• Title/Summary/Keyword: level of control criteria

Search Result 364, Processing Time 0.024 seconds

Evaluation of the Criteria for the Control of Arousal Level and Effect of Warning Signal (각성도 제어를 위한 평가기준의 설정 및 경고음의 효과분석)

  • 김연호
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.79-86
    • /
    • 1997
  • This paper describes the development of portable arousal measurement and analysis system. Skin impedance change which responds to the change of arousal level was detected by the three elctrode constant current method and separated into two components(SIR, SIL). Relationship between Nz, IRI and arousal level was studied and criteria of arousal level control was decided by the sleep study. Measured data with and without warning signal were compared and analyzed.

  • PDF

Quality Control of Pharmacopuncture: A Comparative Study of Good Manufacturing Practice and External Herbal Dispensary Standards

  • Han, Ji-Eun;Park, Minjung;An, Tteul-E-Bom;Park, Jong-Hyun;Oh, Danny;Kim, Kyeong Han;Sung, Soo-Hyun
    • Journal of Pharmacopuncture
    • /
    • v.24 no.2
    • /
    • pp.59-67
    • /
    • 2021
  • Objectives: We aimed to compare the external herbal dispensary (EHD) evaluation criteria for pharmacopuncture and the Korea Good Manufacturing Practice (KGMP) sterile medicine standards to contribute to the establishment of quality control criteria for pharmacopuncture. Methods: We obtained the KGMP standards from the Ministry of Food and Drug Safety and the pharmacopuncture certification criteria from the Ministry of Health and Welfare of South Korea. The EHD evaluation items were classified into three categories: facilities, quality control, and validation. The evaluation items were compared with the KGMP sterile medicine criteria to determine their conformance with each other, followed by a discussion among the committee of six experts and their consensus to suggest the items to complement the EHD evaluation criteria. Results: Among the KGMP sterile medicine criteria, 44 were related to the management of the facilities, and 32 pharmacopuncture evaluation items corresponded to these KGMP items (66.7%). Fifty-eight KGMP criteria were related to quality management, and 42 pharmacopuncture evaluation items corresponded to these KGMP items (72.4%). Twentyfive KGMP sterile medicine criteria were related to validation, and 11 pharmacopuncture evaluation items corresponded to these KGMP items (44.0%). Sixteen items under the pharmacopuncture EHD criteria corresponded to the KGMP sterile medicine criteria based on the consent of the experts. Among these, 4 were related to facility management, 6 were related to quality control, and 6 were related to validation. Conclusion: For the safety and quality control of pharmacopuncture, there is a need to select the criteria for the mandatory items among the proposed pharmacopuncture-EHD criteria laws and systems to ensure that the pharmacopuncture materials are produced under the pharmacopuncture-EHD in compliance with the relevant requirements. More studies are needed to secure the safety level of pharmacopuncture materials corresponding to that of conventional medicine.

Comparison and The Evaluation of Criteria for Arousal Level Control (SIC에 의한 각성도 제어를 위한 평가기준의 설정 및 비교)

  • Ko, H.W.;Kim, Y.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.372-376
    • /
    • 1996
  • This paper describes the criterias to evaluate arousal states of subject and these are applied to contort arousal level. Correction factor was introdued to compensate under or over evaluated Nz due to the different initial basal skin impedance. These criteria and correction factor were worked well to increase the arousal level.

  • PDF

Improvement and Application of Assessment Criteria on Disease Control Level in Olive Flounder Aquaculture Farms (넙치 양식장의 질병관리등급 평가기준 개선 및 적용)

  • CHO, Miyoung;HA, Heon-Ju;MIN, Jin-Gi;KIM, Tae-Jin;JEE, Bo-Young;PARK, Shin-Hoo;HWANG, Seong-Don;KIM, Kwang-il;JANG, Yeounghwan;PARK, Myoung-Ae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.6
    • /
    • pp.1646-1655
    • /
    • 2015
  • Korean government has issued the ratings standard for disease control of aquaculture farms according to the Aquatic Life Disease Control Act in 2008. There are five rating criteria within the enforcement regulations; period of disease free, performance of disinfection, environmental and hygienic management, keeping record of trade and sales, completion of education for disease control. There are no application has been applied on the basis of the rating criteria so far because detailed subcriteria and scoring indicators has not established for assessment process. In order to apply the ratings standard for disease control, we set up the subcriteria and new scoring for rating disease control level based on legal criteria in this study. This study was conducted on 90 targeted olive flounder farms in Jeju. The result of disease control level assessment on olive flounder aquaculture farms show the overall average of Jeju-do was 72.9 points and differed depending on the district; 74.7 in Jeju-si and 71.1 in Seogwipo-si, respectively. The Spearman correlation of each evaluation index show the disease control level score was correlated highly with the performance of disinfection(R=0.715, p<0.01), and environmental and hygienic management(R=0.661, p<0.01). The result of correlation analysis show that there is the highest correlation between the aquaculture farm status and the total mortality(R= -0.618, p<0.01). The reliability of the results are considered to be accurate in the Cronbach's alpha value of 0.727.

User's characteristics on the screen adjustment of color TV (칼라 TV의 화면조정에 관한 사용자 특성)

  • Jeong, Gwang-Tae;Park, Jae-Hui;Yu, Geum-Seon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.81-89
    • /
    • 1999
  • User's characteristics on the screen adjustment of color TV were studied. Two experiments were performed. In the first experiment, the characteristic of screen adjustment according to TV program, ambient luminance, and gender was investigated. Twenty subjects (10 females and 10 males) were participated in this experiment. Set points of brightness, contrast, tint, and color were measured on TV screen and analyzed. Brightness and contrast were significant on gender at significant level 0.01 and color was significant on gender at significant level 0.1. Tint was significant on program at significant level 0.01. The second experiment was performed to supplement the first experiment. The influences of ambient luminance, presented image, screen setting criteria, and gender were investigated. We simplified the first experiment in the second one. We restricted dependent variables (screen control variables) to only two, brightness and contrast. Other control variables were fixed to middle values. Brightness and contrast were significant on gender and screen setting criteria at significant level 0.01. In conclusion, we found that ambient luminance and presented image had no significant effects on TV screen adjustment and TV program had only a significant effect on tint. However, we found that gender and screen setting criteria had significant effects in most conditions.

  • PDF

Boarding Environment of Training Ship KAYA to the Noise during the Voyage (실습선 가야호의 항해 중 선내 소음에 대한 승선환경)

  • Kim, Min-Son;Shin, Hyeon-Ok;Kim, Min-Seok;Hwang, Bo-Kyu
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.22 no.2
    • /
    • pp.218-230
    • /
    • 2010
  • This study was conducted to determine the effect of the noise level on the boarding environment in a stern trawl ship, KAYA(GT: 1,737 tons, Pukyong National University). We measured the noise level at a working, an accommodation and a teaching area, and an engine space on January 9, 2010 while the KAYA was sailing on a liner sea route. At the working area, the ranges of the noise rating number(NRN) and the NRN determination frequency(FNRN) were from 44 to 73 and from 1000 to 2000Hz, respectively. The results were generally satisfied the criteria of the International Maritime Organization(IMO). The noise level at the area, except the radio room(w2), was exceeded the criteria(50dB(A)) for the efficient studying and working. The noise level at the engine control room and the machine workshop was respectively exceeded 1.2dB and 9.5dB than the criteria caused the conversation disturbance (70dB(A)). At the accommodation, NRN and FNRN were from 49 to 54 and from 1000 to 4000Hz, respectively. The noise level was below the criteria of IMO, but above 40dB(A) caused the sleep disturbance. At the teaching area, NRN and FNRN were from 44 to 63 and from 500 to 2000Hz, respectively. The noise level was exceeded than the criteria(50dB(A)) for the efficient studying. At the engine space, NRN and FNRN were from 95 to 100 and from 2000 to 4000Hz, respectively. The noise level was above the criteria of IMO(90dB(A)) for the residence, while it was not exceeded 110dB(A) for the transient.

ICAN, I3A Design Criteria for Military Defense Command & Control Facilities (국방 지휘·통제 시설을 위한 ICAN, I3A 설계기준)

  • Jo, Yun-Jeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.4
    • /
    • pp.806-815
    • /
    • 2017
  • Korean Ministry of National Defense has criteria for military facilities but most were made with the focus on design criteria of facilities and especially in the case of information and communication, only overall criteria with the level of conceptual design are suggested without details. By comparing the design standards of ICAN and I3A that are applied in US Department of Defense, this study will suggest the desirable design standard of Korean military on command/control facilities and general/administrative facilities.

Improvement of National Risk Alarm 4-Stage Criteria for Flood Disaster (홍수재난 대응을 위한 국가위기경보 4단계 설정기준 개선)

  • Lee, Sookyong;Park, Jae-Woo;Oh, Eun-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.3
    • /
    • pp.369-377
    • /
    • 2018
  • EAP, which is operated on the frame of Risk Alarm 4-stage of National Risk Management Guideline, is a critical method in order to promptly respond to disasters. Korea Flood Control Office issues major and moderate flood alarm at each river station by respectively 50% and 70% of design flood discharge in terms of watermark or sea level, however, the criteria deciding major and moderate floods are vague for field managers to control the disaster situations. On the other hand, Japan and USA use river water level as a main criterion in order to classify the stage of flood disaster, which is higher design flood level than Korea. Thus, the authors analyzed domestic and oversea EAP guidelines and suggested improved criteria showing easy display method and raising the criteria of flood level for reflecting more effective action plans through testing a simulation training on the test-bed.

Decision Making for the Industrial Security Management Measures' Importance in Operation Level (운영 수준에서의 산업보안 관리대책 중요도 결정)

  • Chae, Jeong-Woo;Jeong, Jin-Hong
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.4
    • /
    • pp.389-398
    • /
    • 2013
  • This study aims to support rational security investment decision making through prioritizing on operational level of management measures strategically, in carrying out industrial security activities. For this, AHP survey is conducted against industrial security professionals and analyzed. Thereafter, the importance and the priority of industrial security management measures are determined. As a result, in a comparison evaluation among the criteria, 'ICT service management' represents the highest weight (0.54). And the sub-criteria could be divided into three groups (Group I, II, III), depending on their importance. The sensitivity analysis results show that if the weight of the criterion, 'ICT systems/networks access control' is doubled, the sub-criteria, 'O/S access control', 'application access control', and 'wired/wireless network access control' are enter into top rank group. In case of the criterion, 'physical/environmental security' is doubled, the sub-criteria, 'protection zoning/access control' and 'disaster prevention on business equipment/counter-terrorism' are enter into the top rank group, 'securing utilities' is enter into the mid rank group.

Case Study : Application of Specific Evaluation Criteria For Safety Circuit Design of EN ISO 13849-1 (사례 연구 : EN ISO 13849-1의 안전회로 설계를 위한 구체적 평가 기준의 적용)

  • Jung, Hwansuk;Lee, Dongju
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.1
    • /
    • pp.94-101
    • /
    • 2018
  • With the development of industrial technology and science, production and manufacturing facilities have been enhanced and improved, and the importance of the safety of workers has also been regulated and limited by various safety management methods. As a way to secure the safety of the workers from the production facility, the fail-safe and fool-proof methods are now being applied. Any possible insecure behavior and unsafe conditions can be removed by adopting the standards and specifications that are now secure the safety of workers and equipment. This research analyzes EN ISO 13849-1 international and European standards during CE certification. In order to secure acceptable reduced risks, the risk assessment process of ISO 12100 and the processes for reducing its risk are applied. In the current ISO 13849-1 standard, the criteria for the required performance level PLr (Required Performance Level) for the applicable risk and safety functions through the risk assessment are subjective and not subdivided. Therefore, the evaluation criteria are likely to cause judge's judgement error due to qualitative judgement. This research focuses on evaluation and acceptable performance level setting for the safety circuit of the equipment. We propose an objective and specific evaluation criteria to secure safety, and the proposed evaluation criteria are applied to the case study of the safety circuit for the equipment. In order to secure the safety of the entire safety circuit, the improvement of the MTTFd and DC level related to the SRP/CS (Safety-Related Parts of Control Systems)' lifetime is required for the future research.