• Title/Summary/Keyword: length measurement

Search Result 2,195, Processing Time 0.028 seconds

Effective Volume of the Korea Research Institute of Standards and Science Free Air Chamber L1 for Low-Energy X-Ray Measurement

  • Chul-Young Yi;Yun Ho Kim;Don Yeong Jeong
    • Progress in Medical Physics
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose: To evaluate the effective volume of the Korea Research Institute of Standards and Science free air chamber (KRISS FAC) L1 used for the primary standard device of the low-energy X-ray air kerma. Methods: The mechanical dimensions were measured using a 3-dimensional coordinate measuring machine (3-d CMM, Model UMM 500, Carl Zeiss). The diameter of the diaphragm was measured by a ring gauge calibrator (Model KRISS-DM1, KRISS). The elongation of the collector length due to electric field distortion was determined from the capacitance measurement of the KRISS FAC considering the result of the finite element method (FEM) analysis using the code QuickField v6.4. Results: The measured length of the collector was 15.8003±0.0014 mm with a 68% confidence level (k=1). The aperture diameter of the diaphragm was 10.0021±0.0002 mm (k=1). The mechanical measurement volume of the KRISS FAC L1 was 1.2415±0.0006 cm3 (k=1). The elongated length of the collector due to the electric field distortion was 0.170±0.021 mm. Considering the elongated length, the effective measurement volume of the KRISS FAC L1 was 1.2548±0.0019 cm3(k=1). Conclusions: The effective volume of the KRISS FAC L1 was determined from the mechanically measured value by adding the elongated volume due to the electric field distortion in the FAC. The effective volume will replace the existing mechanically determined volume in establishing and maintaining the primary standard of the low-energy X-ray.

Estimation on The Atmospheric Stability and Flow Characteristics of Planetary Boundary Layer in Wolryong Coastal Region (월령 연안지역 대기경계층의 유동특성과 대기 안정성에 대한 고찰)

  • Jeong, Tae-Yoon;Lim, Hee-Chang;Kim, Hyun-Goo;Jang, Moon-Seok
    • Journal of Environmental Science International
    • /
    • v.18 no.8
    • /
    • pp.857-865
    • /
    • 2009
  • The physical properties of an atmospheric boundary layer in Wolryong, a west coastal region of Jeju, South Korea, in terms of the atmospheric stability and roughness length, is important and relevant to both engineers and scientists. The study is aiming to understand the atmospheric stability around this region and its effect on the roughness length. We calculate the Monin-Obukhov length(L) against 3 typical regions of the atmospheric condition - unstable regime (-5$-0.2{\leq}H/L{\leq}0.2$) and stable regime (0.2

A Study on Breast Type Classification & Discrimination Using Manual Measurement- Focusing on Korean Women in Their 20s -

  • Sohn, Boo-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.5
    • /
    • pp.137-146
    • /
    • 2020
  • The manual measurements of 182 unmarried women subjects in their 20s was classified 4-breast types. For the breast type classification, 4 factors were identified, such as overall breast factor, upper breast internal shape factor, breast volume factor, and lower breast external shape factor. The breast shapes were 'breast with well-grown upper part', 'flat breast', 'breast with well-grown lower part', and 'protruded breast'. The breast types can be differentiated in 10 items of actual anthropometric dimension the length between frontal neck point and nipple point, length between lateral neck point and nipple point, length between the breast inner points, nipple to nipple breadth, diameter below the breast, inner depth of breast, outer length of breast, length below the breast, length between breast outer point and upper breast point, and contour line length below the breast.

The Analysis on Relation between Hamstring Length and Static Uprighting Balance (넙다리 뒤근육의 길이와 정적 기립균형과의 상관성 분석)

  • Nam, Kun-Woo
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate hamstring length during static uprighting position using weight distribution ratio. Methods: Ninety-six volunteers(56 males) were participated. The active knee extension test(AKE) was measured 3 times on both legs. The mean score of AKE was obtained. Then, the measurement of weight distribution ratio was observed 3 times on both legs, and its mean value was also calculated. Subjects were divided four groups based on their hamstring length measurement; both hamstring shortening group, left hamstring shortening group, right hamstring shortening group and normal hamstring length group. One-way ANOVA was employed to analyse collected data. Pearson's correlation was also hired to see any relationship between the hamstring length and the weight distribution. Results: In anterior/left area and posterior/right area, both hamstring shortening group left hamstring shortening group were superior to right hamstring shortening group and normal hamstring length group. Significant difference was existed statistically(p<.05) between groups. The correlation analysis between hamstring length and weight distribution ratio has not been shown any significant findings(Pant/post=0.733, Plt/rt=0.135). Conclusion: The results of the study may be applied to therapeutic management in posture and movement skill in musculoskeletal physical therapy.

  • PDF

A Study on Measurement of Length and Slope of Temporary Structure using UAV (무인항공기를 활용한 가설구조물의 길이와 기울기 측정에 관한 연구)

  • Min-Guk, Kang;Seung-Hyeon, Shin;JongKeun, Park;Jeong-Hun, Won
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.89-95
    • /
    • 2022
  • A method for measuring the length and slope of a temporary structure using an unmanned aerial vehicle (UAV) and 3D modeling method is proposed. The actual length and slope of the vertical member of the specimen were measured and compared with the measured values obtained by the proposed method for the specimens with and without the vertical protection net installed. Based on the result of measuring the length of the temporary structure specimen using the UAV and 3D modeling method, the measured value showed an error of 0.87% when compared to the actual length in the specimen without the vertical protection net installed. In addition, the error of the slope was 0.63°. It was thought that the proposed method could be usable for the purpose of finding parts in wrong installation state on the temporary structure and informing the manager in charge. However, in the case of the specimen with the vertical protection net, the measurement showed a 1.46% error in length and 2.77° difference in slope. Therefore, if a vertical protection net is to be installed in a temporary structure, the measurement accuracy should be improved by utilizing an image processing method, etc.

Nerve length measurement method in a radial motor nerve conduction study

  • Kim, Jae-Gyum;Kim, Yoohwan;Seok, Hung Youl;Kim, Byung-Jo
    • Annals of Clinical Neurophysiology
    • /
    • v.19 no.1
    • /
    • pp.28-33
    • /
    • 2017
  • Background: Previous studies of radial nerve conduction study (NCS) did not present how to measure the length of the radial nerve across the elbow, and did not even mention how to manage the spiral course of the nerve. This study aimed to applicate the most reliable method to measure the length of the radial nerve during NCS. Methods: Three points (A, B, and C) were determined along the relatively straight course of the radial nerve. The distance was measured using three different methods: L1) straight distance corresponding to the A-C distance, L2) sum of the distances corresponding to the A-B-C distance, L3) based on the L2, but the elbow is flexed at a $45^{\circ}$ angle. We compared the three methods of distance measurement and the calculated nerve conduction velocities (V1, V2, and V3) in normal healthy subjects. Results: 19 normal participants were enrolled. The mean value for method L1, L2 and L3 were $22.5{\pm}1.8cm$, $24.0{\pm}2.1cm$, and $23.2{\pm}2.1cm$ (p < 0.001). Calculated conduction velocities using those distance measurement methods as follows (p < 0.001): V1 ($60.9{\pm}2.7m/s$), V2 ($64.6{\pm}3.3m/s$), and V3 ($63.4{\pm}3.9m/s$). V2 was significantly greater than V1 and V3 (p < 0.001, p = 0.010, respectively). Conclusions: The distance measurement using a stopover point near the lateral epicondyle between two stimulus points in position of a fully extended elbow with forearm pronation is the most appropriate posture for radial motor NCS.

The Database Development of 2-D Hands Measurement for Improving Fitness of gloves -focused on the ages from 18 to 64 of male & female adults- (장갑의 적합성 향상을 위한 손부위 2차원 계측정보 DB구축에 관한 연구 -성인 남.녀 만 18세에서 만 64세를 중심으로-)

  • 최혜선;김은경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.3_4
    • /
    • pp.509-520
    • /
    • 2004
  • The aim of this study was to provide the basic 2-dimensional statistics requisite in the siting system and design of gloves. The 64 static measurements were selected to provide information about hands. Participants in the study were 824 adults, aged between 18 and 64. Subjects were divided into four age groups: 18 to 29, 30 to 39, 40 to 49, and 50 to 64, and separated according to sex. Statistical tests such as Descriptive Analysis, and Anova were conducted to analyze the data and ascertain the differences among the ages. The disparities between sex groups were compared by T-test. In addition, correlation among the 57 measurements was analyzed and the results were compared to the data from Japanese and other studies. The results indicated that all the measurements were significantly larger in the male group. There were significant differences among age groups for most hand circumferences, breadths and thickness items. As the age increased, the hand circumferences, breadths and thickness items became wider and thicker. In addition, as the age increased, the mean measurement value of the length items decreased, so that it became shorter. Hand length was highly correlated with finger length, palm length and height. Maximum hand circumference II was highly correlated with hand circumferences, hand breadth and weight.

An Analysis of Craniofacial Shape for Male Adults by 3D Measurement (3차원 측정에 의한 한국 성인남자의 머리형태 분석)

  • Kim Hyesoo;Yi Kyong-Hwa;Park Se-Jin
    • Journal of the Korean Society of Costume
    • /
    • v.55 no.3 s.93
    • /
    • pp.69-80
    • /
    • 2005
  • The anatomical structure of the head and face are influenced by environmental factors. Therefore in this study we had undertaken to determine normal values of the head and face by 3D measurement in the 384 normal Korean male adults to find out craniofacial characteristics of Korean male adults by the age group. From the basic statistical data analysis, vertex-tragion and the length between the pupils were the longest in their twenties and grew shorter in elderly groups. According to the analysis of the craniofacial proportion, the head type of Korean male adults was short-headed. The statistically noticeable differences were found in the measurement of the left and the right sides of face in the age groups of 20, 30, 40, and 50. The results of the factor analysis of the age group showed two groups which were classified to 20, 40, 50 ages and 30, 60 ages. The order of factor analysis was as follows; the perpendicular length, the horizontal length, and the width (from highest).

Representative Male Upper Body types of the 20s by the Combination of Direct and Indirect Measurement Values (직접측정치(直接測定値)와 간접측정치(間接測定値)의 결합(調合)에 의한 20대(代) 남성(男性) 상방신(上半身) 대표체형(代表體型) 연구( 硏究))

  • Li, Eun-Ji;Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.11 no.4
    • /
    • pp.135-151
    • /
    • 2007
  • This study is human body measurement of 200 adult males in their 20s by both direct and indirect methods in order to reveal the representative male upper body types. Composition factors of body types were classified while the combination of direct-indirect measurement values was chosen. The following are the findings: 1) The analysis of direct-indirect measurement statistics showed the following results: 173.80cm (height), 69.87kg (weight), 95.58cm (chest girth), $24.67^{\circ}$ (right shoulder angle), and $9.34^{\circ}$ (shoulder width angle). 2) The factor analysis of the body types by direct measurement produced 5 factors: 1 (front length of upper body), 2 (front length of upper body), 3 (back length of upper body), 4 (circumference of upper body), and 5 (shoulders length). These factors accounted for 90.08%. Also, the cluster analysis of factor scores led to 3 types: 1 (33%, short, comparatively wide shoulders and full in the hips), 2 (25.1%, well-developed upper body in tall, inversed triangle), 3 (41%, average height, short upper body). 3) The body-type factor analysis by indirect measurement resulted in 6 factors with the explanation of 83.24%: 1 (rear upper bady thickness), 2 (front upper body width), 3 (front chest thickness), 4 (left-right shoulder angle), 5 (front width of protrusion distance in chest and shoulders), and 6 (neck's front-rear side angle).In addition, the cluster analysis of factor scores brought about 4 types: 1 (15%, well-developed front chest, beardless waist), 2 (23.5%, flat chest, with shoulder, drooping shoulders, strait neck), 3 (39%, with shoulder, curved back), and 4 (22.5%, narrow and thin, curved waist). 4) Among the 118 subjects (75%), 58 subjects commonly appearing in indirect measurement values group and direct measurement values group were chosen the representative body type group according to asterisk indexes. They had the highest frequency in direct type 3 and indirect type 3, whose combination represented the physical characteristics of the representative body types.

A Study on Sampling Techniques to Assure the Representativeness of Short-term Equivalent Noise Level (단기간 소음도의 대표성 확보를 위한 소음도 추출기법 연구)

  • Ryu, Hun Jae;Ko, Joon Hee;Chang, Seo Il;Lee, Byung Chan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.12
    • /
    • pp.1213-1219
    • /
    • 2012
  • The purpose of this study is to present a guideline to design a short-term manual measurement of environmental noise level, which is more economical and flexible, but less representative than long-term automatic measurement. The proposed guideline can provide the number of measurement times and the length of measurement term required to secure the extent of the representativeness. The data was collected at 4 sites located in Seoul and at 4 sites located outside of Seoul. The probabilities for five-minute equivalent noise levels, Leq, 5min, to stay in an error range from the quarterly representative noise level were used to evaluate sampling techniques. The probability analysis of the daytime period showed that the noise levels measured between 10 am and 2 pm and between 9 pm and 10 pm have the probabilities higher than 60 %. On the other hand, even for the same length of total measurement time, increasing the number of random samplings results in higher probabilities than increasing the length of measurement term.