• Title/Summary/Keyword: length factor

Search Result 2,617, Processing Time 0.023 seconds

Length Optimization for Unconstrained Visco-elastic Damping Layer of Beams (비구속형 점탄성 제진층을 갖는 보의 제진층 길이 최적화)

  • Lee, Doo-Ho;Hwang, Woo-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.12
    • /
    • pp.938-946
    • /
    • 2003
  • Length of an unconstrained viscoelastic damping layer on beams is determined to maximizeloss factor using a numerical search method. The fractional derivative model can describe damping characteristics of viscoelastic damping materials accurately, and is used to represent nonlinearity of complex modulus with frequencies and temperatures. Equivalent flexural rigidity of the unconstrained beam is obtained using Ross, Ungar, Kelvin[RUK] equation. The loss factors of partially covered unconstrained beam are calculated by a modal strain energy method. Optimal lengths of the unconstrained viscoelastic damping layer of beams are identified with ambient temperatures and thickness ratios of beam and damping layer by using a finite-difference-based steepest descent method.

Length Optimization for Unconstrained Visco-elastic Damping Layer of Beams (비구속형 점탄성 제진층을 갖는 보의 제진층 길이 최적화)

  • 이두호;황우석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.665-671
    • /
    • 2003
  • Length of an unconstrained viscoelastic damping layer on beams is determined to maximize loss factor using a numerical search method. The fractional derivative model can describe damping characteristics of the viscoelastic damping material, and is used to represent nonlinearity of complex modulus with frequencies and temperatures. Equivalent flexural rigidity of the unconstrained beam is obtained using Ross, Ungar, Kerwin(RUK) equation. The loss factors of partially covered unconstrained beam are calculated by a modal strain energy method. Optimal lengths of the unconstrained viscoelastic damping layer of beams are obtained with respect to ambient temperatures and thickness ratios of beam and damping layer.

  • PDF

Optimization of Convective Trapezoidal Profile Fin having Fluid inside the Wall (내벽에 유체가 있는 대류 사다리꼴 형상 Fin의 최적화)

  • Jeong Byung-Cheol;Lee Sung-Joo;Yoon Sea-Chang;Kang Hyung Suk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.95-102
    • /
    • 2006
  • This study analyzes and optimizes a design for a trapezoidal profile straight fin using one-dimensional analytical method. The heat transfer, fin length and fin height are optimized as a function of fin volume, fin shape factor and fin base length. In this optimization, convection characteristic number over fin surface and that of fluid inside fin wall are considered. One of the results shows that the maximum heat loss increases as fin volume increases and both fin shape factor and fin base length decrease.

Effective length factors for the framed columns with variable stiffness (골조구성 변단면 기둥의 유효길이 계수)

  • 이수곤;김순철;오금열
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.175-182
    • /
    • 2001
  • Effective length factor approach for framed column design has long played an important design-aid role. This approach, however, is effective only when the columns are in the form of prismatic or uniform cross sections. Structural engineers who have to design or analyse framed columns with variable cross sections need some means to do their job. By using the finite element method, the stability analysis of the isolated compression members with variable cross sections and that of the framed columns are performed. The parameters considered in the stability analysis are taper and sectional property parameters of the columns, the second moment of inertia ratio of beam to column, and beam span to column height ratio. On the basis of the stability analysis results, effective length factor formulas for the columns with variable sections are derived.

  • PDF

Robust Design of an ER Damper using Taguchi Method (다구찌법을 이용한 ER 댐퍼의 강건 설계)

  • 윤영민;배광식;김재환;최승복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.157-162
    • /
    • 2003
  • This Paper presents a robust design of an Electrorheological(ER) damper using Taguchi method. Taguchi method is a robust design method that determines control parameters in the presence of noise effect. Electrode length, electrode gap, base oil viscosity and the weight ratio of ER particles are chosen for the control parameters and the temperature is considered to be a noise factor. The sensitivity of each factor with signal-to-noise(S/N) ratio and analysis of variance are investigated. The analysis results show that the electrode length and base oil viscosity of the ER fluid mostly affect the damping force in the absence of electric field. On the other hand, when the voltage is applied to the ER damper, the electrode length and the weight ratio of ER fluid exhibit significant effect. Based on the Taguchi method, an optimal configuration was designed and the robustness of the designed ER damper was validated by comparing the analysis and experimental results.

  • PDF

Performance of cold-formed steel wall frames under compression

  • Pan, Chi-Ling;Peng, Jui-Lin
    • Steel and Composite Structures
    • /
    • v.5 no.5
    • /
    • pp.407-420
    • /
    • 2005
  • This study presents the strength of braced and unbraced cold-formed steel wall frames consisting of several wall studs acting as columns, top and bottom tracks, and bracing members. The strength and the buckling mode of steel wall frames were found to be different due to the change of bracing type. In addition, the spacing of wall studs is a crucial factor to the strength of steel wall frames. The comparisons were made between the test results and the predictions computed based on AISI Code. The related specifications do not clearly provides the effective length factors for the member of cold-formed steel frame under compression. This paper proposes effective length factors for the steel wall frames based on the test results. A theoretical model is also derived to obtain the modulus of elastic support provided by the bracing at mid-height of steel wall frames in this research.

Prediction of Length of ICU Stay Using Data-mining Techniques: an Example of Old Critically Ill Postoperative Gastric Cancer Patients

  • Zhang, Xiao-Chun;Zhang, Zhi-Dan;Huang, De-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.1
    • /
    • pp.97-101
    • /
    • 2012
  • Objective: With the background of aging population in China and advances in clinical medicine, the amount of operations on old patients increases correspondingly, which imposes increasing challenges to critical care medicine and geriatrics. The study was designed to describe information on the length of ICU stay from a single institution experience of old critically ill gastric cancer patients after surgery and the framework of incorporating data-mining techniques into the prediction. Methods: A retrospective design was adopted to collect the consecutive data about patients aged 60 or over with a gastric cancer diagnosis after surgery in an adult intensive care unit in a medical university hospital in Shenyang, China, from January 2010 to March 2011. Characteristics of patients and the length their ICU stay were gathered for analysis by univariate and multivariate Cox regression to examine the relationship with potential candidate factors. A regression tree was constructed to predict the length of ICU stay and explore the important indicators. Results: Multivariate Cox analysis found that shock and nutrition support need were statistically significant risk factors for prolonged length of ICU stay. Altogether, eight variables entered the regression model, including age, APACHE II score, SOFA score, shock, respiratory system dysfunction, circulation system dysfunction, diabetes and nutrition support need. The regression tree indicated comorbidity of two or more kinds of shock as the most important factor for prolonged length of ICU stay in the studied sample. Conclusions: Comorbidity of two or more kinds of shock is the most important factor of length of ICU stay in the studied sample. Since there are differences of ICU patient characteristics between wards and hospitals, consideration of the data-mining technique should be given by the intensivists as a length of ICU stay prediction tool.

A Study on the Design Factor for Increasing the Dynamic Fit of Slacks (슬랙스의 동적 적합성 향상을 위한 설계 요인 연구)

  • Cho, Sung-Hee
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.2
    • /
    • pp.162-180
    • /
    • 2008
  • The purpose of this study is to find the basic design factors that affect the changes in body surface lines caused by lower limb movements, thereby resulting in slacks that fit well regardless of whether the human form is static or in motion. Using unmarried female university students aged 18-24 as subjects, a total of 32 body surface lines (15 body surface total lines and 17 body surface segment lines) were measured in one static and 9 movement poses, The analysis first involved the calculation of the expansion and contraction rates per body part in body surface line in 9 lower limb movements, Second, a factor analysis was conducted using the expansion and contraction rates of these changes in body surface line. The results of this study are as follows, According to the factor analysis, basic design factors that affect changes in body surface lines comprised 8 types of factors as illustrated in fig, 2-fig, 9, which explained 79.2% of total variate for the variables studied, Factor 1, comprising the lower segment of center back leg line, center front leg line and inner leg line, and lower limb girth except midway thigh girth and ankle girth below hip girth, accounted for 30.3% of total variance, Factor 2, comprising waist girth, the total and upper segment of center back leg line and center tront leg line, and front and back segment of crotch length, explained 17.4% of total variance, Factor 3, the total and upper segment of lateral leg line at the center, accounted for 56.5% of total variance in accordance with Factors 1, 2, and 3, Factor 4 was the contracting upper part of lower leg between legscye girth and midway thigh girth, Factor 5 comprised the total and upper segment of inner leg line and posterior knee girth, Factor 6 was the total crotch length, Factor 7 was the ankle girth, Factor 8 was the abdomen girth.

Study of Real Somatotype and Perceived Body Classified by Body Index of College Women (여대생(女大生)들의 지수치(指數値)에 의한 체형(體型) 집단(集團)별 실제체형(實際體型)과 신체인식(身體認識)에 관한 연구(硏究))

  • Lee, Jung-Soon
    • Journal of Fashion Business
    • /
    • v.11 no.5
    • /
    • pp.100-109
    • /
    • 2007
  • The purpose of this research is to study the recognition of real somatotype and body of college women. The study was carried out by classifying somatotypes into three categories based on the body index; slim, normal, and obese somatotype. The subject of this study was 106 college women, and real measurement and survey were used. Data was analyzed by SPSS 12.0 and cross tabulation analysis, t-test, Anova, and correlation analysis were operated. The result is as follows. 1. The height of the subjects was 163.5cm, weight was 53.3kg, Rohrer index was 1.2, BMI was 19.9, Vervaeck index was 84.4 and the classification based on the body index belonged to the normal group. 2. The characteristics of groups divided by the body index are that slimmer groups is longer in length factor and smaller in the factors related with volume than other groups. The characteristics of groups classified by self-consciousness shows significant difference in all girth factors, back intersyce breadth, front intersyce breadth, neck to nipple length, and nipple to nipple breadth. 3. Conscious about the somatotype with using body index generally shows similarity. In the length factor including height, slim somatotype group is perceived as longer than normal somatotype group, and in the girth factor including weight, normal somatotype group is recognized as bigger and thicker than others.

A Change in the Area and External Length of the Shape of Sleeve according to Arm Movements (팔 동작에 따른 소매의 착의 면적 및 외관 길이 변화)

  • Lee, Myung-Hee
    • Fashion & Textile Research Journal
    • /
    • v.12 no.5
    • /
    • pp.619-625
    • /
    • 2010
  • The purpose of this research is to analyze the shapes of blouse with above-elbow sleeves according to arm movements. The shapes include five types of the arm movement(basic posture, reach forward 45, 90, and reach lateral 45, 90) in the stand-posture, which were made by different adaptability of clothes. Experiments were conducted to figure out the dressed shape through 3-D measurement Vivid 910, and also to investigate the area of the shape of sleeves on the section map and the diagonal length of the block made by the basic section line in lateral part of sleeve with Rapid Form 2004, a software for 3-D shape analysis. The Data were analyzed by factor analysis, Anova, Duncan test, t-test. The results of this study were as follows: First, the area of sleeve was briefed 3 factor; front, center, back in sleeve. Second, there were different effect of arm movement, section level and part of shapes in the area of sleeve. Third, the diagonal length was briefed 4 factor; back, back-center, front-center, front. Forth, after t-test, there were statistically significant between the reach forward and lateral and between the angles of arm reach.