• Title/Summary/Keyword: leakage rate

검색결과 929건 처리시간 0.031초

Field Sanitation and Foliar Application of Streptomyces padanus PMS-702 for the Control of Rice Sheath Blight

  • Yang, Chia-Jung;Huang, Tzu-Pi;Huang, Jenn-Wen
    • The Plant Pathology Journal
    • /
    • 제37권1호
    • /
    • pp.57-71
    • /
    • 2021
  • Rice sheath blight (ShB), caused by Rhizoctonia solani Kühn AG1-IA, is one of the destructive rice diseases worldwide. The aims of this study were to develop biocontrol strategies focusing on field sanitation and foliar application with a biocontrol agent for ShB management. Streptomyces padanus PMS-702 showed a great antagonistic activity against R. solani. Fungichromin produced by S. padanus PMS-702, at 3.07 mg/l inhibited 50% mycelial growth, caused leakage of cytoplasm, and inhibited the formation of infection structures of R. solani. Fungichromin could reach to 802 mg/l when S. padanus PMS-702 was cultured in MACC broth for 6 days. Addition of 0.5% S. padanus PMS-702 broth into soil decreased the survival rate of the pathogen compared to the control. Soil amended with 0.5% S. padanus broth and 0.5% tea seed pomace resulted in the death of R. solani mycelia in the infested rice straws, and the germination of sclerotia was inhibited 21 days after treatment. Greenhouse trials revealed that S. padanus cultured in soybean meal-glucose (SMGC-2) medium after mixing with different surfactants could enhance its efficacy for inhibiting the pathogen. Of six surfactants tested, the addition of 2% tea saponin was the most effective in suppressing the pathogen. S. padanus broth after being fermented in SMGC-2, mixed with 2% tea saponin, diluted 100 fold, and sprayed onto rice plants significantly reduced ShB disease severity. Thus, S. padanus PMS-702 is an effective biocontrol agent. The efficacy of S. padanus PMS-702 for disease control could be improved through formulation.

Impact of Esophagojejunal Reconstruction without Division of the Mesentery for Total Laparoscopic Total Gastrectomy

  • Ko, Chang Seok;Jheong, Jin Ho;Lee, In-Seob;Kim, Beom Su;Kim, Min-Ju;Yoo, Moon-Won
    • Journal of Gastric Cancer
    • /
    • 제21권1호
    • /
    • pp.63-73
    • /
    • 2021
  • Purpose: This study aimed to compare the surgical outcomes of total laparoscopic total gastrectomy without mesentery division (LTG without MD) and conventional total laparoscopic total gastrectomy (CLTG), as well as evaluate the appropriate method for esophagojejunostomy (EJ) reconstruction after total laparoscopic total gastrectomy (TLTG). Materials and Methods: We retrospectively analyzed data from 301 consecutive patients who underwent TLTG for upper or middle third gastric cancer between January 2016 and May 2019. After propensity score matching, 95 patients who underwent LTG without MD and 95 who underwent CLTG were assessed. Data on clinical characteristics and surgical outcomes, including operation time, length of postoperative hospital stay, pathological findings, and postoperative complications were analyzed. Results: The LTG without MD group showed a shorter time to first flatus (3.26±0.80 vs. 3.62±0.81 days, P=0.003) and a shorter time to soft diet (2.80±2.09 vs. 3.52±2.20 days, P=0.002). The total EJ-related complications in the LTG without MD group were comparable to those in the CLTG group (9.47% vs. 3.16%, P=0.083). EJ-related leakage (6.32% vs. 3.16%, P=0.317) and EJ-related stricture (3.16% vs. 1.05%, P=0.317) rates were not significantly different between the LTG without MD and CLTG groups. No significant differences were found between the two groups in terms of other early surgical outcomes such as early complications, late complications, hospital stay, and readmission rate. Conclusions: LTG without MD is a safe surgical treatment for upper or middle third gastric cancer. LTG without MD may be an alternative procedure for EJ anastomosis during TLTG.

C-arm CT의 필수 성능평가 기준 마련을 위한 연구 (A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

합성폴리머 실라카졸 그라우트의 공학적 특성 평가 (Evaluation of Engineering Properties in Synthetic Polymer-Silica Sol Grout)

  • 장성민;정혁상;김정한;민병찬;이병석
    • 한국지반신소재학회논문집
    • /
    • 제21권3호
    • /
    • pp.29-39
    • /
    • 2022
  • 본 연구에서는 용탈 저감 효과가 있는 합성폴리머 실리카졸의 그라우트 성능을 평가하고, 기존 물유리계 SGR 주입재와 비교한 내용을 다루었다. 강도 및 내구성에 대한 실내실험 결과 합성폴리머 실리카졸는 물유리계 주입재 대비 2배 이상 높은 일축압축강도, 수축률 및 투수성에서 현저히 낮은 값을 보여주었고, pH는 먹는 물 수질기준인 8.5 이하였다. 용탈시험결과 합성폴리머 실리카졸의 Na2O 용출량은 물유리계 주입재 대비 3~4배 작게 측정되었다. 이러한 결과로 보아 합성폴리머 실리카졸은 기존 물유리계 주입재보다 더 우수한 내구성 및 차수성을 가지는 것으로 판단된다.

An approach to minimize reactivity penalty of Gd2O3 burnable absorber at the early stage of fuel burnup in Pressurized Water Reactor

  • Nabila, Umme Mahbuba;Sahadath, Md. Hossain;Hossain, Md. Towhid;Reza, Farshid
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3516-3525
    • /
    • 2022
  • The high capture cross-section (𝜎c) of Gadolinium (Gd-155 and Gd-157) causes reactivity penalty and swing at the initial stage of fuel burnup in Pressurized Water Reactor (PWR). The present study is concerned with the feasibility of the combination of mixed burnable poison with both low and high 𝜎c as an approach to minimize these effects. Two considered reference designs are fuel assemblies with 24 IBA rods of Gd2O3 and Er2O3 respectively. Models comprise nuclear fuel with a homogeneous mixture of Er2O3, AmO2, SmO2, and HfO2 with Gd2O3 as well as the coating of PaO2 and ZrB2 on the Gd2O3 pellet's outer surface. The infinite multiplication factor was determined and reactivity was calculated considering 3% neutron leakage rate. All models except Er2O3 and SmO2 showed expected results namely higher values of these parameters than the reference design of Gd2O3 at the early burnup period. The highest value was found for the model of PaO2 and Gd2O3 followed by ZrB2 and HfO2. The cycle burnup, discharge burnup, and cycle length for three batch refueling were calculated using Linear Reactivity Model (LRM). The pin power distribution, energy-dependent neutron flux and Fuel Temperature Coefficient (FTC) were also studied. An optimization of model 1 was carried out to investigate effects of different isotopic compositions of Gd2O3 and absorber coating thickness.

Optimization of target, moderator, and collimator in the accelerator-based boron neutron capture therapy system: A Monte Carlo study

  • Cheon, Bo-Wi;Yoo, Dohyeon;Park, Hyojun;Lee, Hyun Cheol;Shin, Wook-Geun;Choi, Hyun Joon;Hong, Bong Hwan;Chung, Heejun;Min, Chul Hee
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1970-1978
    • /
    • 2021
  • The aim of this study was to optimize the target, moderator, and collimator (TMC) in a neutron beam generator for the accelerator-based BNCT (A-BNCT) system. The optimization employed the Monte Carlo Neutron and Photon (MCNP) simulation. The optimal geometry for the target was decided as the one with the highest neutron flux among nominates, which were called as angled, rib, and tube in this study. The moderator was optimized in terms of consisting material to produce appropriate neutron energy distribution for the treatment. The optimization of the collimator, which wrapped around the target, was carried out by deciding the material to effectively prevent the leakage radiations. As results, characteristic of the neutron beam from the optimized TMC was compared to the recommendation by the International Atomic Energy Agent (IAEA). The tube type target showed the highest neutron flux among nominates. The optimal material for the moderator and collimator were combination of Fluental (Al203+AlF3) with 60Ni filter and lead, respectively. The optimized TMC satisfied the IAEA recommendations such as the minimum production rate of epithermal neutrons from thermal neutrons: that was 2.5 times higher. The results can be used as source terms for shielding designs of treatment rooms.

수전해설비의 전기방폭 기준 만족을 위한 비방폭화 방안에 관한 연구 (A Study on the Non-Hazardous Method for complying with the Explosion Proof Criteria of the Electrolysis)

  • 김용규;한신탁;박종범;공병찬;박계준;정승호
    • 한국가스학회지
    • /
    • 제26권6호
    • /
    • pp.65-75
    • /
    • 2022
  • 최근 수전해설비의 운전압력이 증가함에 따라 수소 누출로 인한 화재 및 폭발 가능성 및 위험성 또한 증가하고 있다. 따라서 관계법령 및 기술기준에 따라 수전해 시스템에 설치되는 모든 전기기에 전기방폭 형식인증 제품을 사용하거나 적절한 방법에 따른 비폭발위험장소화 절차를 적용해야 한다. 본 연구에서는 수전해설비의 일반적인 운전조건을 고려하여 KS C IEC 60079-10-1 및 KGS GC101에 따른 폭발위험장소 구분 및 범위 산정을 수행하였다. 또한, 비폭발위험장소화를 달성하기 위해 임계농도인 폭발하한 25 % 미만의 농도를 유지하기 위한 적정 환기량을 검토하였다. 그 결과 자연환기만 적용할 경우에는 수전해설비가 폭발위험장소로 구분되고, 이를 강제환기를 통해 비폭발위험장소로 구분하기 위해서는 막대한 환기량이 필요함을 확인할 수 있었다.

Reconstruction of Pharyngolaryngeal Defects with the Ileocolon Free Flap: A Comprehensive Review and How to Optimize Outcomes

  • Escandon, Joseph M.;Santamaria, Eric;Prieto, Peter A.;Duarte-Bateman, Daniela;Ciudad, Pedro;Pencek, Megan;Langstein, Howard N.;Chen, Hung-Chi;Manrique, Oscar J.
    • Archives of Plastic Surgery
    • /
    • 제49권3호
    • /
    • pp.378-396
    • /
    • 2022
  • Several reconstructive methods have been reported to restore the continuity of the aerodigestive tract following resection of pharyngeal and hypopharyngeal cancers. However, high complication rates have been reported after voice prosthesis insertion. In this setting, the ileocolon free flap (ICFF) offers a tubularized flap for reconstruction of the hypopharynx while providing a natural phonation tube. Herein, we systematically reviewed the current evidence on the use of the ICFF for reconstruction of the aerodigestive tract. A systematic literature search was conducted across PubMed MEDLINE, Web of Science, ScienceDirect, Scopus, and Ovid MEDLINE(R). Data on the technical considerations and surgical and functional outcomes were extracted. Twenty-one studies were included. The mean age and follow-up were 54.65 years and 24.72 months, respectively. An isoperistaltic or antiperistaltic standard ICFF, patch flap, or chimeric seromuscular-ICFF can be used depending on the patients' needs. The seromuscular chimeric flap is useful to augment the closure of the distal anastomotic site. The maximum phonation time, frequency, and sound pressure level (dB) were higher with ileal segments of 7 to 15 cm. The incidence of postoperative leakage ranged from 0 to 13.3%, and the majority was occurring at the coloesophageal junction. The revision rate of the microanastomosis ranged from 0 to 16.6%. The ICFF provides a reliable and versatile alternative for reconstruction of middle-size defects of the aerodigestive tract. Its three-dimensional configuration and functional anatomy encourage early speech and deglutition without a prosthetic valve and minimal donor-site morbidity.

유도전동기의 구속운전에 따른 전기 및 발열 특성 연구 (A Study on the Electrical and Heat Generation Characteristics of an Induction Motor under Restrained Operation)

  • 이종찬;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권1호
    • /
    • pp.25-33
    • /
    • 2023
  • In this study, we determined the failure rate and fire status of electric motors widely used in domestic and industrial devices and analyzed the associated fire risks by identifying the electrical and temperature characteristics of electric motors under the normal and restrained operation modes in industrial sites and laboratories. A 2.2kW motor used for driving a conveyor during the vulcanization process in a rubber product manufacturing plant was employed as the study object and was exposed to a high- temperature environment as this motor is widely used in industrial sites. The current amplitude was 4.45-4.50 A during normal operation and 38.2-41.5 A during restrained operation due to the pinching of products and semi-finished products (i.e., 8.5 times higher than that during normal operation). The leakage current amplitude was 0.33 mA during both operation modes. The temperature of the workplace in summer was 42.38℃, indicating a poor environment for the installed motor. In the laboratory, the current and temperature of the coil inside a 3.7kW motor were measured under the restrained operation mode as performing measurements of the coil inside the motor in industrial sites is challenging. The current amplitude during normal operation was 3.5 A, whereas that during restrained operation for 30 s was 51.7-58.6 A, which is 14.8-16.7 times higher than that of normal operation. Moreover, the temperature of the motor coil increased from 22.9℃ to 101℃. Based on the experimental data, we derived the temperature increase formula according to the restrained operation time by performing a regression analysis and verified the time at which the temperature exceeded the stipulated limit for the insulation grade. The findings presented in this paper can be utilized to establish fire-prevention measures and perform safety management of motors of the same type or with a similar capacity.

사보타주 공격으로 인한 사용후핵연료 운반용기 격납 실패시 핵연료 손상에 따른 방사선 영향 평가 (Evaluation of Radiation Effect on Damage to Nuclear Fuel of Spent Fuel Transport CASK due to Sabotage Attack)

  • 박기호;김종성;차건일;박창제
    • 한국압력기기공학회 논문집
    • /
    • 제18권2호
    • /
    • pp.43-49
    • /
    • 2022
  • The purpose of this study is to evaluate the radiation effect on damage when the external shield of the spent nuclear fuel transport cask is damaged due to impact as the cause of an unexpected accident. The neutron and gamma-ray intensities and spectra are calculated using the ORIGEN-Arp module in the SCALE 6.2.4 code package(1) and then using MCNP6.2(2) code calculate the dose rate. In order to evaluate the radiation dose according to the size of damage caused by external impact, various sized holes of 0.3~13.7% are assumed in the outer shield of the cask to evaluate the sensitivity to the dose. In the case of radiation source leakage, damage to the nuclear fuel assembly is assumed to be up to 6% based on overseas test cases. When only the outer shield is damaged, the maximum surface dose is calculated as 3.12E+03 mSv/hr. However, if the radiation source is leaked due to damage to the nuclear fuel assembly, it becomes 7.00E+05 mSv/hr which is about 200 times greater than the former case.