• Title/Summary/Keyword: leakage power

Search Result 1,423, Processing Time 0.027 seconds

Temperature dependent characteristics of leakage currents of ZnO blocks (온도에 따른 ZnO 피뢰기 소자의 누설전류의 온도의존성)

  • Lee, Bok-Hee;Lee, Su-Bong;Li, Feng;Kim, Dong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1572-1573
    • /
    • 2006
  • This paper presents electrical properties of Zinc Oxide(ZnO) surge arrester blocks under the power frequency AC voltages and various temperatures. The leakage current, $I_{R}-V$ curios and power dissipation for the fine and aged ZnO surge arrester blocks were measured as a function of the temperatures and applied voltages. When the temperature is increased from $50\;[^{\circ}C]$ to $150\;[^{\circ}C]$, the total leakage current significantly increased at the sane applied voltage level. Also, the resistive leakage currents and power dissipation were increased with increasing temperature. The leakage current and power dissipation of the aged ZnO arrester blocks were higher than the fine ZnO arrester blocks.

  • PDF

A Study on the Fluid Leakage Evaluation for Power Plant Valve Using Acoustic Imaging Technique (음향 영상화기법을 이용한 발전용 밸브 유체누설평가 연구)

  • Lee, S G.;Lee, S.K.;Kim, D.W.
    • Journal of Power System Engineering
    • /
    • v.15 no.1
    • /
    • pp.18-23
    • /
    • 2011
  • Image processing has provided powerful techniques to extract from the acoustic signals the desired information on evaluation for leakage existence, leakage rate, and searching for leakage location, etc. The imagery NDE data available can add additional and significant dimension in nondestructive evaluation(NDE) information and thus for exploiting in applications. To extract such information the use of advanced image processing techniques is much needed. In recent years, there has been much increased use of acoustic signal image processing techniques in acoustic NDE. This approach will increase the efficiency of inspection procedures and reduce inspection time. In this paper we are concerned only with This paper is concerned mainly with the use of advanced image processing techniques in valve leakage detection and advanced image restoration and enhancement methods, which attempt to evaluate promptly by a visualization method the acoustic sources while detecting the valve leakage.

Client Collaboration for Power and Interference Reduction in Wireless Cellular Communication

  • Nam, Hyungju;Jung, Minchae;Hwang, Kyuho;Choi, Sooyong
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.1 no.2
    • /
    • pp.117-124
    • /
    • 2012
  • A client collaboration (CC) system is proposed for a user relay system. The proposed scheme focuses on the management of transmit power and leakage interference. In the proposed CC system, edge users transmit signals to the masters considered as user relays. The masters relay the signals of the edge users to the base station using the resource blocks (RBs) that are assigned to the edge users. The leakage interference and power consumption were analyzed in the CC system. In addition, an optimal master location problem was formulated based on the signal-to-leakage-plus-noise ratio (SLNR). Because the optimal master location problem is quite complex, a sub-optimal master location problem was proposed and a closed-form sub-optimal master location was obtained. The edge users generate smaller leakage interference and power consumption in the proposed CC system compared to the system without the CC. The numerical results showed that the edge users generate smaller leakage interference and power consumption in the proposed CC system compared to the system without the CC, and the average throughput increases.

  • PDF

Deterioration Diagnostic Techniques for Power Facilities by Analyzing Pulse-Height of leakage current (누설전류 파고분석에 의한 전력설비의 열화진단 기술)

  • 한주섭;김명진;손원진;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.367-370
    • /
    • 2001
  • This paper proposes a new deterioration diagnostic technique for power facilities by analyzing the pulse-height analysis of leakage current. Until now, various deterioration diagnostic techniques to prevent power system failures by deterioration of power facilities are suggested, and most of which measures leakage current amplitude only as a estimation parameter. In this experiment, it is known that the pulse heights of the leakage current are increased according to deterioration progress as well as there comes remarkable changes in pulse height distribution thereto. Therefore, the use of pulse height distribution in deterioration diagnostic technique makes more accurate diagnosis than the conventional method by using only leakage current value. From the application test, it is confirmed that the proposed technique has sufficient performance to diagnose deterioration of power facilities.

  • PDF

Development of Leakage Current Reduction Method in 3-Level Photovoltaic PCS (3레벨 태양광 PCS에서의 누설전류 저감기법 개발)

  • Han, Seongeun;Jo, Jongmin;An, Hyunsung;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.1
    • /
    • pp.56-61
    • /
    • 2019
  • In this study, a reduction method of leakage current in a three-level photovoltaic power-conditioning system (PCS) is proposed and verified by simulation and experiment. Leakage current generation is analyzed through an equivalent model of the common mode voltage considering a significant parasitic capacitance existing between the photovoltaic array and ground. A leakage current reduction method using pulse-width modulation (PWM) method is also proposed, and a 10-kW three-level photovoltaic PCS simulation and experiment is performed with a $1{\mu}F$ parasitic capacitor based on 100 nF/kW. The proposed method using the PWM method is verified to reduce the leakage current by 73% compared with the conventional PWM method.

An Development of Leakage Current Sensing Module of the System on Chip Type Under Consideration of Electromagnetic Interface in Power Trunk Line (전력간선에서의 전자파 장애를 고려한 원칩형 누설전류 원격 검출단말기의 개발)

  • Kim, Dong-Wan;Park, Ji-Ho;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.377-384
    • /
    • 2009
  • In this paper, leakage current sensing module of SoC(System on Chip)type and real time monitoring system under consideration of electromagnetic interface in power trunk line are developed. The first, leakage current sensing module of SoC type under consideration of electromagnetic interface is developed, and the developed sensing module of SoC type is composed of leakage sensing part, power supply part, interface part, communication part, AD(Alternating current to Direct current)convert part and amplification part. And also the electromagnetic compatibility is evaluated by conduction and radiation of EMI(Electromagnetic Interference) for developed sensing module. The developed system can have confidence, stability and do energy saving under mixed electric circumstance of the low voltage communication device and high voltage equipment. The second, the real time remote monitoring system is developed using designed wire and wireless communication module with leakage current sensing module of SoC type. The developed real time remote monitoring system can monitor sensing state, occurrence state of leakage current and alarm for each step etc.. And the device configuration, PCB layout for leakage current sensing module of system on chip type and the experiment configuration in consideration of EMI are presented. Also the measurement results of conduction and radiation for EMI are presented.

Influence of Harmonics in Power System Voltage on Arrester Deterioration Diagnostics by Leakage Current Measurement (누설전류측정에 의한 피뢰기 열화진단에 있어 전원고조파의 영향)

  • 길경석;한주섭;주문노
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.42-46
    • /
    • 2003
  • Arresters are deteriorated by overvoltages or impulse currents, and the resistive leakage current of arresters increases as the deterioration of the arrester progresses, showing an increase in the 3$^{rd}$ harmonic component of the leakage current. In this reason, arrester diagnostic techniques based on the 3$^{rd}$ harmonic leakage current as a reference parameter of deterioration are widely used. The technique, however, includes an error due to the harmonics of power system voltage. Therefore, the influence of the harmonics on arrester diagnostics should be considered. In this paper, we designed a PSpice ZnO arrester model to simulate the influence of the voltage harmonics described above. A pure sinusoidal voltage and its the 3r harmonic voltage were applied to the model, and the leakage current components were analyzed. From the simulation results, it is confirmed that the peak value of resistive leakage current depends not only on the phase of the 3$^{rd}$ harmonic voltage but also on the magnitude of it. Consequently, the errors caused 1)y the harmonic voltage could be minimized by correcting the magnitude of leakage current upon analyzing the harmonics.cs.

Relative humidity prediction of a leakage area for small RCS leakage quantification by applying the Bi-LSTM neural networks

  • Sang Hyun Lee;Hye Seon Jo;Man Gyun Na
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1725-1732
    • /
    • 2024
  • In nuclear power plants, reactor coolant leakage can occur due to various reasons. Early detection of leaks is crucial for maintaining the safety of nuclear power plants. Currently, a detection system is being developed in Korea to identify reactor coolant system (RCS) leakage of less than 0.5 gpm. Typically, RCS leaks are detected by monitoring temperature, humidity, and radioactivity in the containment, and a water level in the sump. However, detecting small leaks proves challenging because the resulting changes in the containment humidity and temperature, and the sump water level are minimal. To address these issues and improve leak detection speed, it is necessary to quantify the leaks and develop an artificial intelligence-based leak detection system. In this study, we employed bidirectional long short-term memory, which are types of neural networks used in artificial intelligence, to predict the relative humidity in the leakage area for leak quantification. Additionally, an optimization technique was implemented to reduce learning time and enhance prediction performance. Through evaluation of the developed artificial intelligence model's prediction accuracy, we expect it to be valuable for future leak detection systems by accurately predicting the relative humidity in a leakage area.

Development of the Leakage Current Detection Module for a Concent (콘센트용 누전감지 모듈 개발)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.3
    • /
    • pp.447-452
    • /
    • 2013
  • In this paper, the leakage current detection and auto shut-off module for a concent has been developed. Existing leakage current detection modules are detecting resistive leakage current, using a resistive leakage current detection chip but the proposed leakage current detection module separates and detects resistive leakage current in the synthesis leakage current by only programming in a power processor MCU(MSP430). The module implemented by proposed method has early detection and auto shut-off feature at more than resistive leakage current 5mA, and has the advantage of easily adjusting resistive leakage current less or more than 5mA, because of resistive leakage current detection function being implemented by a program in MCU.

Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current (누설전류로 인한 전기화재 및 감전사고 예방기법)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Kim, Jae-Hyun;Kang, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.