• Title/Summary/Keyword: length measuring

Search Result 1,159, Processing Time 0.021 seconds

Development of Trawl Monitoring System ( 1 ) - Distance Measuring System between Trawl Doors - (트롤 모니터링 시스템의 개발에 관한 연구 ( 1 ) - 트롤 전개판의 전개 간격 계측 시스템 -)

  • Shin, Hyeon-Ok;Lee, Chun-Woo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.3
    • /
    • pp.189-193
    • /
    • 1997
  • We make an ultrasonic system as a trial to measure the distance between trawl doors, and carried out a water tank ($24{\times} 24$m, water depth 1 m) experiment for confirming the practical use of the system in October 1996. This system calculates the distance between the pinger (50 kHz) and the transponder (50 kHz/70 kHz) attached each one on the trawl door by measuring the time-difference of receiving with two channels receiver on the trawler. This paper assums that both the length of the warp from the stern to the trawl door is same. At results the system shows a good relation between the distance and the time-difference of receiving while the location of the pinger is moved in variously in the water tank, and it was found that the method of measuring techniques on the prototype system could be applied to the measurement of the trawl door opening in the field experiment.

  • PDF

A Study on Control Method of Thermal Storage Tank for Varying Thermal Load in Heat Pump Water Heater (열펌프 온수기의 부하 대응 축열조 제어에 관한 연구)

  • Nam, Hyun-Kyu;Bai, Cheol-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.330-335
    • /
    • 2012
  • A characteristic behavior of the thermal storage tank for varying thermal load in heat pump water heater was studied. The control method was suggested and applied. By measuring the temperature within the storage tank, the heat pump was ON/OFF controlled. The appropriate measuring position and the size of heat exchanger gives the minimized power consumption of heat pump. As the length of heat exchanger increases, the temperature measuring position goes down of the storage tank and the power consumption increases.

The Moving Function for Slacks Related to Thigh Circumference and Crotch Length (슬랙스 대퇴부 둘레와 허리선 위치에 따른 동작기능성)

  • Yun, Jee-Yun;Kweon, Soo-Ae
    • Korean Journal of Human Ecology
    • /
    • v.8 no.3
    • /
    • pp.551-563
    • /
    • 1999
  • In this study, university students were allowed to wear the slacks varying the thigh circumference(slim/straight type) and crotch length(long, middle, short crotch type). Tightness and uncomfortability for each slacks were measured to be expressed 5point-likert type. The results can be summarized as follows: 1. At the research for measuring uncomfortability, measures of slim types and straight types of thigh circumference, crotch length B and C, and the body movement such as sitting down on the chair, sitting down with their body curling like a ball, and getting down on their knees were higher in slim types than in straight types. 2. Only crotch length C had different measures between these two types in tightness. 3. In uncomfortability, each of them had different measures among three kinds of crotch length and two types of thigh circumference had different measures among three kinds of crotch length. Four kinds of movement had different measures among three kinds of crotch length in uncomfortability. While uncomfortability of crotch length B was the highest one, that of crotch length A was the lowest one. 4. In tightness, each of them had different measures among three kinds of crotch length. While tightness of crotch length C was the highest one, that of crotch length A was the lowest one. Four kinds of movement had different measures among three kinds of crotch length in tightness.

  • PDF

A Study on the Pattern of Hanbok Jegory for Bending Somatotyped Women in Old Age (노년여성(老年女性) 숙인체형(體型)의 저고리 원형(原型)에 관(關)한 연구(硏究))

  • Nam, Youn-Ja;Han, Seung-Hee
    • Journal of Fashion Business
    • /
    • v.8 no.4
    • /
    • pp.22-32
    • /
    • 2004
  • The purpose of this research is to know the pattern of Hanbok Jegory with measuring Jegory and studying manufacturing method of the Jegory used currently. It is a purpose to find constitutional problem caused by the character of the bending somatotype and, to study the standard model of the Jegory for bending somatotyped women in old age, by comparison of this fitness for bending-somatotyped women in old age. The results obtained are as follows; 1. The kinds of measurements considered in manufacturing process are Hwajang Length, Bust girth, and the skirt length. The length of Jegory and width of Neck are also considered. 2. Manufacturers consider somatotype the most important thing when they make Jegory for women in old age. Front length, Back length and Width of the Jegory are considered secondly important. 3. The results of the comparison show that the Standard Hanbok drafting method is not suitable for drafting Jegory for bending somatotyped women in old age. 4. The suitability test for the model designed by the above methods shows that it fits in bending somatotyped women in old age better than standard drafting method. The results show the superiority of the above methods especially in the breast width, the Godae length, and the adaptedness to the body.

The Relationship Between Hip Adduction Angle of Ober Test According to Tibial Rotation and Length of the Iliotibial Band (정강뼈 돌림에 따른 오버테스트의 엉덩관절 모음 각도와 엉덩정강뼈 환 길이의 상관관계)

  • Park, Joo-Hee;Lee, Sa-Gyeom
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.1
    • /
    • pp.43-49
    • /
    • 2017
  • PURPOSE: This study investigated the relationship among hip adduction angle, tibial rotation, and ITB length during an Ober test to determine the most appropriate position for performing the test. METHODS: The study included thirty-nine asymptomatic participants (23 males, 16 females). Their hip adduction angles were measured using the Ober test during three tibial rotation conditions (internal tibial rotation, external rotation, and neutral position). ITB length was calculated by measuring the position of the patella to lateral femoral condyle using ultrasonography (patella-condyle distance; PCD). RESULTS: The relationship among hip adduction angle, tibial rotation, and ITB length was analyzed under the three conditions using the Pearson correlation. The hip adduction angle of the internal tibial rotation, the external rotation, and the neutral position were significantly related to ITB length. Moreover, the hip adduction angle measured during the internal tibial rotation had the highest correlation with ITB length among the three conditions (r=.58, p<.001). CONCLUSION: Internal tibial rotation caused by the Ober test led to increased iliotibial band (ITB) tension and a decreased adduction angle. These findings support that tibial rotation influences the flexibility of ITB. Therefore, therapists should consider the position of the internal tibial rotation when taking measurements using an Ober test.

Wide-Width Tensile Strength Properties of Geogrids according to Specimen Length and Testing Speed (시료크기 및 인장속도에 따른 지오그리드의 광폭인장강도 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Oh, Se-Yong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.2
    • /
    • pp.21-26
    • /
    • 2007
  • The tensile properties of geogrid are affected by such factors as temperature, specimen length, gauge length, testing speed and measuring equipment. The tensile strength of geogrids can be determined by ASTM 06637 and ISO 10319. The main differences between two testing methods are testing speed and specimen length. This paper presents the results of the wide-width tensile tests for three geogrids according to different specimen length and tension speed.

  • PDF

A Survey on the Second and the Third Graders' Reasoning Ability of Length (초등학교 2, 3학년 학생들의 길이 추론 능력 실태 조사)

  • Pang, Jeong-Suk;Ji, Hye-Eun
    • Journal of Educational Research in Mathematics
    • /
    • v.19 no.2
    • /
    • pp.321-340
    • /
    • 2009
  • The purpose of this study was to analyze how lower graders in elementary school might respond to 4 different problem types in the context of measuring length: unit-length comparison, units and unit counting, unit-length expectation, and length comparison. A total of 375 students(185 second graders and 190 third graders) were surveyed and analyzed. The results showed that students were good at 'unit-length comparison' and 'units and unit counting', whereas they were not as to 'length comparison', This paper includes detailed analysis of students' responses as to both correct answer and incorrect one in conjunction with their typical answers and reasoning behind the answers. This paper suggests that teachers be sensitive to the certain level of reasoning tied to each type of problems and attend to students' difficulties in comparing length.

  • PDF

A COMPARISON OF THE LENGTH BETWEEN MESIO-BUCCAL AND MESIO-LINGUAL CANALS OF THE MANDIBULAR MOLAR (하악대구치 근심치근의 협설측 근관장의 비교)

  • Park Seul-Hee;Noh Bong-Hwan;Hwang Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.541-547
    • /
    • 2004
  • The aim of this study was to compare the initial apical file (IAF) length between the mesio-buccanl and mesio-lingual canals of the mandibular molar before and after early coronal flaring. Fifty mandibular molars with complete apical formation and patent foramens were selected. After establishing the initial working length of the buccal and lingual canal of the mesial root using the Root-ZX, radiographs were taken for the working length with a 0.5 mm short of #15 K-file tip just visible at the foramen under a surgical microscope (OPMI 1-FC, Carl Zeiss Co. Germany) at 25X. After early coronal flaring using the $K^3$ file, additional radiographs were taken using the same procedure. The root canal morphology and the difference in working length between the buccal and lingual canals were evaluated. These results show that the difference in the length between the mesio-buccal and mesio-lingual canals of the mandibular molar was $\leq$ 0.5 mm. If one canal has a correct working length for the mesial root of the mandibular molar, it can be used effectively for measuring the working length of another canal when the files are superimposed or loosening. In addition, the measured the working length after early coronal flaring is much more reasonable because the difference in the length between the mesio-buccal and mesio-lingual canals can be reduced.