• Title/Summary/Keyword: level of detector

검색결과 506건 처리시간 0.025초

지하철 역내 가스 검출 원격 모니터링 시스템 구현 (Development of a remote monitoring system for gas detection at the subway station)

  • 박용만;김희식;김규식;이문규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

염화비닐 노출 근로자의 요중 Malondialdehyde 농도 수준 (The level of urinary malondialdehyde concentrations in vinyl chloride monomer exposure workers)

  • 김현수;김치년;원종욱;박준호;김광숙;안미현;노재훈
    • 한국산업보건학회지
    • /
    • 제17권2호
    • /
    • pp.81-88
    • /
    • 2007
  • The aim of this study was to investigate whether the exposure to vinyl chloride monomer(VCM) induces lipid peroxidation in workers by evaluating the concentration of malondialdehyde(MDA) in the urine in order to assess worker's oxidative stress due to exposure of vinyl chloride monomer. The subjects investigated in the study were divided into the experimental group; 18 workers exposed to VCM, and the control group; 19 workers unexposed to VCM. A gas chromatography/pulsed flame photometric detector(GC/PFPD) was utilized to analyze thiodiglycolic acid(TDGA), which was methylated with trimethylsilyldiazomethane (2.0M in diethyl ether) in urine and the urinary MDA, the product of lipid peroxidation, was determined by high-performance liquid chromatography/ultraviolet-visible detector after derivatized with 2,4-dinitrophenylhydrazine(DNPH). The concentrations of urinary TDGA in controls and VCM exposure workers were 0.13(2.01)mg/g Cr. GM(GSD) and 0.35(1.96)mg/gCr. GM(GSD), respectively. The concentrations of urinary MDA were $0.12(2.21){\mu}mol/gCr$. GM(GSD) in controls and $1.35(1.79){\mu}mol/gCr$. GM(GSD) in VCM exposure workers. As a result of simple regressions analysis between urinary concentration of TDGA and MDA in VCM exposure workers, it was found that the $R^2$ value was 0.261 (p=0.03) and the drinking and smoking did not affect their level. In conclusion, the workers exposed to VCM have a potentially to suffered by oxidative stress due to VCM exposure and the urinary MDA can be applicable to the marker of effect to assess the level of worker's VCM exposure.

Evaluation of Azygos Vein to Aorta Ratio using Multi-Detector Computed Tomography in Dogs

  • Park, Hyunyoung;Kim, Jungyong;Kim, Soochan;Jeong, Woochang;Lee, Jungwoo;Choi, Sooyoung;Choi, Hojung;Lee, Youngwon
    • 한국임상수의학회지
    • /
    • 제37권2호
    • /
    • pp.82-87
    • /
    • 2020
  • The purpose of this study is to evaluate the azygos vein to aorta diameter ratio (AV/AO ratio) in healthy dogs and dogs with diseases that may cause azygos vein dilation. The normal groups included eleven healthy beagle dogs and eleven small breed dogs. The abnormal group included 43 dogs that had diseases with high right atrial pressure (RA group), obstruction of cranial or caudal vena cava (CVC group) and porto-azygos shunt group (PSS group). The diameter of AV and AO were measured at three sites on thoracic CT images; the level of the cranial endplate of 12th thoracic vertebra (TV level), the tracheal bifurcation (TB level) and the insertion to the cranial vena cava (CrVC level). The AV/AO ratio at the CrVC level had significantly higher values than those at the TV and TB levels in the normal groups. The AV/AO ratios of TV and TB levels in the CVC group and the values at all measurement sites of the PSS group were significantly higher than the normal groups. AV/AO ratio will be a useful factor for the evaluation of various clinical conditions that change the AV diameter with respect independent to the body weight in dogs.

유효검출양자효율과 선량을 이용한 소아 흉부 X-선 영상의 기술적인 인자에 관한 조사 (Survey of Technical Parameters for Pediatric Chest X-ray Imaging by Using Effective DQE and Dose)

  • 박혜숙;김예슬;김상태;박옥섭;전창우;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.163-171
    • /
    • 2011
  • 본 연구에서는 피사체에 의한 산란, 초점에 의한 흐림, 기하학적 확대도 그리고 검출기의 특성이 반영된 유효검출양자효율(effective detective quantum efficiency, eDQE)과 유효선량을 평가하여 소아 흉부 X선 촬영 시 선량의 최적화를 위한 조사조건의 영향을 평가하였다. 100, 110, 120, 150, 180 cm의 FDD (focus-to-detector distance)일 때 관전압을 40 kVp에서 90 kVp까지 10 kVp씩 증가시켜가며 동일한 유효선량일 때 eDQE를 평가하였다. 그 결과 eDQE는 다른 관전압과 비교 시60 kVp에서 가장 높은 값을 보였다. 특히, 동일한 유효선량일 때 그리드가 없을 경우 상대적으로 매우 높은 eDQE를 나타냈다. 이는 그리드에 의한 산란선의 감소가 그리드에서 흡수된 유효 광자의 손실을 보상하지 못하기 때문이다. 그리드 가 없을 경우 FDD가 증가할수록 향상된 유효변조전달함수(effective modulation transfer function, eMTF)로 인하여 eDQE는 증가하였다. 국내 대형병원들의 대부분은 15개월 소아의 흉부 X선 촬영 시 그리드와 함께 100 cm의 짧은 FDD를 사용하고 있다. 그 결과 대부분의 경우는 국내 환자선량권고량(diagnostic reference level, DRL) $100{\mu}Gy$을 초과하였다. 이는 5세 소아 흉부 X선 촬영 시 150 cm에서 180 cm 사이의 긴 FDD를 사용하지만, 15개월을 모사하고 있는 표준 소아팬텀의 흉부 X선 촬영의 경우 100 cm의 짧은 FDD를 사용했기 때문이다. 따라서, 나이에 따른 소아의 흉부 X선 촬영을 시행하기 위한 적절한 조사조건이 확립되어야 한다. 본 연구 결과는 나이에 따른 소아 선량의 권고량을 설립하는데 기초자료로 활용될 수 있을 것이다.

환경 대기 중 ppt 수준의 황화수소 분석을 위한 GC 방식의 검량 기법에 대한 연구 (Calibration Methods for the Gas Chromatographic Analysis of ppt-level Hydrogen Sulfide (H2) in Air)

  • 김기현;오상인;최여진;최규훈;주도원
    • 한국대기환경학회지
    • /
    • 제19권6호
    • /
    • pp.679-687
    • /
    • 2003
  • In this study, we investigated the analytical techniques to quantify the ambient concentration of hydrogen sulfide (H$_2$S) in air at ppt concentration level. For this purpose, an on-line GC analytical system equipped with both pulsed-flame photometric detector (PFPD) and thermal desorption unit (TDU) was investigated by collecting ambient air samples. The results of our study generally indicated that calibration conditions of GC system is highly sensitive to affect the accuracy of the analytical technique. Most importantly. we found that the use of different matrices in the the preparation stage of working standards was sensitive to control the overall performance of this technique. The calibration of our analytical system was tested by the two types of working standard (prepared by mixing either with high purity $N_2$ or with the ambient air). According to this test, the latter represented more efficiently the detecting conditions of actual air samples. The peak occurrence patterns of both air samples and standards (prepared by mixing with ambient air) were altered in a similar manner as the function of the loaded volume; however, it was not the case for the $N_2$-mixed standards. Results of our study suggest that detection of H$_2$S is highly different from other sulfides and that its quantification requires minimiaing interfering effects of non -pure substance (like water vapor) and (either sorptive or destructive) loss effects.

3D CACT-assisted Radiofrequency Ablation Following Transarterial Chemoembolization for Hepatocellular Carcinoma: Early Experience

  • Jiao, De-Chao;Han, Xin-Wei;Wu, Gang;Ren, Jian-Zhuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권17호
    • /
    • pp.7897-7903
    • /
    • 2015
  • Background: To explored the value of 3D C-arm CT (CACT) guidance system in performing radiofrequency ablation (RFA) following transarterial chemoembolizationon (TACE) for hepatocellular carcinomas. Materials and Methods: RFA of hepatocellular carcinomas (HCC) were performed on 15 patients (21 lesions) with the assistance of CACT guidance system. Technical success, procedure time, complications and patient radiation exposure were investigated. The puncture performance level was evaluated on a five-point scale (5-1: excellent-poor). Complete ablation rate was evaluated after two months follow-up using enhanced CT scans. Results: The technical success rate of RFA procedure under CACT navigation system was 100 %. Mean total procedure time was $24.24{\pm}6.53min$, resulting in a mean effective exposure dose of $15.4{\pm}5.1mSv$. The mean puncture performance level rated for CACT guided RFA procedure was $4.87{\pm}0.35$. Complete ablation (CA) was achieved in 20 (95.2%) of the treated 21 tumors after the first RFA session. None of patients developed intra-procedural complications. Conclusions: 3D CACT guidance system enables reliable and efficient needle positioning by providing real-time intraoperative guidance for performing RFA on HCCs.

Charge Redistribution of Pt-based Alloys

  • Lim, K.Y.;Chung, Y.D.;Kwon, S.Y.;Lee, Y.S.;C.N.Whang;Y.Jeon;Park, B.S.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.171-171
    • /
    • 1999
  • We studied the charge redistribution in the Pt-M (M=Cu, Co) alloys by X-ray Absorption Near Edge Spectroscopy(XANES) and X-ray Photoelectron Spectroscopy(XPS). These analysis tools provide us information about the charge transfer in the valence band of intermetallic bonding. The samples were prepared by arc-melting method. After annealing this samples in vacuum for several hours, we cold get the ordered samples, which were confirmed with XRD analysis. the core and valence level energy shift in these system were investigated by Mg $K\alpha$(1253.6eV) x-ray source for Pt-Co alloys and monochromatized Al $K\alpha$ (1486.6eV) for Pt-Cu alloys. Pt L2, L3-edge, and Cu, Co K-edge XANES spectra were measured with the total electron-yield mode detector at the 3Cl beam line of the PLS (Pohang light source0. from the changes of White line (WL) area and the core level shifts of the each metal sites, we can obtain the information about the electrons participating in the intermetallic bonding of the Pt-Cu and Pt-Co alloys.

  • PDF

Gas Chromatography Residue Analysis of Bifenthrin in Pears Treated with 2% Wettable Powder

  • Choi, Jeong-Heui;Liu, Xue;Kim, Hee-Kwon;Shim, Jae-Han
    • Toxicological Research
    • /
    • 제25권1호
    • /
    • pp.41-45
    • /
    • 2009
  • This study was conducted to monitor the level of bifenthrin residues in pear sprayed with 2% bifenthrin wettable powder (WP) at the recommended rate at four different schedules prior to harvest. The target analyte was extracted with acetone, partitioned into dichloromethane, and then purified by florisil chromatographic column. The residue determination was performed on a DB-5 capillary column using GC with electron capture detector (ECD). Linearity of this method was quite good ($r^2$ = 0.9951) in the concentration ranged from 0.2 mg/kg to 10 mg/kg. Recovery test was carried out at two concentration levels, 0.2 mg/kg and 1.0 mg/kg, in three replicates, and their rates were from 82.9% to 107.2%. No quantitative bifenthrin was detected in pear of all kinds of treatments including the treatment sprayed 4 times until 7 days before harvest. This sensitive and selective method can be used to monitor the trace residual amounts of bifenthrin in pear in a quite low concentration level.

지능 영상 감시를 위한 흑백 영상 데이터에서의 효과적인 이동 투영 음영 제거 (An Effective Moving Cast Shadow Removal in Gray Level Video for Intelligent Visual Surveillance)

  • 응웬탄빈;정선태;조성원
    • 한국멀티미디어학회논문지
    • /
    • 제17권4호
    • /
    • pp.420-432
    • /
    • 2014
  • In detection of moving objects from video sequences, an essential process for intelligent visual surveillance, the cast shadows accompanying moving objects are different from background so that they may be easily extracted as foreground object blobs, which causes errors in localization, segmentation, tracking and classification of objects. Most of the previous research results about moving cast shadow detection and removal usually utilize color information about objects and scenes. In this paper, we proposes a novel cast shadow removal method of moving objects in gray level video data for visual surveillance application. The proposed method utilizes observations about edge patterns in the shadow region in the current frame and the corresponding region in the background scene, and applies Laplacian edge detector to the blob regions in the current frame and the corresponding regions in the background scene. Then, the product of the outcomes of application determines moving object blob pixels from the blob pixels in the foreground mask. The minimal rectangle regions containing all blob pixles classified as moving object pixels are extracted. The proposed method is simple but turns out practically very effective for Adative Gaussian Mixture Model-based object detection of intelligent visual surveillance applications, which is verified through experiments.

An integrated DNA barcode assay microdevice for rapid, highly sensitive and multiplex pathogen detection at the single-cell level

  • Jung, Jae Hwan;Cho, Min Kyung;Chung, So Yi;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.276-276
    • /
    • 2013
  • Here we report an integrated microdevice consisting of an efficient passive mixer, a magnetic separation chamber, and a capillary electrophoretic microchannel in which DNA barcode assay, target pathogen separation, and barcode DNA capillary electrophoretic analysis were performed sequentially within 30 min for multiplex pathogen detection at the single-cell level. The intestine-shaped serpentine 3D micromixer provides a high mixing rate to generate magnetic particle-pathogenic bacteria-DNA barcode labelled AuNP complexes quantitatively. After magnetic separation and purification of those complexes, the barcode DNA strands were released and analyzed by the microfluidic capillary electrophoresis within 5 min. The size of the barcode DNA strand was controlled depending on the target bacteria (Staphylococcus aureus, Escherichia coli O157:H7, and Salmonella typhimurium), and the different elution time of the barcode DNA peak in the electropherogram allows us to recognize the target pathogen with ease in the monoplex as well as in the multiplex analysis. In addition, the quantity of the DNA barcode strand (~104) per AuNP is enough to be observed in the laser-induced confocal fluorescence detector, thereby making single-cell analysis possible. This novel integrated microdevice enables us to perform rapid, sensitive, and multiplex pathogen detection with sample-in-answer-out capability to be applied for biosafety testing, environmental screening, and clinical trials.

  • PDF