• Title/Summary/Keyword: leakage test

Search Result 1,007, Processing Time 0.03 seconds

Leakage Failure Determination Method of Pilot Pneumatic Directional Control Valve (파일럿형 공기압 방향제어 밸브의 누설 고장판정 기법에 관한 연구)

  • Kang, Bo Sik;Kim, Kyung Soo;Chang, Mu Seong
    • Journal of Applied Reliability
    • /
    • v.14 no.4
    • /
    • pp.230-235
    • /
    • 2014
  • The failure modes of pneumatic directional control valves include leakage, wear of the spool seal, and sticking of the spool. Among them, the main failure mode of the valve is leakage. The leakage is caused by the wear of the spool seal. However, due to the characteristics of the seal material, the leakage rate is fluctuated a lot rather than constantly increased over time. If life analysis is performed using the first time data of leakage failure, predicted life cycles can be different from the real life cycles. This paper predicts life cycles of the pilot pneumatic directional control valve based on the three point moving average which considers the average of the fluctuating leakage rate.

Acceptance Test of a Mechanical Face Seal for Turbopumps (터보펌프용 미케니컬 페이스 실의 수락시험)

  • Kwak, Hyun-D.;Jeon, Seong-Min;Kim, Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.1 s.40
    • /
    • pp.20-25
    • /
    • 2007
  • A mechanical face seal has been tested in Korea Aerospace Research Institute for turbopump applications. In this paper the acceptance test results of the mechanical face seal are described. By means of simulating a practical operating environment, the performance against leakage of mechanical face seal is monitored. In addition the carbon wear is measured to estimate the life of a mechanical face seal. The test results show the acceptable leakage performance and resonable wear tendency as well. Lastly the repeated test had been carried out to guarantee the endurance performance of mechanical face seal based on the turbopump life.

Dynamic Boric Acid Corrosion of Low Alloy Steel for Reactor Pressure Vessel of PWR using Mockup Test (가압형 경수로 압력용기 재료인 저합금강의 동적 붕산 부식 실증 연구)

  • Kim, Sung-Woo;Kim, Hong-Pyo;Hwang, Seong-Sik
    • Corrosion Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.85-92
    • /
    • 2013
  • This work is concerned with an evaluation of dynamic boric acid corrosion (BAC) of low alloy steel for reactor pressure vessel of a pressurized water reactor (PWR). Mockup test method was newly established to investigate dynamic BAC of the low alloy steel under various conditions simulating a primary water leakage incident. The average corrosion rate was measured from the weight loss of the low alloy steel specimen, and the maximum corrosion rate was obtained by the surface profilometry after the mockup test. The corrosion rates increased with the rise of the leakage rate of the primary water containing boric acid, and the presence of oxygen dissolved in the primary water also accelerated the corrosion. From the specimen surface analysis, it was found that typical flow-accelerated corrosion and jet-impingement occurred under two-phase fluid of water droplet and steam environment. The maximum corrosion rate was determined as 5.97 mm/year at the leakage rate of 20 cc/min of the primary water with a saturated content of oxygen within the range of experimental condition of this work.

Development and Performance Test of Online Electrical Safety Monitoring System Applying an Algorithm to Measure Resistive Leakage Currents using Phase Differences (위상차를 이용한 저항성 누설전류 측정 알고리즘을 적용한 온라인 전기안전 감시시스템의 개발 및 성능시험)

  • Yoo, Jeong Hyun;Kim, Hie Sik;Jeong, Yong Wook
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.27-32
    • /
    • 2018
  • Nowadays, to prevent electrical accidents in Korea, inspectors directly performed checking general electrical facilities as a cycle from every one to three years. It is difficult to presuppose an omen because intact conditions of electrical equipments are not kept at the time of inspection. In this paper, in order to ensure effectiveness of an online basis electric inspection, we developed an electrical safety IoT system using LoRa communication technology to enable monitoring mainly electrical safety components such as overcurrent, overvoltage, resistive leakage current, and power. Then we proposed a method for verifying performances of the prosed electrical safety IoT system. Resistive leakage currents are calculated by using difference of phase between voltages and currents. We verified that average errors are 0.97%, which reference goal is ${\pm}5%$ for a device, through reliability test according to conditions. Results of this research can be used as basic study materials to develop technologies for measuring three phase leakage current and for implementing public electrical safety. platform.

Study on Leakage Analyses and Experimets on a Main Oxidizer shut-off Valve (산화제 개폐밸브 플랜지 기밀 해석 및 시험에 관한 연구)

  • Yoo, Jae-Han;Hong, Moon-Geun;Bae, Young-Woo;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.251-253
    • /
    • 2010
  • In the leakage test of a Main Oxidizer shut-off valve, gas leakage was found on the middle flange with a metal conical seal. The structural analysis was performed for three models with different numbers of bolts and flange shapes and then one model was selected in consideration of the minimum axial gap deformation as well as the weight increment due to the change of flange shapes. Experimental leakage tests for the simulated flanges of the selected model has resulted in no gas leakage, and consequently the structural analysis method for the design of the middle flanges has proved feasible.

  • PDF

A Performance Evaluation of Zone Smoke Control Systems for Railway Underground Transit Passage by Smoke Control TAB (제연 TAB를 통한 철도 지하환승통로의 거실제연설비 성능평가)

  • Seol, Seok-Kyun;Kim, Joon-Hwan;Park, Min-Seok;Oh, Seung-Min;Ahn, Yong-Chul;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • This study conducted Testing, Adjusting, and Balancing (TAB), which is a type of field performance evaluation experiment of a zone smoke-control system, at a railway underground transit passage installed with a zone smoke- control system to find problems and improvements for ensuring performance. TAB for the smoke control system was classified into several procedures, such as design data review, duct leakage test, field measurement of the airflow rate, velocity of the fan and duct, and a smoke test. Through the duct leakage test, the system leakage ratio was examined to prove the duct sealing. The iImprovement of the smoke control airflow problems due to the lack of fan static pressure loss was the secured performance. The performance of the smoke control fan was secured by improvements of the smoke control airflow rate problems caused by the loss of static pressure in the intake duct. The smoke test in the smoke control zone confirmed that the damper operating schedule subject was influenced by natural wind or train wind.

A Study on a Quality Characteristics of Pressure Leak Test of Process Piping for Offshore Plant (해양플랜트 프로세스 배관 Pressure Leak Test의 품질 특성에 관한 연구)

  • Park, Chang-Soo;Kim, Hyungwoo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.429-437
    • /
    • 2018
  • The process gas piping of the offshore plant can cause a massive explosion if the gas leakage occurs during operation. For the purpose of precaution of gas leakage accident, an air pressure test is performed on the process equipment tests using a test pump as much as the power to the piping inner side, mix 99% nitrogen gas and 1% helium gas. The purpose of the air pressure test is to check the work conformity process by handling and regulation for initial piping process, assembly, installation of module, welding, center alignment of the pipes assembling flange gasket in an unrestrained free state. In this paper, the regulation of the problematic air pressure test was analyzed and the solution criteria were established. And leakage tests of existing equipment were performed applying these solution methods. As a result, it was confirmed that there was no problem.

Inter Propellant Seal Performance test for 75 ton Class Turbopump (75톤급 터보펌프 추진제 혼합 방지 실의 성능 시험)

  • Jeon, Seong-Min;Kwak, Hyun-Duck;Park, Min-Joo;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.5
    • /
    • pp.57-64
    • /
    • 2010
  • A performance test of inter propellant seal for a 75 ton class turbopump is conducted using water to evaluate leakage and endurance performance. Each part of fuel pump side and oxidizer pump side for a prototype inter propellant seal has been tested for verifying endurance performance during total accumulated test time 2,100 sec in water. The fuel pump side part with one-stage seal of carbon floating ring shows average leakage rate 13.7 gram/sec under average seal differential pressure 9.4 bar. On the other hand, the oxidizer pump side part with two-stage seal assembly of carbon floating rings shows average leakage rate 7.3 gram/sec under average seal differential pressure 9.5 bar. After the endurance performance test, the inter propellant seal shows good physical condition. A leakage performance test of the inter propellant seal for cryogenic environment will be performed using LN2 in the near future.

Inter Propellant Seal Performance test for 75 ton Class Turbopump (75톤급 터보펌프 추진제 혼합 방지 실의 성능 시험)

  • Jeon, Seong-Min;Kwak, Hyun-Duck;Park, Min-Joo;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.47-53
    • /
    • 2010
  • A performance test of a 75 ton class turbopump inter propellant seal is conducted using water to evaluate leakage and endurance performance. Each fuel pump side part and oxidizer pump side part of a prototype inter propellant seal has been tested for verifying endurance performance during total accumulated test time 2,100 sec in water. The fuel pump side part with 1 stage carbon floating ring seal shows average leakage rate 13.7 gram/sec under average seal differential pressure 9.4 bar. On the other hand, the LOx pump side part with 2 stage carbon floating ring seal shows average leakage rate 7.3 gram/sec under average seal differential pressure 9.5 bar. After the endurance performance test, the inter propellant seal shows good physical condition. A cryogenic leakage performance test of the inter propellant seal will be performed using LN2 in the near future.

  • PDF

High Temperature Characteristics of submicron GaAs MESFETs (고온 동작 MESFET 의 온도특성 해석)

  • 원창섭;유영한;신훈범;한득영;안형근
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.379-382
    • /
    • 2002
  • GaAs has wide band gap, Therefore that malarial can used high Temperature application. in this paper explain to current-voltage characteristics of thermal effect. we experiment on thermal test of current-voltage characteristics and gate leakage current with real device. As a result, we propose a current-volatage characteristics model. that model base on gate leakage current, and gate leakage current influence gate source voltage.

  • PDF