• Title/Summary/Keyword: leakage

Search Result 7,725, Processing Time 0.037 seconds

The Effectiveness Analysis of the Resistive Leakage Current Monitoring by Analyzing the Phase of the Body Current (인체 통전전류 위상 분석을 통한 저항성 누설전류 감시의 유효성 분석)

  • Kim, Jae-Hyun;Lim, Young-Bea;Lee, Sang-Ick;Kim, Dong-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.90-99
    • /
    • 2013
  • To analyze the effectiveness of the resistive leakage current monitoring as a technology preventing electrical accidents, in this paper, we have estimated the phase of the body impedance by using the body impedance model and the body impedance data from IEC. We also have analyzed the phase of the electric body current in the case of 60Hz/220V. From these results, we concluded that deliberate researches about the phase of the electrical body current and related regulations must be carried out before the resistive leakage current monitoring unit is used to protect electric shock. And we concluded that the resistive leakage current monitoring unit can be utilized to prevent electrical fires caused by electric leakage current without unwanted circuit break due to capacitive leakage current flowing from line filter capacitors to the earth.

A Study on Setting Methods of Economic Level of Leakage in Water Pipe Networks (상수도 관망에서의 경제적인 누수관리목표 산정 방안 연구)

  • Hwang, Jinsoo;Choi, Taeho;Lee, Doojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.237-248
    • /
    • 2017
  • The estimation method of economical leakage management target utilized upon planning business for improvement of revenue water ratio in South Korea is presented and applicability of methods developed in this study is assessed through application on site. With a consideration of revenue water ratio in application target area, estimation method of long-term economical leakage management target is applied. Three leakage reduction methods such as replacement of residual aged pipe, leakage investigation and restoration and water pressure management are applied with a consideration of characteristics of site. Due to difficulty of obtaining data, analysis of cost/benefit by leakage reduction methods is performed by applying method of leakages estimation equation among statistical methods. As a result of application, revenue water ratio corresponding to long-term economical leakage management target is 91.6 %.

A Design and Implementation of a Solution for Real Detection of Information Leakage by Keylogging Attack (키로깅을 통한 정보유출 실시간 탐지 솔루션 설계 및 구현)

  • Choi, In Young;Choi, Ji Hun;Lee, Won Yeoul
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.10
    • /
    • pp.1198-1204
    • /
    • 2014
  • Most of vaccine type security solutions detect intrusion of computer virus or malicious code. However, they almost don't have functionalities of the information leakage detection. In particular, information leakage through keylogging attact cannot be detected. In this paper, we design and implement a solution to detect the leakage of information through keylogging attact. Proposed solution detects the user-specified information in real time. To detect the leakage of user-specified information, the solution extracts the payload field from each outbound packet and compares with user-specified information. We design the solution to reduce the effect on the packet transmission delay time due to packet monitoring operation. And we design a simple user interface. By proposed solution, user can response to intrusion or information leakage immediately because he or she can perceives a leakage of information in real time.

Evaluation on the leakage of ground-water through fractured rock under a spillway (여수로 구조물 하부 암반 내 발달한 절리들을 통한 지하수 누수량 분석)

  • Kim, Hyoung-Soo;Lee, Ju-Hyun;Jeong, Ui-Jin;Lee, Joong-Woo
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.2
    • /
    • pp.129-134
    • /
    • 2006
  • Recently, spillways are need to control stable water level for supporting main dams because of floods by unusual change of weather such as Typhoon Rusa. This study has been focused on the amount of leakage through the rock mass distributed fractures and joints under the opened emergency spillway. It is very important to evaluate the amount of leakage as these affect stability of spillway by interaction between effective stress and pore pressure. The commercial program MAFIC has been used for analyzing groundwater flow in fractured rock mass. The results showed that the values of range, average and deviation of leakage were 2.85∼3.79×10-1, 3.32×10-1 and 1.70×10-2 m3/day/m2 respectively. Secondary, we have estimated the effect of grouting after the transmissivity(Tf) of joint 1 as main pathway of leakage known from above results was changed from 1.78×10-7 to 1.59×10-9 m2/s. The results showed that the values of range, average and deviation of leakage were 7.80×10-4∼1.53×10-3, 1.18×10-3 and 1.32×10-4 m3/day/m2 respectively. As the result, the amount of leakage after grouting has been decreased by a ratio of 1 to 277.

  • PDF

Self-healing and leakage performance of cracks in the wall of a reinforced concrete water tank

  • Gao, Lin;Wang, Mingzhen;Guo, Endong;Sun, Yazhen
    • Earthquakes and Structures
    • /
    • v.16 no.6
    • /
    • pp.727-741
    • /
    • 2019
  • A reinforced concrete water tank is a typical functional liquid storage structure and cracks are the greatest threat to the liquid storage structure. Tanks are readily cracked due to seismic activity, thereby leading to the leakage of the stored liquid and a loss of function. In order to study the effect of cracks on liquid storage tanks, self-healing and leakage tests for bending cracks and through cracks in the walls of a reinforced concrete water tank were conducted. Material performance tests were also performed. The self-healing performance of bending cracks in a lentic environment and through cracks in a lotic environment were tested, thereby the self-healing width of bending micro-cracks in the lentic environment in the short term were determined. The through cracks had the capacity for self-healing in the lotic environment was found. The leakage characteristics of the bending cracks and through cracks were tested with the actual water head on the crack. The effects on liquid leakage of the width of bending cracks, the depth of the compression zone, and the acting head were determined. The relationships between the leakage rate and time with the height of the water head were analyzed. Based on the tests, the relationships between the crack characteristics and self-healing as well as the leakage were obtained. Thereby the references for water tank structure design and grading earthquake damage were provided.

Relative humidity prediction of a leakage area for small RCS leakage quantification by applying the Bi-LSTM neural networks

  • Sang Hyun Lee;Hye Seon Jo;Man Gyun Na
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1725-1732
    • /
    • 2024
  • In nuclear power plants, reactor coolant leakage can occur due to various reasons. Early detection of leaks is crucial for maintaining the safety of nuclear power plants. Currently, a detection system is being developed in Korea to identify reactor coolant system (RCS) leakage of less than 0.5 gpm. Typically, RCS leaks are detected by monitoring temperature, humidity, and radioactivity in the containment, and a water level in the sump. However, detecting small leaks proves challenging because the resulting changes in the containment humidity and temperature, and the sump water level are minimal. To address these issues and improve leak detection speed, it is necessary to quantify the leaks and develop an artificial intelligence-based leak detection system. In this study, we employed bidirectional long short-term memory, which are types of neural networks used in artificial intelligence, to predict the relative humidity in the leakage area for leak quantification. Additionally, an optimization technique was implemented to reduce learning time and enhance prediction performance. Through evaluation of the developed artificial intelligence model's prediction accuracy, we expect it to be valuable for future leak detection systems by accurately predicting the relative humidity in a leakage area.

LIGHT-DEPENDENT CELLULAR LEAKAGE FROM CUCUMBER COTYLEDON DISCS TREATED WITH $\delta$-AMINOLEVULINIC ACID, OXYFLUORFEN, AND ROSE BENGAL

  • Lee, Hee-Jae;Cho, Kwang-Yun
    • Journal of Photoscience
    • /
    • v.3 no.1
    • /
    • pp.1-7
    • /
    • 1996
  • When cucumber (Cucumis sativus L.) cotyledon discs were floated on $\delta$-aminolevulinic acid, oxyfluorfen, or rose bengal solution under light condition following 20 h dark incubation, rapid electrolyte leakage from the tissues occurred. The electrolyte leakage from the tissues was dependent on the compounds treated, their concentrations, and the duration of light exposure to the tissues. Dark incubation before exposure to continuous white light enhanced electrolyte leakage from the tissues treated with the compounds and reduced lag period for the activity of the compounds. Electrolyte leakage from the treated tissues was greatly influenced by the light intensity to which they were exposed. Higher light intensities stimulated electrolyte leakage and reduced lag period. Porphyrin biosynthesis inhibitors, gabaculine and 4,6-dioxoheptanoic acid, completely inhibited electrolyte leakage from the oxyfluorfen-treated tissues. Protection against the activity of $\delta$-aminolevulinic acid from electrolyte leakage was complete with 4,6-dioxoheptanoic acid, but not with gabaculine. However, gabaculine and 4,6-dioxoheptanoic acid gave no such protection against rose bengal activity. In summary, our results indicate that $\delta$--aminolevulinic acid, oxyfluorfen, and rose bengal exert their effects by causing electrolyte leakage from the treated tissues in a similar manner, except that oxyfluorfen has an apparent lag period for its action on electrolyte leakage increase. All above compounds require preincubation of treated tissues in darkness and subsequent light exposure with a high intensity for their maximal activities. Our results also support that in the presence of light, $\delta$-aminolevulinic acid and oxyfluorfen cause cellular damage through the indirect generation of singlet oxygen from accumulated tetrapyrroles of porphyrin pathway, whereas rose bengal causes cellular damage through the direct generation of singlet oxygen.

  • PDF

A Stud on the Estimation of Leakage and the probing Leakage in the River Bank (하천제방의 누수탐사 및 누수량 평가에 관한 연구)

  • 김경수;조기태
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.213-217
    • /
    • 1999
  • The river bank is one of the most important structure of fluvial hydraulic structure. Because the breaking of river bank is the cause of calamity, the durability and stability of river bank an very important factors. The breaking of river bank is the cause of the overflow of flood and the leakage of river bank. In this study, we investigated the leakage of river bank using the resistivity probing and estimated the volume of leakage using the weighted residual method The study basin of this study is the upstream of Sumji river basin and the factor of river bank is length 300 m and berm 2.0 m and width 4.5 m and height 4 m. We evaluated the leakage of river basin using using the resistivity probing and estimated the leakage volume using the weighted residual method. The result of this study, the leakage of river bank generated at the point of 39~45 m 80~90 m. 218~222 m. 214~250 m and the type of leakage is the rectangle and the polygon. And the leakage volume of this points evaluated 2.7$\times$$10^{-3}$ $\textrm{m}^3$/sec.

  • PDF

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.

Unsteadiness of Tip Leakage Flow in an Axial Compressor (축류 압축기 팁 누설 유동의 비정상 특성에 관한 연구)

  • Hwang, Yoo-Jun;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.1
    • /
    • pp.58-63
    • /
    • 2012
  • Three dimensional unsteady numerical calculations were performed to investigate unsteadiness of the tip leakage flow in an axial compressor. The first stage of the four-stage low-speed research axial compressor was examined. Since this compressor has a relatively large tip clearance, the unsteadiness of the tip leakage flow is induced. Through the results from the unsteady calculations, the process of the induced unsteady tip leakage flow was investigated. It was shown that the leakage flow that occurred at a rotor blade tip clearance affected the pressure distribution on the pressure side near the tip of the adjacent blade, thus caused the fluctuation of the pressure difference between the pressure side and suction side. Consequently, the unsteady tip leakage flow was induced at the adjacent rotor blade. The unsteady feature of the tip leakage flow was changed as the operating point was moved. The interface between the tip leakage flow and the main flow only affected the trailing edge region at the design point whereas the interface influenced up to the leading edge at the low flow rate point. As the flow rate decreased, additionally, it was seen that the vortex size of the tip leakage flow increased and the relatively large length scale disturbance occurred. On the other hand, using frequency analysis, it was shown that the unsteadiness was not associated with the rotor speed and was about 40% of the blade passing frequency. This feature was explained in the rotor relative frame of reference, and the frequency decreased as the flow rate decreased.