• 제목/요약/키워드: leakage sound

검색결과 61건 처리시간 0.029초

본인부담상한제 적용 요양병원 환자의 의료이용가수요 예측요인 분석 (An Aanalysis of Predictive Factors of Medical Service Overuse for Inpatients Applied Out-of-Pocket Maximum in Long-Term Care Hospitals in South Korea)

  • 임승지;신한나
    • 보건행정학회지
    • /
    • 제30권1호
    • /
    • pp.72-81
    • /
    • 2020
  • Background: The out-of-pocket maximum is one of the distinctive healthcare systems which sets a ceiling on co-payment in order to reduce the burden of households from the unpredictable medical expenditure. However, this leads to an increase in the demand for healthcare services especially in long-term care hospitals (LTCHs) in Korea. Methods: This study analyzed the influence factor of medical service overuse of 165,592 inpatients in LTCHs which out-of-pocket maximum is applied, by utilizing data from the National Health Insurance Service (2016). Based on Anderson Model, the medical service overuse, as a dependent variable, was defined as long-stay admission more than 180 days at the LTCHs. Independent variable was comprised of predisposing factors (gender, age), enabling factors (income level, types of out-of-pocket maximum) and need factors (illness level, patient use of tertiary hospital). Results: The most powerful factor of medical service overuse in LTCHs was availability of pre-payment for the out-of-maximum (odds ratio [OR], 191.66; p<0.001). This tendency was found in high income level status (p<0.001). Furthermore, mild inpatients (OR, 1.50; p<0.001) which had no experience with the tertiary hospitals (OR, 2.06; p<0.001) were more relevant to the medical service overuse in LTCHs, compared to the severe inpatients. Conclusion: It is suggested that a separate standard of out-of pocket maximum with regards to LTCHs is required to secure the beneficial functions of long-term hospitals and prevent unnecessary financial leakage to achieve sustainable and financially sound National Health Insurance.

저압확장파 검출을 통한 배관 누출 및 누출위치 예측 (Leak and Leak Point Prediction by Detecting Negative Pressure Wave in High Pressure Piping System)

  • 하태웅;하종만;김동혁;김영남
    • 한국가스학회지
    • /
    • 제11권4호
    • /
    • pp.47-53
    • /
    • 2007
  • 고압 가스 배관망의 안전관리는 매우 중요한 문제로 배관의 외적 손상으로 구멍이 생길 경우 발생하는 누출은 폭발 및 환경오염을 포함한 막대한 경제적 손실을 야기할 수 있다. 누출 검지를 위한 PLDS(Pipeline leak detection system린 기술로 저압확장파 검지 기술이 적용되고 있으며 본 논문에서는 CFD++ 상용코드를 활용하여 배관 누출시 유동특성을 이론적으로 해석하여 저압확장파의 발생 메커니즘과 음속으로 확장되는 전파특성을 규명하였다. 또한 긴 배관망에 적용하기 위한 1차원 해석 방법을 제시하고 신뢰성을 CFD해석 결과로 검증하였다.

  • PDF

유치와 영구치에 수복된 레진과 글라스 아이오노머 수복물의 미세누출 양상에 관한 비교연구 (A COMPARISON OF GLASS IONOMER vs RESIN RESTORATION IN MICROLEAKAGE PATTERN OF PRIMARY AND PERMANENT TEETH)

  • 전경현;김종수;김용기
    • 대한소아치과학회지
    • /
    • 제25권1호
    • /
    • pp.47-61
    • /
    • 1998
  • The purpose of this study was to compare the microleakage pattern of glass ionomer with resin restoration in microleakage pattern of primary and permanent teeth. Microscopical observation of interface between tooth structure and restoration was also performed. 80 and 8 sound molar teeth were used for the microleakage test and SEM study respectively. Data were analyzed statistically using ANOVA test and/or t-Test. The results of the present study were as follows: 1. According to the result of microleakage pattern between primary and permanent tooth, primary tooth generally showed more micro leakage than permanent tooth in all groups (p<.05). 2. In the resin-filled groups, occlusal margin was shown to have more microleakage than gingival margin(p<.05). Whereas the glass ionomer-filled groups showed no statistically significant differences between them(p>.05). 3. No statistically significant differences in microleakage could be found between two different resin groups(p>.05), while Fuji II LC group showed less microleakage than Ketac-Fil group(p>.05). 4. The various type hybrid layer was evident under SEM in resin-filled groups both in primary and permanent teeth with generally thicker layer in primary group. Among glass-ionomer group, Fuji II LC group showed more intact adhesion to tooth surface than Ketac-Fil group

  • PDF

중고 스마트폰을 활용한 스마트 팜 시스템의 구현 (Implimentation of Smart Farm System Using the Used Smart Phone)

  • 권성갑;강신출;탁한호
    • 한국정보통신학회논문지
    • /
    • 제22권11호
    • /
    • pp.1524-1530
    • /
    • 2018
  • 본 논문에서는 중고 스마트폰을 세계 최초로 IoT 사물통신기술과 융합하여 그린 IT 솔루션을 상용화함으로써 환경오염과 자원낭비 및 외화유출을 막을 수 있는 제품으로 설계하였다. 제안한 시스템의 실험을 위하여 실제 농작물 재배 시설내에 설치하여 여러 가지 기능과 통신 상태를 실험하였다. 그 결과 문제점이 발생될 경우에 사용자의 스마트폰으로 경보음 및 동영상 알림이 발생되며, 또한 각종 설치된 기기들의 원격제어와 실시간으로 데이터 분석이 가능하였다. 본 연구에서 중고 스마트폰의 활용을 위해 개발된 단말기 관리보드는 농업이나 환경 등의 다양한 분야에 응용이 가능하리라 사료된다.

무인감시설비를 위한 유지보수 자동화 점검 시스템 (Automated Maintenance Inspection System for Unmanned Surveillance Equipment)

  • 채민욱;이충호
    • 융합신호처리학회논문지
    • /
    • 제22권1호
    • /
    • pp.1-6
    • /
    • 2021
  • 최근에 IT 기술의 발전과 비용을 절감하는 방식으로 무인감시설비가 도입되어 운영되고 있다. 무인감시설비는 효율적이고 경제적인 측면으로 장점이 있지만, 무인감시설비의 고장, 오작동이 발생하면서 감시 공백과 침입자로 인한 시설 파손 및 정보 유출 등 피해가 발생 되는 단점이 있다. 그리고 무인감시설비의 점검 차원에서 담당자의 상시 방문이 필요하고 이에 따른 관리 비용이 발생하고 있다. 본 논문에서는 무인감시설비의 상태를 실시간 점검하여 오작동과 같은 문제를 감시설비의 상태 확인 및 자동복구하고 담당자에게 실시간으로 상황을 문자메시지로 통보하는 시스템을 설계하였다. 설계할 시스템은 영상, 음향, 조명 등의 무인감시설비의 주요 장비의 작동 상태에 관한 정보를 수신하고 판단하는 통합형 네트워크 비디오 서버(NVR)와 무인감시설비의 상태를 감지하고 전원 복구하는 제어장치와 SMS 서버를 이용한 실시간 문자메시지로 구성되어 있다.

Reconstruction of Pharyngolaryngeal Defects with the Ileocolon Free Flap: A Comprehensive Review and How to Optimize Outcomes

  • Escandon, Joseph M.;Santamaria, Eric;Prieto, Peter A.;Duarte-Bateman, Daniela;Ciudad, Pedro;Pencek, Megan;Langstein, Howard N.;Chen, Hung-Chi;Manrique, Oscar J.
    • Archives of Plastic Surgery
    • /
    • 제49권3호
    • /
    • pp.378-396
    • /
    • 2022
  • Several reconstructive methods have been reported to restore the continuity of the aerodigestive tract following resection of pharyngeal and hypopharyngeal cancers. However, high complication rates have been reported after voice prosthesis insertion. In this setting, the ileocolon free flap (ICFF) offers a tubularized flap for reconstruction of the hypopharynx while providing a natural phonation tube. Herein, we systematically reviewed the current evidence on the use of the ICFF for reconstruction of the aerodigestive tract. A systematic literature search was conducted across PubMed MEDLINE, Web of Science, ScienceDirect, Scopus, and Ovid MEDLINE(R). Data on the technical considerations and surgical and functional outcomes were extracted. Twenty-one studies were included. The mean age and follow-up were 54.65 years and 24.72 months, respectively. An isoperistaltic or antiperistaltic standard ICFF, patch flap, or chimeric seromuscular-ICFF can be used depending on the patients' needs. The seromuscular chimeric flap is useful to augment the closure of the distal anastomotic site. The maximum phonation time, frequency, and sound pressure level (dB) were higher with ileal segments of 7 to 15 cm. The incidence of postoperative leakage ranged from 0 to 13.3%, and the majority was occurring at the coloesophageal junction. The revision rate of the microanastomosis ranged from 0 to 16.6%. The ICFF provides a reliable and versatile alternative for reconstruction of middle-size defects of the aerodigestive tract. Its three-dimensional configuration and functional anatomy encourage early speech and deglutition without a prosthetic valve and minimal donor-site morbidity.

지능형 전원제어장치를 이용한 자동화 유지보수 무인감시시스템 (Automated Maintenance Unmanned Monitoring System Using Intelligent Power Control System)

  • 채민욱;이충호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.237-239
    • /
    • 2021
  • 무인 감시설비의 고장과 오작동으로 인해 담당자가 무인 감시시설에 도착할 때까지 생기는 시간 지연과 침입자의 침입으로 인한 시설물 절도, 파손 그리고 정보유출 피해가 발생할 수 있다. 또한, 장비 고장과 오작동으로 인해 관리자의 상시점검으로 인한 추가비용이 발생한다. 본 논문에서는 무인 감시설비 오작동을 보완하기 위해 실시간으로 감시설비를 진단하여 문제 발생에 관한 내용을 표시하고 자동으로 설비 전원을 복구하며 담당자에게 문자메시지로 상황을 알리는 시스템을 제안한다. 제안한 시스템은 영상장치(CCTV), 음향장비, 투광등 장치 등의 무인 감시설비 주요 시설물로 이루어진 감시설비, 이 감시설비 정보를 판단할 수 있는 통합형 네트워크 비디오 레코더 장치(NVR), 전원을 제어하는 장치, 그리고 실시간으로 문자메시지를 보낼 수 있는 SMS 서버로 구성되어있다. 실험을 통하여 제안된 시스템의 유효성을 검증하였다.

  • PDF

이산화탄소 저장부지 위해성 관리를 위한 가상물리시스템 적용성 평가 (Application of Cyber Physical System (CPS) for Risk Management of a CO2 Storage Site)

  • 정진아;박은규;전성천;김현준;윤성택
    • 자원환경지질
    • /
    • 제50권5호
    • /
    • pp.363-373
    • /
    • 2017
  • 본 연구에서는 이산화탄소 지중저장 부지관리를 위한 가상물리시스템(Cyber Physical System, CPS)의 적용성을 검토하였다. 특히, 이산화탄소 누출 예측을 위한 가상트윈으로써 서배깅 회귀분석 기법을 활용하였고, 실제 모니터링 자료를 이용하여 해당기법의 성능을 검증하였다. 검증 결과, 서배깅 회귀분석 기법이 자료 내 이상치에 대하여 견고한 추세 예측성능을 보여주었으며 장기 농도변화 예측성능 또한 우수함을 확인하였다. 또한 적은 연산자원을 활용하여 즉시적인 예측결과를 도출함에 따라 이산화탄소 누출 실시간 예측 및 위험 경보에도 적합함을 알 수 있었다. 이러한 결과들은 서배깅 회귀분석 기법을 가상트윈으로 활용하는 CPS가 이산화탄소 누출 위험을 효율적으로 관리하는데 활용 될 수 있음을 보여준다.

Low-viscosity Resin Sysem이 복합레진 수복물의 변연누출에 미치는 영향 (THE EFFECT OF LOW-VISCOSITY RESIN SYSTEMS OM MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATIONS)

  • 양정숙;김문현;허선;김재곤;백병주
    • 대한소아치과학회지
    • /
    • 제24권2호
    • /
    • pp.460-474
    • /
    • 1997
  • The purpose of this study was to evaluate and compare the effectiveness of various low-viscosity resin systems used as rebonding agents to prevent microleakage at the margins of class I composite resin restorations. Seventy sound human premolars were selected for experiment. Class I cavities were prepared and each cavity was conditioned with a 37% phosphoric acid for 15 sec, rinsed with water for 15 sec, and dried with compressed air. Bonding agent(Scotchbond Multipurpose, 3M Co.) was applied and a hybrid composite resin (Z-100, 3M Co.) was placed using an incremental technic. The excess cured composite resin was carefully removed with Sof-Lex discs(3M Co.) to expose the original margins of the cavity. The following seven groups were established : group 1 was not rebonded and used as control group ; group 2 was rebonded with a Scotchbond Multipurpose(3M Co.) and finished ; group 3 was rebonded with a Fortify(BISCO) and finished ; group 4 was rebonded with a Concise white sealant(3M Co.) and finished ; group 5 was rebonded with a Concise white sealant(3M Co.) and not finished ; group 6 was rebonded with a P&F sealant(BISCO) and finished; group 7 was rebonded with a P&F sealant(BISCO) and not finished. The specimens were then subjected to 500 thermocycles between 5 & 65 with a 10 see dwell time and immersed in 2% methylene blue dye solution for 24 hours and sectioned with low-speed diamond cutter into two part under water condition. The extent of microleakage at rebonded margins was evaluated microscopically and scored for dye penetration according to the following scale : 0=no dye penetration ; 1=dye penetration to half-way along axial wall between enamel surface and DEJ ; 2=dye penetration beyond halfway along axial wall between enamel surface and DEJ ; 3=dye penetration to the full depth of DEJ or beyond DEJ. Selected samples were prepared for SEM observation to determine the depth of penetration of the rebonding agent into the marginal interface. The obtained results were as follows: 1. In the group 2 and 3, which is rebonded with a Scotchbond Multipupose and Fortify, dye penetration score were decreased significantly than that of group 1 (P<0.05), but group 4 and 6 were not statistically different from group 1(P>0.05). 2. There were significant differences between group 4, 6 and group 5, 7 when compared by dye penetration score (P<0.05). 3. In the SEM observation, Scotchbond Multipurpose and Fortify were penetrated within $30-40{\mu}m$ depth of the outermost surface. However, both sealants were failed to penetrate into the debonded interface.

  • PDF

복합레진 수복물의 미세누출 감소를 위한 레진 전색제의 효과 (EFFECT OF RESIN SEALANTS ON THE REDUCTION OF MICROLEAKAGE IN COMPOSITE RESTORATIONS)

  • 조영곤;김문홍;이명구
    • Restorative Dentistry and Endodontics
    • /
    • 제31권4호
    • /
    • pp.282-289
    • /
    • 2006
  • 본 연구의 목적은 5급 복합레진 수복물에 각종 레진 전색제를 적용한 후, 수복물의 교합면측과 치은측 변연 미세누출에 대한 레진 전색제의 감소효과를 평가하기 위하여 시행하였다. 40개의 발거된 대구치의 협면 치경부에 5급 와동을 형성하고 복합레진을 충전한 후, 사용된 레진 전색제에 따라 다음 과 같이 4개의 군으로 분류하였다; 복합레진 표면과 변연부에 레진 전색제를 적용하지 않은 대조군, 복합레진 표면과 변연부에 각각 레진 전색제를 적용한 Fortify Plus 군, BisCover 군 및 PermaSeal 군으로 분류하였다. 각 군의 시편을 실온의 증류수에 24시간 동안 보관한 후, $5^{\circ}C$$55^{\circ}C$에서 1,000회의 열 순환을 시행하고 2% methylene blue 용액에 4시간동안 침적시켰다. 각 치아는 저속의 diamond disk 를 이용하여 각 수복물의 중앙부를 따라 협, 설 방향으로 양분 하고 20배율의 광학 입체현미경 하에서 각각 교합면측과 치은측 변연 미세누출을 평가하였다. 각 군의 교합면측과 치은측 변연 미세누출에 대한 유의성을 검정을 시행하여 다음과 같은 결과를 얻었다. 1. 교합면측 변연 미세누출은 사용된 레진 전색제 간에 통계학적으로 유의한 차이를 나타내지 않았다. 2. 치은측 변연 미세누출은 대조군과 Fortify Plus 군이 PermaSeal 군보다 통계학적으로 높게 나타났으며, 또한 Fortify Plus 군은 Biscover 군보다 통계학적으로 높은 변연 미세누출을 나타내었다 (p < 0.05). 3. 대조군과 Fortify Plus 군은 교합면측 보다 치은측 변연에서 통계학적으로 더 높은 미세누출을 나타내었다 (p < 0.05). 4. BisCover 군과 PermaSeal 군은 교합면측과 치은측의 변연 미세누출 간에 통계학적으로 유의한 차이를 나타내지 않았다. 본 연구를 종합하면, 5급 복합레진 수복물의 교합면측 변연 미세누출에 대한 레진 전색제의 감소효과는 크게 나타나지 않았지만, 치은측 변연 미세누출에 대한 레진 전색제의 감소효과는 사용된 레진 전색제에 따라 서로 다르게 나타났다.