15년 경과한 PC아파트의 누수경로 조사결과 (Path of Water Leakage of PC Apartment House 15 Years Have Elapsed)

  • 이정훈;배기선;김상연;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.156-157
    • /
    • 2014
  • PC apartment house 15 years have elapsed have various deteriorations by water leakage in roof and wall. The prior investigation such as investigating of leakage repair history of PC apartment and the field investigation were carried out to solve the water leak problem in its structure. The path of water was analyzed on the parts of greatest water leak such as roof parapet, roof floor, side wall, corridor and balcony. As a result, the specific path of the water leakage was identified in various structure units.

  • PDF

변형 Martius 구해면체 지방피판술을 이용한 신생방광-질루의 치험례 (Neobladder-vaginal Fistula Repair with Modified Martius Bulbocavernosus Fat Pad Flap)

  • 명유진;박지웅;정의철;김석화
    • Archives of Plastic Surgery
    • /
    • 제38권3호
    • /
    • pp.329-332
    • /
    • 2011
  • Purpose: In developed countries, vesicovaginal fistula occur from various pelvic operations including total hysterectomy, leading to urinary leakage and incontinence. Although various methods have been proposed for adequate tissue coverage in fistula repair, the surgical treatment of is not simple and still controversial. We report a case of neobladder-vaginal fistula repair using modified Martius fat pad flap. Methods: A 62-year-old female patient underwent radical cystectomy with total abdominal hysterectomy and neobladder formation due to invasive bladder tumor 5 years ago. For 3 years following the operation, urine leakage was observed. Exploration demonstrated neobladder-vaginal fistula and primary repair including fistulectomy and direct closure was performed. Urinary incontinence relapsed 2 years after primary repair, and after demonstrating the recurrence of fistula on urography, repair of recurrent fistula was performed. After dissection of vagina and neobladder and closure of fistula by urologic surgeon, fibroadipose flap was elevated, rotated and advanced through the tunnel at vaginal sidewall, and interpositioned to the fistula site between neobladder and vagina. Results: There was no acute complication after the surgery and urethral catheter was extracted on the 8th day after the operation. During six month follow-up period after the operation, there is no clinical evidence of fistula recurrence. Conclusion: From our clinical experience and literature review, we think Martius fat pad flap is a useful technique in management of neobladder-vaginal fistula, for it provides enough vascularity, major epithelization surface and better lymphatic drainage, and also prevents overlapping of vesical, vaginal suture lines at the same time.

반주기 변조된 송신파형과 대지전위 측정을 이용한 지중 케이블 누전 고장점 탐지 시스템 (Electric Leakage Point Detection System of Underground Power Cable Using Half-period Modulated Transmission Waveform and Earth Electric Potential Measurement)

  • 전정채;유재근
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2113-2118
    • /
    • 2016
  • The precise detection of electric leakage point of underground power cable is very important to reduce cost and time of maintenance and prevent electric shock accident through expedite repair of electric leakage point. This paper proposes a electric leakage point detection system underground power cable using of half-period modulated transmission waveform and earth electric potential measurement. The developed system is composed of transmitter to generate the wanted pulse waveform, receiver to measure and display earth electric potential by the transmitted pulse in electric leakage point and PC Software program to display of GPS coordinate on detection cable line. The performance of the electric leakage point detection system was tested in the constructed underground cable leakage detection test bed. The test results on signal generation voltage precision of signal transmitter, mean detection earth voltage, mean detection leakage current and electric leakage point detection error showed the developed system can be used in electric leakage point detection underground power cable.

Multi-Layer Onlay Graft Using Hydroxyapatite Cement Placement without Cerebrospinal Fluid Diversion for Endoscopic Skull Base Reconstruction

  • Kim, Young-Hoon;Kang, Ho;Dho, Yun-Sik;Hwang, Kihwan;Joo, Jin-Deok;Kim, Yong Hwy
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권4호
    • /
    • pp.619-630
    • /
    • 2021
  • Objective : The skull base reconstruction step, which prevents cerebrospinal fluid (CSF) leakage, is one of the most challenging steps in endoscopic skull base surgery (ESS). The purpose of this study was to assess the outcomes and complications of a reconstruction technique for immediate CSF leakage repair using multiple onlay grafts following ESS. Methods : A total of 230 consecutive patients who underwent skull base reconstruction using multiple onlay grafts with fibrin sealant patch (FSP), hydroxyapatite cement (HAC), and pedicled nasoseptal flap (PNF) for high-flow CSF leakage following ESS at three institutions were enrolled. We retrospectively reviewed the medical and radiological records to analyze the preoperative features and postoperative results. Results : The diagnoses included craniopharyngioma (46.8%), meningioma (34.0%), pituitary adenoma (5.3%), chordoma (1.6%), Rathke's cleft cyst (1.1%) and others (n=21, 11.2%). The trans-planum/tuberculum approach (94.3%) was the most commonly adapted surgical method, followed by the trans-sellar and transclival approaches. The third ventricle was opened in 78 patients (41.5%). Lumbar CSF drainage was not performed postoperatively in any of the patients. Postoperative CSF leakage occurred in four patients (1.7%) due to technical mistakes and were repaired with the same technique. However, postoperative meningitis occurred in 13.5% (n=31) of the patients, but no microorganisms were identified. The median latency to the diagnosis of meningitis was 8 days (range, 2-38). CSF leakage was the unique risk factor for postoperative meningitis (p<0.001). Conclusion : The use of multiple onlay grafts with FSP, HAC, and PNF is a reliable reconstruction technique that provides immediate and complete CSF leakage repair and mucosal grafting on the skull base without the need to harvest autologous tissue or perform postoperative CSF diversion. However, postoperative meningitis should be monitored carefully.

배급수관망에서의 누수복원량 산정방법 (Estimation method of natural rate of rise of leakage in water distribution system)

  • 진샘물;김경필;구자용
    • 상하수도학회지
    • /
    • 제33권4호
    • /
    • pp.299-309
    • /
    • 2019
  • Waterworks facilities inevitably experience some amount of leakage even if there is a lot of investment or state-of-the-art technology that is applied such as DMA(District Metered Area) system construction, leakage detection, repair, pipe rehabilitation, etc. The primary reason is the leakage is naturally restored over time. In the UK, this restoration characteristic is defined as NRR(Natural rate of rise of leakage) and used to decision making for prioritizing active leakage control of DMAs. However, this restoration characteristic is well recognized, but researches on NRR in the water distribution system are insufficient in Korea. In this study, the estimation method of NRR was developed suitable for applicating in Korea considering of SCADA data, water infrastructure, and water usage patterns by modification of the UK's NRR method. The proposed method was applied to 9 DMAs and verified it's applicability by comparing with the other water loss performance indicators. It is expected that the proposed method can be used to support decision making for sustainable NRW(Nor-revenue water) management in the water distribution system.

Development of the Activity Type Smart Concrete using the Glass Pipe

  • Kim, Ie-Sung;Kim, Wha-Jung
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.29-32
    • /
    • 2005
  • A various structural materials are used in construction projects such as a stone, concrete, steel materials. Between of them, concrete are used widely. The compressive strength of concrete is high, and its maintenance and management is comparatively easy. The R.C Building will be superannuated as time passes. This program is generated by propagation of cracks. In order to manage such cracks, time and efforts, expense, etc. are required. In this study, glass sensors were embedding in a model beam and column and leakage of fluorescence and adhesive material was investigated. Further, currents in glass pipe were observed to find the leakage of liquid in glass pipes. Progressive cracks generated by cause the fracture of glass pipes. Therefore, the liquid become to flow and electric current stops, and the cracked part of the member can be found easily. Moreover, the adhesive delays progressive cracking system that responds in air, and the life of a structure can be made to extend. The purpose of this research is to develop of low price sensors that can perform of self-diagnosis in addition to ability of concrete repair concrete to damage.

식도 재건 수술후 발생한 합병증 치험 (Treatment of the complications of the esophageal reconstructive procedures)

  • 이두연;윤치순;홍승록
    • Journal of Chest Surgery
    • /
    • 제24권5호
    • /
    • pp.463-469
    • /
    • 1991
  • Post-anastomotic leakage and stenoses remain major complications and are still responsible for many mortalities after esophageal reconstructive procedures. If the hand-suture is used, anastomotic leaks developed frequently than stenoses. But post-anastomotic leakages are more critical than post-anastomotic stenoses. If the stapler is used, anastomotic stenoses will develop frequently and not critical than anastomotic leakages. The stapler suture method is easier and quicker than the hand suture method in the esophageal anastomotic procedures. But the disadvantages of the stapler suture method is that there is not reachable site with anastomotic stapler the thoracic inlet region and the cost is expensive. We have treated 44 cases of the surgical complications after esophageal reconstructive procedure with conservative and surgical treatment for 10 years from January, 1980 to December, 1989. The anastomotic site stenoses were 8 cases in the hand-suture methods and 4 cases in the stapler-suture methods. The anastomotic leaks were 8 cases in hand-suture methods and 5 cases in stapler-suture methods. There were one death in the surgical repair of four post-operative anastomotic stenoses and two deaths in the surgical repair of three post-operative anastomotic leakages. Ever though we consider that there is more anastomotic leakage than stenoses after the hand-suture methods in esophageal reconstructive procedures. the cost with long stay in the intensive care unit to treat anastomotic leakage after the hand-suture, would be more expensive than-the cost of the treatment of the anastomotic stenoses after auto-suture.

  • PDF

Modified Graded Repair of Cerebrospinal Fluid Leaks in Endoscopic Endonasal Transsphenoidal Surgery

  • Park, Jae-Hyun;Choi, Jai Ho;Kim, Young-Il;Kim, Sung Won;Hong, Yong-Kil
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권1호
    • /
    • pp.36-42
    • /
    • 2015
  • Objective : Complete sellar floor reconstruction is critical to avoid postoperative cerebrospinal fluid (CSF) leakage during transsphenoidal surgery. Recently, the pedicled nasoseptal flap has undergone many modifications and eventually proved to be valuable and efficient. However, using these nasoseptal flaps in all patients who undergo transsphenoidal surgery, including those who had none or only minor CSF leakage, appears to be overly invasive and time-consuming. Methods : Patients undergoing endoscopic endonasal transsphenoidal tumor surgery within a 5 year-period were reviewed. Since 2009, we classified the intraoperative CSF leakage into grades from 0 to 3. Sellar floor reconstruction was tailored to each leak grade. We did not use any tissue grafts such as abdominal fat and did not include any procedures of CSF diversions such as lumbar drainage. Results : Among 200 cases in 188 patients (147 pituitary adenoma and 41 other pathologies), intraoperative CSF leakage was observed in 27.4% of 197 cases : 14.7% Grade 1, 4.6% Grade 2a, 3.0% Grade 2b, and 5.1% Grade 3. Postoperative CSF leakage was observed in none of the cases. Septal bone buttress was used for Grade 1 to 3 leakages instead of any other foreign materials. Pedicled nasoseptal flap was used for Grades 2b and 3 leakages. Unused septal bones and nasoseptal flaps were repositioned. Conclusion : Modified classification of intraoperative CSF leaks and tailored repair technique in a multilayered fashion using an en-bloc harvested septal bone and vascularized nasoseptal flaps is an effective and reliable method for the prevention of postoperative CSF leaks.

A method to prevent cerebrospinal fluid leakage: Reinforcing acellular dermal matrix

  • Lee, Hojune;Eom, Ye Seul;Pyon, Jai-Kyong
    • 대한두개안면성형외과학회지
    • /
    • 제21권1호
    • /
    • pp.45-48
    • /
    • 2020
  • In neurosurgical cases, problems related to wound healing can vary from simple wound dehiscence to multilayer defects. This study demonstrates an effective method to prevent persistent cerebrospinal fluid (CSF) leakage using reinforcing acellular dermal matrix in neurosurgical patients with wound dehiscence. A 52-year-old woman was admitted for management of recurrent glioblastoma. After tumor removal surgery, the patient experienced sustained CSF leakage from the wound despite reparative attempts. The plastic surgery team performed wound repair procedure after remnant tumor removal by the neurosurgery team. Acellular dermal matrix was applied over the mesh plate to prevent CSF leakage and the postoperative status of the patient was evaluated. No sign of CSF leakage was found in the immediate postoperative period. After 3 years, there were no complications including CSF leakage, wound dehiscence, and infection. We hereby propose this method as a feasible therapeutic alternative for preventing CSF leakage in patients experiencing wound problem after neurosurgical procedures.

2액형 점착 실링재의 누수보수재 평가에 관한 연구 (2 Component Adhesive Leakage Repair Sealant Evaluation)

  • 조일규;김근허;오상근
    • 한국건설순환자원학회논문집
    • /
    • 제4권4호
    • /
    • pp.396-403
    • /
    • 2016
  • 본 연구에서는 지하 콘크리트 구조물에 누수 발생 시 콘크리트 배면에 주입하여 보수를 시행하는 1액형 점착 실링재에 대해 알아보고 새로운 콘크리트 배면 주입재인 2액형 점착 실링재에 대한 평가를 진행하였다. 2액형 점착 실링재는 아스팔트 계열의 주제와 라텍스 계열의 증점제로 구성된 실링재이며, 주제와 증점제의 배합비에 따라 실링재의 점도편차가 크게 나타났다. 이에 주제와 증점제의 배합비를 투수시험을 통해 확인한 결과 주입성, 경제성, 성능을 고려하여 적정배합비를 6:1로 정하고 KS F 4935 평가를 진행하였다. 2액형 점착 실링재는 static mixer를 활용한 카트리지 타입의 용기를 이용하여 주입이 가능하고 KS F 4935 시험방법에 따라 평가를 진행한 결과 KS 기준을 만족하였다.