• Title/Summary/Keyword: length measurement

Search Result 2,195, Processing Time 0.029 seconds

Evaluation of Debonding Defects in Railway Concrete Slabs Using Shear Wave Tomography (전단파 토모그래피를 활용한 철도 콘크리트 궤도 슬래브 층분리 결함 평가)

  • Lee, Jin-Wook;Kee, Seong-Hoon;Lee, Kang Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.11-20
    • /
    • 2022
  • The main purpose of this study is to investigate the applicability of the shear wave tomography technology as a non-destructive testing method to evaluate the debonding between the track concrete layer (TCL) and the hydraulically stabilized based course (HSB) of concrete slab tracks for the Korea high-speed railway system. A commercially available multi-channel shear wave measurement device (MIRA) is used to evaluate debonding defects in full-scaled mock-up test specimen that was designed and constructed according to the Rheda 200 system. A part of the mock-up specimen includes two artificial debonding defects with a length and a width of 400mm and thicknesses of 5mm and 10mm, respectively. The tomography images obtained by a MIRA on the surface of the concrete specimens are effective for visualizing the debonding defects in concrete. In this study, a simple image processing method is proposed to suppress the noisy signals reflected from the embedded items (reinforcing steel, precast sleeper, insert, etc.) in TCL, which significantly improves the readability of debonding defects in shear wave tomography images. Results show that debonding maps constructed in this study are effective for visualizing the spatial distribution and the depths of the debondiing defects in the railway concrete slab specimen.

Effect of tension difference of kinesio tape applied to the tibialis anterior muscle on muscle strength, joint range of motion, and balance of the ankle joint in young college students (키네시오 테이프의 장력 차이가 젊은 대학생들의 발목 근력, 관절가동범위 및 균형에 미치는 영향)

  • Lee, Dae Hoon;Kim, Cho In;Shin, Gi Ha;Yeom, Yoo Jin;Kim, Ji Sung;Kim, Seong Ho
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.2
    • /
    • pp.28-37
    • /
    • 2022
  • Background: The purpose of this study was to investigate the effects of differences in the tension of Kinesio tape applied to the tibialis anterior muscle on muscle strength, joint range of motion and balance of ankle joint in young adults. Design: Randomized Controlled Trial. Methods: 41 young college students participated in this study. And the subjects were allocated randomly to two group. The experimental group had a tension difference (10%G, n=20). And there was no difference in tension in the control group (0%G, n=21). Jtech power track II, goniometer, and Biorescue were used to measure muscle strength, joint range of motion and balance. The paired t-test was performed to examine the differences within the groups before and after taping, and the independent t-test was performed to examine the differences between the groups. Result: 1) As a result of measuring muscle strength of each group, all measurements except 0%G of plantar flexion showed insignificant results. 2) Measurement of joint range of motion each group showed that neither 0%G nor 10%G was significant. 3) As a result of measuring the baladncing ability of each group there was a significant decrease in length, and average speed of the balancing capability (p<.05). 4) Comparisons between groups showed significant differences in the area among balance capability (p<.05). Conclusions: Based on these findings, the tension difference of Kinesio tape applied to the tibialis anterior muscle shows little effect on the muscle strength, range of motion, and balance of ankle joints. Given the current lack of research on the tension of kinesio tapes many studies are needed in the future to establish clear theories.

Influence of Hanwoo (Korean Native Cattle) Manure Compost Application in Soil on the Growth of Maize (Zea mays L.) (한우퇴비 시용에 따른 옥수수(Zea mays L.)의 생육에 미치는 영향)

  • Byeon, Ji-Eun;Lee, Jun Kyung;Park, Min-Soo;Jo, Na Yeon;Kim, Soo-Ryang;Hong, Sung-ha;Lee, Byong-O;Lee, Myung-Gyu;Hwang, Sun-Goo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.67 no.3
    • /
    • pp.164-171
    • /
    • 2022
  • We studied the influence of Hanwoo (Korean native cattle) manure compost soil application on the growth and yield of maize (Zea mays L.). We compared the soil application of chemical fertilizer (CF), commercial manure (CM), Hanwoo manure (HM), and the mixed Hanwoo manure and chemical fertilizer (HM + CF). CF application showed faster tasseling and silking dates compared to the other treatments. During the early plant growth stage of maize, CF application resulted in taller plant height, However, during later growth stages (55 days after transplanting). HM (226.0 cm) and HM + CF (230.0 cm) treatment resulted in taller plant height compared to CF (216.2 cm). Post-harvest measurement results showed that, the ear length was longer in HM (22.13 cm) and HM + CF (22.70 cm) compared to others, while ear diameter, ear weight, and 100-grains weight showed no significant difference among CF, HM, and HM + CF groups. The use of HM resulted in delayed growth during the early stages of plant development compared to CF. However, crop productivity markers of ear weight and ear diameter showed no significant difference compared to CF. Thus, HM treatment was comparable to CF treatment in maize cultivation.

Cause of Rockfall at Natural Monument Pohang Daljeon-ri Columnar Joint (천연기념물 포항 달전리 주상절리의 낙석 발생원인)

  • Kim, Jae Hwan;Kong, Dal-Yong
    • Economic and Environmental Geology
    • /
    • v.55 no.5
    • /
    • pp.497-510
    • /
    • 2022
  • Monthly monitoring, 3D scan survey, and electrical resistivity survey were conducted from January 2018 to August 2022 to identify the cause of rockfall occurring in Daljeon-ri Columnar Joint (Natural Monument No. 415), Pohang. A total of 3,231 rocks fell from the columnar joint over the past 5 years, and 1,521 (47%) of the falling rocks were below 20 cm in length, 978 (30.3%) of 20-30 cm, and 732 (22.7%) of rocks over 30 cm. While the number of rockfalls by year has decreased since 2018, the frequency of rockfalls bigger than 30 cm tends to increase. Large-scale rockfalls occurred mainly during the thawing season (March-April) and the rainy season (June-July), and the analysis of the relationship between cumulative rainfall and rockfall occurrence showed that cumulative rainfall for 3 to 4 days is also closely related to the occurrence of rockfall. Smectite and illite, which are expansible clay minerals, were observed in XRD analysis of the slope material (filling minerals) in the columnar joint, and the presence of a fault fracture zone was confirmed in the electrical resistivity survey. In addition, the confirmed fault fracture zone and the maximum erosion point analyzed through 3D precision measurement coincided with the main rockfall occurrence point observed by the BTC-6PXD camera. Therefore, the main cause of rockfall at Daljeon-ri columnar joint in Pohang is a combination of internal factors (development of fault fracture zones and joints, weathering of rocks, presence of expansive clay minerals) and external factors (precipitation, rapid thawing phenomenon), resulting in large-scale rockfall. Meanwhile, it was also confirmed that the Pohang-Gyeongju earthquake, which was continuously raised, was not the main cause.

Assessment of Validity and Reliability of Plantar Pressure in Smart Insole (스마트 인솔의 족저압 측정 결과에 대한 타당도 및 신뢰도 평가)

  • Kang, Ho Won;An, Yae Lynn;Kim, Dae-Yoo;Lee, Dong-Oh;Park, Gil Young;Lee, Dong Yeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.26 no.3
    • /
    • pp.130-135
    • /
    • 2022
  • Purpose: Smart insoles are wearable devices that are inserted into shoes. Smart insoles with built-in pressure and acceleration sensors can measure the plantar pressure, stride length, and walking speed. This study evaluated the validity and reliability of the plantar pressure measurements of smart insoles during walking on flat ground. Materials and Methods: Twenty one subjects were included in this study. After wearing smart insoles, I-SOL® (Gilon, Seongnam, Korea), the subjects walked a 10 m corridor six times at a rate of 100 steps/min, and the middle three steps, free from direction changes, were chosen for data analysis. The same protocol was repeated after wearing Pedar-X (Novel Corporation, Munich, Germany), an insoletype plantar pressure measurement equipment with proven validity. The average maximum pressure (Ppeak, kPa) and the time at which Ppeak appeared (Ptime, %stride) were calculated for each device. The validity of smart insoles was evaluated by using the interclass correlation coefficient (ICC) of Ppeak and Ptime between the two instruments, and Cronbach's alpha was obtained from the Ppeak values to evaluate the reliability. Results: The ICC of Ppeak was 0.651 (good) in the hallux, 0.744 (good) in the medial forefoot, 0.839 (excellent) in the lateral forefoot, and 0.854 (excellent) in the hindfoot. The ICC of Ptime showed 0.868 (excellent) in the hallux, 0.892 (excellent) in the medial forefoot, 0.721 (good) in the lateral forefoot, and 0.832 (excellent) in the hindfoot. All ICC values showed good or excellent results. The Cronbach's alpha of Ppeak measured in the smart insoles was 0.990 in the hallux, 0.961 in the medial forefoot, 0.973 in the lateral forefoot, and 0.995 in the hindfoot; all indicated excellent reliability in all areas. Conclusion: The plantar pressure measurements of smart insoles during walking on a flat ground showed validity compared to Pedar-X, and high reliability after repeated measurements.

Miniaturization of GPS Microstrip Antenna for Small Drone (초소형 드론 탑재용 GPS 대역 마이크로스트립 안테나의 소형화)

  • Kim, Wan-Ki;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.3
    • /
    • pp.62-72
    • /
    • 2022
  • In this study, a miniaturized GPS band(L1 : 1.575 GHz) antenna that can be mounted on a small drone is proposed. The miniaturization was designed by applying the perturbation method based on the λ/4 microstrip antenna and lengthening the current path at the edge of the patch. The miniaturized antenna was fabricatred such that it could be attached to the surface of styrofoam(εr=1.06, t=10 mm) having a size of 10 mm × 9 mm × 10 mm (0.05 λ × 0.05 λ × 0.05 λ). The thickness and length of the feeding line and the spacing between short stubs were adjusted for impedance matching. S11 was found to be -18.8 dB at the center frequency of the fabricated antenna, 1.575 GHz. The radiation pattern measurement results show that the maximum gain of Eθ is 1.87 dBi in 0 directions in the xz-plane, and that Eθ is an omnidirectional characteristic with an average gain of -1.7 dBi in the yz-plane. It was found that the antenna can be used as an ultra-small microstrip antenna, which can be mounted on a small dron for GPS, and is capable of preserving a reduction ratio of 98.8% as compared to a λ/2 microstrip patch antenna.

Experiment and Analysis of Backscattering Signals According to Presence or Absence of Chloroform (클로로폼 침적 유무에 따른 후방산란신호 측정 실험 및 분석)

  • Him Chan Seo;Jee Woong Choi;Yongmyung Kim;Moonjin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.spc
    • /
    • pp.18-22
    • /
    • 2022
  • Because it is difficult to apply direct and optical detection techniques to sunken hazardous and noxious substances (HNS), effective acoustic detection techniques are required to detect sunken HNS in water. In this study, the possibility of acoustic detection of sunken HNS was investigated through backscattering signal measurement experiments using chloroform, a sunken HNS. After establishing a pool in an acrylic tank, backscattering signals were measured according to the presences or absence of chloroform by varying the grazing angle from 90° to 50° in 0.5° intervals using a pan&tilt system. A directional transducer transmitted and received sinusoidal signals with a frequency of 200 kHz and a pulse length of 25 ㎲ in a monostatic state. When chloroform was deposited, the received level of the backscattering signal at the interface between water and chloroform became low at a grazing angle of approximately 80° or smaller. Based on the backscattering signal results obtained at the interface between water and chloroform, the possibility of acoustic detection of sunken HNS was demonstrated.

Neuroprotective effect of Deodeok (Codonopsis lanceolata) bud extracts in H2O2-stimulated SH-SY5Y cells (더덕순 에탄올 추출물의 신경세포 보호 효과)

  • Hee Sun Yang;In Guk Hwang;Ae-jin Choi;Jeong-sook Choe
    • Journal of Nutrition and Health
    • /
    • v.56 no.2
    • /
    • pp.140-154
    • /
    • 2023
  • Purpose: Deodeok (Codonopsis lanceolata) is generally used in conventional medicines and is considered to have remedial properties to cure several diseases. However, application of the C. lanceolata bud as a novel food ingredient has not been fully explored. Hydrogen peroxide (H2O2) is associated with the production of oxidative damage that results in mutagenesis, carcinogenesis, and cell death. This study examines the neuroprotective effect of C. lanceolate bud extracts (CLBE) on H2O2-stimulated apoptosis in SH-SY5Y cells. Methods: C. lanceolata bud of length 10 to 15 cm was collected and extracted using 70% ethanol. Cytotoxicity was evaluated by the EZ-cytox reagent, measurement of lactic dehydrogenase (LDH) release and reactive oxygen species (ROS). The morphological changes of the nuclei were determined using the Hoechst 33258 dye. Enzyme activities were analyzed using the caspase activity assay kit. Related protein expressions were quantified by the Western blot immunoassay in H2O2-stimulated SH-SY5Y cells. Results: Cell viability, LDH release and ROS generation, demonstrated neuroprotective effects of CLBE in H2O2-stimulated SH-SY5Y cells. The occurrence of apoptosis in H2O2-stimulated cells was confirmed by caspase activity, which was increased in H2O2-stimulated SH-SY5Y cells compared to the unexposed group. Pretreatment of CLBE was observed to inhibit the H2O2-stimulated apoptosis. In addition, exposure to CLBE resulted in increased expression of the Bcl-2 (B cell lymphoma 2) protein and decreased expression of the Bax (Bcl2 associated X) protein. Conclusion: This study shows that exposure to CLBE alleviates the H2O2-stimulated neuronal damage in SH-SY5Y cells. Our results indicate the potential application of CLBE in neurodegenerative disease therapy or prevention.

Analysis of Surface Temperature Change and Heat Dissipation Performance of Road Pavement with Buried Circulating Water Piping (열매체 순환수 배관이 매설된 도로 포장체의 표면 온도 변화와 방열 성능 분석)

  • Byonghu Sohn;Muhammad Usman;Yongki Kim
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.2
    • /
    • pp.8-19
    • /
    • 2023
  • Hydronic heated road pavement (HHP) systems have well studied and documented by many researchers. However, most of the systems run on asphalt, only a few are tested with concrete, and there rarely is a comparison between those two common road materials in their heating and cooling performance. The aim of this study is to investigate the thermal performance of the HHP, such as heat dissipation performance in winter season while focusing on the surface temperature of the concrete and asphalt pavement. For preliminary study a small-scale experimental system was designed and installed to evaluate the heat transfer characteristics of the HHP in the test field. The system consists of concrete and asphalt slabs made of 1 m in width, 1 m in length, and 0.25 m in height. In two slabs, circulating water piping was embedded at a depth of 0.12 m at intervals of 0.16 m. Heating performance in winter season was tested with different inlet temperatures of 25℃, 30℃, 35℃ and 40℃ during the entire measurement period. The results indicated that concrete's heating performance is better than that of asphalt, showing higher surface temperatures for the whole experiment cases. However, the surface temperature of both concrete and asphalt pavement slabs remained above 0℃ for all experimental conditions. The heat dissipation performance of concrete and asphalt pavements was analyzed, and the heat dissipation of concrete pavement was greater than that of asphalt. In addition, the higher the set temperature of the circulating water, the higher the heat dissipation. On the other hand, the concrete pavement clearly showed a decrease in heat dissipation as the circulating water set temperature decreased, but the decrease was relatively small for the asphalt pavement. Based on this experiment, it is considered that a circulating water temperature of 20℃ or less is sufficient to prevent road ice. However, this needs to be verified by further experiments or computational fluid dynamic (CFD) analysis.

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Song, Yoon-Ho;Kim, Yoo-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.15-24
    • /
    • 2007
  • Two kinds of temperature monitoring technology have been introduced in this study, which can measure coincidently temperatures at many points along a single length of cable. One is to use a thermal sensor cable comprizing of addressable thermal sensors. The other is to use an optic fiber sensor with Distributed Temperature Sensing (DTS) system. The differences between two technologies can be summarized as follows: A thermal sensor cable has a concept of "point sensing" that can measure temperature only at a predefined position. The accuracy and resolution of temperature measurement are up to the capability of the individual thermal sensor. On the other hand, an optic fiber sensor has a concept of "distributed sensing" because temperature is measured practically at all points along the fiber optic cable by analysing the intensity of Raman back-scattering when a laser pulse travels along the fiber. Thus, the temperature resolution depends on the measuring distance, measuring time and spatial resolution. The purpose of this study is to investigate the applicability of two different temperature monitoring techniques in technical and economical sense. To this end, diverse experiments with two techniques were performed and two techniques are applied under the same condition. Considering the results, the thermal sensor cable will be well applicable to the assessment of groundwater flow, geothermal distribution and grouting efficiency within about loom distance, and the optic fiber sensor will be suitable for long distance such as pipe line inspection, tunnel fire detection and power line monitoring etc.