• 제목/요약/키워드: lens process

검색결과 560건 처리시간 0.028초

Optical MEMS 응용을 위한 광학 설계 (Characterization of Optical Design for Optical MEMS)

  • 엄용성;박흥우;박준희;최병석;이종현;윤호경;최광성;문종태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.193-197
    • /
    • 2003
  • As one of the core technologies in the field of the optical communication with WDM, the optical cross connector with movements of micro mirrors is getting important day by day. The packaging structure of 2-dimensional NxN MOEMS switch should be determined by the harmonization of the following items such as the geometrical compatability between optical and structural components, the characteristics of optical input and output parts with device, and the electrical performance for the operation of micro mirrors. Therefore, the packaging process could be defined as the integrated technology completed by the optical and electrical science and the material science for the understanding of its thermo-mechanical properties with packaging materials. In the present study, the harmonization between the optical and structural components as well as the optical characteristics of lens system used will be investigated.

  • PDF

백색 LED용 저 연화점 유리를 이용한 색 변환 렌즈의 제조 조건에 따른 광 특성 (Optical Properties as Process Condition of Color Conversion Lens Using Low-softening Point Glass for White LED)

  • 채유진;이미재;황종희;임태영;김진호;정희석;이영식;김득중
    • 한국세라믹학회지
    • /
    • 제50권6호
    • /
    • pp.454-459
    • /
    • 2013
  • Recently, remote phosphors have been reported for application to white LEDs to provide enhanced phosphor efficiency compared with conventional phosphor-based white LEDs. In this study, a remote phosphor was produced by coating via screen printing on a glass substrate with different numbers of phosphor coating. The paste consists of phosphor, lowest softening glass frits, and organic binders. The remote phosphor could be well controlled by varying the phosphor content rated paste. After mounting the remote phosphor on top of a blue LED chip, CCT, CRI, and luminance efficiency were measured and values of 5300 K, 62, and 117 lm/W were respectively obtained in the 80 wt% phosphor with 3 coating layers sintered at $800^{\circ}C$.

의료용 초음파 트랜스듀서의 방사 빔 형상 개선 (Improvement of the Radiation Beam Profile of a Medical Ultrasonic Transducer)

  • 박연수;이원석;노용래
    • 한국음향학회지
    • /
    • 제34권4호
    • /
    • pp.264-273
    • /
    • 2015
  • 본 논문에서는 의료용 초음파 트랜스듀서의 방사 빔 형상의 개선에 관하여 연구하였다. 빔 형상의 개선을 위하여 분할전극과 다초점 렌즈를 포함하는 새로운 트랜스듀서 구조를 고안하였다. 먼저 선형 음원에 대해 유한요소 해석을 통해 빔 형상을 분석한 후, 부엽의 크기, 집속구간 및 빔폭 등의 성능들을 동시에 고려하여 고안된 구조의 최적설계를 수행하였다. 이때 집속구간과 최소 빔폭의 비율을 성능지수로 사용하여 고안된 구조의 최적치수를 도출하였다. 그 결과 부엽의 크기가 -20.2 dB로 작고, 최소 빔폭이 2.04 mm이고 깊이 30 mm부터 160 mm까지 좁고 일정한 빔폭을 가지도록 빔 형상이 개선되었다. 나아가, 고안된 구조를 가지도록 트랜스듀서 시편을 제작하고 빔 패턴을 측정하여 해석 결과와 비교함으로써, 고안된 트랜스듀서 구조의 타당성을 검증하였다.

Estimating Organ Doses from Pediatric Cerebral Computed Tomography Using the WAZA-ARI Web-Based Calculator

  • Etani, Reo;Yoshitake, Takayasu;Kai, Michiaki
    • Journal of Radiation Protection and Research
    • /
    • 제46권1호
    • /
    • pp.1-7
    • /
    • 2021
  • Background: The use of computed tomography (CT) device has increased in the past few decades in Japan. Dose optimization is strongly required in pediatric CT examinations, since there is concern that an unreasonably excessive medical radiation exposure might increase the risk of brain cancer and leukemia. To accelerate the process of dose optimization, continual assessment of the dose levels in actual hospitals and medical facilities is necessary. This study presents organ dose estimation using pediatric cerebral CT scans in the Kyushu region, Japan in 2012 and the web-based calculator, WAZA-ARI (https://waza-ari.nirs.qst.go.jp). Materials and Methods: We collected actual patient information and CT scan parameters from hospitals and medical facilities with more than 200 beds that perform pediatric CT in the Kyushu region, Japan through a questionnaire survey. To estimate the actual organ dose (brain dose, bone marrow dose, thyroid dose, lens dose), we divided the pediatric population into five age groups (0, 1, 5, 10, 15) based on body size, and inputted CT scan parameters into WAZA-ARI. Results and Discussion: Organ doses for each age group were obtained using WAZA-ARI. The brain dose, thyroid dose, and lens dose were the highest in the Age 0 group among the age groups, and the bone marrow and thyroid doses tended to decrease with increasing age groups. All organ doses showed differences among facilities, and this tendency was remarkable in the young group, especially in the Age 0 group. This study confirmed a difference of more than 10-fold in organ doses depending on the facility and CT scan parameters, even when the same CT device was used in the same age group. Conclusion: This study indicated that organ doses varied widely by age group, and also suggested that CT scan parameters are not optimized for children in some hospitals and medical facilities.

Study on terahertz (THz) photoconversion technology based on hyperfine energy-level splitting of Positronium (Ps) generated from relativistic electron beams

  • Sun-Hong Min;Chawon Park;Ilsung Cho;Minho Kim;Sukhwal Ma;Won Taek Hwang;Kyeong Min Kim;Seungwoo Park;Min Young Lee;Eun Ju Kim;Kyo Chul Lee;Yong Jin Lee;Bong Hwan Hong
    • 대한방사성의약품학회지
    • /
    • 제6권2호
    • /
    • pp.102-115
    • /
    • 2020
  • In the state of Positronium (Ps), which is an unstable material created by the temporary combination of electrons and positrons, the imaging technology through photo-conversion methodology is emerging as a new research theme under resonance conditions through terahertz electromagnetic waves. Normally, Positronium can be observed in the positron emission computed tomography (PET) process when an unstable, separate state that remains after the pair annihilation of an electron and a positron remains. In this study, terahertz (THz) waves and Cherenkov radiation (CR) are generated using the principle of ponderomotive force in the plasma wake-field acceleration, and electrons and positrons are simultaneously generated by using a relativistic electron beam without using a PET device. We confirm the possibility of Positronium photoconversion technology in terahertz electromagnetic resonance conditions through experimental studies that generate an unstable state. Here, a relativistic electron beam (REB) energy of 0.5 MeV (γ=2) was used, and the terahertz wave frequencies is G-band. Meanwhile, a THz wave mode converting three-stepped axicon lens was used to apply the photoconversion technology. Through this, light emission in the form of a luminescence-converted Bessel beam can be verified. In the future, it can be used complementarily with PET in nuclear medicine in the field of medical imaging.

일개 대학병원의 환자군별 진료서비스 변이와 포괄수가제 적용에 따른 진료수익 변화 (Studies on the variations of hospital use and the changes in hospital revenues of 10 KDRGs under the PPS)

  • 전기홍;송미숙
    • 보건행정학회지
    • /
    • 제7권1호
    • /
    • pp.100-124
    • /
    • 1997
  • In order to suggest the strategies for participation in the PPS(Prospective Payment System), analyses were performed based on variations in utilization pattern and changes in revenues of hospitals in 10 selected KDRGs. The data was collected from the claims data of a tertiary hospital in Kyunggido from September 1, 1995 to August 31, 1996. The studies consisted of 1, 718 inpatients diagnosed for lens procedures, tonsilectomy &/or adenoidectomy, appendectomy with complicated principal diagnosis, Cesarean section, or vaginal delivery without any complications. The resources used in each KDRG were measured including average length of stay, total charges, number of orders, intensity of medical services, frequencies of medical services, the rate of non-reimbursable charges, and the rate of non-reimbursable orders. Then, the changes in hopital revenues due to the composition of medical fee schedules under the PPS were estimated as follows: 1) The variations in average lenght of stay, total charges, number of orders, the intensity of medical services, the frequency of medical services, the rate of non-reimbursable charges, and the rate of non-reimbursable orders among the 10 KDRGs were comparatively small. 2) The average lenght of stay was the longest(6.0 days) for appendectomy with complicated principal diagnosis, while it was the shortest(2.1 days) for two vaginal deliveries. Statistically differences existed in the average length of stay among physicians and among the dates of admission in several KDRGs. 3) The total charges were the highest for lens procedures(1, 716, 000 won), while the lowest charges were for two vaginal deliveries(558, 000 won). Statistically differences in the total charges were found among physicians in several KDRGs: however, there were no differences with the dates of admission. 4) The number of orders was the greatest(155) for appendectomy with complicated principal diagnosis, while it was the smallest(75) for the two vaginal deliveries. Statistical differences in the number of orders did not exist among physicians in the KDRGs. 5) Significant differences were found in the intensity of medical services, and in the frequency of medical services among physicians in the KDRGs. 6) The rate of non-reimbursable charges for each KDRG was not related to the rate of non-reimbursable orders. The rate of non-reimbursable orders was the highest(36.0%) for lens procedures, while the lowest rate(11.6%) was for appendectomy with complicated principal diagnosis. The rate of non-reimbursable charges was the highest(39.4-39.7%) for vaginal deliveries, while the lowest rate(13.1%) was for tonsillectomy &/or adenoidectomy(<17 ages). 7) If the physician's practicing style were not change under the PPS, the hospital revenuses could be increased by 10%, and the portion of patient payment could be decreased by 1.4-22.4%. However, the non-reimbursable charges for showed little change between two reimbursement systems. Based upon the above findings, this hospital could be eligible for participation in the PPS(Prospective Payment Systm). However, the process of diagnosis and treatment should be standardized, inentifying methods to reduce cost and to assure quality of medical care. Furthermore, consideration should be given to finding ways to increase patient volume.

  • PDF

MBS 방법으로 제작한 집적형 Triplexer의 광학 설계 (Optical Design of the Integrated Triplexer Fabricated by Micro Block Stacking Method)

  • 윤현재;김종혁
    • 한국광학회지
    • /
    • 제22권4호
    • /
    • pp.191-197
    • /
    • 2011
  • 본 논문에서는 FTTH(fiber to the home) 망에 사용되는 $1.55{\mu}m$ 파장의 아날로그 신호 수신과 $1.31{\mu}m/1.49{\mu}m$ 파장의 디지털 신호 송, 수신이 가능한 집적형 Triplexer를 설계하였다. 이 집적형 Triplexer는 세라믹 재질로 정밀 제작한 서브마운트, 레이저 다이오드 홀더, 포토다이오드 홀더를 이용하여 마이크로 볼렌즈, WDM 필터, FP-LD, PIN-PD 등 광부품을 광 축에 자동으로 정렬시키는 micro block stacking 방법으로 제작 가능한 구조로 설계하였으며 code V 소프트웨어를 이용하여 각 부품의 제작 공차와 조립 공차에 따른 초점의 위치 변위를 분석하였다. 공차 분석 결과 송신부에서 초점의 위치 변화에 가장 큰 영향을 주는 것은 LD spot의 위치 변위로 x, y, z 방향으로 각각 ${\pm}25{\mu}m$, ${\pm}25{\mu}m$, ${\pm}30{\mu}m$ 움직였을 때 초점이 최대 $72{\mu}m$ 이동하였으며 수신부의 경우 0.8mm 볼렌즈(아날로그 신호 수신부)와 마이크로 볼 렌즈(디지털 신호 수신부) 위치 변화가 가장 큰 영향을 주는 것을 알 수 있었으며 디지털 신호 수신부의 경우 마이크로 볼 렌즈가 x, y, z 방향으로 각각 ${\pm}55{\mu}m$, ${\pm}5{\mu}m$, ${\pm}55{\mu}m$ 움직였을 때 초점이 최대 $55{\mu}m$ 이동하였다.

호우 영향예보를 위한 수문학적 정량강우예측(HQPF) 개선 연구 (An Improvement Study on the Hydrological Quantitative Precipitation Forecast (HQPF) for Rainfall Impact Forecasting)

  • 신윤후;김성민;지용근;이영미;김병식
    • 한국방재안전학회논문집
    • /
    • 제15권4호
    • /
    • pp.87-98
    • /
    • 2022
  • 최근 짧은 시간 동안 많은 강우가 내리는 국지성 집중호우가 빈번히 발생하고 이로 인한 침수피해가 증가하고 있다. 국지성 집중호우로 인한 피해를 예방하기 위하여 기상청이 제공하는 지역 앙상블 예측시스템(Local ENsemble prediction System, LENS)과 관측자료와 동네예보 자료를 활용한 기계학습과 확률 매칭(Probability Matching, PM) 기법을 이용하여 수문학적 정량강우예측정보(Hydrological Quantative Precipitation Forecast, HQPF)을 개발하였다. 국지성 집중호우로 인한 침수피해 대비를 위한 호우 영향정보로 HQPF를 생산하고 있지만, 낮은 강우강도에 대하여 과대예측하는 경향이 나타났다. 본 연구에서는 HQPF의 예측정확도 향상과 과대예측 성향을 개선하기 위하여 머신러닝 학습자료 기간확대, 앙상블 기법 분석 및 확률매칭(PM) 기법 프로세스 변경을 통하여 HQPF 개선하였다. 개선된 HQPF의 예측성능을 평가하기 위해 2021년 8월 27일 ~ 2021년 9월 3일 장마전선으로 인한 호우 사례를 대상으로 예측성능 검증을 수행하였다. 10 mm 이하의 강우에 대하여 예측정확도가 크게 향상되었고, 관측과 유사한 발생가능성 및 강우영역을 예측하는 등 과대예측 성향이 개선되었음을 확인하였다.

순차이송형 유리렌즈 성형공정에서 비구면 유리렌즈의 최적 성형조건 연구 (A Study on the Optimal Molding Conditions for Aspheric Glass Lenses in Progressive GMP)

  • 정태성;박규섭;윤길상
    • 한국산학기술학회논문지
    • /
    • 제12권3호
    • /
    • pp.1051-1057
    • /
    • 2011
  • 최근 개발된 GMP공정의 활용으로 디지털 카메라, 광저장기기, 각종 전자기기 등의 광응용 기기에서 비구면 유리렌즈가 폭넓게 활용되고 있다. GMP공정은 복잡한 형상의 유리렌즈를 정밀하면서도 경제적으로 생산할 수 있다. 본 연구에서는 다구치 실험계획법을 이용하여 순차이송형 GMP공정에서 비구면 유리렌즈의 성형 조건을 최적화 하였다. 냉각 1단계에서의 압력과 온도, 시간을 3가지 주요 공정변수로 정하였으며, 3캐비티 금형을 이용하여 실험한 결과 순차이송형 유리렌즈 성형공정에서 냉각시간이 비구면 유리렌즈의 형상정밀도(PV)에 가장 큰 영향을 미치는 것을 알 수 있었다.

Removal of mid-frequency error from the off-axis mirror

  • Kim, Sanghyuk;Pak, Soojong;Jeong, Byeongjoon;Shin, Sangkyo;Kim, Geon Hee;Lee, Gil Jae;Chang, Seunghyuk;Yoo, Song Min;Lee, Kwang Jo;Lee, Hyuckee
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.103-103
    • /
    • 2014
  • Manufacturing of lens and mirror using Diamond Turning Machine (DTM) offers distinct advantages including short fabrication time and low cost as compared to grinding or polishing process. However, the DTM process can leave mid-frequency error in the optical surface which generates an undesirable diffraction effect and stray light. The mid-frequency error is expected to be eliminated by mechanical polishing after the DTM process, but polishing of soft surface of ductile aluminum is extremely difficult because the polishing process inevitably degrades the surface form accuracy. In order to increase its surface hardness, we performed electroless nickel plating on the surface of diamond-turned aluminum (Al-6061T6) off-axis mirrors, which was followed by the 6-hour-long baking process at $200^{\circ}C$ for improving its hardness. Then we polished the nickel plated off-axis mirrors to remove the mid-frequency error and measured polished mirror surfaces using the optical surface profilometer (NT 2000, Wyko Inc.). Finally, we ascertained that the mid-frequency error on the mirror surface was successfully removed. During the whole processes of nickel plating and polishing, we monitored the form accuracy using the ultra-high accurate 3-D profilometer (UA3P, Panasonic Corp.) to maintain it within the allowable tolerance range (< tens of nm). The polished off-axis mirror was optically tested using a visible laser source and a pinhole, and the airy pattern obtained from the polished mirror was compared with the unpolished case to check the influence of mid-frequency error on optical images.

  • PDF