Browse > Article
http://dx.doi.org/10.5012/jkcs.2010.54.3.310

Physical Properties Variation of Ophthalmic Material in Content of Silver and Platinum Nanoparticle  

Ye, Ki-Hun (Department of Ophthalmic Optics, Daebul University)
Sung, A-Young (Department of Ophthalmic Optics, Daebul University)
Publication Information
Abstract
Nanoparticle with antimicrobial property has been applied to various fields. This study added silver/platinum nanoparticles to HEMA (2-hydroxyethylmethacrylate), NVP (N-vinyl pyrrolidone) and MMA (methylmethacrylate) in various concentrations and copolymerized by heating at $70^{\circ}C$ for 40 minutes, $80^{\circ}C$ for 40 minutes, and finally, $100^{\circ}C$ for 40 minutes. The particle size of used nano silver and platinum was 10 ~ 20 nm respectively. Using the polymer produced through the copolymerization process, the authors have produced a contact lens and measured the physical characteristics which showed water content of 34.29 ~ 39.00%, refractive index of 1.422 ~ 1.430, visible transmittance of 78.8 ~ 92.5% and tensile strength of 0.149 ~ 0.179 kgf. The ophthalmic lens material produced using silver/platinum nanoparticles satisfied the basic physical properties required for contact lens application.
Keywords
Silver nanoparticle; Platinum nanoparticle; Water content;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
Times Cited By SCOPUS : 1
연도 인용수 순위
1 Hill, R. M.; Fatt, I. Science 1963, 142(3597), 1295- 1297.   DOI
2 Kim, T. H.; Ye, K. H.; Sung, A. Y. Journal of the Korean chemical society 2009, 53(3), 391-394.   DOI
3 Park, J. S.; Park, K. B.; Kim, S. D.; Park, H. D. J. of the Korean Sensors Society 2009, 18(5), 327.
4 Wu, H. T.; Lee, M. J.; Lin, H. M. J. of Supercritical Fluids 2005, 33, 173.   DOI
5 Allen, H. F. Ann. ophthalmol. 1971, 3(3), 235.
6 Feng, Q. L.; Wu, J.; Chen, G. Q.; Cui, F. Z.; Kim, J. O. J. Biomed Mater Res. 2000, 54(4), 662.
7 Cecil, W. C.; Charles, M. P.; Paul, W. K. J. AWWA. 1962, 54, 208.   DOI
8 Ye, K. H.; Kim, T. H.; Sung, A. Y. Kor. J. Vis. Sci. 2009, 11(4), 307.
9 Lansdown, A. B. Curr. Probl. Dermatol. 2006, 33, 17.   DOI
10 Kim, T. N.; Feng, Q. L.; Kim, J. O.; Wu, J.; Wang, H.; Chen, G. C.; Cui, F. Z. J. Mater. sci. Mater. Med. 1998, 9, 129.   DOI
11 Lim, S. K.; Lee, S. K.; Hwang, S. H.; Kim, H. Y. Macromol. Mater. Eng. 2006, 291, 1265.   DOI
12 Li, X. J.; Wang, J.; Shenm, L. R.; Xum, Z. J.; Li, P,; Wan, G. J.; Huang, N. Surf. Coat. Technol. 2007, 201, 8155.   DOI
13 Rai, M.; Yadav, A.; Gade, A. Biotechnol. Adv. 2009, 27, 76.   DOI
14 Ye, K. H.; Cho, S. H.; Sung, A. Y. J. Kor. Chem. Soc. 2009, 53(5), 542.   DOI
15 Kim, J. H.; Lee, W. H. The Korean society for geosystem engineering 1996, 33, 358.
16 Lee, H. Y.; Chon, H. T. Sager, M. The Korean society for geosystem engineering 2006, 43(1), 84.
17 Papas, E. B.; Vajdic, C. M.; Austen, R.; Holden, B. A. Current Eye Research 1997, 16(9), 942-948.   DOI
18 Compan, V.; Andrio, A.; Lopez-Alemany, A.; Riande, E.; Refojo, M. F. Biomaterials 2002, 23(13), 2767-2772.   DOI
19 Holden, B. A.; Mertz, G. W. Investigative Ophthalmology & Visual Science 1984, 25, 1161-1167.