• 제목/요약/키워드: leakage test

검색결과 1,007건 처리시간 0.03초

누설전류 측정을 통한 옥외절연물 오손도 측정 (Study for Measurement of Polluted Outdoor Insulations Using Leakage Current)

  • 이부원;김성중;박우용;김영달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2068-2069
    • /
    • 2007
  • This study describes a compairison leakage current properties between a polluted insulator and insulator subjected to salt polluted condition. Exposure tests at a sea coast test and the leakage current of insulators, climate conditions, and salt deposit density were measured during the tests. Appearance of leakage current for the insulator was affected by the humidity and the salt deposition on the surface. comparison of leakage current under salt polluted conditions. salt polluted test and humidity tests were carried out in laboratory using the same insulator profiles in oder to determine the leakage current patterns during critical conditions

  • PDF

은나노입자에 대한 방진마스크 포집효율 및 총누설율 (Filtration efficiency and Manikin-based Total Inward Leakage Study of Particle Filtering Mask Challenged with Silver Nanoparticles)

  • 김종규
    • 한국산업보건학회지
    • /
    • 제26권3호
    • /
    • pp.367-376
    • /
    • 2016
  • Objectives: The production and use of nanoparticles have been increased. In 2014 Workplace Survey Results, 335 companies produce and treat nanoparticls. However, lack of data on nano-toxicity and a method for risk management and regulation on nanoparticles and the standard test method are not sufficient. Protective equipment selection guidelines for nanoparticles are not established. It is required to carry out respirator efficiency test against nanoparticles. This study was performed to evaluate filtration efficiency and manikin-based total inward leakage of particle filtering mask using in Korean country challenged with silver nanoparticles. Methods: We investigated filtration efficiency and total inward leakage of 7 respirator with silver nanoparticle. Results: The geometric mean diameters of Silver nanoparticles were 30 nm and number concentration were about $10^6{\sharp}/cm^3$. Filtration efficiency of six of the seven particle filtering masks was more than 98% and one particle filtering masks filtration efficiency was 94.9%. The filtration efficiency of particle filtering masks to 20 nm silver nanoparticels was highest. Artificial breathing machine with manikin based total inward leakage were 7.6% ~ 42.3%. Conclusions: The results of this study nano-silver filter efficiency was high but the total inward leakage was higher than filter penetration. Therefore, education on how to wear a respirator should be demanded. Especially for workers handling nanoparticles and toxic material, user seal checking and fit test must be performed.

원전 격납건물 누설시험용 무선데이터전송을 적용한 시험장치 개발 (Leakage Rates Measurement System Development of NPP Primary Containment using Wireless Data Communication Method)

  • 류재규;손창호;황희정;김건수;최경식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.916-919
    • /
    • 2003
  • In this paper, we deal with a development of measurement system to apply the leakage rates test of primary containment in nuclear power plant. The measurement test about leakage rates in primary containment is one sort of test to prove safety of nuclear power plant. The parameters which are measured to calculate leakage rates are drybulb temperature, dew point temperature(or relative humidity), absolute pressure and flow. Overall, the measurement system consists of sensor module for data acquisition of the parameters, transfer module for wireless data communication and control module to control system and to calculate leakage rates. Because existing measurement systems are difficult to set in field, we pursued convenience of use, we applied wireless data communication and individual form module using battery. We also changed for the better in confidence. Recently, we are developing a drybulb temperature and a dew point temperature sensor module. We describe about function of developed measurement system, its standard and an plan for verification of measurement system.

  • PDF

고온.고압용 3-way 볼밸브의 특성해석 (A Characteristic Analysis of High Pressure and High Temperature 3-way Ball Valve)

  • 이준호
    • 한국기계가공학회지
    • /
    • 제11권4호
    • /
    • pp.180-184
    • /
    • 2012
  • 3-way ball valves have been mostly used for high temperature/high pressure valves using in petrochemical carriers and oil tankers, which requires high quality products with confidentiality and durability. As a larger disaster may be generated by leakage of oil or gas from valves, thus the present research applied a numerical analysis method with thermal-structural coupled field analysis and the performance test. The Max stress by parts was confirmed through thermal-structural coupled field analysis and develop the 3-way ball valve design, which is safe on operating condition. And its performance was verified by carrying out pressure test, leakage test and durability test for the manufactured 3-way ball valves with satisfying it's regulations.

점착유연형 고무 아스팔트계 누수보수용 주입형 실링재의 내화학 시험방법 개선 연구 (A Study on Chemical Resistance Test Method of the Adhesively Flexible Rubberized Injection Seal for Water Leakage Cracks in Concrete Structures)

  • 박완구;김동범;박진상;김선도;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.240-241
    • /
    • 2017
  • In this stduy, we will references to provide reasonable basis for the test environments applicable to the chemical resistance test covered by KS F 4935 『Injection-type Sealing Materials for Water Leakage Crack of Adhesive and Flexible Rubber Asphalt』, analyze the problems with the current test methods in consideration of the features of materials. As a result, we assured more objective data in improved chemical resistance test methods.

  • PDF

Sealing Ability of Three Different Materials Used as Retrograde Filling

  • Park, Ji-Hoon;Kang, Seung-Bok;Choi, Yong-Hoon;Bae, Ji-Hyun
    • Journal of Korean Dental Science
    • /
    • 제5권2호
    • /
    • pp.60-67
    • /
    • 2012
  • Purpose: To test the apical leakage prevention performance of three different materials through protein leakage procedures using bovine serum albumin (BSA) and Bradford protein reagent. Materials and Methods: A total of 60 human single-rooted teeth were divided into 4 groups, and conventional root canal filling was done. The root was cut 3 mm from the apex, and a cavity was formed. Proroot MTA (MTA), Fuji II LC (GI), Fuji II LC with XP bond (GIA), and Caviton (CA) were used as experimental materials to fill the cavity in a retrograde filling manner. The extent of BSA leakage was then measured with a ultraviolet visible spectrophotometer 24, 48, and 72 hours after filling. Result: After 24 hours, among the 15 teeth of each group, 2 in MTA, 4 in GI, 3 in GIA, and 7 in CA showed leakage. After 48 hours, 3 in MTA, 5 in GI, 5 in GIA, and 10 in CA had leakage and discoloration. After 72 hours, among the 15 teeth of each group, 3 in MTA, 6 in GI, 5 in GIA, and 10 in CA showed leakage. The leakage in the CA group was greater than that in the MTA group at 48 and 72 hours based on Fisher's exact test (P=0.025), and the difference was statistically significant. Similarly, the leakage in the CA group was greater than that in the MTA group over time based on the Kaplan-Meier survival estimate (P=0.011), and the difference was statistically significant. Conclusion: Glass ionomer, glass ionomer after adhesive application, and MTA all showed leakage. Caviton showed greater leakage compared to MTA 48 and 72 hours after filling, and the difference was statistically significant; thus suggesting that Caviton is not appropriate as retrograde filling material considering its sealing ability.

연료전지자동차의 고압수소저장시스템 수소 누출 안전성 평가 (The Evaluation of Hydrogen Leakage Safety for the High Pressure Hydrogen System of Fuel Cell Vehicle)

  • 김형기;최영민;김상현;심지현;황인철
    • 한국수소및신에너지학회논문집
    • /
    • 제23권4호
    • /
    • pp.316-322
    • /
    • 2012
  • A fuel cell vehicle has the hydrogen detection sensors for checking the hydrogen leakage because it use hydrogen for its fuel and can't use a odorant to protect the fuel cell stack. To verify the hydrogen safety of leakage we select the high possible leak points of fittings in hydrogen storage system and test the leaking behavior at them. The hydrogen leakage flow rate is 10, 40, 118 NL/min and the criterion for maximum hydrogen leakage is based on allowing an equivalent release of combustion energy as permitted by gasoline vehicles in FMVSS301. There are total 18EA hydrogen leakage detection sensors installed in test system. we acquire the hydrogen leakage detection time and determine the ranking. Hydrogen leakage detection time decrease when hydrogen leakage flow rate increase. The minimum hydrogen leakage detection time is about 3 seconds when the flow rate is 118NL/min. In this study, we optimize hydrogen sensor position in fuel cell vehicle and verify the hydrogen leakage safety because there is no inflow inside the vehicle.

지하구조물에 적용하는 누수균열 보수용 방수씰의 성능평가 방법에 관한 연구 (A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Cracks Repairing Material using on the Underground Structure)

  • 권시원;권기주;이종용;오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.652-655
    • /
    • 2004
  • In these days, repair materials for leakage cannot help but being taken in temporary way without any noticeable countermeasure. This kind of repair is socially criticized many times that is defective construction even if tills costs a lot. It was not arrange the standard for performance evaluation test method and quality maintenance for materials, even it has been used various injection repairing agent. In conclusion, We suggest that the test method for repair materials for leakage to establish the leakage repairing technology as increase of structure demand, so that the necessity of the establishment of the quality control standard and the performance testing way on the relevant water-proof seal is increasing a lot to regulate the water-proof technology and the leakage repair technology.

  • PDF

흡습된 수냉각 발전기 고정자 권선의 전기적 특성 (Electrical Properties of Wet Bars in Water-cooled Generator Stator Windings)

  • 김병래;김희동
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.817-823
    • /
    • 2012
  • Insulation breakdown of water-cooled generator stator windings occurs frequently due to leakage of cooling water and absorption into the insulation material. Leakage and absorption problems of water-cooled stator windings are often found during regular preventive maintenance. To evaluate cooling water leakage and absorption, diagnostic tests were performed on two water-cooled turbine generators, which have been in service for 13 and 17 years, respectively. The test results of the measured electrical properties such as dissipation factor($tan{\delta}$), capacitance and AC leakage current for water-cooled generator stator windings with wet bars are reported in this paper.

Validation of a new magnetometric survey for mapping 3D subsurface leakage paths

  • Park, DongSoon;Jessop, Mike L.
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.891-902
    • /
    • 2018
  • Techniques for more reliable detection of 3D subsurface flow paths are highly important for most water-related geotechnical projects. In this case study, a magnetometric resistivity method with a new approach and state-of-the-art technology ("Willowstick survey") was applied to the testbed dam (YD dam) site, and its applicability was validated by geotechnical investigation techniques including borehole drilling and sampling, Lugeon test, flow direction and velocity test, and seismic tomography. In addition to the magnetometric survey, a 3D electrical resistivity survey was performed independently and the results were compared and discussed. The electrical resistivity survey was effective in detecting groundwater levels, but it was limited in mapping leakage paths. On the other hand, the Willowstick magnetometric survey effectively detected geologic weaknesses (e.g., fault fracture) and potential leakage paths of the dam site foundation rocks. The results of this research are expected to be effective for water infrastructures where leakage is an important issue.