• 제목/요약/키워드: leakage test

검색결과 1,007건 처리시간 0.027초

역방향스월자기주입 시일의 누설 성능에 관한 실험 연구 (Test Results of Leakage Performance for Anti-Swirl Self-Injection Seals)

  • 김창호;이용복
    • Tribology and Lubricants
    • /
    • 제7권2호
    • /
    • pp.41-45
    • /
    • 1991
  • An experimental investigation for leakage performance of five anti-swirl self-injection seals was carried out to select an optimum configuration for minimum leakage. Test results show that the self-injection mechanism with a plain seal generally degrades the leakage performance of noncontacting seals; however, through a series of the test program, an optimum anti-swirl self injection seal was selected to obtain a comparable leakage performance with a damper seal. A 12 holes anti-swirl and anti-leakage self-injected. configuration with a labyrinth surface gives minimum leakage among the tested anti-swirl self-injection seals.

플로팅 링 실의 누설 특성에 관한 실험적 연구 (Experimental Study on the Leakage Performance Characteristics of Floating Ring Seal)

  • 안경민;이용복;김창호;하태웅
    • Tribology and Lubricants
    • /
    • 제20권4호
    • /
    • pp.183-189
    • /
    • 2004
  • The floating ring seal is used in an oxidizer and a fuel pump of the turbo pump unit in the liquid rocket engine to optimize a leakage without rubbing phenomenon. The damper floating ring seal, one of the floating ring seals, is with round hole pattern surfaces. It can reduce the leakage by increased friction factor that obtained from experimental data. In this paper, the leakage test about floating ring seal and damper floating ring seal was conducted. The test result showed the leakage performance of damper floating ring seal was better than the leakage performance of floating ring seal. With the leakage test the lock-up and rotation test about seal was conducted and that position is measured. The relatively large lock-up eccentric ratio was obtained from the test result of damping floating ring seal. The attitude angle of seal increases with increasing of shaft rotation.

플로팅 링 실의 누설 특성에 관한 실험적 연구 (Experimental Study on the Leakage Performance Characteristics of floating Ring Seal)

  • 안경민;이용복;김창호;하태웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.820-825
    • /
    • 2004
  • The floating ring seal is used in an oxidizer and a fuel pump of the turbo pump unit in the liquid rocket engine to optimize a leakage without rubbing phenomenon. The damper floating ring seal, one of the floating ring seals, is with round hole pattern surfaces. It can reduce the leakage by increased friction factor that obtained from experimental data. In this paper, the leakage test about floating ring seal and damper floating ring seal was conducted. The test result showed the leakage performance of damper floating ring seal was better than the leakage performance of floating ring seal. With the leakage test the lock-up and rotation test about seal was conducted and that position is measured. The relatively large lock-up eccentric ratio was obtained from the test result of damping floating ring seal. The attitude angle of seal increases with increasing of shaft rotation

  • PDF

Investigation of Leakage Characteristics of Straight and Stepped Labyrinth Seals

  • Kim, Tong-Seop;Kang, Soo-Young
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권3호
    • /
    • pp.253-259
    • /
    • 2010
  • Leakage characteristics of two labyrinth seals with different configurations (straight vs stepped) were investigated. Leakage flows were predicted by computational fluid dynamics (CFD) for the two configurations and compared with test data. A semi-analytical leakage prediction tool was also tried to predict the leakage. It was confirmed that the CFD gives quite good agreements with test data. The analytical tool also yielded similar leakage behaviors with test results, but the overall agreement with test data was not as good as that of the CFD. The effect of flow direction in the stepped seal on leakage flow was examined. The dependence of leakage performance, in terms of flow function, on the seal clearance size was investigated. Flow function decreased with decreasing clearance in the straight seal, while the trend was reversed in the stepped seal.

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • 유공압시스템학회논문집
    • /
    • 제5권1호
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF

격납건물 종합누설률 예측방법 평가 (Evaluation of Prediction Methods for Containment Integrated Leakage Rate)

  • 양승옥;이광대;오응세
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.562-564
    • /
    • 2004
  • The containment leakage rate test performed on the nuclear power plants consists of following phases : pressurizing the containment, stabilizing the atmosphere, conducting a Type A test, conducting a verification test, depressurizing the containment. It takes more than 48 hours from the pressurization to the depressurization and the prediction of the results will help to prepare the next test phase. In this paper, to predict the leakage rate, the prediction methods based on the least square method are evaluated according to the input variables and the measurement period.

  • PDF

피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구 (A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester)

  • 정기석;길형준
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

스팀터빈용 래비린스 실의 누설량 규명을 위한 공기상사 실험 및 해석 (Air Similarity Test and Analysis of Steam Turbine Labyrinth Seal for Leakage Verification)

  • 안상규;김승종;이용복;김창호;하태웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1149-1149
    • /
    • 2006
  • The leakage characteristic is an important factor in power plant. However, most of power plant have efficiency problem which is occurred leaking between high pressure steam turbine axle and stator. The labyrinth seal which is used between the main turbine axle and stator in the power plant. Because it is able to be non-contact seal and it is minimize clearance to decrease the leakage. But its actual system is too huge to experiment. Therefore, most steam turbine seal performance tests were conducted by air similarity test. This paper described a test facility and program for air similarity test of high pressure steam turbine seal. A test facility has been designed and built to evaluate leakage verification of labyrinth seal. The test facility consist of air compressor, anti-swirl labyrinth seal for 1/3 air similarity model, pressure transducer, air flow measure system, instrumentation and auxiliary system. For evaluation of steam turbine seal performance, the air similarity test of labyrinth seal leakage verification was conducted and we compared experiment data and analysis result.

  • PDF

압력용기 수압 및 기밀시험 자동화 시스템 개발 (Development of Automation System of Water-Hydraulic and Leakage Test for Pressure Vessel)

  • 이원희;김동수;이승현;김광영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1672-1675
    • /
    • 2003
  • In this study, we developed full automation test system for pressure vessel. This pressure vessel containing oxygen, nitrogen and carbon is widely used in industrial field. The test items of pressure vessel are divided into three branches which is weight measurement, water-hydraulic, and leakage test. After leakage test is completed, cleaning and dry progress is carried out. And control system is consist of three controller which is PLC, monitoring system and database system. PLC is control all of system. Monitoring system measures weight, pressure, flow etc and display to all conditions. Database system stores tested data. we design system to control all test modules in communication by a second period with three control modules. Finally, we verified this system by field test.

  • PDF

A new method fast measure cryogenic vessel heat leakage

  • LI, Zheng-Qing;LI, Xiao-Jin;LIU, Mo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.24-28
    • /
    • 2020
  • Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.