• Title/Summary/Keyword: leak size

Search Result 100, Processing Time 0.024 seconds

Optimal Gas Detection System in Cargo Compressor Room of Gas Fueled LNG Carrier (가스추진 LNG 운반선의 가스 압축기실에 설치된 가스검출장치의 최적 배치에 관한 연구)

  • Lee, Sang-Won;Shao, Yude;Lee, Seung-Hun;Lee, Jin-Uk;Jeong, Eun-Seok;Kang, Ho-Keun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.617-626
    • /
    • 2019
  • This study analyzes the optimal location of gas detectors through the gas dispersion in a cargo compressor room of a 174K LNG carrier equipped with high-pressure cargo handling equipment; in addition, we propose a reasonable method for determining the safety regulations specified in the new International Code of the Construction and Equipment of Ships Carrying Liquefied Gases in Bulk (IGC). To conduct an LNG gas dispersion simulation in the cargo compressor room-equipped with an ME-GI engine-of a 174 K LNG carrier, the geometry of the room as well as the equipment and piping, are designed using the same 3D size at a 1-to-1 scale. Scenarios for a gas leak were examined under high pressure of 305 bar and low pressure of 1 bar. The pinhole sizes for high pressure are 4.5, 5.0, and 5.6mm, and for low pressure are 100 and 140 mm. The results demonstrate that the cargo compressor room will not pose a serious risk with respect to the flammable gas concentration as verified by a ventilation assessment for a 5.6 mm pinhole for a high-pressure leak under gas rupture conditions, and a low-pressure leak of 100 and 140 mm with different pinhole sizes. However, it was confirmed that the actual location of the gas detection sensors in a cargo compressor room, according to the new IGC code, should be moved to other points, and an analysis of the virtual monitor points through a computational fluid dynamics (CFD) simulation.

Analysis Characteristic of Non-point source in Petrochemical (석유화학업종에서의 비산배출원 배출 특성 분석)

  • Chiwan, Ku;Seunghyo, An;Byungchol, Ma
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.45-51
    • /
    • 2022
  • Technologies for collecting and treating pollutants from point sources are steadily being developed, but Non-point sources, it is difficult to develop emission treatment technologies and effective emission coefficients. However, since non-point sources make up about 60% of domestic emissions, and first of all, the method of calculating emissions should be reasonable, and the workplace should develop emission reduction technologies based on this. This study suggest the effectiveness and improvement of the emission coefficient currently used for the petrochemical industry with high emissions. The emission characteristics of non-point sources emission were confirmed by analyzing the LDAR (Leak Detection And Repair) data of OO company located in Yeosu, Jeollanam-do over the past five years. As a result, there was no difference in discharge characteristics according to fluid phase, but it was confirmed that there was a difference in the size of the device and the characteristics of each manufacturer. In addition, it was confirmed that the emission coefficient applied in the petrochemical industry was larger than that of the refining industry, and improvement measures were suggested. Through these studies, it is expected that emission coefficients specialized in the petrochemical industry can be applied and that the workplace itself will contribute to the development of technologies that can drastically reduce them.

Cluster Head Chain Routing Protocol suitable for Wireless Sensor Networks in Nuclear Power Plants (원전 무선 센서 네트워크에 적합한 클러스터 헤드 체인 라우팅 프로토콜)

  • Jung, Sungmin
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.2
    • /
    • pp.61-68
    • /
    • 2020
  • Nuclear power plants have a lower cost of power generation, and they are more eco-friendly than other power generation plants. Also, we need to prepare nuclear plant accidents because of their severe damage. In the event of a safety accident, such as a radiation leak, by applying a wireless sensor network to a nuclear power plant, many sensor nodes can be used to monitor radiation and transmit information to an external base station to appropriately respond to the accident. However, applying a wireless sensor network to nuclear power plants requires routing protocols that consider the sensor network size and bypass obstacles such as plant buildings. In general, the hierarchical-based routing protocols are efficient in energy consumption. In this study, we look into the problems that may occur if hierarchical-based routing protocols are applied to nuclear power plants and propose improved routing protocols to solve these problems. Simulation results show that the proposed routing protocol is more effective in energy consumption than the existing LEACH protocol.

Crack Opening Behavior of Perpetrated Crack Under Fatigue Load

  • Nam, Ki-Woo;Ahn, Seok-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.24-31
    • /
    • 2002
  • The leak-before-break (LBB) behaviors of a structural component under high and low fatigue loads are an important problem in nuclear power plants, liquid nitrogen gas tankers and chemical plants. This paper is an experimental study to evaluate the crack opening behavior after penetration for plate and pipe specimens. Crack opening displacement after penetration under low fatigue load could be satisfactorily determined at the center of the plate thickness regardless of the specimen size. In the case of high fatigue load, it is shown that the crack opening displacement at the center of a penetrated crack carl be derived using the gross stress, $\sigma$/sug G/, and the front surface crack length, a$\_$s/, together with the back surface crack length, a$\_$b/.

Sensitivity Analyses of Failure Probability of Pipes in Nuclear Power Plants using PRO-LOCA (PRO-LOCA를 이용한 원전 배관의 파손확률에 대한 민감도 해석)

  • Cho, Young Ki;Kim, Sun Hye;Park, Jai Hak
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.136-142
    • /
    • 2014
  • Recently a new version of PRO-LOCA program was released. Using the program, failure probability of pipes can be evaluated considering fatigue and/or stress corrosion crack growth and the effects of various parameters on the integrity of pipes in nuclear power plants can be evaluated quantitatively. The analysis results can be used to establish an inspection plan and to examine the effects of important parameters in a maintenance plan. In this study, sensitivity analyses were performed using the program for several important parameters including sampling method, initial crack size, number of initial fabrication flaws, operation temperature, inspection interval, operation temperature and nominal applied bending stress. The effect of parameters on the leak and rupture probability of pipes was evaluated due to fatigue or stress corrosion crack growth.

A Study on Structural Analysis of Butterfly Valve Components by Pressure Testing of the Industrial Standard (산업용 표준의 압력시험 방법에 의한 버터플라이 밸브 구성품의 구조해석에 관한 연구)

  • Shin, Myung-Seob;Yoon, Joon-Yong;Park, In-Won;Lee, Seoung-Hwan;Park, Han-Yung;Jung, Seung-Hwa
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.5-9
    • /
    • 2011
  • Butterfly valves are widely used in current industry to control the fluid flow. They are used for both on-off and throttling applications involving large flows at relatively low pressure-drop especially in large size pipelines. In this study, we carried out the structure analysis of the butterfly valve components according to pressure testing of the industrial standard. the numerical simulation was performed by using ANSYS Workbench. The reliability of valve is evaluated under the investigation of the strain rate, the leak test and the durability of the valve.

The Design of Flat Linear Induction Pump for Transferring Reactor Coolant (원자로 냉각재 이송을 위한 평편형 리니어 유도펌프의 설계)

  • Jang, S.M.;Wu, J.S.;Kim, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.10-12
    • /
    • 1998
  • Pumping liquid metal in nuclear power plant application by conventional centrifugal pumps pose difficulties such as bearing wear out at high temperatures and leak proof sealing of the liquid metal. MHD machine is obtained by replacing solid conducting secondary of conventional motors with ionized gas or liquid metal. It is used for reactor cooling pump because of construction simplicity, perfect sealing and easy operation/maintenance MHD pump is complicated because it includes electromagnetic and hydrodynamic phenomena. The principle of MHD Pumps is described in this paper. We design small laboratory size Flat Linear Induction Pump(FLIP) for transferring sodium.

  • PDF

Neural Network Approach to Automated Condition Classification of a Check Valve by Acoustic Emission Signals

  • Lee, Min-Rae;Lee, Joon-Hyun;Song, Bong-Min
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.6
    • /
    • pp.509-519
    • /
    • 2007
  • This paper presents new techniques under development for monitoring the health and vibration of the active components in nuclear power plants, The purpose of this study is to develop an automated system for condition classification of a check valve one of the components being used extensively in a safety system of a nuclear power plant. Acoustic emission testing for a check valve under controlled flow loop conditions was performed to detect and evaluate disc movement for valve failure such as wear and leakage due to foreign object interference in a check valve, It is clearly demonstrated that the evaluation of different types of failure types such as disc wear and check valve leakage were successful by systematically analyzing the characteristics of various AE parameters, It is also shown that the leak size can be determined with an artificial neural network.

A Study on Optimal Ventilation Design for Gas Boxes Installed in Semiconductor Manufacturing Equipment Handling Flammable Liquids (인화성 가스를 취급하는 반도체 제조장비에 설치된 가스박스 최적 환기 설계에 대한 연구)

  • Gyu Sun Cho;Sang Ryung Kim;Won Baek Yang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.63-69
    • /
    • 2023
  • Although Korea is the world's No. 1 semiconductor producing country, most studies are conducted with risk assessment for simple material risks due to the closedness of the site for industrial protection. In terms of industrial safety, a monitoring system such as a gas detector to determine the leakage of hazardous substances has been established, but research on effectively discharging harmful gastritis substances in case of leakage has only recently begun. Semiconductor manufacturing facilities (gas boxes) where a large amount of flammable materials are handled are currently being safety managed by using a gas detector and blocking the air inlet. It is difficult to dilute in a short time in case of leakage of flammable substances. Therefore, in this study, based on various criteria, the size of the duct according to the size of the gas box is determined and the appropriate size of the air inlet is studied to minimize the exhaust performance requirement without exposing hazardous chemicals to the outside in the event of a flammable leak. We want to do an optimal exhaust design.

Effects of Green Tea on Weight Gain, Plasma and Liver Lipids and Lipid Peroxidation in Pair Fed Rats (Pair Fed 흰쥐에 있어서 녹차의 항증체, 지질개선 및 항산화 효과)

  • Kang, Jung-Ae;Chae, In-Sook;Song, Yong-Bo;Kang, Jung-Sook
    • Journal of Nutrition and Health
    • /
    • v.41 no.7
    • /
    • pp.602-611
    • /
    • 2008
  • We compared antiobese, hypocholesterolemic, antiplatelet and antioxidant effect of 10% green tea powder and 3% green tea extract in rats pair fed 5% cholesterol diets. The final body weight was decreased significantly compared with the control (p < 0.05). Plasma and liver total cholesterol were lower in group of green tea powder or extract, but not statistically different. HDL cholesterol was increased significantly in group of green tea powder compared with the control or green tea extract (p < 0.05). Plasma triglyceride was significantly decreased in group of green tea extract compared with green tea powder, and green tea powder compared with the control respectively (p < 0.05). Liver triglyceride was significantly decreased in group of green tea powder or green tea extract compared with the control (p < 0.01). Platelet aggregations in the maximum and initial slope were not different among groups. Hemolysis was significantly lower in group of green tea powder compared with the control (p < 0.05). Plasma TBARS production was decreased in group of green tea extract compared with the control (p < 0.05). Na passive leak in intact cells was not different, but Na leak in AAPH treated cell was significantly decreased in group of green tea powder than the control (p < 0.05). The leak increase (${\Delta}Na$ Leak) after AAPH treatment was significantly decreased in groups of green tea powder and extract compared with the control (p < 0.05). Isotope excretion after $^{14}C$-cholesterol ingestion was significantly increased in group of green tea extract compared with the control or the green tea powder (p < 0.05). Consumption of green tea in powder or extract may give beneficial effects in weight control and plasma lipid profiles, impeding metabolic syndrome. More studies are needed to clarify what component of green tea and what mechanism are involved in antiobese and hypolipedemic actions of green tea.