• Title/Summary/Keyword: lifting angle

Search Result 91, Processing Time 0.027 seconds

Evaluation of Seat Pan Inclination During Sit-to-stand for Development of Elderly Lifting-chair

  • Hong, Jae-Soo;Kim, Jong-Hyun;Chun, Keyoung-Jin
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.357-363
    • /
    • 2011
  • Objective: The aim of this study is to set the design direction of the lift chair's tilting seat for development. Background: Great attention has been shown to the development of senior friendly product, because of increasing elderly population rapidly in Korea. Therefore, we need to study on sit-to-stand(STS) motion of elderly systematically for developing lift chair that is one of senior friendly products. Method: In this study, we analyzed joint moment(knee, hip) and muscle activity (Erector spinae, Rectus femoris, Vastus lateralis) on STS motion of elderly(female, 60~70: 7) and young people(female, 20~30: 7) using 3 dimension motion capture camera, force plate, wireless EMG. Results: The results of muscle activity showed a similar trend but the results of joint moment were a lot of differences between the young and the elderly. Conclusion: The results of knee joint moment suggest the angle(10~30deg)-adjustable seat that can be better than to find the optimal seat's angle. Application: The method and results of this study are expected to develop senior friendly product and verification as well as be available to various application.

A study on the size of product shear surface in shearing process (전단 가공에서 제품 전단면의 크기에 변화에 관한 연구)

  • Son, Jong-Min;Lee, Hui-Ju;Cho, Gi-Heum;Shin, Seong-Eun;Kim, Sei-Whan;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.11 no.1
    • /
    • pp.26-29
    • /
    • 2017
  • Burrs generated during shear forming such as notching and piercing may cause lifting during product assembly, which may deteriorate the productivity and quality of products. In this study, various shear angles and variable clearances between the punch and the die were applied in experimental notching tests to investigate the shear fracture surface and the burr height due to various conditions. The experimental results show that the clearance has the greatest effect on shear and fracture surfaces. It is considered that the height of the shear section increases slightly as the shear angle increases.

EMG Measurement for Lower Leg of Golf Caddies (골프 진행보조요원의 하지근 피로도)

  • Kim, Soon-Lae;Kwon, Young Gook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.9 no.1
    • /
    • pp.49-55
    • /
    • 2000
  • When standing, walking, or running for extended periods of time, fatigue occurs in the legs. Although there are many ways, to release tense or fatigued leg muscles, in the case that there is insufficient time to relax, an easy way to release leg fatigue is using an inclined step (about 3 minutes). This method was more effective than performing stretching exercises as studied. An experiment was conducted on a golf course in the Kangwon province in Korea. Subjects were chosen randomly and consisted of 5 females and 4 males golf caddies. Their main tasks consisted of pulling golf carts to the bottom of a hill for 8 to 10 hours and sometimes lifting and lowering golf clubs during the duration of one day. EMG was measured after work and after using the previously mentioned inclined Steps for the lower legs using ME3000P. This study investigated the types of inclined Steps which would be most effective and appropriate for golf caddies, whether sex difference had any influence existed between male and female workers. The results showed that a step with a $20^{\circ}$ angle was most effective for males and a step with a $25^{\circ}$ angle was most effective for females. Females showed faster recovery from fatigue than males. However, there were no statistical significance between males and females.

  • PDF

Hinge Mechanism Design of Smooth-Lift-Unit for Flat Panel Display (평판디스플레이용 유연승강유니트의 힌지기구 설계)

  • Cheong, Seon-Hwan;Choi, Seong-Dae;Cho, Gyu-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.3
    • /
    • pp.85-91
    • /
    • 2007
  • This study was carried out to minimize the lifting force of a two hinge type stand mechanism. This unit is designed for the display devices in order to enhance the ergonomics for effective height adjustment and maintenance at any preferred position. The unit will be very useful for the mechanism fabricated with a coil spring and disc springs as a torque generator. The maximum and the minimum torque value should be calculated initially for the smooth lift. And the reasonable torque distribution is necessary to prevent any auto lift and auto dropping at any position because the torque generated by coil spring is more sensitive than disc spring in tilting the position. Therefore, the analysis of the coil spring is requisite to issue the specific torque value depending on the distorted angle with securing reliability of a long time storage condition. After the theoretical torque value was calculated, the evaluation was carried out by making a proto-type sample, then distorted angle was updated by experiment. The result of this study can readily be applied to various units for the optimization of the smooth lift.

  • PDF

A Study on Adaptive Design of Mechanical Part for Smooth Lift (유연 승강기용 부품의 적용 설계에 관한 연구)

  • 최성대;정선환;조규열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1454-1457
    • /
    • 2003
  • This study was carried out to minimize the lifting force of a two hinge type stand mechanism. This unit is designed for the display devices in order to enhance the ergonomics for effective height adjustment and maintenance at any preferred position. The unit will be very useful for the mechanism fabricated with a coil spring and disc springs as a torque generator. The maximum and the minimum torque value should be calculated initially for the smooth lift. And the reasonable torque distribution is necessary to prevent any AUTO LIFT and AUTO Drooping at any position because the torque generated by coil spring is more sensitive than disc spring in tilting the position. Therefore, the analysis of the coil spring is requisite to issue the specific torque value depending on the distorted angle with securing reliability of a long time storage condition. After the theoretical torque value was calculated, the evaluation was carried out by making a proto-type sample, then distorted angle was updated by experiment. The result of this study can readily be applied to various units for the optimization of the smooth lift.

  • PDF

Inverse analysis of erection process for prismatic tensegrity structures with redundant cables

  • Pei Zhang;Huiting Xiong;Jingjing Yang;Jiayan Liu
    • Steel and Composite Structures
    • /
    • v.49 no.2
    • /
    • pp.125-141
    • /
    • 2023
  • Firstly, a new kind of prismatic tensegrity structures with redundant cables is defined, the topology, geometry and forming conditions of which are introduced further. The development of its mechanical properties including self-stress states and structural stiffness with the increment of the twist angle is also investigated carefully. Combined with the topology of this kind of structures, a reasonable erection scheme is proposed, in which some temporary lifting points need to be set and two groups of vertical cables are tensioned in batches. Then, a simplified dynamic relaxation method is employed to track the erection process inversely, which aims to predict each intermediate equilibrium state during the construction, and give the key structural parameters that can effectively guide the construction. The removal of the active cables, the relaxation or tension of the passive cables are simulated by controlling their axial stiffness, so that the structural composition as well as the serial numbers of the elements always keep invariant regardless of the withdrawal of the slack cables. The whole analysis process is clear in concept, simple to implement and easy to popularize. Finally, several examples are given to verify the practicability and effectiveness of the proposed method further.

A Development of Wind Tunnel Test System for Synthetic Jet Actuator with Embedded Web Server (임베디드 웹서버를 이용한 Synthetic Jet Actuator의 풍동실험장치 개발)

  • Jung Gyu Hong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.5 s.236
    • /
    • pp.639-646
    • /
    • 2005
  • As the internet communication is prevalent in recent years, it becomes quite possible to monitor and control some mechanical plants from the remote place through the TCP/IP communication. Such a concept is expected to be applied to many industrial systems fur easy maintenance and trouble shooting as well as various kinds of expensive test equipments fo. sharing. Synthetic jet actuate.(SJA) is a kind of high-lifting device to prevent flow separation at high angle of attack and its use for flow control has received a great amount of attention. In this research, remote control and data monitoring system for SJA wind tunnel test is implemented by TCP/IP communication with DSP as a embedded web server. From the tests performed with embedded server, it showed the possibility of reliable remote control system design utilizing the internet communication.

Study on the Design of Cam-type Transfer Unit (대형 캠 타입 이송장치의 설계에 관한 연구)

  • 이택민;이동윤;양민양
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.1
    • /
    • pp.31-39
    • /
    • 2004
  • This paper presents design solutions for cam type transfer unit in which feeding, lifting, and clamping motions are generated by cams. In order to achieve faster transfer motion, each designed cam must satisfy the given specifications such as velocity, acceleration, jerk, pressure angle, cam thickness, and torque. To reduce absolute torque magnitude and torque variation, a conjugate cam and a torque reduction cam are used respectively. The conjugate cam eliminates the redundant pre-load by using complementary cam to avoid jumping between a cam and a follower. The torque reduction cam reduces the torque variation by applying opposite torque to a cam shaft. The experimental result shows the reductions of the absolute torque value and torque variation. The improvement of working speed and life span of cam type transfer unit can be expected.

Performance analysis of a horn-type rudder implementing the Coanda effect

  • Seo, Dae-Won;Oh, Jungkeun;Jang, Jinho
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.2
    • /
    • pp.177-184
    • /
    • 2017
  • The Coanda effect is the phenomenon of a fluid jet to stay attached to a curved surface; when a jet stream is applied tangentially to a convex surface, lift force is generated by increase in the circulation. The Coanda effect has great potential to be applied practically applied to marine hydrodynamics where various lifting surfaces are being widely used to control the behavior of ships and offshore structures. In the present study, Numerical simulations and corresponding experiments were performed to ascertain the applicability of the Coanda effect to a horn-type rudder. It was found that the Coanda jet increases the lift coefficient of the rudder by as much as 52% at a jet momentum coefficient of 0.1 and rudder angle of $10^{\circ}$.

Design and Implementation of Paddle Type End of Arm Tool for Rescue Robot (인명 구조용 로봇의 패들형 말단 장치 설계 및 구현)

  • Kim, Hyeonjung;Lee, Ikho;An, Jinung
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.4
    • /
    • pp.205-212
    • /
    • 2018
  • This paper deals with the paddle type end of arm tool for rescue robot instead of rescue worker in dangerous environments such as fire, earthquake, national disaster and defense. It is equipped at the dual arm manipulator of the rescue robot to safely lift up an injured person. It consists of the paddle for lifting person, sensors for detecting insertion of person onto the paddle, sensor for measuring the tilting angle of the paddle, and mechanical compliance part for preventing incidental injuries. The electronics is comprised of the DAQ module to acquire the sensors data, the control module to treat the sensors data and to manage the errors, and the communication module to transmit the sensors data. After optimally designing the mechanical and electronical parts, we successfully made the paddle type end of arm tool and evaluated its performance by using specially designed jigs. The developed paddle type end of arm tool is going to be applied to the rescue robot for performance verification through field testing.