• 제목/요약/키워드: level of control criteria

검색결과 364건 처리시간 0.024초

각성도 제어를 위한 평가기준의 설정 및 경고음의 효과분석 (Evaluation of the Criteria for the Control of Arousal Level and Effect of Warning Signal)

  • 김연호
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.79-86
    • /
    • 1997
  • This paper describes the development of portable arousal measurement and analysis system. Skin impedance change which responds to the change of arousal level was detected by the three elctrode constant current method and separated into two components(SIR, SIL). Relationship between Nz, IRI and arousal level was studied and criteria of arousal level control was decided by the sleep study. Measured data with and without warning signal were compared and analyzed.

  • PDF

Quality Control of Pharmacopuncture: A Comparative Study of Good Manufacturing Practice and External Herbal Dispensary Standards

  • Han, Ji-Eun;Park, Minjung;An, Tteul-E-Bom;Park, Jong-Hyun;Oh, Danny;Kim, Kyeong Han;Sung, Soo-Hyun
    • 대한약침학회지
    • /
    • 제24권2호
    • /
    • pp.59-67
    • /
    • 2021
  • Objectives: We aimed to compare the external herbal dispensary (EHD) evaluation criteria for pharmacopuncture and the Korea Good Manufacturing Practice (KGMP) sterile medicine standards to contribute to the establishment of quality control criteria for pharmacopuncture. Methods: We obtained the KGMP standards from the Ministry of Food and Drug Safety and the pharmacopuncture certification criteria from the Ministry of Health and Welfare of South Korea. The EHD evaluation items were classified into three categories: facilities, quality control, and validation. The evaluation items were compared with the KGMP sterile medicine criteria to determine their conformance with each other, followed by a discussion among the committee of six experts and their consensus to suggest the items to complement the EHD evaluation criteria. Results: Among the KGMP sterile medicine criteria, 44 were related to the management of the facilities, and 32 pharmacopuncture evaluation items corresponded to these KGMP items (66.7%). Fifty-eight KGMP criteria were related to quality management, and 42 pharmacopuncture evaluation items corresponded to these KGMP items (72.4%). Twentyfive KGMP sterile medicine criteria were related to validation, and 11 pharmacopuncture evaluation items corresponded to these KGMP items (44.0%). Sixteen items under the pharmacopuncture EHD criteria corresponded to the KGMP sterile medicine criteria based on the consent of the experts. Among these, 4 were related to facility management, 6 were related to quality control, and 6 were related to validation. Conclusion: For the safety and quality control of pharmacopuncture, there is a need to select the criteria for the mandatory items among the proposed pharmacopuncture-EHD criteria laws and systems to ensure that the pharmacopuncture materials are produced under the pharmacopuncture-EHD in compliance with the relevant requirements. More studies are needed to secure the safety level of pharmacopuncture materials corresponding to that of conventional medicine.

SIC에 의한 각성도 제어를 위한 평가기준의 설정 및 비교 (Comparison and The Evaluation of Criteria for Arousal Level Control)

  • 고한우;김연호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.372-376
    • /
    • 1996
  • This paper describes the criterias to evaluate arousal states of subject and these are applied to contort arousal level. Correction factor was introdued to compensate under or over evaluated Nz due to the different initial basal skin impedance. These criteria and correction factor were worked well to increase the arousal level.

  • PDF

넙치 양식장의 질병관리등급 평가기준 개선 및 적용 (Improvement and Application of Assessment Criteria on Disease Control Level in Olive Flounder Aquaculture Farms)

  • 조미영;하헌주;민진기;김태진;지보영;박신후;황성돈;김광일;장영환;박명애
    • 수산해양교육연구
    • /
    • 제27권6호
    • /
    • pp.1646-1655
    • /
    • 2015
  • Korean government has issued the ratings standard for disease control of aquaculture farms according to the Aquatic Life Disease Control Act in 2008. There are five rating criteria within the enforcement regulations; period of disease free, performance of disinfection, environmental and hygienic management, keeping record of trade and sales, completion of education for disease control. There are no application has been applied on the basis of the rating criteria so far because detailed subcriteria and scoring indicators has not established for assessment process. In order to apply the ratings standard for disease control, we set up the subcriteria and new scoring for rating disease control level based on legal criteria in this study. This study was conducted on 90 targeted olive flounder farms in Jeju. The result of disease control level assessment on olive flounder aquaculture farms show the overall average of Jeju-do was 72.9 points and differed depending on the district; 74.7 in Jeju-si and 71.1 in Seogwipo-si, respectively. The Spearman correlation of each evaluation index show the disease control level score was correlated highly with the performance of disinfection(R=0.715, p<0.01), and environmental and hygienic management(R=0.661, p<0.01). The result of correlation analysis show that there is the highest correlation between the aquaculture farm status and the total mortality(R= -0.618, p<0.01). The reliability of the results are considered to be accurate in the Cronbach's alpha value of 0.727.

칼라 TV의 화면조정에 관한 사용자 특성 (User's characteristics on the screen adjustment of color TV)

  • 정광태;박재희;유금선
    • 대한인간공학회지
    • /
    • 제18권2호
    • /
    • pp.81-89
    • /
    • 1999
  • User's characteristics on the screen adjustment of color TV were studied. Two experiments were performed. In the first experiment, the characteristic of screen adjustment according to TV program, ambient luminance, and gender was investigated. Twenty subjects (10 females and 10 males) were participated in this experiment. Set points of brightness, contrast, tint, and color were measured on TV screen and analyzed. Brightness and contrast were significant on gender at significant level 0.01 and color was significant on gender at significant level 0.1. Tint was significant on program at significant level 0.01. The second experiment was performed to supplement the first experiment. The influences of ambient luminance, presented image, screen setting criteria, and gender were investigated. We simplified the first experiment in the second one. We restricted dependent variables (screen control variables) to only two, brightness and contrast. Other control variables were fixed to middle values. Brightness and contrast were significant on gender and screen setting criteria at significant level 0.01. In conclusion, we found that ambient luminance and presented image had no significant effects on TV screen adjustment and TV program had only a significant effect on tint. However, we found that gender and screen setting criteria had significant effects in most conditions.

  • PDF

실습선 가야호의 항해 중 선내 소음에 대한 승선환경 (Boarding Environment of Training Ship KAYA to the Noise during the Voyage)

  • 김민선;신현옥;김민석;황보규
    • 수산해양교육연구
    • /
    • 제22권2호
    • /
    • pp.218-230
    • /
    • 2010
  • This study was conducted to determine the effect of the noise level on the boarding environment in a stern trawl ship, KAYA(GT: 1,737 tons, Pukyong National University). We measured the noise level at a working, an accommodation and a teaching area, and an engine space on January 9, 2010 while the KAYA was sailing on a liner sea route. At the working area, the ranges of the noise rating number(NRN) and the NRN determination frequency(FNRN) were from 44 to 73 and from 1000 to 2000Hz, respectively. The results were generally satisfied the criteria of the International Maritime Organization(IMO). The noise level at the area, except the radio room(w2), was exceeded the criteria(50dB(A)) for the efficient studying and working. The noise level at the engine control room and the machine workshop was respectively exceeded 1.2dB and 9.5dB than the criteria caused the conversation disturbance (70dB(A)). At the accommodation, NRN and FNRN were from 49 to 54 and from 1000 to 4000Hz, respectively. The noise level was below the criteria of IMO, but above 40dB(A) caused the sleep disturbance. At the teaching area, NRN and FNRN were from 44 to 63 and from 500 to 2000Hz, respectively. The noise level was exceeded than the criteria(50dB(A)) for the efficient studying. At the engine space, NRN and FNRN were from 95 to 100 and from 2000 to 4000Hz, respectively. The noise level was above the criteria of IMO(90dB(A)) for the residence, while it was not exceeded 110dB(A) for the transient.

국방 지휘·통제 시설을 위한 ICAN, I3A 설계기준 (ICAN, I3A Design Criteria for Military Defense Command & Control Facilities)

  • 조윤정
    • 한국통신학회논문지
    • /
    • 제42권4호
    • /
    • pp.806-815
    • /
    • 2017
  • 한국군은 국방시설기준이 정립되어 있으나 대부분 시설위주의 설계기준에 중점을 두고 작성되어 있다. 특히 정보통신분야에서는 세부적인 기준은 제시하지 않고 대략적인 수준으로만 제시되어 있다. 미군의 경우 1990년부터 각 군이 공통적으로 적용 가능한 시설기준에 대하여 통합시설기준서(UFC : Unified Facilities Criteria)를 완성해 모든 사업에 공통적용 할 수 있도록 설계기준을 제시하고 있다. 특히 정보통신분야에서는 시설분야와 연계해서 건물내부체계는 미군의 기지통신 기반구조설계기준(I3A: Installation, Information, Infrastructure Architecture)과 시스템에 대해서는 기지 및 캠퍼스지역 네트워크설계기준(ICAN : Installation and Campus area Network)과 비교를 통해 우리군의 지휘 통제시설 및 일반/행정시설에 대한 바람직한 설계기준선을 제시한다.

홍수재난 대응을 위한 국가위기경보 4단계 설정기준 개선 (Improvement of National Risk Alarm 4-Stage Criteria for Flood Disaster)

  • 이수경;박재우;오은호
    • 한국콘텐츠학회논문지
    • /
    • 제18권3호
    • /
    • pp.369-377
    • /
    • 2018
  • 홍수 발생 시 제공되는 적절한 비상대처방안(EAP) 정보는 재난에 효과적으로 대응하기 위한 필수요소이며, 상습 침수지역과 예상지역의 인명 및 재산피해를 줄이는 중요한 역할을 한다. 국내에서 사용하는 대부분의 EAP는 국가위기관리기본지침의 위기경보 4단계를 근간으로 해당 시설물에 대한 단계별 대응업무를 규정하도록 되어 있다. 이와 관련하여 홍수통제소는 수위표 또는 해발고도를 기준으로 하천지점별 홍수주의보와 홍수경보를 계획홍수량의 50%와 70%를 기준으로 발현하고 있으나, 위기경보 각 단계별 설정기준과의 명확한 연관관계를 제시하고 있지 않다. 반면, 일본과 미국의 경우 수재해 대응단계를 구분하는데 있어 하천수위를 가장 중요한 판단기준으로 삼고 있으며, 국내보다는 높은 계획홍수위 설정기준을 갖고 있다. 이에 본 연구는 국내 하천홍수 대응 수재해 위기경보 4단계 설정기준을 개선하기 위하여 국내외 관련 규정 및 적용현황을 분석하였으며, 실무자 관점에서 실효성을 제고하기 위하여 위기경보단계별 설정기준을 상향조정하고 수위표 기준으로 표기방식을 개선하도록 제안하였다. 적용성 및 실효성 검증을 위하여 개선된 설정기준(안)을 수변구조물 재난대응 의사결정시스템에 적용하고 테스트베드에 대한 모의훈련을 실시하였다.

운영 수준에서의 산업보안 관리대책 중요도 결정 (Decision Making for the Industrial Security Management Measures' Importance in Operation Level)

  • 채정우;정진홍
    • 한국콘텐츠학회논문지
    • /
    • 제13권4호
    • /
    • pp.389-398
    • /
    • 2013
  • 본 연구는 산업보안활동을 수행함에 있어, 운영 수준의 관리대책에 대한 전략적 우선순위 결정을 통해 합리적인 보안투자 의사결정 지원을 목적으로 하였다. 이를 위해 산업보안전문가들을 대상으로 AHP 설문조사를 시행, 분석하여 산업보안 관리대책들의 중요도와 우선순위를 결정하였다. 상위기준 비교평가에서는 'ICT서비스 사용관리'가 가장 높은 가중치(0.54)를 보였다. 하위기준은 중요도 순으로 3개 그룹으로 구분할 수 있었다. 민감도 분석결과, 'ICT시스템/통신망 접근통제'의 가중치를 2배 높이면 그 하위기준인 '운영체제 접근통제', '애플리케이션 접근통제', '유무선 네트워크 접근통제'의 전체 순위가 상위권으로 진입하였다. '물리/환경적 보안'의 가중치를 2배 높이면 그 하위기준인 '보호구역 설정 및 출입/접근통제'와 '업무설비방재/대테러 보호 배치'는 전체 순위가 상위권으로, '전원 등 유틸리티 상시 확보'는 중위권으로 상승함을 확인할 수 있었다.

사례 연구 : EN ISO 13849-1의 안전회로 설계를 위한 구체적 평가 기준의 적용 (Case Study : Application of Specific Evaluation Criteria For Safety Circuit Design of EN ISO 13849-1)

  • 정환석;이동주
    • 산업경영시스템학회지
    • /
    • 제41권1호
    • /
    • pp.94-101
    • /
    • 2018
  • With the development of industrial technology and science, production and manufacturing facilities have been enhanced and improved, and the importance of the safety of workers has also been regulated and limited by various safety management methods. As a way to secure the safety of the workers from the production facility, the fail-safe and fool-proof methods are now being applied. Any possible insecure behavior and unsafe conditions can be removed by adopting the standards and specifications that are now secure the safety of workers and equipment. This research analyzes EN ISO 13849-1 international and European standards during CE certification. In order to secure acceptable reduced risks, the risk assessment process of ISO 12100 and the processes for reducing its risk are applied. In the current ISO 13849-1 standard, the criteria for the required performance level PLr (Required Performance Level) for the applicable risk and safety functions through the risk assessment are subjective and not subdivided. Therefore, the evaluation criteria are likely to cause judge's judgement error due to qualitative judgement. This research focuses on evaluation and acceptable performance level setting for the safety circuit of the equipment. We propose an objective and specific evaluation criteria to secure safety, and the proposed evaluation criteria are applied to the case study of the safety circuit for the equipment. In order to secure the safety of the entire safety circuit, the improvement of the MTTFd and DC level related to the SRP/CS (Safety-Related Parts of Control Systems)' lifetime is required for the future research.