• Title/Summary/Keyword: lens process

Search Result 560, Processing Time 0.03 seconds

DPSS UV laser projection ablation of 10μm-wide patterns in a buildup film using a dielectric mask (Dielectric 마스크 적용 UV 레이저 프로젝션 가공을 이용한 빌드업 필름 내 선폭 10μm급 패턴 가공 연구)

  • Sohn, Hyonkee;Park, Jong-Sig;Jeong, Su-Jeong;Shin, Dong-Sig;Choi, Jiyeon
    • Laser Solutions
    • /
    • v.16 no.3
    • /
    • pp.27-31
    • /
    • 2013
  • To engrave high-density circuit-line patterns in IC substrates, we applied a projection ablation technique in which a dielectric ($ZrO_2/SiO_2$) mask, a DPSS UV laser instead of an excimer laser, a refractive beam shaping optics and a galvo scanner are used. The line/space dimension of line patterns of the dielectric mask is $10{\mu}m/10{\mu}m$. Using a ${\pi}$ -shaper and a square aperture, the Gaussian beam from the laser is shaped into a square flap-top beam; and a telecentric f-${\theta}$ lens focuses it to a $115{\mu}m{\times}105{\mu}m$ flat-top beam on the mask. The galvo scanner before the f-${\theta}$ lens moves the beam across the scan area of $40mm{\times}40mm$. An 1:1 projection lens was used. Experiments showed that the widths of the engraved patterns in a buildup film ranges from $8.1{\mu}m$ to $10.2{\mu}m$ and the depths from $8.8{\mu}m$ to $11.7{\mu}m$. Results indicates that it is required to increase the projection ratio to enhance profiles of the engraved patterns.

  • PDF

Physical Properties Variation of Ophthalmic Material in Content of Silver and Platinum Nanoparticle (은 및 백금 나노 입자의 함량에 따른 안 의료용 소재의 물성 변화)

  • Ye, Ki-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.3
    • /
    • pp.310-316
    • /
    • 2010
  • Nanoparticle with antimicrobial property has been applied to various fields. This study added silver/platinum nanoparticles to HEMA (2-hydroxyethylmethacrylate), NVP (N-vinyl pyrrolidone) and MMA (methylmethacrylate) in various concentrations and copolymerized by heating at $70^{\circ}C$ for 40 minutes, $80^{\circ}C$ for 40 minutes, and finally, $100^{\circ}C$ for 40 minutes. The particle size of used nano silver and platinum was 10 ~ 20 nm respectively. Using the polymer produced through the copolymerization process, the authors have produced a contact lens and measured the physical characteristics which showed water content of 34.29 ~ 39.00%, refractive index of 1.422 ~ 1.430, visible transmittance of 78.8 ~ 92.5% and tensile strength of 0.149 ~ 0.179 kgf. The ophthalmic lens material produced using silver/platinum nanoparticles satisfied the basic physical properties required for contact lens application.

Focal Reducer for McDonald Otto Struve Telescope

  • Lim, Ju-Hee;Kim, Young-Ju;Park, Won-Kee;Kim, Jin-Young;Chang, Seung-Hyuk;Pak, Soo-Jong;Im, Myung-Shin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.36.2-36.2
    • /
    • 2010
  • The CQUEAN (Camera for QUasars in EArly uNiverse) is an optical CCD camera optimized for observation of high redshift objects. It is going to be attached to the cassegrain focus of 2.1m telescope at McDonald Observatory, USA. We are making a focal reducer for CQUEAN to secure a larger field of view. The focal reducer is composed of four spherical lens, and it reduces the focal length of telescope by one third. We designed the lens configuration, performed tolerance analysis, and estimated the optical performance with ZEMAX. The differences in optical performace with/without filters were also investigated. The result from ZEMAX shows that the system has ample margin of errors for median seeing of 1.2" at McDonald observatory. Even with aberration and alignment tolerance, the performance is better than the original requirement. The lenses are now being made, and the lens barrel and an adapter for assembly of the Andor CCD camera and the filter wheel is now under designing process. We expect that the manufacturing of the focal reducer system as well as its optical test will be finished by April 2010.

  • PDF

Experimental Analysis of Axial Vibration in Slim-type Optical Disc Drive (슬림형 광 디스크 드라이브의 축방향 진동에 대한 실험적 해석)

  • 박대경;전규찬;이성진;장동섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.694-699
    • /
    • 2002
  • As the demand for slim laptops requires ion'-height optical disc drives, vibration problems of optical disc drives are of great concern. Additionally, with the decrease of a track width and a depth of focus in high density drives, studies on vibration resonance between mechanical parts become more important. From the vibration point of view, the performance of optical disc drives is closely related with the relative displacement between a disc and an objective lens which is controlled by servo mechanism. In other words, to read and write data properly, the relative displacement between an optical disc and an objective lens should be within a certain limit. The relative displacement is dependent on not only an anti-vibration mechanism design but also servo control capability. Good servo controls can make compensation for poor mechanisms, and vice versa. In a usual development process, robustness of the anti-vibration mechanism is always verified with the servo control of an objective lens. Engineers partially modify servo gain margin in case of a data reading error. This modification cannot correct the data reading error occasionally and the mechanism should be redesigned more robustly. Therefore it is necessary to verify a mechanism with respect to the possible servo gain plot. In this study we propose the experimental verification method far anti-vibration mechanism with respect to the existing servo gain plot. This method verifies axial vibration characteristics of optical disc drives on the basis of transmissibility. Using this method, we verified our mechanism and modified the mechanism for better anti-vibration characteristics.

  • PDF

Capturing Admission Judgment Policy from the Lens Model Perspective to Understand the Gender Difference in Science and Engineering (렌즈모델을 이용한 의사결정자의 Admission Policy 분석 - 과학과 공학분야에서의성차이의 영향을 중심으로)

  • Seong, Youn-Ho;Springs, Sherry L.;Tinnin, Deanna;Watkins, Meisha
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.81-90
    • /
    • 2006
  • Despite the government promoting women's participation in the engineering field, some statistics show that it has yet to be achieved. Potential reasons for this phenomenon include lower level of applications by women, or inherent gender gap in the professional field. Therefore, this study attempted to find impact of gender on college admission from the Lens Model perspective and Signal Detection Theory. This study consisted of three phases: identifying the necessary cues used in the admission process, analyzing existing data, and conducting two experiments to identify the effect of gender on admission decisions. Although the college application consisted of many cues, only five cues, school ranking, GPA, SAT score, resident status, and gender, were used to capture the officers' judgment policies for engineering admissions. Two experiments were conducted to investigate the impact of the gender factor in college admission. The enrollment officers first were presented with the existing data without the gender and asked to make dichotomous judgments. Secondly, the officers were asked to perform the judgment task with the gender cue present. Results showed that the gender did not play an important role in the judgments as expected. However, ideographical analyses on judgment strategies revealed that there were significant differences between the admission officers. Possible training implications are discussed.

Study on the Synthesis and Physical Properties of Ophthalmic Polymer Containing Gold Nanoparticles (금 나노입자를 포함한 안의료용 고분자의 합성 및 물성에 관한 연구)

  • Ye, Ki-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.2
    • /
    • pp.222-227
    • /
    • 2010
  • This study added Au colloid in martial of conventional contact lens in various concentrations and copolymerized by heating at $70^{\circ}C$ for 40 minutes, $80^{\circ}C$ for 40 minutes, and finally, $100^{\circ}C$ for 40 minutes. Using the polymer produced through the copolymerization process, we have produced a contact lens and measured the physical characteristics which showed oxygen transmissibility of $9{\sim}12{\times}10^{-9}$ cm/s mL $O_2$/mL ${\times}$ mmHg, water content of 27.84% ~ 32.17%, refractive index of 1.432 ~ 1.443, visible transmittance of 83.2% ~ 89.5% and tensile strength of 0.141 kgf ~ 0.152 kgf. The polymer satisfied the physical properties required to produce contact lenses. Also, we judged that the polymer is suitable to be applied as a functional material for ophthalmological purposes.

Experimental Analysis of Axial Vibration in Slim-type Optical Disc Drive (슬림형 광 디스크 드라이브의 축방향 진동에 대한 실험적 해석)

  • 박대경;전규찬;이성진;장동섭
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.11
    • /
    • pp.833-839
    • /
    • 2002
  • As the demand for slim laptops requires low-height optical disc drives, vibration problems of optical disc drives are of great concern. Additionally, with the decrease of a track width and a depth of focus in high density drives, studies on vibration resonance between mechanical parts become more important. From the vibration point of view, the performance of optical disc drives is closely related with the relative displacement between a disc and an objective lens which is controlled by servo mechanism. In other words, to read and write data properly, the relative displacement between an optical disc and an objective lens should be within a certain limit. The relative displacement is dependent on not only an anti-vibration mechanism design but also servo control capability. Good servo controls can make compensation for poor mechanisms, and vice versa. In a usual development process, robustness of the anti-vibration mechanism is always verified with the servo control of an objective lens. Engineers partially modify servo gain margin in case of a data reading error. This modification cannot correct the data reading error occasionally and the mechanism should be redesigned more robustly. Therefore it is necessary to verify a mechanism with respect to the possible servo gain plot. In this study we propose the experimental verification method for anti-vibration mechanism with respect to the existing servo gain plot. Thismethod verifies axial vibration characteristics of optical disc drives on the basis of transmissibility. Using this method, we verified our mechanism and modified the mechanism for better anti-vibration characteristics.

A case of cataract surgery using phacoemulsification in a 12-year-old poodle

  • Kang, Myeong-Gon;Han, Dong-Hyun;Han, Sei-Myoung;Jung, Eun-Gyeom;Kim, Gyeong-Min;Cho, Jae-Hyeon;Koh, Phil-Ok;Won, Chung-Kil;Kim, Chung-Hui;Lee, Dongbin
    • Korean Journal of Veterinary Service
    • /
    • v.45 no.3
    • /
    • pp.221-228
    • /
    • 2022
  • Cataracts occur commonly in older dogs, which can lead to partial or complete vision loss. In the present study, a 12-year-old male poodle presented for evaluation of ocular sinister (OS) cataract. This study was a clinical case report on the process of performing surgery using phacoemulsification (PHACO) and the problems that arise in patient diagnosed with OS cataract. In the oculus dexter (OD), the artificial eye was inserted because there was no electroretinography (ERG) response. In the OS, the ERG was 51.6 μV, so operation was performed because the visual pathway function remained. Slit-lamp biomicroscopy of the OS showed complete loss of vision as a hypermature cataract and that the lens was hardened. During the cataract surgery using PHACO, visco-elastic agents were used to maintain the shape of the eyeball, and the PHACO procedure took 3.13 minutes. The hardened lens and visco-elastic agents were removed from the eye through PHACO surgery, and the operation was completed by inserting an intraocular lens (IOL). As a result of managing IOP for 2 months after surgery, it remained stable at a maximum of 19 mmHg, and no postoperative ocular hypertension (POH) occurred. Currently, one year has passed since the operation, and the dog maintains its daily life with its left eye without any problems.

A Study on a Visual Sensor System for Weld Seam Tracking in Robotic GMA Welding (GMA 용접로봇용 용접선 시각 추적 시스템에 관한 연구)

  • 김동호;김재웅
    • Journal of Welding and Joining
    • /
    • v.19 no.2
    • /
    • pp.208-214
    • /
    • 2001
  • In this study, we constructed a visual sensor system for weld seam tracking in real time in GMA welding. A sensor part consists of a CCD camera, a band-pass filter, a diode laser system with a cylindrical lens, and a vision board for inter frame process. We used a commercialized robot system which includes a GMA welding machine. To extract the weld seam we used a inter frame process in vision board from that we could remove the noise due to the spatters and fume in the image. Since the image was very reasonable by using the inter frame p개cess, we could use the simplest way to extract the weld seam from the image, such as first differential and central difference method. Also we used a moving average method to the successive position data or weld seam for reducing the data fluctuation. In experiment the developed robot system with visual sensor could be able to track a most popular weld seam. such as a fillet-joint, a V-groove, and a lap-joint of which weld seam include planar and height directional variation.

  • PDF