• Title/Summary/Keyword: leakage of dye

Search Result 149, Processing Time 0.023 seconds

EFFECTS OF CONDENSATION TECHNIQUES AND CANAL SIZES ON THE MICROLEAKAGE OF ORTHOGRADE MTA APICAL PLUG IN SIMULATED CANALS (모조 근관의 크기와 충전 방법이 orthograde MTA apical plug의 미세누출에 미치는 영향)

  • Nam, Deuk-Lim;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.208-214
    • /
    • 2009
  • The purpose of this study was to compare the dye leakage of MTA (mineral trioxide aggregate) apical plug produced by two orthograde placement techniques (hand condensation technique and ultrasonically assisted hand condensation technique). To simulate straight canal, 60 transparent acrylic blocks with straight canal were fabricated. These transparent acrylic blocks were divided into 2 groups (Group C; hand condensation technique (HC) and Group U; ultrasonically assisted hand condensation technique (UAHC)) of 30 blocks with each MTA application method. Each group was divided into 2 subgroups (n=15) with different canal size of #70 (subgroup C70 and subgroup U70) and #120 (subgroup C120 and subgroup U120). After apical plug was created, a wet paper point was placed over the MTA plug and specimen was kept in a humid condition at room temperature to allow MTA to set. After 24 hours, remaining canal space was backfilled using Obtura II. All specimens were transferred to floral form socked by 0.2% rhodamine B solution and stored in 100% humidity at room temperature. After 48 hours, resin block specimens were washed and scanned using a scanner. The maximum length of micro leakage was measured from the scanned images of four surfaces of each resin block using Photoshop 6.0. Statistical analysis was performed with Mann-Whitney U test. Group U of UAHC had significantly lower leakage than Group C of HC in #70-size canal (subgroup U70) (p<0.05).

THE EFFECT OF SMEAR LAYER TREATMENT ON THE MICROLEAKAGE (Smear layer 처리에 따른 미세누출에 대한 연구)

  • Lee, Jung-Min;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.378-389
    • /
    • 2006
  • The purpose of this study was to compare the sealing ability of root canal obturation with or without the treatment of smear layer. Eighty extracted human teeth with one canal were selected Instrumentation was performed with crown-down technique. After instrumentation, root canals of the NaOCl group and NaOCl-6 group were irrigated with 3% NaOCl. EDTA group and EDTA-6 group were irrigated with 17% EDTA. Then all teeth were obturated using continuous wane obturation technique NaOCl group and EDTA group were immersed in methylene blue solution for 84hours. NaOCl-6 group and EDTA-6 group were immersed in methylene blue solution for 6months. The teeth were sectioned at 1.5 mn (Level 1), 3.0 mm (Level 2) and 4.5 mm (Level 3) from the root apex. The length of dye-penetrated inter-face and the circumferential length of canal at each level were measured using Sigma-Scan Pro 5.0. 1. The mean leakage ratio was decreased cervically. 2. NaOCl group showed higher mean leakage ratio than EDTA group at each level. But there was significant difference at level 1 only (p < 0.05). 3. NaOCl-6 group showed higher mean leakage ratio than EDTA-6 group at each level. But there was significant difference at level 1 only (p < 0.05). 4. NaOCl-6 group showed higher mean leakage ratio than NaOCl group at each level. But there was significant difference at level 1 only (p < 0.05). 5. EDTA-6 group showed higher mean leakage ratio than EDTA group at each level. But there was no significant difference. 6. In NaOCl group and NaOCl-6 group, scanning electron micrographs of tooth sections generally covered with smear layer. In EDTA group and EDTA-6 group, tooth sections showing the penetration of sealers to opened dentinal tubules. The results suggest that removal of smear layer was effective to reduce the apical microleakage of the root canal.

Comparison of apical sealing ability of continuous wave of obturation technique using EndoTwinn and System B (EndoTwinn과 System B continuous wave of obturation units를 이용한 근단부 근관충전 효율비교)

  • Shin, Hyun-Ju;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.522-529
    • /
    • 2007
  • The purpose of this study was to compare the apical leakage of the root canal filled with the System B and the EndoTwinn(the combined application of heat and ultrasonic vibration). Sixty extracted premolars with straight root were cleaned and shaped to size 35. Group SB was obturated using System B and Group ET was filled with EndoTwinn. A size 35 of 0.06 tapered gutta-percha and Adseal were used and the plugger which could be introduced to 4 mm short of working length was selected in the obturation procedure. As the positive control, Group PC was not filled. In Group SB, ET and PC, all external surfaces of each tooth were coated with nail varnish leaving only 1 mm area around the apical foramen. In the negative control of Group NSB and Group NET, all of external tooth surface including apical foramen was coated with the nail varnish. The specimens were immersed in methylene blue dye solution for 2 days. Then the specimens were sectioned at each 1 mm from apex to 5 mm level. The final score of one specimen was given by summing up of the points at all levels. The dye leakage of Group ET was significantly less than that observed in Group SB (p < 0.05). And the frequency of gutta-percha pulling out from root canal when the plugger was removed was more often with the System B than with EndoTwinn but there was no significant difference.

MICROLEAKAGE OF RESILON BY METHACRYLATE-BASED SEALER AND SELF-ADHESIVE RESIN CEMENT (Resilon을 이용한 근관충전 시 레진계열의 근관실러와 자가-접착 레진시멘트에 따른 미세누출)

  • Ham, Sun-Young;Kim, Jin-Woo;Shin, Hye-Jin;Cho, Kyung-Mo;Park, Se-Hee
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.204-212
    • /
    • 2008
  • The purpose of this study was to compare the apical microleakage in root canal filled with Resilon by methacrylate-based root canal sealer or 2 different self-adhesive resin cements. Seventy single-rooted extracted human teeth were sectioned at the CEJ perpendicular to the long axis of the roots with diamond disk. Canal preparation was performed with crown-down technique using Profile NiTi rotary instruments and GG drill. Each canal was prepared to ISO size 40, .04 taper and 1 mm short from the apex. The prepared roots were randomly divided into 4 experimental groups of 15 roots each and 5 roots each for positive and negative control group. The root canals were filled by lateral condensation as follows. Group 1: Gutta-percha with AH-26, Group 2: Resilon with RealSeal primer & sealer, Group 3: Resilon with Rely-X Unicem, Group 4: Resilon with BisCem. After stored in $37^{\circ}C$, 100% humidity chamber for 7 days, the roots were coated with 2 layers of nail varnish except apical 3 mm. The roots were then immersed in 1% methylene blue dye for 7 days. Apical microleakage was measured by a maximum length of linear dye penetration after roots were separated longitudinally. One way ANOVA and Scheffe's post-hoc test were performed for statistical analysis. Group 1 showed the least apical leakage and there was no statistical significance between Group 2, 3, 4. According to the results, the self adhesive resin cement is possible to use as sealer instead of primer & sealant when root canal filled by Resilon.

  • PDF

MICROLEAKAGE OF RESILON BY METHACRYLATE-BASED SEALER AND SELF-ADHESIVE RESIN CEMENT (Resilon을 이용한 근관충전 시 레진계열의 근관실러와 자가-접착 레진시멘트에 따른 미세누출)

  • Ham, Sun-Young;Kim, Jin-Woo;Shin, Hye-Jin;Cho, Kyung-Mo;Park, Se-Hee
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.204-212
    • /
    • 2008
  • The purpose of this study was to compare the apical microleakage in root canal filled with Resilon by methacrylate-based root canal sealer or 2 different self-adhesive resin cements. Seventy single-rooted extracted human teeth were sectioned at the CEJ perpendicular to the long axis of the roots with diamond disk. Canal preparation was performed with crown-down technique using Profile NiTi rotary instruments and GG drill. Each canal was prepared to ISO size 40, .04 taper and 1 mm short from the apex. The prepared roots were randomly divided into 4 experimental groups of 15 roots each and 5 roots each for positive and negative control group. The root canals were filled by lateral condensation as follows. Group 1: Guttapercha with AH-26, Group 2: Resilon with RealSeal primer & sealer, Group 3: Resilon with Rely-X Unicem, Group 4: Resilon with BisCem. After stored in $37{\circ}C$, 100% humidity chamber for 7 days, the roots were coated with 2 layers of nail varnish except apical 3 mm. The roots were then immersed in 1% methylene blue dye for 7 days. Apical microleakage was measured by a maximum length of linear dye penetration after roots were separated longitudinally. One way ANOVA and Scheffe's post-hoc test were performed for statistical analysis. Group 1 showed the least apical leakage and there was no statistical significance between Group 2, 3, 4. According to the results, the self adhesive resin cement is possible to use as sealer instead of primer & sealant when root canal filled by Resilon.

THE EFFECT OF CONSISTENCY OF SEALER ON CANAL OBTURATION IN INJECTION-THERMOPLASTICIZED GUlTA-PERCHA METHOD (연화(軟化) Gutta-percha 충전법(充塡法)에서 Sealer의 조도(稠度)가 근관폐쇄(根管閉鎖)에 미치는 영향(影響))

  • Lee, Young-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.38-48
    • /
    • 1989
  • The purpose of this study was to investigate the proper consistency of root canal sealer needed in obtaining an efficient canal obturation in injection-thermoplasticized low-temperature ($70^{\circ}C$) gutta-percha method. The sealer was made by incorporating zinc oxide powder into $0.5m{\ell}$ of eugenol and then the $0.5m{\ell}$ of mixture slurry was placed between two flat glass plates. The consistency was determined by measuring the degree of spread of the slurry at loading the 120gm of weight from the top plate. The sealer was prepared according to P/L ratio corresponding to the acquired consistency of 65.45mm, 46.80mm, 28.95mm and 22.60mm. The distal roots were obtained by cutting off from 125 extracted human lower molars and the root canals were prepared by using step-back method. The prepared canals were coated with the sealers on their walls and obturated by using the injection-thermoplasticized low-temperature ($70^{\circ}C$) gutta-percha method. All specimens were immersed in 2% methylene blue dye solution for 48 hours at $37^{\circ}C$. Calipers was used to measured the dye penetration into the root canals from apical constrictions. The results were as follows : The canals obturated without sealer showed significantly more leakage than the canals obturated with sealer. Within the consistency from 65.45mm to 22.60mm, the sealer of 65.45mm appeared significantly better than that of 28.95mm and 22.60mm in the canals obturated by injection-thermoplasticized gutta-percha method, and better than that of 46.80mm without statistical significance.

  • PDF

Physical Property and Stability of Liposome Prepared from Egg Yolk Phospholipids at Various Storage Conditions (난황 유래 인지철로 합성한 리포좀의 물리적 특성과 안정성)

  • Park, Sun-Hyun;Kim, Myung-Hee
    • Food Science of Animal Resources
    • /
    • v.28 no.5
    • /
    • pp.549-554
    • /
    • 2008
  • Liposomes were prepared from egg yolk phospholipids to study their physical properties and stability at various storage conditions. Under storage conditions at different pH levels, the particle sizes of liposomes increased at the range of pH 1-2, and the absolute values of $\xi$-potentials were reduced at the range of pH 1-4. The leakage of sulforhodamine B (SRB), a fluorescent dye which is encapsulated in the liposome, increased greatly at pH 2-4. At different storage temperatures, the particle size of liposomes increased from the 10 days of storage at $4^{\circ}C$ and the 40 days at 20 and $35^{\circ}C$. The $\xi$-potentials decreased slightly later during storage under 4, 20 and $35^{\circ}C$. At the storage temperature of $50^{\circ}C$, the leakage of SRB was the greatest. Therefore, we concluded that the pH conditions lower than pH 6 and high temperature of $50^{\circ}C$ are not conducive to storing liposomes. The results obtained here may prove helpful in developing liposome-based encapsulation and diagnostic reagents.

POLYMERIZATION SHRINKAGE, HYGROSCOPIC EXPANSION AND MICROLEAKAGE OF RESIN-BASED TEMPORARY FILLING MATERIALS (레진계 임시수복재의 중합수축, 수화팽창과 미세누출)

  • Cho, Nak-Yeon;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.115-124
    • /
    • 2008
  • The purpose of this study was to measure the polymerization shrinkage and hygroscopic expansion of resin-based temporary filling materials and to evaluate microleakage at the interface between the materials and cavity wall. Five resin-based temporary filing materials were investigated: Fermit (Vivadent), Quicks (Dentkist), Provifil (Promedica), Spacer (Vericom), Clip (Voco). Caviton (GC) was also included for comparison. Polymerization shrinkage of five resin-based temporary filling materials was measured using the bonded disc method. For the measurement of hygroscopic expansion, the discs of six cured temporary filling materials were immersed in saline and a LVDT displacement sensor was used to measure the expansion for 7 days. For estimating of microleakage, Class I cavities were prepared on 120 extracted human molars and randomly assigned to 6 groups of 20 each. The cavities in each group were filled with six temporary filling materials. All specimens were submitted to 1000 thermocycles, with temperature varying from $5^{\circ}C/55^{\circ}C$. Microleakage was determined using a dye penetration test. The results were as follows: 1. Fermit had significantly less polymerization shrinkage than the other resin-based temporary fill ing materials. Fermit (0.22%) < Spacer (0.38%) < Quicks (0.64%), Provifil (0.67%), Clip (0.67%) 2. Resin-based temporary filling materials showed 0.43-1.1% expansion in 7 days. 3. Fermit showed the greatest leakage, while Quicks exhibited the least leakage. 4. There are no correlation between polymerization shrinkage or hygroscopic expansion and microleakage of resin-based temporary filling materials.

The Microleakage in Class V Cavity Based on Different Kinds of Several Dentin Adhesive and Composite Resin (5급 와동에서 수종의 상아질 접착제와 복합레진의 종류에 따른 미세누출)

  • Choi, Yoo-Seok;Jeong, Soon-Jeong;Jeong, Moon-Jin;Ahn, Yong-Soon;Park, Seon-Nyeo;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.13 no.3
    • /
    • pp.330-338
    • /
    • 2013
  • In order to explore microleakage in class V cavity based on different kinds of several dentin adhesive and composite resin, 2 kinds of composite resin was restored and exposed after applying 4 kinds of dentin adhesives. Deposited in methylene blue solution for 4 hours and cut in parallel with tooth longitudinal axis. By observing dye penetration level of enamel and dentin margins of each restored resin following conclusion was obtained. 1. In composite resin Filtek Z350XT Universal (3M/ESPE Dental Products, USA) in enamel margin, Easy Bond (3M/ESPE Dental Products) showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2 (3M/ESPE Dental Products), Scotchbond Multi-Purpose (3M/ESPE Dental Products) and Cearfil SE Bond (Kuraray Medical Inc., Japan). In case of Filtek Z350XT Flowable (3M/ESPE Dental Products), Scotchbond Multi-Purpose showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2, Clearfil SE Bond and Easy Bond. 2. In case of Filtek Z350XT Universal in dentin margin, Easy Bond showed the lowest microleakage and this leakage was represented to be high in the order of Scotchbond Multi-Purpose, Single Bond 2 and Clearfil SE Bond. In case of Filtek Z350XT Flowable, Scotchbond Multi-Purpose and Single Bond showed the lowest microleakage and this leakage was represented to be high in the order of Clearfil SE Bond and Easy Bond. 3. In all the groups excepting S-U group (Single Bond 2+Filtek Z350XT Universal), enamel margin showed more higher microleakage than that of dentin margin. 4. There was a difference between enamel and dentin margin among each group but it was not significant statistically (p>0.05). When summarizing this result, it is considered that composite resin and dentin adhesive could be applied selectively and particularly in case of applying 1-step self-etching dentin adhesive, this method would be advantageous for manipulation convenience and shortening of operation time.

Diagnosis and Treatment of the Ankle Sprain using Arthrography (관절 조영술을 이용한 족관절 염좌의 진단과 치료)

  • Kim, Seok-Jung;Ok, In-Young;Chu, In-Tak;Song, Seok-Whan;Ha, Kee-Yong;Kim, Yong-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.2
    • /
    • pp.194-200
    • /
    • 2003
  • Purpose: To evaluate the effectiveness of ankle arthrography in diagnosis and treatment of the ankle sprain. Materials and Methods: Arthrography was performed to eighteen patients who were diagnosed as ankle sprain clinically from September, 1990 to April, 2003. Splint immobilization for three days and return to daily life were for the eleven patients who showed normal limits of extension of joint and no dye leakage on arthrography, cast for 3 weeks and compression brace wearing were for 4 patients who showed anterior talofibular ligament tear on arthrography. 3 patients diagnosed as anterior talofibular and calcaneofibular ligament tears were treated with cast for 6 weeks and then brace for 3 weeks. Results: The range of motion of the injured joint was recovered normally at the time of 3 month of postoperative follow up examination. But two patients complained a mild pain after exercise but it did not affect ordinary activities. Eleven patients who were normal on arthrography returned to daily activities in a week. Conclusion: It is reasonable to determine the extent of ankle sprain and treatment method for it using arthrography.

  • PDF