• Title/Summary/Keyword: length measurement

Search Result 2,201, Processing Time 0.024 seconds

Evaluating the Accuracy of an OpenCV-Based Length Measurement Algorithm: The Impact of Checkerboard Type and Capturing Conditions (체커보드 종류 및 촬영조건에 따른 OpenCV 기반 길이측정 알고리즘 정확도 분석)

  • Kim, Hyeonmin;Kwon, Woobin;Kim, Harim;Kim, Hyungjun;Song, Seung Ho;Cho, Hunhee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.1
    • /
    • pp.133-144
    • /
    • 2024
  • The OpenCV-based length measurement algorithm is anticipated to be effective for length measurement inspection tasks, providing objective inspection outcomes. Nonetheless, there is a notable gap in research regarding the influence of various checkerboard types and capturing conditions on the algorithm's accuracy in real-world construction settings. Consequently, this study proposes a methodology employing an OpenCV-based length measurement algorithm and checkerboard for digital construction inspection tasks. The findings suggest that using a checkerboard with square sizes of A4 or larger, and 50mm or larger, is optimal for capturing distances and angles within 4m and 90°, respectively, when deploying the algorithm. These insights are anticipated to provide practical guidelines for professionals conducting digital-based length measurement inspections.

Quantity Measurement by CAFFE Model and Distance and Width Measurement by Stereo Vision (CAFFE 모델을 이용한 수량 측정 및 스테레오 비전을 이용한 거리 및 너비측정)

  • Kim, Won-Seob;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.4
    • /
    • pp.679-684
    • /
    • 2019
  • We propose a method to measure the number of specific species of class using CAFFE model and a method to measure length and width of object using stereo vision. To obtain the width of an object, the location coordinates of objects appearing on the left and right sensor is compared and the distance from the sensor to the object is obtained. Then the length of the object in the image by using the distance and the approximate value of the actual length of the object is calculated.

A Study on Pobeckchuck in the Former Period of Chosun Dynasty(First) - Focusing on the True Record of Chosun Dynasty - (조선시대 전기의 포백척에 관한 연구(上) - 조선왕조실록을 중심으로 -)

  • 이은경
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.4
    • /
    • pp.87-99
    • /
    • 2003
  • The measurement in ruling period of King Sejong in Chosun Dynasty remained unchanged compared with that of Goyeo Dynasty. But Hwangjongchuck, the basis of measurement was amended in the 7th year in ruling period of King Sejong, Juchuck, Youngchochuck, Cholegichuck in the 12th, and Pobeckchuck in the 13th. The record of Pobeckchuck first appeared in the true record of Chosun Dynasty in the 4th year in ruling period of Sejong, and first record on the amendment of the Pobeckchuck was found in the 13th year in his ruling period. The presentation of the comparison of Pobeckchuck with Cholegichuck in volume 128 of true record of Sejong makes help the estimation of the length of Pobeckchuck. To calculate one Chuck of Pobeckchuck with this measurement comes to 44.75cm in present measurement, and the length at this time had remained unchanged to Yeonsangun period. Important fact which was newly found in the true record of Chosun Dynasty was that Pobeckchuck had been used for diverse purposes. Pobeckchuck was used to measure width, length and thickness in manufacturing wardrobe. and also to measure cloth decorating wardrobe. This is the first record(4th year of reign of Sejong) showing that Pobeckchuck was first used to measure cloth in Chosun Dynasty The record shows that Pobeckchuck was also used to measure the length of circumference of castle for its construction. to measure distances between people, the length of hook of wooden handle, and the height of man.

Comparison of Size between direct-measurement and 3D body scanning (중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구)

  • Cha, Su-Joung
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.150-159
    • /
    • 2012
  • This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below: In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of directmeasurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

Adaptation of Customized Measurement of Stride Length in Smart Device (스마트 기기를 활용한 보행속력에 따른 맞춤보폭의 적용)

  • Lee, Byung Mun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.4
    • /
    • pp.35-43
    • /
    • 2013
  • Exercise such as walking is helpful to manage one's own weight and to counter life habit diseases such as obesity. Calorie consumption is usually calculated based on the distance walked. One way to measure the distance is by using steps and stride length. Most pedometers, including some applications in smart devices, are inaccurate, because they use a common value as the average stride length, even though each person has a different stride length. Moreover, the stride length differs depending on the walking pace, which will further increase the error. To address this, in this paper, I classify paces into three categories. Following that, I introduce a customized measurement of stride length, which is calculated based on the stride length corresponding to each pace category after obtaining x, y, z values from a 3-axis accelerometer in the smart device. In addition to this, I developed an application running on the smart device designed for the proposed measurement of stride. I have conducted three experiments for the assessment of the proposed measurement. In conclusion, I confirmed the effectiveness of this system.

Elementary Math Textbooks and Real Life Comparative Analysis of Representations for Length and Time (초등 수학 교과서와 실생활에서 나타나는 길이와 시간에 대한 표현 비교 분석)

  • Kang, Yunji
    • Education of Primary School Mathematics
    • /
    • v.25 no.3
    • /
    • pp.233-249
    • /
    • 2022
  • Measurement plays an important role in both school mathematics and real life. Among the measurement areas, length is the first to learn and is the basis for measurement. Time is measured in its own way and is characterized by being the most abstract. This study attempted to analyze elementary mathematics textbooks and representations in real life to examine how the length and time of learning in school mathematics differ from those represented in real life. Based on this, we tried to derive implications for the direction of measurement education and elementary math textbooks. As a result of the analysis, the concept of length was used the same in real life and school mathematics. However, terms such as distance, depth, and height were not defined, and the representation of the approximate value was presented in a fragmentary form. In addition, there were parts where students were likely to feel confused in school mathematics and real life, such as the same units such as 'minutes and seconds' were used in time. Therefore, considering these differences, it is necessary to consider the direction of composition of math textbooks and teaching and learning so that students can connect school mathematics and real life and understand widely about measurement concepts.

Development of Line Standards Measurement System Using an Optical Microscope (광학 현미경을 이용한 선표준물 측정 시스템 개발)

  • Kim, Jong-Ahn;Kim, Jae-Wan;Kang, Chu-Shik;Eom, Tae-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.8
    • /
    • pp.72-78
    • /
    • 2009
  • We developed a line standards measurement system using an optical microscope and measured two kinds of line standards. It consists of three main parts: an optical microscope module including a CCD camera, a stage system with a linear encoder, and a measurement program for a microscopic image processing. The magnification of microscope part was calibrated using one-dimensional gratings and the angular motion of stage was measured to estimate the Abbe error. The threshold level in line width measurement was determined by comparing with certified values of a line width reference specimen, and its validity was proved through the measurement of another line width specimen. The expanded uncertainty (k=2) was about 100 nm in the measurements of $1{\mu}m{\sim}10{\mu}m$ line width. In the comparison results of line spacing measurement, two kinds of values were coincide within the expanded uncertainty, which were obtained by the one-dimensional measuring machine in KRISS and the line standards measurement system. The expanded uncertainty (k=2) in the line spacing measurement was estimated as $\sqrt{(0.098{\mu}m)^2+(1.8{\times}10^{-4}{\times}L)^2}$. Therefore, it will be applied effectively to the calibration of line standards, such as line width and line spacing, with the expanded uncertainty of several hundreds nanometer.

Analysis on the Measurement and Shape Classification of the Bead of Korean Male Children for the Headwear Sizing System (초등학교 남자아동의 모자 제작을 위한 머리부위 측정 및 형태 분석)

  • Kim Son Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.5 s.142
    • /
    • pp.737-744
    • /
    • 2005
  • This study was aimed to provide the measurement data and shape classification of the head of the Korean male children for the headwear sizing systems. Five hundred twenty male children, aged nine to twelve years, participated f3r this study. The 17 regions on the head and height, weight of the subjects were directly measured by the expert experimenters. Factor analysis, cluster analysis, GLM analysis and Tukey HSD test were performed using these data. Through factor analysis, low factors were extracted upon factor scores and those factors comprised $69.76\%$ for the total variances. Three clusters as their head shape were categorized using four factor scores by cluster analysis. Type 1 was characterized by the widest width and Bitragion arc, shortest head length. Type 2 had the longest head length and the widest side width and the highest head length and head circumference. Type 3 was characterized by the smallest head circumstance, head width and side width, and medium head length.

A Comparative Study on the Measurement of Korean Adult Hand for Glove Pattern-Making (장갑 설계를 위한 한국인 성인 남녀의 손 계측 비교)

  • Suh Mi-A;Ryu Kyung-Ok
    • The Research Journal of the Costume Culture
    • /
    • v.12 no.6 s.53
    • /
    • pp.897-907
    • /
    • 2004
  • The aim of this study is provide fundamental data on the glove size and pattern-making. The study was conducted targeting 60 men and 271 women whose age were within the limits 18-35 in Seoul and the neighboring districts. A total of 90 features in the right hand wew used for the anthropometric measurement and analysis using anthropometry and photometry. The result show that there was a difference between men and women' hand. And the result of correlation analysis between hand factors, length factor related to length and depth factors, breadth factor related to breadth and circumference factors. The sailing glove size in Korea was not suitable to Index finger circumference at 1st Phalanx and Middle finger length.

  • PDF

Measurement of Crack Length by Ultrasonic Attenuation Coefficient (초음파 감쇠계수에 의한 균열길이의 측정)

  • Chung, Nam-Yong;Park, Sung-Il
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.340-345
    • /
    • 2003
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the relation between crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the results of experiments, the measurement method of crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF