• Title/Summary/Keyword: level meter

Search Result 484, Processing Time 0.031 seconds

Noise Generation Characteristic for Tunnel Construction Equipments (건설장비에 의한 터널작업의 소음환경 실태)

  • Jang, Jae-Kil;Kim, Kab Bae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.9
    • /
    • pp.841-849
    • /
    • 2013
  • Workers engaged in construction works have been exposed to high levels of noise during their work in tunnels. Noise is one of the major health hazards for employees working in construction sites. The aim of this study is to evaluate the noise levels generating from tunneling equipments such as jumbo drills, backhoes, payloaders, shotcrete machines and service cars. Explosion and turbo fan noises were also monitored. A high precision sound level meter was introduced for measuring LAeq, LAFmax, LAFmin and LCpeak noises in 5 tunneling work sites that were located in Seoul, Kyunggi-do and Kangwon-do areas with NATM and shield methods. The highest noise was recorded by explosion(151.9 dB LCpeak) followed by jumbo drills of higher than 110 dB(A) LAeq. Backhoe normally generated 90~110 dB(A) LAeq while breaking work of rock showed additional around 5~15 dB(A). Noise exposure levels for payloader and shotcrete machine scored more than 90 dB(A) which might be a source of noise-induced hearing loss. Additional research in revealing noise levels from construction equipments operating in tunneling works may enhance the protection of workers who exposed to noise primarily at the sites.

Warpage Simulation by the CTE mismatch in Blanket Structured Wafer Level 3D packaging

  • Kim, Seong Keol;Jang, Chong-Min;Hwang, Jung-Min;Park, Man-Chul
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.1
    • /
    • pp.168-172
    • /
    • 2013
  • In 3D wafer-stacking technology, one of the major issues is wafer warpage. Especially, The important reason of warpage has been known due to CTE(Coefficient of Thermal Expansion) mismatch between materials. It was too hard to choose how to make the FE model for blanket structured wafer level 3D packaging, because the thickness of each layer in wafer level 3D packaging was too small (micro meter or nano meter scale) comparing with diameter of wafer (6 or 8 inches). In this study, the FE model using the shell element was selected and simulated by the ANSYS WorkBench to investigate effects of the CTE on the warpage. To verify the FE model, it was compared by experimental results.

Vascular Anatomy of Peroneal Perforator Flap (비골 동맥 천공지 피판의 혈관 해부학)

  • Chung, Duke Whan;Han, Chung Soo;Hwang, Joon Sung
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.36-42
    • /
    • 2004
  • Materials and Methods: We studied 50 cases of peroneal perforating branch about branching pattern, course, length of vascular pedicle, and perforating level of the perforating cutaneous branches from Oct. 1985 to November 2003 by doppler flow meter and intraoperative findings. Results: 1) The perforating cutaneous branches were classified into four types, the Straight Branch (27cases), the Proximal Oblique Branch (11cases), the Branch from Muscular Artery (10cases), the Distal Oblique Branch(2 cases) respectively. The most common patten was Straight Branch, that was 54%. 2) There were 3 pathways of these branches, the most common one passed between the Soleus and Peroneus muscles(34 cases, 68%) 3) The length of vascular pedicle in Buoy Flap was variable from from 3 cm to 15 cm, but 32 cases(64%) were distributed between 5 cm and 6 cm. 4) The perforating level of branches were 5.9 cm in average from fibular neck to subcutaneous perforator artery 5) Peroneal Buoy Flap in possible to reconstruct both seperated bone and skin defect in some distance by One-Stage Operation and we can harvest maximal $8{\times}16cm$ sized flap in one perforating artery. If we include more two perforating artery, we get more wide flap which can cover large defect.

  • PDF

Tendency of Calibration and Test for Acoustic Field in KRISS (KRISS에서 수행된 음향관련 교정 및 시험 동향)

  • 서재갑;권휴상;정성수;조문재;서상준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.448-452
    • /
    • 2002
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 2001. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

Dynamics and Distribution of Quercus gilva Blume Population in Korea (국내 개가시나무 개체군의 분포 및 동태)

  • Hyun, Hwa-Ja;Song, Kuk-Man;Choi, Hyung-Soon;Kim, Chan-Soo
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.4
    • /
    • pp.385-392
    • /
    • 2014
  • Quercus gilva Blume is an evergreen-leaved tree that belongs to Facaceae and grows in tropical and warm-temperate regions, such as Japan, Taiwan, China and Korea. This study was carried out to analyze the distribution and growth characteristics of Q. gilva in the native range. In Korea, this species was distributed in Jeju Island between 80 and 350 meter above sea level, and mainly in the south-western regions of the island from 100 to 200 meter above sea level. The average height of Q. gilva was $9.8{\pm}1.9$ meter, with most trees 9 and 12 meter tall. The average diameter at breast height was $22.6{\pm}6.8$ centimeter, with the majority between 20 and 30 centimeter. Several coppice shoots ($3.8{\pm}2.1$ pieces) were formed from stumps and inferred by frequent cuttings for use. Almost Q. gilva individuals(96.2%) were covered with kinds of vines(18 species), and evergreen Trachelospermim asiaticum (Siebold et Zucc.) Nakai was major species. The analysis of damage of vines revealed that the most dead branches were found with 9 to 12 meter height of Q. gilva, and the more vines attached, the larger damage to Q. gilva individuals. A continuous monitoring and investigation would be required to preserve this species in their habitats.

Correlation between Determining Values of Sectional Equilibrium Moisture Contents of Larix leptolepis and Populus euramericana I - 476 grown in Mt. Jiri (지리산산(智異山産) 일본 잎갈나무재(材)와 포플러재(材)의 단면별(斷面別) 평형함수율(平衡含水率)(EMC) 측정치(測定値)와 그 상관성(相關性))

  • Hwang, Jeung;Moon, Chang Kuck
    • Journal of Korean Society of Forest Science
    • /
    • v.59 no.1
    • /
    • pp.63-66
    • /
    • 1983
  • Sectional equilibrium moisture contents of Larix leptolepis and Populus euramericana I-476 were determined, their correlations and significances were investigated. Among the ovendry moisture contents. electric moisture meter determining values and the estimative values through chemical equilibria formula, there were significant correlations, 1-5% level, at whole sections in Larix leptolepis. However, in Populus euramericana there was only significant correlation between ovendry moisture content values and electric moisture meter determining values.

  • PDF

A Study on the Implementation of Geographic Information System for an Intelligent Power Distribution Network with Location Informations of Power Line Communication-based Automatic Meter Reading System (전력선통신 기반 저압원격검침 시스템의 공간 정보를 활용한 지능형 배전망 지리정보시스템 구축에 관한 연구)

  • Seo, Chung-Ki;Lee, Seung-Gol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.365-369
    • /
    • 2015
  • In this paper, geographic information system(GIS) for an intelligent power distribution network was implemented with location informations acquired from automatic meter reading system, where the location informations of power line communication(PLC) modems installed at customer side were collected at data concentration units(DCUs) of headend equipment via PLC and then were transmitted to front end processor server. By displaying the connection status of the power distribution network on GIS map, operation of advanced metering infrastructure(AMI) or management of power grid system could be performed intuitionally and in real time, because the configuration state of the power grid could be easily monitored. The feasibility of the proposed system was confirmed with the especially constructed laboratory-level test bed and the verification test of the system will be carried out for a real power distribution network.

Prototype Milli Gauss Meter Using Giant Magnetoimpedance Effect in Self Biased Amorphous Ribbon

  • Kollu, Pratap;Yoon, Seok-Soo;Kim, Gun-Woo;Angani, C.S.;Kim, Cheol-Gi
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.194-198
    • /
    • 2010
  • In our present work, we developed a GMI (giant magnetoimpedance) sensor system to detect magnetic fields in the milli gauss range based on the asymmetric magnetoimpedance (AGMI) effect in Co-based amorphous ribbon with self bias field produced by field-annealing in open air. The system comprises magnetoimpedance sensor probe, signal conditioning circuits, A/D converter, USB controller, notebook computer, and program for measurement and display. Sensor probe was constructed by wire-bonding the cobalt based amorphous ribbon with dimensions $10\;mm\;{\times}\;1\;mm\;{\times}\;20\;{\mu}m$ on a printed circuit board. Negative feedback was used to remove the hysteresis and temperature dependence and to increase the linearity of the system. Sensitivity of the milli gauss meter was 0.3 V/Oe and the magnetic field resolution and environmental noise level were less than 0.01 Oe and 2 mOe, respectively, in an unshielded room.

Adaptive TMS Variable Area Flow Meters (적응형 TMS 면적식 유량계)

  • Kwak, Doo-Sung;Kim, On;Cho, Ki-Ryang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.3
    • /
    • pp.590-595
    • /
    • 2008
  • A new adaptive TMS variable area flow meter that is used to the environment measuring equipment is proposed. This system is consist of a ball moving within the tube line which corresponds to gas flow and photo sensor array which monitoring the movement of ball. This system can monitoring the position of bali in case of the very few gas flow in various levels. And it can automatically adjust the gas flow at the highest and the lowest level to prevent the tube line blockage.