• 제목/요약/키워드: leakage point

검색결과 333건 처리시간 0.033초

결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구 (A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

쌍곡면 패널에의 다이폴 분포 (Dipole Distributions on a Hyperboloidal Panel)

  • 이창섭;서정천
    • 대한조선학회논문집
    • /
    • 제32권2호
    • /
    • pp.32-42
    • /
    • 1995
  • 프로펠러 뒷날과 같이 두께가 아주 얇아지는 경우, 또는 선미에서와 같이 물체 표면의 곡률이 급격하게 변하는 경우 등에서는 기존의 평균평면 패널로 물체의 표면을 대치하며 경계적분 문제를 다루면, leakage 문제를 야기하거나 유동장점이 패널에서 아주 가까이 있을 경우에는 유기속도 포텐셜이 부정확해 지는 등의 문제가 있다. 쌍곡면 패널은 그 위에 분포된 다이폴에 의해 유기되는 포텐셜을 근사화하지 않고 정확하게 계산할 수 있도록 한다. 본 연구는 방곡면에 분포된 균일 밀도의 다이폴에 의해 유기되는 포텐셜을 표현하는 적분식을 수치적으로 계산하기에 유용한 2가지 서로 다른 방법, 즉, Gauss-Bonnet 정리를 이용하여 증명하는 방법과 면적분을 선적분으로 치환하는 방법, 을 유도하고 그 정확성을 소개한다.

  • PDF

정상유동에서 유동형 단엽폴리머 인공판막의 수력학적 성능평가 (Hydrodynamic Investigation of a Floating-type Monoleaflet Polymer Valve under Steady Flow Condition)

  • 김준우;박복춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.49-60
    • /
    • 1996
  • An experimental investigation was performed under steady flow condition to assess hydrodynamic performance of floating-type monoleaflet polymer valves (MLPV) withdifferent leaflet thickness. The St. Jude Medical valve (SJMV) was also used for comparison test. Pressure drops of MLPVS are larger than those for other types of polymer valves and mechanical valves. Furthermore, the thicker is the leaflet thickness of the polymer valve, the larger are the corresponding pressure drop. The velocity profiles for MLPs reveal a large reversed flow region downward to the valve position. The maximum wall shear stresses of MLPVS at a flow rate of $30{\ell}$/min are in the range 50-130 dyn/$cm^2$, and the corresponding maximum Reynolds shear stresses are in the range of 100-500 dyn/$cm^2$, respectively, which are beyond the allowable limit clinically. In contrast, floating-type monoleaflet polymer valves show better hydrodynamic performance in leakage volume. From the designing point of view, it may be concluded that the optimum thickness of leaflet for better hydrodynamic performance is one of the Important parameters.

  • PDF

정상유동에서 유동형 단엽폴리머 인공심장판막의 수력학적 성능평가 (Hydrodynamic Investigation of a Floating-type Monoleaflet Polymer Heart Valve under Steady Flow Condition)

  • 박복춘;김준우;백병준;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.241-246
    • /
    • 1995
  • An experimental investigation was performed under steady flow condition to assess hydrodynamic performance of floating-type monoleaflet polymer valves (MLPV) with different leaflet thickness. The St. Jude Medical valve (SJMV) was also used for comparison tests. Pressure drops of MLPVs are larger than those for other types of polymer valves and mechanical valves. Furthermore, the thicker is the leaflet thickness of a polymer valve, the larger arc the corresponding press drop. The velocity profiles for MLPV reveal a large reversed flow region downward to the valve position. The maximum wall shear stresses of MLPVs at a flow rate of 30 l/min are in the range $54-130\;dyn/cm^2$, and the corresponding maximum. Reynolds shear stresses are in the range of $100-500\;dyn/cm^2$, respectively. Both arc beyond the allowable limit clinically. In contrast, floating-type monoleaflet polymer valves show better hydrodynamic performance in leakage volume. From the designing point of view, it can be concluded that the optimum thickness of leaflet for better hydrodynamic performance is one of the important parameters.

  • PDF

군집화 기법을 이용한 GIS 열화 패턴 연구 (A Study on Degradation Pattern of GIS Using Clustering Methode)

  • 이덕진
    • 한국전기전자재료학회논문지
    • /
    • 제31권4호
    • /
    • pp.255-260
    • /
    • 2018
  • In recent years, increasing electricity use has led to considerable interest in green energy. In order to effectively supply, cut off, and operate an electric power system, many electric power facilities such as gas insulation switch (GIS), cable, and large substation facilities with higher densities are being developed to meet demand. However, because of the increased use of aging electric power facilities, safety problems are emerging. Electromagnetic wave and leakage current detection are mainly used as sensing methods to detect live-line partial discharges. Although electromagnetic sensors are excellent at providing an initial diagnosis and very reliable, it is difficult to precisely determine the fault point, while leakage current sensors require a connection to the ground line and are very vulnerable to line noise. The partial discharge characteristic in particular is accompanied by statistical irregularity, and it has been reported that proper statistical processing of data is very important. Therefore, in this paper, we present the results of analyzing ${\Phi}-q-n$ cluster distributions of partial discharge characteristics by using K-means clustering to develop an expert partial discharge diagnosis system generated in a GIS facility.

삼천포화력발전소 주변해역 표층퇴적물중의 중금속원소함량 분포 연구 (A Study on the Distribution of Heavy Metal Concentrations in Marine Surface Sediments around Samcheonpo Power Plant)

  • 이두호;임주환;전병열;정년호
    • 환경영향평가
    • /
    • 제9권1호
    • /
    • pp.1-11
    • /
    • 2000
  • An environmental geochemical survey of heavy metal distribution in marine surface sediments around the ocean of Samcheonpo coal-fired power plant was conducted to investigate the possibility of coal-ash leakage from ash pond and the associated heavy metal pollution in sedimental deposits due to the operation of the coal-fired power plant. The X-Ray Diffractometry (XRD) analysis showed that the main leakage point of coal-ash was limited to a single site of the first ash pond. It also appeared that the amounts of organic carbon and metal elements were positively correlated to the grain size distribution, and that Co, Cr, Cu, Fe, Ni, and Zn were bounded to organic ligands. However, the distributions of Cd, Hg, and Mn did not have any significant correlation with the sediment grain size and organic matters. In particular, the distribution of Cd appeared to be affected by the concentration of the carbonate materials in the study area.

  • PDF

Feasibility study of a resistive-type sodium aerosol detector with ZnO nanowires for sodium-cooled fast reactors

  • Jewhan Lee;Da-Young Gam;Ki Ean Nam;Seong J. Cho;Hyungmo Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2373-2379
    • /
    • 2023
  • In sodium systems, leakage is one of the safety concerns; it can cause chemical reactions, which may result in fires. There are contact and non-contact types of leak detectors, and the conventional method of non-contact type detection is by gas sampling. Because of the complexity of this method, there has always been a need for a simple gas sensor, and the resistive-type nanostructure ZnO sensor is a promising option with various advantages. In this study, a ZnO sensor was fabricated, and the concept was tested as a leak detector using a dedicated experiment facility. The experiment results showed distinctive changes in resistance with the presence of sodium aerosol under various conditions. Replacing the conventional gas sampling with the ZnO sensors is expected to enable identification of the leakage location if used as a point-wise instrumentation and to greatly reduce the total cost, making the system simple, light, and effective. For further study, more tests will be performed to evaluate the sensitivity of key parameters under various conditions.

작은 인공판막주위 누출에 의한 용혈성 빈혈 (Hemolytic Anemia due to Tiny Prosthetic Paravalvular Leakage)

  • 문광덕;김대영
    • Journal of Chest Surgery
    • /
    • 제29권4호
    • /
    • pp.444-448
    • /
    • 1996
  • 작은 인공판막주위 누출에 의한 용혈성 빈혈은 인공판막 치환술후올수 있는 합병증중의 하나이다. 경도의 용혈은 대개 기계 판막으로 대동맥 판막 치환술을 시행했을 때 생기 지만, 드물게는 승모판막 치환 술 후에 생 기도 더욱 드물게 조직판막 치환술 후에도 생 긴다 조직판막 치환술후에 용혈성 빈혈은 거의 생기지 않는다. lonescu-Shiley 심낭판막 치환술을 받은 환자에서 용혈성 빈혈은 승모판막에서는 없었고, 대동맥판막 에서 주로 발생하였다고 보고되 어 왔다. 41세 여자환자가 갑자기 진한적색뇨가생겨 본원에 입원하였다. 이 환자는 10년전 승모판막 폐쇄부전증으로 승모판막 치환술(lonescu-Shiley판막 27mm)을 받았던 병 력 이 있다. 심초음파검사상 판막을 통한 경도의 승모판막 폐쇄부전과 함께 판막의 비후가 관찰되었으나 판막주 위를 통해 세어나오는 판막주위 누출의 소견은 관찰할 수 없었다. 말초혈액도말검사상정적혈구성 정색소성 빈혈을 보였다. 혈액 및 요 검사에서 심한 용혈소견이 보였다. 51. Jude Medical 양엽 판막(size 27mm)으로 승모판막 치환술을 시행하였다. 수술시 lonescu-Shiley 판막에 판엽의 석 회화와 뒤틀림 ( istortion)이 있었고, 술자위 치 에서 1시 방향에 직경 5mm의 작은 판막주위 누출이 발견되었으며 이것이 용혈성 빈혈의 원인으로 생각되었다. 승모판 막 재치환술후 용혈소견은 완전히 사라졌다. 저자들은 작은 인공판막주위 누출에 의한 심한 용혈성 빈혈이 발생한 1예를 경험하였기에 문헌고찰 과 함께 보고하는 바이다.

  • PDF

하천 보축제체의 배수통문 구조물 측면부 침투 특성 (Seepage Behaviors on the Box Culvert Side of Enlarged Levee)

  • 양학영;김영묵
    • 한국지반환경공학회 논문집
    • /
    • 제21권4호
    • /
    • pp.19-30
    • /
    • 2020
  • 본 연구는 하천 보축제체 내부를 관통하여 설치되는 배수통문 구조물 연결부에서 누수가 발생하는 경우 구조물 측면의 침투 특성을 파악하고 이러한 측면 침투 거동에 따른 파이핑 등이 제체 안정에 미치는 영향을 분석한 수치해석적 연구이다. 측면 침투 거동을 고려하기 위해 동일한 모델에 대해 2차원 및 3차원 수치해석을 수행하였다. 그리고 측면 침투의 영향을 분석하고 수치 해석의 타당성을 평가하고자 하였다. 연구 결과, 제외지에 수문이 위치한 조건에서 누수가 발생하고 측면 침투를 고려하는 경우 구조물 누수지점 인근의 최대간극수압은 누수가 발생하지 않는 정상적인 침투 상태에 비해 절반 정도로 감소하였다. 특히 측면 침투를 고려하지 않는 경우 구조물 하부에서 과도한 간극수압 변화를 보였다. 구조물 상부와 하부의 동수경사는 고수위로 수위가 상승하면서 한계동수경사보다 큰 동수경사를 나타내고 있어 장기간 파이핑에 취약할 것으로 판단된다. 제내지에 수문이 위치하고 측면침투를 고려하지 않는 경우 동수경사와 침투유속 등 침투수의 영향은 측면침투를 고려하는 경우에 비해 과소하게 해석되었다. 수문이 제외지에 위치하고 누수가 발생하여 파이핑 발생 또는 제체 재료 유실이 우려되는 경우 측면 침투를 무시하게 되면 최대 동수경사는 상대적으로 작게 나타났다. 그리고 한계동수경사를 초과하는 기간도 짧은 시간대로 해석되었다. 결과적으로 측면 침투를 무시하게 되면 파이핑 발생 가능성을 과소하게 평가할 수 있어 주의해야 할 것으로 판단된다.

누출 수소 환기에 영향을 미치는 요인별 환기 특성에 관한 수치해석적 연구 (A Numerical Study on Ventilation Characteristics of Factors Affecting Leakages in Hydrogen Ventilation)

  • 이창용;조대환
    • 해양환경안전학회지
    • /
    • 제28권4호
    • /
    • pp.610-619
    • /
    • 2022
  • 수소는 산소와 반응하여 전기에너지를 만들고 부산물로 물을 생성하므로 친환경 선박의 대체 연료로 대두되고 있다. 그러나 수소는 일반 화석연료와는 달리 낮은 점화 에너지와 높은 가연성 범위로 인하여 폭발의 위험성이 높은 물질이다. 그래서 선박에서 사용되는 수소의 안전성을 확보하기 위해서 수소의 누출·확산에 관한 유동 특성을 연구하는 것은 매우 중요하다. 본 연구에서는 선박 내부와 같은 밀폐공간에서 수소가 누출되었을 때 누출량, 통풍량, 환기 방식 등이 환기 성능에 어떤 영향을 미치는지에 대하여 수치적 해석을 수행하였다. 수치해석에는 CFD 상용 소프트웨어인 ANSYS CFX ver 18.1을 이용하였다. 누출량은 1 q = 1 g/s로 하여 1 q, 2 q, 3 q로 변경하였고, 통풍량은 1 Q = 0.91 m/s로 하여 1 Q, 2 Q, 3 Q로 변경하였으며 환기 방식은 typeI, typeII, typeIII로 변경하면서 환기 성능을 분석하였다. 누출량이 1 q에서 3 q로 증가할수록 저장실 내의 수소 몰분율(HMF)는 약 2.4 ~ 3.0배 높게 나타났으며 통풍량 증가는 누출량에 대비하여 약 62.0 ~ 64.8 % 정도 환기 성능이 개선에 효과가 있었다. 그리고 폭발의 위험성을 낮추기 위한 통풍량은 최소 2 Q 이상 되어야 하며, 수소탱크 저장실 내부의 부압 형성을 위해서는 type III가 가장 적합한 방식이라고 판단하였다.