycles of 2s with 1s light on & 1s light off for 120s); group 4- intermittent curing (cycles of 3s with 1s light on & 2s light off for 180s). Consequently the total amount of light energy radiated was same in all the groups. Each specimen went through thermo-mechanical loading (TML) which consisted of mechanical loading (720,000 cycles, 5.0 kg) with a speed of 120 rpm for 100hours and thermocycling (6000 thermocycles of alternating water of $50^{\circ}C$ and $55^{\circ}C$). The continuous margin (CM) (%) of the total margin and regional margins, occlusal enamel (OE), vertical enamel (VE), and cervical enamel (CE) was measured before and after TML under a $\times200$ digital light microscope. Three-way ANOVA and Duncan's Multiple Range Test was performed at 95% level of confidence to test the effect of 3 variables on CM (%) of the total margin: light curing conditions, composite materials and effect of TML. In each group, One-way ANOVA and Duncan's Multiple Range Test was additionally performed to compare CM (%) of regions (OE, VE CE). The results indicated that all the three variables were statistically significant (p < 0.05). Before TML, in groups using Pyramid, groups 3 and 4 showed higher CM (%) than groups 1 and 2, and in groups using Heliomolar. groups 3 and 4 showed higher CM (%) than group 1 (p < 0.05). After TML, in both Pyramid and Heliomo)ar groups, group 3 showed higher CM (%) than group 1 (p < 0.05) CM (%) of the regions are significantly different in each group (p < 0.05). Before TML, no statistical difference was found between groups within the VE and CE region. In the OE region, group 4 of Pyramid showed higher CM (%) than group 2, and groups 2 and 4 of Heliomolar showed higher CM (%) than group 1 (p < 0.05). After TML, no statistical difference was found among groups within the VE and CE region. In the OE region, group 3 of Pyramid showed higher CM (%) than groups 1 and 2, and groups 2,3 and 4 of Heliomolar showed higher CM (%) than group 1 (p < 0.05). It was concluded that intermittent polymerization may be effective in reducing marginal gap formation.

Physical Properties of UV curable coating on plastic (플라스틱용 자외선경화형 도료의 물성연구)

  • 김일재;문명준
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.16 no.3
    • /
    • pp.61-80
    • /
    • 1998
  • To investigate in influence of photosensitizer used with benzophenone(BP) in the curing rate and physical properties of UV curable hard coating on plastic, we prepared UV curable clear and pigmented coatings with DEA, DMA, NPM and TEA as photosensitizer, respectively. The curing rate calculated from the decrease of the absorbance of acrylic double bond measured by FT-IR spectroscopy increased s follows; DEA>DMA>NPM>TEA. this order could be explained by the reactivity of diethylamino group of DEA and the ease of formation of activated complex between BP and photosensitizer during the curing process. In UV curable pigmented coatings, the order of curing rate increased as follows; DEA>DMA>TEA>NPM. It was found that the curing rate of the pigmented coating can be increased by light scattering of TiO$_2$. The hardness of coating film cured by photosensitization of DEA and DMA is higher than other photosensitizers due to the crosslinking reaction of DEA and DMA radical bound to polymer backbone.

  • PDF

Thermal Curing Property of Silicone Encapsulant Containing Quantum Dot Surrounded by Various Types of Ligands

  • Lee, Chae Sung;Kim, BeomJong;Jeon, Seongun;Han, Cheul Jong;Hong, Sung-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3787-3789
    • /
    • 2013
  • In this study, the silicone thermal curing degree of the silicone-encapsulated quantum dot light emission diode was measured using the various types of chemical ligands around quantum dot. It was confirmed that the trioctyl phosphin oxide (TOPO) ligand around the quantum dot was responsible for dispersion of the quantum dot in silicone encapsulant and decline of the thermal curing degree of the silicone encapsulant. Also, it was confirmed that the thermal curing degree of silicone encapsulants containing the steric acid (SA) and the dodecanoic acid (DA) ligands were higher than the one of TOPO ligand.

Durable Press Finish of Cotton via Dual Curing Using UV Light and Heat

  • Jang, Jinho;Yoon, Ki-Cheol;Ko, Sohk-Won
    • Fibers and Polymers
    • /
    • v.2 no.4
    • /
    • pp.184-189
    • /
    • 2001
  • Continuous photografting/crosslinking of polyethyleneglycol dimethacrylate oligomers onto cotton using a water-soluble benzophenone photoinitiator was investigated. Photografting increased with increasing irradiation dose, oligomer concentration and photoinitiator concentration. Maximum grafting efficiency of DM 400 and 600 were 83% and 79%, respectively. the photografting increased the wrinkle resistance of cotton implying surface crosslinking of cotton. bothsurface crosslinking and bulk crosslinking of cotton were accomplished via dual curing of a mixed formulation containing both a thermally curable component (BTCCA/SHP) and a UV-curable component. The wrinkle resistance of the crosslinked cotton was found to be higher when cured by thermal curing due to the facile post-polymerization of the UV active component. The presence of crosslinks in the dually crosslinked cotton was verified with FT-IR and thermogravimetric analysis.

  • PDF

How does duration of curing affect the radiopacity of dental materials?

  • Bejeh Mir, Arash Poorsattar;Bejeh Mir, Morvarid Poorsattar
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.89-93
    • /
    • 2012
  • Purpose : Clinicians commonly encounter cases in which it is difficult to determine whether adjacent radiopacities are normal or pathologic. The ideal radiopacity of composite resin is equal to or higher than that of the same thickness of aluminum. We aimed to investigate the possible effects of different curing times on the post-24-hour radiopacity of composite resins on digital radiographs. Materials and Methods : One mm thick samples of Filtek P60 and Clearfil resin composites were prepared and cured with three regimens of continuous 400 mW/$cm^2$ irradiance for 10, 20 and 30 seconds. Along with a 12-step aluminum step wedge, digital radiographs were captured and the radiopacities were transformed to the equivalent aluminum thicknesses. Data were compared by a general linear model and repeated-measures of ANOVA. Results : Overall, the calculated equivalent aluminum thicknesses of composite resins were increased significantly by doubling and tripling the curing times (F(2,8)=8.94, p=0.002). Notably, Bonferroni post-hoc tests confirmed that the radiopacity of the cured Filtek P60 was significantly higher at 30 seconds compared with 10 seconds (p=0.04). Although the higher radiopacity was observed by increasing the time, other comparisons showed no statistical significance (p>0.05). Conclusion : These results supported the hypothesis that the radiopacity of resin composites might be related to the duration of light curing. In addition to the current standards for radiopacity of digital images, defining a standard protocol for curing of dental materials should be considered, and it is suggested that they should be added to the current requirements for dental material.

Power density of various light curing units through resin inlays with modified layer thickness

  • Hong, Sung-Ok;Oh, Yong-Hui;Min, Jeong-Bum;Kim, Jin-Woo;Lee, Bin-Na;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann;Chang, Hoon-Sang
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.130-135
    • /
    • 2012
  • Objectives: The purpose of this study was to enhance curing light penetration through resin inlays by modifying the thicknesses of the dentin, enamel, and translucent layers. Materials and Methods: To investigate the layer dominantly affecting the power density of light curing units, resin wafers of each layer with 0.5 mm thickness were prepared and power density through resin wafers was measured with a dental radiometer (Cure Rite, Kerr). The dentin layer, which had the dominant effect on power density reduction, was decreased in thickness from 0.5 to 0.1 mm while thickness of the enamel layer was kept unchanged at 0.5 mm and thickness of the translucent layer was increased from 0.5 to 0.9 mm and vice versa, in order to maintain the total thickness of 1.5 mm of the resin inlay. Power density of various light curing units through resin inlays was measured. Results: Power density measured through 0.5 mm resin wafers decreased more significantly with the dentin layer than with the enamel and translucent layers (p < 0.05). Power density through 1.5 mm resin inlays increased when the dentin layer thickness was reduced and the enamel or translucent layer thickness was increased. The highest power density was recorded with dentin layer thickness of 0.1 mm and increased translucent layer thickness in all light curing units. Conclusions: To enhance the power density through resin inlays, reducing the dentin layer thickness and increasing the translucent layer thickness would be recommendable when fabricating resin inlays.

Chemical Properties of Light-weight Foamed Concrete Using WCP in Hydrothermal Reaction Condition (수열반응 조건에서 폐콘크리트 미분말을 사용한 경량기포콘크리트의 화학적 특성)

  • Park, Hyo-Jin;Lee, Kyung-Hyun;Kang, Cheol;Jeong, Ji-Yong;Lee, Dae-Geun;Kim, Jin-Man
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.375-376
    • /
    • 2010
  • This study is shown the chemical characteristics by SEM and XRD for the Light-weight Foamed Concrete according to replacement ratio of WCP and the autoclave curing time. From the SEM of the Light-weight Foamed Concrete after hydrothermal raction, regardless of replacement ratio of WCP and the autoclave curing time, forms the crystal hydrates having various shapes such as board and fiber etc is generated. From the XRD, it seems that the tobermorite hydrate is originated from crystalized quartz.

  • PDF

THE CHANGE IN SURFACE CONVERSION AND DISCOLORATION IN DENTAL RESTORATIVE COMPOSITE RESIN UNDER DIFFERENT POLISHING METHODS; THE CORRELATION BETWEEN SURFACE CONVERSION AND SURFACE DISCOLORATION (수복용복합레진의 표면처리방법에 따른 표면중합률 및 변색정도의 변화와 그 상관관계에 대한 연구)

  • Park, Sung-Ho;Noh, Byung-Duk;Kim, Mo-Ran;Ahn, Hyun-Jung
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.482-486
    • /
    • 2000
  • The purpose of the present study was first, to evaluate the relationship between composite surface conversion and surface discoloration, second, to know if there was difference in surface discoloration between celluloid-strip-finished composite surface and polished surface. In addition, the discoloration of composite surface was also evaluated with visual inspection or digital camera with high resolution monitor, Z100, Tetric Ceram, Spectrum, and Aelitfil were used. The composite surfaces were celluloid-strip finished (group 1), polished (group 2), celluloid-strip finished under nitrogen gas purging (group 3) or only light cured without finishing or polishing under nitrogen gas purging (group 4). The microhardness of each samples were also measured in each group. The samples of each group were also divided into 4 subgroup whether they were immediately placed in disclosing solution (0.2% Elythrosin, pH 7.0) (subgroup1), 1 day after light curing(subgroup 2), 3day after light curing(subgroup 3) or 7 day after light curing(subgroup 4). The computer controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$). The amounts of color difference were compared. The results were as follows; 1. There was no difference in discoloration between celluloid strip finished composite surface and polished surface. 2. The samples discolored more when they were placed in disclosing solution immediately after polymerization than other groups. 3. When the samples were light cured under nitrogen gas purging and without polishing process, they discolored more than other groups even though they showed higher micro hardness. 4. With visual inspection or digital camera, only a limited information was available in detecting composite surface discoloration.

  • PDF