• 제목/요약/키워드: leakage component

검색결과 187건 처리시간 0.028초

An Efficient Variable Rearrangement Technique for STT-RAM Based Hybrid Caches

  • 윤종희;조두산
    • 대한임베디드공학회논문지
    • /
    • 제11권2호
    • /
    • pp.67-78
    • /
    • 2016
  • The emerging Spin-Transfer Torque RAM (STT-RAM) is a promising component that can be used to improve the efficiency as a result of its high storage density and low leakage power. However, the state-of-the-art STT-RAM is not ready to replace SRAM technology due to the negative effect of its write operations. The write operations require longer latency and more power than the same operations in SRAM. Therefore, a hybrid cache with SRAM and STT-RAM technologies is proposed to obtain the benefits of STT-RAM while minimizing its negative effects by using SRAM. To efficiently use of the hybrid cache, it is important to place write intensive data onto the cache. Such data should be placed on SRAM to minimize the negative effect. Thus, we propose a technique that optimizes placement of data in main memory. It drives the proper combination of advantages and disadvantages for SRAM and STT-RAM in the hybrid cache. As a result of the proposed technique, write intensive data are loaded to SRAM and read intensive data are loaded to STT-RAM. In addition, our technique also optimizes temporal locality to minimize conflict misses. Therefore, it improves performance and energy consumption of the hybrid cache architecture in a certain range.

A Family of Magnetic Coupling DC-DC Converters With Zero-Voltage-Switching Over Wide Input Voltage Range and Load Variation

  • Chen, Guipeng;Dong, Jie;Deng, Yan;Tao, Yong;He, Xiangning;Wang, Yousheng
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1639-1649
    • /
    • 2016
  • This paper presents a family of soft-switching DC-DC converters with a simple auxiliary circuit consisting of a coupled winding and a pair of auxiliary switch and diode. The auxiliary circuit is activated in a short interval and thus the circulating conduction losses are small. With the auxiliary circuit, zero-voltage-switching (ZVS) and zero-current-switching are achieved for the main and auxiliary switches respectively, over wide input voltage range and load variation. In addition, the reverse-recovery problem of diodes is significantly alleviated because of the leakage inductor. Furthermore, the coupled inductor simultaneously serves as the main and auxiliary inductors, contributing to reduced magnetic component in comparison with the conventional zero-voltage-transition (ZVT) converters. Experimental results based on a 500 W prototype buck circuit validate the advantages and effectiveness of the proposed magnetic coupling ZVS converter.

Experiments on the Thermal Stratification in the Branch of NPP

  • Kim Sang Nyung;Hwang Seon Hong;Yoon Ki Hoon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권5호
    • /
    • pp.1206-1215
    • /
    • 2005
  • The thermal stratification phenomena, frequently occurring in the component of nuclear power plant system such as pressurizer surge line, steam generator inlet nozzle, safety injection system (SIS), and chemical and volume control system (CVCS), can cause through-wall cracks, thermal fatigue, unexpected piping displacement and dislocation, and pipe support damage. The phenomenon is one of the unaccounted load in the design stage. However, the load have been found to be serious as nuclear power plant operation experience accumulates. In particular, the thermal stratification by the turbulent penetration or valve leak in the SIS and SCS pipe line can lead these safety systems to failure by the thermal fatigue. Therefore in this study an 1/10 scaledowned experimental rig had been designed and installed. And a series of experimental works had been executed to measure the temperature distribution (thermal stratification) in these systems by the turbulent penetration, valve leak, and heat transfer through valve. The results provide very valuable informations such as turbulent penetration depth, the possibility of thermal stratification by the heat transfer through valve, etc. Also the results are expected to be useful to understand the thermal stratification in these systems, establish the thermal strati­fication criteria and validate the calculation results by CFD Codes such as Fluent, Phenix, CFX.

바이오에탄올 연료에 대한 FFV(Flexible Fuel Vehicle)용 연료펌프모터의 내구성에 관한 연구 (A Study of Fuel Pump Durability on the Bio-ethanol for FFV(Flexible Fuel Vehicle) System)

  • 김창수;곽동호;정병준;김종명
    • 한국자동차공학회논문집
    • /
    • 제19권6호
    • /
    • pp.107-112
    • /
    • 2011
  • FFV(Flexible Fuel Vehicle) is the vehicle that can be used liberally from gasoline to E100(Ethanol 100%) for fuel. Recently, interest in the bio-fuel is increased by the environmental factors like exhaustion of the fossil fuel and ruduction of greenhouse gases. For the reason, adopting of FFV is activated in the world including North and South America. In general, bio-ethanol has highly corrosive substance in compare with gasoline. In the part of fuel system, corrosion can make a safety problem in case of fuel leakage and engine starting problem. So the fuel system of FFV have to be made of high corrosion-resistant materials. This study examined the effect of bio-ethanol on the durability properties according to component materials in FFV fuel pump motor and regulator using the High Temperature Fuel Circulation Test.

저온 플라즈마 발생을 위한 ASM 방식의 펄스파워 발생장치에 관한 연구 (A Study on ASM Pulsed Power Generator for Non-thermal Plasma Applications)

  • 양천석;정용호;김한준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2035-2037
    • /
    • 1999
  • This paper describes an ASM(All Solid-state Modulator) pulsed power generator for non-thermal plasma applications. The proposed generator can produce 20kV, 500A, 100ns pulses at repetition rates up to 10kHz, and it is composed of 30 series connections of power circuit card assembly which contains paralleled MOSFETs, MOSFET drivers, energy storage capacitors and specially designed 1:1 pulse transformer. Higher pulse voltages and currents can easily be obtained by increasing the numbers of series and parallel connections of power circuit card and MOSFETs, respectively. Component layouts are optimized to minimize the leakage inductance and the voltage spikes across switching devices. Especially it put emphasis on the over-current protection (including short circuit) for the reliable operation in real situations. Experimental results show that the proposed pulser is very efficient in air pollution control application and could be useful for other applications such as synthesis of nanosize powders and non-thermal food processing.

  • PDF

액체로켓용 터보펌프 성능예측에 대한 수치해석적 연구 (Numerical Studies on the Performance Prediction of a Turbopump System for Liquid Rocket Engines)

  • 최창호;이기수;김진한;양수석;이대성
    • 한국유체기계학회 논문집
    • /
    • 제5권2호
    • /
    • pp.15-21
    • /
    • 2002
  • The hydraulic performance analysis of an entire pump system composed of inducer, impeller, volute and seal for the application of turbopumps is numerically performed using three-dimensional Navier-Stokes equations. A quasi-steady mixing-plane method is used on the impeller/volute interface to simulate the unsteady interaction phenomena. From this work, the effects of each component on the pump performance are investigated at design and off-design conditions through the analysis of flow structures and loss mechanisms. The computational results are in a good agreement with experimental ones in terms of the headrise and efficiency even though very complex flow structures are present. It is found that the asymmetric pressure distribution along the volute wall constitutes the main reason of the difference between experimental and computational results, due to the limitation of the quasi-steady method. Since the volute was found to be over-designed by the pressure distribution of the volute wall, re-design of the volute has been performed, resulting in an improved performance characteristic.

비접촉 전압위상 검출 기술을 이용한 무정전 절연저항 측정 방법에 관한 연구 (A Study on Measurement Technique of Insulation Resistance for Non-interrupting Inspection Using Non-contact Voltage Phase Detection Technology)

  • 이기연;문현욱;김동우;임용배;최동환;김용혁
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.1106-1112
    • /
    • 2018
  • In this paper, measurement techniques are presented to test the performance of insulation without interruption if it is difficult to measure insulation resistance. Especially, non-contact voltage phase detection techniques have been developed that can be applied in environments where it is difficult to find voltage measurement locations such as component receptors. The performance verification of the non-interrupting insulation resistance measuring devices has been tested against existing products using standard calibration equipment and test jigs. The validation confirmed performance within 2 % for direct contact type and within 10 % for non-contact type. In addition, the procedure to make continuous insulation test using the equipment was proposed.

가변 용적형 사판식 피스톤 펌프의 회전 속도 조절에 의한 정압 제어 소비 동력 절감 (Reduction of Power Consumption for Constant Pressure Control of Variable Swash Plate-type Piston Pump by Varying the Pump Speed)

  • 김종혁;홍예선
    • 드라이브 ㆍ 컨트롤
    • /
    • 제11권4호
    • /
    • pp.53-60
    • /
    • 2014
  • This paper proposes a control scheme to reduce the power consumption of a variable displacement swash-plate type piston pump supplying oil to a valve-controlled hydraulic cylinder at constant pressure. Whenever flow rate demand was absent, the swash plate angle and the pump speed were changed to the minimum values required to compensate for the internal leakage flow. In response to command signals, the pump speed was changed in proportion to the absolute mean value of the speed component for position commands. At the same time, a pressure regulator was activated to maintain constant system pressure by precisely adjusting the pump speed with the swash plate angle fixed at the maximum. The conventional system consisting of a pressure-compensated variable displacement type pump is driven at a constant speed of 1,800rpm. By comparison, computer simulation and experimental results showed that idling power at stand-by status could be reduced by up to 70% by reducing the pump speed from 1,800rpm to 300rpm and the swash plate angle to the minimum.

전류변성기의 비오차와 위상오차의 절대 평가 기술 (Absolute Evaluation Method to Obtain Ratio Error and Phase Displacement of Current Transformers)

  • 김윤형;정재갑;한상길;구경완;한상옥
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.153-159
    • /
    • 2008
  • We have developed an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) without any precise standard CT by measuring four parameters in a CT equivalent circuit. The excitation admittance in the CT equivalent circuit can be obtained by employing standard resistors with negligible reactive component. The secondary leakage impedance in the CT equivalent circuit can be measured using a universal impedance bridge. The method was applied to CTs under test with the wide current ratios in the range of 5 A / 5 A - 5,000 A / 5 A and 5 A / 1 A - 5,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Canada using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

A Failure Estimation Method of Steel Pipe Elbows under In-plane Cyclic Loading

  • Jeon, Bub-Gyu;Kim, Sung-Wan;Choi, Hyoung-Suk;Park, Dong-Uk;Kim, Nam-Sik
    • Nuclear Engineering and Technology
    • /
    • 제49권1호
    • /
    • pp.245-253
    • /
    • 2017
  • The relative displacement of a piping system installed between isolated and nonisolated structures in a severe earthquake might be larger when without a seismic isolation system. As a result of the relative displacement, the seismic risks of some components in the building could increase. The possibility of an increase in seismic risks is especially high in the crossover piping system in the buildings. Previous studies found that an elbow which could be ruptured by low-cycle ratcheting fatigue is one of the weakest elements. Fatigue curves for elbows were suggested based on component tests. However, it is hard to find a quantitative evaluation of the ultimate state of piping elbows. Generally, the energy dissipation of a solid structure can be calculated from the relation between displacement and force. Therefore, in this study, the ultimate state of the pipe elbow, normally considered as failure of the pipe elbow, is defined as leakage under in-plane cyclic loading tests, and a failure estimation method is proposed using a damage index based on energy dissipation.