Browse > Article
http://dx.doi.org/10.5369/JSST.2012.21.1.75

The Design of Filter for Hearth Liquid Level Estimation in Blast Furnace  

Cho, Nae-Soo (School of Electrical Engineering, Kyungpook National Unversity)
Han, Mu-Ho (System Solutions Research, RIST)
Kwon, Woo-Hyen (School of Electrical Engineering, Kyungpook National Unversity)
Choi, Youn-Ho (Division of Robotics System, Daegu Gyeongbuk Institute of Science and Technology)
Publication Information
Abstract
Optimizing the tapping time of a blast furnace is important to a stable operation and life extension. To optimize the tapping time of the blast furnace, the location of Hearth Liquid Level should be recognized. There are several ways to measure the hearth liquid level in the blast furnace, such as Electromotive Force(EMF) measurement, pressure measurement by putting in nitrogen probe and manometry with strain gauge. In this paper, it will be discussed using strain gauge among the three methods. Conventional strain gauge must be revised periodically. Since, internal pressure, temperature of internal refractory material and wind pressure have effect on the strain gauge. However, static pressure value is required to compensate. To solve these problems, this paper suggests finding relationship between Hearth Liquid Level and strain gauge output, adding digital filter in strain gauge. Using the proposed method, it was possible to estimate the hearth liquid level and determine the appropriate tapping time. Usefulness of the proposed method through simulations and experimental results are confirmed.
Keywords
Hearth Liquid Level; Blast Furnace; EMF; Strain Gauge; Digital Filter;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Nae-Soo Cho, Joo-Hwan Kim, Kyoung-Seop Youn, and Woo-Hyen Kwon, "The design of code detector for sell call radio buoy", JSST, vol. 20, no. 3, pp. 199-206, 2011.
2 Yu J.S., Kim S.H., Lee B. bK., Won C.Y., and Hur J., "On-line wear determination for improved lifetime of blast furnace hearth based on heat-flux meters", METEC Congress 03 and 3rd International Conference on Science and Technology of Ironmaking, pp. 491-495, Dusseldorf, 2003.
3 정진수, 정진경, 김성만, "고로 용융물 레벨 변화가 노하부 기전력에 미치는 영향", 대한금속학회 논문지, vol. 36, no. 5, pp. 796-800,1998.
4 Danloy, G., Stolz, C., Crahay, J., and Dubois, P., "Measurement of iron and slag level in the blast furnace hearth", Proceedings of the 58th Ironmaking Conference, pp. 89-98, Chicago Illinois, USA, 1999.
5 L.-F. Sancho, R.-P.Chust, and D.Carrascal, "New technique for abnormal casting identification in a blast furnace", ATS International Steelmaking Conference, pp. 23-28, Paris, 2006.
6 Jan TORRKULLA, Johnny BRANNBACKA, Henrik SAXEN, and Matias WALLER, "Indicators of the internal state of the blast furnace hearth", ISIJ International, vol. 42, no. 5, pp. 504-511, 2002.   DOI
7 http://www.crmgroup.be/
8 Ala an V. Oppenheim, Ronald W. Schafer with Jon R. buck, DISCRETE-TIME SIGNAL PROCESSING 2nd edition, Prentice Hall, New Jersey, pp. 240-300, 1985.