• Title/Summary/Keyword: lid technique

Search Result 62, Processing Time 0.036 seconds

A Study on the Water Cycle Improvement Plan of Low Impact Development (저영향개발 기법의 물순환 개선 방안 연구)

  • Kim, Byungsung;Lim, Seokhwa;Lee, Sangjin;Baek, Jongseok;Kim, Jaemoon
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.2
    • /
    • pp.109-115
    • /
    • 2020
  • Recently, since impervious areas have increased due to urban development, the water cycle system of urban watersheds has been destructed. Hence, researches on LID (Low Impact Development) technique have been conducted to solve such problems environmentally. In order to verify suitability with the scale and arrangement of LID technique, the runoff reduction effect of the LID technique should be analyzed per small watershed unit. In this study, pre-post difference of the runoff by applying the LID was estimated using the rational method and rainwater treatment capacity equation. As a result, the runoff before and after the application of LID were estimated as 22,533.5 ㎥ and 14,992.1 ㎥, respectively. In addition, rainfall-runoff simulations were carried out using SWMM to evaluate the efficiency of the LID technique. The SWMM simulation results showed that the runoff before and after the application of LID were 21,174 ㎥ and 15,664 ㎥, respectively. Based on the results of the two methods, the scale and arrangement of the LID technique were revised in order to maximize the effect of the water cycle improvement. Rainfall-runoff simulations were carried out using the SWMM with the revised LID techniques. As a result, despite 34.8 % reduction of pervious pavement area, the rate of runoff reduction increased by 2.1 %. These results indicate that designing the scale and arrangement of LID technique, while considering the total amount of inflow entering into each LID techniques, is essential to effectively achieve the goals of runoff reduction in urban development.

Water Balance Estimate of LID Technique for Circulating Urban Design (순환형 도시계획에 따른 LID기술의 물수지 분석)

  • Kang, Sung-Hee;Heo, Woo-Myung;Kang, Sang-Hyeok
    • Journal of Environmental Science International
    • /
    • v.24 no.8
    • /
    • pp.1065-1073
    • /
    • 2015
  • Urbanization can be significantly affected the hydrologic cycle by increasing flood discharge and heat flux. In order to mitigate these modifications in urban areas, Low Impact Development (LID) technique has been designed and applied in Korea. In order to estimate runoff reduction rate using SWMM LID model, the characteristics of five LID techniques was firstly analyzed for water balance. Vegetated swale and green roof were not reduce flood discharge nor infiltration amount. On the other hand, porous pavement and infiltration trench were captured by infiltration function. The flood reduction rate with LID is substantially affected by their structures and properties, e.g., the percentage of the area installed with LID components and the percentage of the drainage area of the LID components.

Retrograde filling with Lid technique in periapical surgery: case report (Lid technique을 활용하여 치근단 수술에서 역충전을 시행한 증례 보고)

  • Yoon-Joo Lee;Kyung-Mo Cho;Se-Hee Park;Yoon Lee;Jin-Woo Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.1
    • /
    • pp.45-51
    • /
    • 2023
  • Apical sealing with proper retrograde filling material and technique is the key factor for successful apical surgery. In order to provide impeccable apical sealing and healing, various mechanical and chemical characteristics of retrograde filling material is required. MTA has been used as the gold standard of retrograde filling due to its unprecedented advantages. As MTA has long setting time and difficult handling properties, premixed putty type bioceramic material has been newly developed. For efficient retrofilling with premixed putty type biocreamic material, 'Lid technique' was also proposed. The following cases present apical surgery using newly developed premixed putty type bioceramic material with Lid technique.

LIDMOD Development for Evaluating Low Impact Development and Its Applicability to Total Maximum Daily Loads (지속가능한 도시개발을 위한 LID평가모델(LIDMOD)개발과 수질오염총량제에 대한 적용성 평가)

  • Jeon, Ji-Hong;Choi, Dong Hyuk;Kim, Tae Dong
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.58-68
    • /
    • 2009
  • Low impact development (LID) technique is relatively new concept to reduce surface runoff and pollutant loading from land cover by attempting to match predevelopment condition with various integrated management practices (IMPs). In this study, computational model for designing and evaluating LID, named LIDMOD, was developed based on SCS-CN method and applied at Andong bus terminal to evaluate LID applicapability and design retention/detention area for volume or peak flow control. LIDMOD simulated with 21 years simulation period that yearly surface runoff by post-development without LID was significantly higher than that with LID showing about 2.8 times and LID could reduce efficiently yearly surface runoff with 75% reduction of increased runoff by conventional post development. LIDMOD designed detention area for volume/peak flow control with 20.2% of total area by hybrid design. LID can also efficiently reduce pollutant load from land cover. Pollutant loads from post-development without LID was much higher than those from pre-development with showing 37 times for BOD, 2 times for TN, and 9 times for TP. Pollutant loads from post-development with LID represented about 57% of those without LID. Increasing groundwater recharge reducing cooling and heating fee, creating green refuge at building area can be considered as additional benefits of LID. At the point of reducing runoff and pollutant load, LID might be important technique for Korean TMDL and LIDMOD can be useful tool to calculate unit load for the case of LID application.

A Study on the Runoff Reduction According to the Calculation Method of the LID Scale Considering the Land Use Area and the Application of Stormwater Storage Basin (토지이용면적을 고려한 LID 규모 산정 및 우수저류지 적용에 따른 유출저감 연구)

  • Kim, Byung Sung;Kim, Jea Moon;Kim, Seong Su;Shin, Gang Wook;Lee, Sang Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.3
    • /
    • pp.229-235
    • /
    • 2021
  • Globally, due to climate change and urbanization, problems with water cycle destruction in urban areas frequently occur. In order to solve this problem, LID technique is being actively conducted the application in urban and research. In this study, some areas of the new city located in Busan was constructed using a widely used SWMM model to verify the effectiveness of the LID technique. This is to present a plan to maximize the efficiency of urban water cycle of the stormwater management target figure and the LID scale calculation method. In addition, the efficiency of runoff reduction using stormwater storage basin was analyzed in urban development projects. By calculating the scale of customized LID for each sub basin, the amount of runoff and peak runoff after LID application was reduced by 86.8 % and 69.5 %, respectively. Depending on the application of the stormwater storage basin, the reduction effect of peak runoff from 0.5 m3/s to 4.9 m3/s and delay effect of 8 minutes to 10 minutes was shown.

The Sectional Analysis of Trunk-lid using the Equilibrium Approach and Three-Dimensional Shape Composition (평형해법을 이용한 트렁크 리드의 단면해석과 3차원 형상합성)

  • 정동원
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.66-71
    • /
    • 2001
  • A sectional analysis of trunk-lid carried out by using the equilibrium approach based on the force balance together with geometric relations and plasticity theory. In computing a force balance equation, it is required to define a geometric curve approximating the shape of sheet metal at any step of deformation from the interaction between the die and the deformed sheet. The trunk-lid panel material is assumed to possess normal anisotropy and to obey Hill's new yield criterion. Deformation of each section of trunk-lid panel is simulated and composed to get the three-dimensional shape by using CAD technique. It was shown that the three-dimensional shape composition of the two-dimensional analysis.

  • PDF

Development of BIM based LID Facilities Supply Auto-checking Module (BIM 기반 LID 시설 물량 자동 검토 모듈 개발)

  • Choi, Junwoo;Jung, Jongsuk;Lim, Seokhwa;Choi, Joungjoo;Kim, Shin;Hyun, Kyounghak
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.3
    • /
    • pp.195-206
    • /
    • 2017
  • Recently, Discussion about BIM based LID (Low Impact Development) facilities management system is activated because interest of LID technique for urban water cycle restoration is increasing. For this reason, this paper developed the auto-checking module of the BIM (Building Information Model) based supply output table. This module will be the foundation of the BIM based LID facilities total management system. The research order is composed like next follows: (1) Select target area, (2) Make BIM model of LID facilities and extract supply output table, (3) Develop comparison module, (4) Analysis results. As a result, the authors made 27 LID facilities and developed the supply output table comparison automation module. So, the authors could find differences of 2D design documents based supply output table and BIm based supply output table. So, the authors made an improvement suggestion of the design plan and could construct foundation of the BIM based LID facilities total management system.

An Analysis of the water balance of Low Impact Development Techniques According to the Rainfall Types (강우 유형에 따른 저영향개발 기법별 물수지 분석)

  • Yoo, Sohyun;Lee, Dongkun;Kim, Hyomin;Cho, Youngchul
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.2
    • /
    • pp.163-174
    • /
    • 2015
  • Urbanization caused various environmental problems like destruction of natural water cycle and increased urban flood. To solve these problems, LID(Low Impact Development) deserves attention. The main objective of LID is to restore the water circulation to the state before the development. In the previous studies about the LID, the runoff reduction effect is mainly discussed and the effects of each techniques of LID depending on rainfall types have not fully investigated. The objective of this research is to evaluate the effect of LID using the quantitative simulation of rainwater runoff as well as an amount of infiltration according to the rainfall and LID techniques. To evaluate the water circulation of LID on the development area, new land development areas of Hanam in South Korea is decided as the study site. In this research, hydrological model named STORM is used for the simulation of water balance associated with LID. Rainfall types are separated into two categories based on the rainfall intensity. And simulated LID techniques are green roof, permeable pavement and swale. Results of this research indicate that LID is effective on improvement of water balance in case of the low intensity rainfall event rather than the extreme event. The most effective LID technique is permeable pavement in case of the low intensity rainfall event and swale is effective in case of the high intensity rainfall event. The results of this study could be used as a reference when the spatial plan is made considering the water circulation.

Application of SWMM for Reduction of Runoff and Pollutant Loading in LID Facilities (LID시설의 유출량 및 오염부하 저감효율평가를 위한 SWMM모델의 적용)

  • Jung, Kwang-Wook;Jung, Jong-Suk;Park, Jin-Sung;Hyun, Kyoung-Hak
    • Land and Housing Review
    • /
    • v.8 no.4
    • /
    • pp.249-256
    • /
    • 2017
  • Urbanization can be remarkable affected flood, pollutant loading, ecological system, and green infrastructure by distortion of hydrologic cycle. In order to mitigate these problems in urban, Low Impact Development(LID) technique has been introduced and applied in the world. SWMM model was calibrated with sets of field monitoring data and applied for calculation of runoff and pollutant loading in Asan-tangjung LID city under 2016 rainfall. Runoff reduction of watershed and catchment basins were showed efficiency 12.2% and 62.0%, respectively. Reduction of COD and TP loading also high efficiency in catchment basins were evaluated 74.9 and 71.4%. The results of this study can be used effectively in decision making processes of urban development project by comparing watershed runoff and pollutant reduction by designs of sort of LID technique, LID volume and location.

Analysis of Effect on Runoff and Water Quality of LID using Infiltration Facilities (우수 침투 시설을 활용한 친환경 도시 개발지구에서의 유출량 및 비점오염 저감 효과 분석)

  • Hwang, Jin-Yong;Yeon, Kyu-Seok;Kim, Ik-Jae;Kim, Ki-Sung;Choi, Joong-Dae;Jeon, Ji-Hong;Lim, Kyoung-Jae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.6
    • /
    • pp.105-114
    • /
    • 2009
  • With urbanization in many countries, many pervious areas are being converted into impervious areas. These land use changes cause many negative impacts on runoff and water quality in the areas. Especially runoff volume and peak runoff are increasing with urbanization. In addition to the increased runoff, more pollutant transports to the downstream areas. For these reasons, Low Impact Development (LID) are nowadays being introduced in urban planning. For environment-friendly and economical urban development, the LID Integrated Management Practices (IMPs) are applied in various urban development. However, exact effects on runoff and water quality of various LID IMPs are not assessed with proper LID evaluation technique. Thus, the SWMM (Storm Water Management Model) 5.0 model was slightly modified to simulate the effect of infiltration manhole on runoff and water quality. For comparison of runoff and TSS (Total Suspended Solids) from the study area (26.5 ha), three scenarios were made in this study. It was found that runoff volume, peak runoff, and TSS could be reduced with infiltration manholes and pervious pavements to some degree. Although, there are many limitations in the analysis of LID effects on runoff and TSS, similar trends shown in this study would be expected with site-specific LID IMPs. Thus, it is strongly recommended that various site-specific LID IMPs, such as infiltration facilities, should be applied as much as possible for environment-friendly urban planning.