• 제목/요약/키워드: level gauge

검색결과 244건 처리시간 0.02초

고로 용융물 레벨 변화 추정을 위한 디지털 필터 설계 (The Design of Filter for Hearth Liquid Level Estimation in Blast Furnace)

  • 조내수;한무호;권우현;최연호
    • 센서학회지
    • /
    • 제21권1호
    • /
    • pp.75-81
    • /
    • 2012
  • Optimizing the tapping time of a blast furnace is important to a stable operation and life extension. To optimize the tapping time of the blast furnace, the location of Hearth Liquid Level should be recognized. There are several ways to measure the hearth liquid level in the blast furnace, such as Electromotive Force(EMF) measurement, pressure measurement by putting in nitrogen probe and manometry with strain gauge. In this paper, it will be discussed using strain gauge among the three methods. Conventional strain gauge must be revised periodically. Since, internal pressure, temperature of internal refractory material and wind pressure have effect on the strain gauge. However, static pressure value is required to compensate. To solve these problems, this paper suggests finding relationship between Hearth Liquid Level and strain gauge output, adding digital filter in strain gauge. Using the proposed method, it was possible to estimate the hearth liquid level and determine the appropriate tapping time. Usefulness of the proposed method through simulations and experimental results are confirmed.

조위 및 수온, 염분 데이터를 이용한 동해 연안의 해수면 변화 (Long-term Change in Sea Level along the Eastern Coastal Waters of Korea using Tide Gauge, Water Temperature and Salinity)

  • 박세영;이충일
    • 한국환경과학회지
    • /
    • 제23권5호
    • /
    • pp.801-806
    • /
    • 2014
  • Long-term change in sea level along the eastern coast of Korea was illustrated using four tide-gauge station (Pohang, Mukho, Sokcho, Ulleung) data, water temperature and salinity. Seasonal variation in the sea level change was dominant. The sea level change by steric height derived from water temperature and salinity was relatively lower than that measured from the tide-gauge stations. Sea level rising rate per year by steric height increased with latitude. The effect of salinity(water temperature) on the sea level change is greater in winter(in summer).

특정 레벨을 검출하기 위한 2단 Magnetic Float 타입 레벨 게이지의 최적 설계에 관한 연구 (Optimal design of dual magnetic float type level gauge to detect a specific level)

  • 김동석;한재만;박관수
    • 센서학회지
    • /
    • 제17권4호
    • /
    • pp.308-316
    • /
    • 2008
  • For the measurement of liquid level in ship's cargo tank, ballast tank, fuel oil tank and fresh water tank, several types of gauge meter are used such as tubular type, magnetic float type, reflex type transparent type and welding pad type. Among them, magnetic float type gauge meter is environmental friendly device because it is free of power source and maintenance. The main obstacle of the device is relatively large error bound. In this paper, finite element method is used to design and analysis of the magnetic float type gauge meter. The operation of reed switch according to the magnetic field has been successfully described and agreed well with experimental measurement. The optimum geometry with combination of permanent magnet and reed switches are designed to achieve 98 % accuracy of fluid level.

차압센서를 이용한 극저온 액화가스 저장용기의 액면측정장치 설계에 관한 연구 (A study on designing a level gauge for cryogenic liquefied storage vessel by using a differential pressure sensor)

  • 최동준;임형일;도덕희;조종래
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.384-390
    • /
    • 2013
  • 최근 반도체, LCD, 첨단전자산업 관련 분야의 급팽창으로 고압 액화가스 사용이 증가함에 따라 극저온 용기 및 저장탱크도 대형화되는 추세이다. 저장탱크 내의 잔존량을 측정하기 위해 기존에는 아날로그식 액면계와 압력계를 이용하고 있으나 이는 측정이 불편하고 정밀도가 부정확하여 정확한 양을 측정하기가 어렵다. 이에 본 연구에서는 차압센서를 이용하여 극저온 액화가스 저장탱크의 압력과 액면 높이를 측정하고 유선통신기능으로 PC 모니터링이 가능하도록 하며, 모바일 프린터를 연결하여 특정데이터가 출력 가능하도록 디지털식 액면측정장치를 설계한다.

남인도양에서의 해수면에 대한 위성자료(Topex/Poseidon 고도계)와 현장자료(Tide Gauge 해면계)간의 비교 (Comparison of Topex/Poseidon sea levels data and Tide Gause sea levels data from the South Indian Ocean)

  • 윤홍주;김상우;이문옥;박일흠
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 추계종합학술대회
    • /
    • pp.281-285
    • /
    • 2001
  • According to standard procedures as defined in the users handbook for sea level data processes, I was compared to Topex/poseidon sea level data from the first 350days of mission and Tide Gauge sea level data from the Amsterdam- Crozet- Kerguelen region in the South Indian Ocean. The comparison improves significantly when many factors for the corrections were removed, then only the aliased oceanic tidal energy is removed by oceanic tide model in this period. Making the corrections and smoothing the sea level data over 60km along-track segments and the Tide Gauge sea level data for the time series results in the digital correlation and RMS difference between the two data of c=-0.12 and rms=11.4cm, c=0.55 and rms=5.38cm, and c=0.83 and rms=2.83cm for the Amsterdam, Crozet and Kerguelen plateau, respectively. It was also found that the Kerguelen plateau has a comparisons due to propagating signals(the baroclinic Rossby wave with velocity of -3.9~-4.2cm/sec, period of 167days and amplitude of 10cm) that introduce temporal lags($\tau$=10~30days) between the altimeter and tide gauge time series. The conclusion is that on timescales longer than about 10days the RMS sea level errors are less than or of the order of several centimeters and are mainly due to the effects of currents rather than the effects of sterics(water temperature, density) and winds.

  • PDF

블레이드 진동측정을 위한 스트레인 게이지 설치위치 최적화 (Optimal Placement of Strain Gauge for Vibration Measurement for Fan Blade)

  • 최병근
    • 한국소음진동공학회논문집
    • /
    • 제14권9호
    • /
    • pp.819-826
    • /
    • 2004
  • A multi-step optimum strategy for the selection of the locations and directions of strain gauges is proposed in this paper to capture at best the modal response of blade in a series of modes on fan blades. It is consist of three steps including two pass reduction step, genetic algorithm and fine optimization to find the locations-directions of strain gauges. The optimization is based upon the maximum signal-to-noise ratio(SNR) of measured strain values with respect to the inherent system measurement noise, the mispositioning of the gauge in location and gauge failure. Optimal gauge positions for a fan blade is analyzed to prove the effectiveness of the multi-step optimum methodology and to investigate the effects of the considering parameters such as the mispositioning level, the probability of gauge failure, and the number of gauges on the optimal strain gauge position.

Position Optimization of Strain Gauge on Blades

  • Choi, Byeong-Keun;Lee, Hyun-Seob;Yang, Bo-Suk;Mignolet, Marc P.
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.422-427
    • /
    • 2002
  • This paper focuses on the formulation and validation of an automatic strategy for the selection of the locations and directions of strain gauges to capture at best the modal response of a blade in a series of modes. These locations and directions are selected to render the strain measurements as robust as possible with respect to random mispositioning of the gauges and gauge failures. The approach relies on the evaluation of the signal-to-noise ratios of the gauge measurements from finite element strain data and includes the effects of gauge size. A genetic algorithm is used to find the strain gauge locations-directions that lead to the largest possible value of the smallest modal strain signal-to-noise ratio, in the absence of gauge failure, or of its expected value when gauge failure is possible. A fan blade is used to exemplify the applicability of the proposed methodology and to demonstrate the effects of the essential parameters of the problem, i.e. the mispositioning level, the probability of gauge failure, and the number of gauges.

  • PDF

협대역 FMCW 레이더를 이용한 고해상도 레벨게이지 (High Resolution FMCW Level Gauge with Narrowband FMCW Radar)

  • 엄승현;오우진
    • 한국정보통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.899-905
    • /
    • 2012
  • FMCW 레이더 방식의 레벨게이지는 비 접촉성, 원거리 계측과 다양한 형상으로 구현이 가능한 장점 때문에 많은 연구와 개발이 되어왔으나 cm급의 고 해상도를 얻기 위해서는 GHz의 넓은 대역폭이 필요한 단점이 있다. 본 논문에서는 협대역 시스템으로 광대역 성능을 얻을 수 있는 톱니파 형태의 송신 파형을 제안하였다. 이 방식은 STFT(Short-time fourier transform)로 짧은 구간으로 나누어 처리하고 단일 정현파의 주파수 추정 알고리즘으로 해상도를 개선하고 있으며 실험을 통하여 300MHz의 FMCW레이더에서 8배까지 거리해상도가 개선되는 것을 보였다.

계측기오차 보상을 위한 압축한계 설정에 관한 연구 (Research of Determining the Compressed Gauge Limit Compensating for Guage Error)

  • 이종성;고숭호
    • 산업기술연구
    • /
    • 제22권B호
    • /
    • pp.89-93
    • /
    • 2002
  • When testing products before shipment to the customer, quality characteristics are measured to decide whether or not their values are between the specification limits. Unfortunately, this testing procedure can lead to incorrect decisions because of gauge error. That is, good products can erroneously be qualified as bad, and bad products as good, and this has consequences for producer's and consumer's risk. In cases of such as this, the compressed gauge limit can be used to achieve the desired product quality level dictated by the manufacturer or the customer. A compressed gauge limit is a limit set by the manufacturer on a test gauge that is tighter than the specification limit established by the customer. The compressed gauge limits should be set at levels to achieve the defect levels desired by the customer and simultaneously minimize the loss of good product that is rejected due to errors in the gauges. In this article, the models for determining the defect levels and the losses obtained by adding compressed gauge limits will be developed. A response surface model approach is utilized which allows an optimal operating condition to be generated relatively easily.

  • PDF

진동측정을 위한 스트레인 게이지 설치위치 최적화 : 최적화 방법 및 평가 (Optimal Placement of Strain Gauge for Vibration Measurement : Formulation and Assessment)

  • 최창림;양보석;최병근
    • 한국소음진동공학회논문집
    • /
    • 제14권8호
    • /
    • pp.757-766
    • /
    • 2004
  • This paper focuses on the formulation and validation of an automatic strategy to select the optimal location and direction of strain gauges for the measurement of the modal response. These locations and directions are important to render the strain measurements as robust as possible when a random mispositioning of the gauges and gauge failures are expected. The approach relies on the evaluation of the signal-to-noise ratios of the gauge measurements from strain data of finite element. The multi-step optimization strategy including genetic algorithm is used to find the strain gauge locations-directions that maximize the smallest modal strain signal-to-noise ratio in the absence of gauge failure or its expected value when gauge failure is possible. A flat Plate is used to prove the applicability of the proposed methodology and to demonstrate the effects of the essential parameters of the problem such as the mispositioning level, the probability of gauge failure, and the number of gauges.