• Title/Summary/Keyword: lead plate

Search Result 317, Processing Time 0.03 seconds

The Study on the Recovery Process of Zinc Metal from EAF Dust by Chemical Treatment (EAF 분전의 화학적처리에 와한 금속아연의 제조에 관한 연구)

  • Jeong, Rae-Youn;Lee, Jin-Hui
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.208-215
    • /
    • 2010
  • EAF dust which is contained around 30% of zinc, 15% of iron and 3% of lead individually, is chemically treated by ammonium chloride, ammonia water, ammonia gas and carbon dioxide, and also tested and identified the ratios of the recovery of In by applied the variations of particle size, pH and heating temperature as well, in order to getting optimized recovery of the In metal after performing all of those processes. Experimental results showed that the rate of Zn recovery is 97% when the mixture of 1.3 of $NH_4Cl$/EAF is heated to the temperature of $400^{\circ}C$ and leached by water, and 95% recovery of In when ammonia gas and carbon dioxide is added simultaneously and adjust the 9.5 of pH to the same mixture above. For the purpose of remove the impurities in the mixed sample, which is prepared by the two samples, indicated above showing as the ratio of 95% and 97% recovery, in case of applied the cementation process to it, and also by electrolytic process, produced the In plate of 95~97%, and acquired 99-99.5% of In metal ingot finally by applied the heating process at $470{\sim}500^{\circ}C$.

3D-printing Bone Model for Surgical Planning of Corrective Osteotomy for Treatment of Medial Patellar Luxation in a Dog

  • Jeong, Bumsoo;Jung, Jaemin;Park, Jiyoung;Jeong, Seong Mok;Lee, Haebeom
    • Journal of Veterinary Clinics
    • /
    • v.33 no.6
    • /
    • pp.385-388
    • /
    • 2016
  • A 2-year-old, castrated male Chihuahua dog was referred for revision surgery for reluxation of the patella following surgery for medial patellar luxation (MPL) of the left stifle joint. On general inspection, the patient showed bilateral hindlimb weight-bearing lameness. On physical examination, bilateral non-reducible MPL was detected through palpation. Radiographs revealed bone deformities of both hindlimbs. Computed tomography (CT) was applied for a three-dimensional (3D) printing bone model to establish an accurate surgical plan. The bone plate was pre-contoured over the 3D-printing bone model after execution of corrective osteotomy and sterilized prior to use in surgery. Corrective osteotomy was performed through a staged, bilateral procedure. The patient showed improvement of limb function following surgery without reluxation of the patella. The use of 3D-printing bone model for accurate surgical planning of corrective osteotomy appears to be effective in increasing the accuracy of surgery. That may lead to successful surgical outcomes.

치료중 실시간 모니터링을 위한 투과형 빔측정장치 개발

  • Kim, Jae-Hong;Swanepoel, M.W.;Dekock, E.A.;Park, Yeon-Su;Yang, Tae-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.315-315
    • /
    • 2010
  • 양성자 빔을 이용하여 두경부 암 치료를 South Africa의 iTHEMBA에서 시행하고 있다. 200 MeV의 양성자 빔라인으로부터 진공에서 대기로 인출하여 노즐을 통과하여 종양세포에 조사된다. 치료계획에 적합하게 빔에너지와 모양을 변환하고, 빔을 모니터링하는 기계적 장치들이 노즐에 구성된다. 빔라인에는 이온챔버, Steering Magnet, Multi-wire 이온챔버, Range trimmer plates, lead scattering plate, Double-wedge energy degrader, Multi-layer Faraday cup, Range modulator, Range monitor, occluding ring, Shielding collimators, Quadrant and monitor ionization chamber, Treatment collimator, 그리고 Wellhofer dosimetry tank로 구성되어 있다. 총길이는 6.6m이며 노즐 끝에서 환자의 isocenter 까지는 30cm 정도 아래에 위치한다. 상기의 배치를 갖는 시스템의 양성자 scattering system의 성능을 MCNPX v2.5.0 Monte Carlo simulation을 실시하였다. 또한 정확한 선량을 실시간으로 측정하는 방법인 투과형 검출기를 개발하여 치료와 빔 특성을 동시에 수행하는 기술개발연구가 보고되고 있다. 본 연구에서는 Multileaf Faraday Cup (MLPC) 검출기 설계구조와 데이터 측정방법에 관한 연구를 수행하고자 한다. 빔의 전송 방향으로 3개층의 $4{\times}4$ 배열의 구조로 48 channel의 전류값을 측정하여 입자빔의 분포를 실시간으로 관측하고, 측정된 전류는 ADC를 거쳐 치료계획에 의해 선택된 영역의 SOBP를 유지하도록 range modulation propeller를 조절하는 feed-back system을 갖춘 방사선치료빔 실시간 측정장치 개발에 관한 결과를 보고하고자 한다.

  • PDF

Study on Flow Characteristics in an Augmentation Channel of a Direct Drive Turbine for Wave Energy Conversion Using CFD

  • Prasad, Deepak;Kim, Chang-Goo;Choi, Young-Do;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.594-599
    • /
    • 2009
  • Recent developments such as concern over global warming, depletion of fossil fuels and increase in energy demands by the increasing world population has eventually lead to mass production of electricity using renewable sources. Apart from wind and solar, ocean holds tremendous amount of untapped energy in forms such as geothermal vents, tides and waves. The current study looks at generating power using waves and the focus is on the primary energy conversion (first stage conversion) of incoming waves for different models. Observation of flow characteristics and the velocity in the augmentation channel as well as the front guide nozzle are presented in the paper. A numerical wave tank was used to simulate the waves and after obtaining the desired wave properties; the augmentation channel plus the front guide nozzle and rear chamber were integrated to the numerical wave tank. The waves in the numerical wave tank were generated by a piston type wave maker which was located at the wave tank inlet. The inlet which was modeled as a plate wall moved sinusoidally with the general function, x=asin$\omega$t The augmentation channel consisted of a front nozzle, rear nozzle and an internal fluid region representing the turbine housing. The analysis was performed using the commercial CFD code ANSYS-CFX.

  • PDF

Broad Beam Transmission Properties of some Shielding Materials for Use in Diagnostic Radiology (진단영역 넓은 선속 X선 에너지에 대한 차폐물질의 투과 특성)

  • Jeong, Hoi-Woun;Kim, Jung-Min;Lin, Song-Shei
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.23-29
    • /
    • 2004
  • The application of analytical model(Archer et al. 1983) to shielding calculations in diagnostic radiology combined with measurements of the broad beam transmission properties of lead, steel, concrete, and plate glass for x-ray tube potential of 60-140 kVp using an x-ray inverter generator and total initial beam filtration sufficient to provide half-valve layer representative of those found in common practice and required by regulatory agencies. Our transmission measurements and numerical fits to the mathematical model of broad beam transmission(Archer et al. 1983) will assist medical or health physicist faced with the task of designing protective barriers for medical diagnostic x-ray facilities.

  • PDF

A Case of Fatal Strongyloidiasis in a Patient with Chronic Lymphocytic Leukemia and Molecular Characterization of the Isolate

  • Kia, Eshrat Beigom;Rahimi, Hamid Reza;Mirhendi, Hossein;Nilforoushan, Mohammad Reza;Talebi, Ardeshir;Zahabiun, Farzaneh;Kazemzadeh, Hamid;Meamar, Ahmad Reza
    • Parasites, Hosts and Diseases
    • /
    • v.46 no.4
    • /
    • pp.261-263
    • /
    • 2008
  • Strongyloides stercoralis is a human intestinal parasite which may lead to complicated strongyloidiasis in immunocompromised. Here, a case of complicated strongyloidiasis in a patient with chronic lymphocytic leukemia is reported. Presence of numerous S. stercoralis larvae in feces and sputum confirmed the diagnosis of hyperinfection syndrome in this patient. Following recovery of filariform larvae from agar plate culture of the stool, the isolate was characterized for the ITS1 region of ribosomal DNA gene by nested-PCR and sequencing. Albendazole therapy did not have cure effects; and just at the beginning of taking ivermectin, the patient died. The most important clue to prevent such fatal consequences is early diagnosis and proper treatment.

A Comparative Study of Radiographic Images on Normal Anatomical Structures (정상 해부학적 구조물에 대한 X-선 영상의 비교 연구)

  • Choi Heang-Hee;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.283-297
    • /
    • 1999
  • Purpose: To compare radiographic images of Digora/sup (R)/ system and Ektaspeed Plus film obtained from normal adults. Materials and methods: Storage phosphor plate(SPP) was placed in a film holder behind Ektaspeed Plus film package without lead foil. The effect of film on SPP was studied in a separate in vitro experiment. Forty-seven sets of images were prepared for the evaluaton. The regions of interest(ROI) for evaluation were designated at seven sites including normal anatomical structures. The image quality for each ROI was evaluated on enhanced and unenhanced storage phosphor(SP) images and Ektaspeed Plus film. Results: Two film-SPP configurations showed significantly different gray levels at each step of the aluminum step wedge(p<0.05). The contrasts were comparable. Enhanced SP images were significantly superior to unenhaned images and film in all anatomical sturctures(p<0.01). The differences between unenhanced SP images and film were significant(p<0.05) except root canal and cortical bone on alveolar crest. For anatomical items. there were statistically significant difference among five observers(p<0.05). Conclusions: The image quality of enhanced SP images were superior to Ektaspeed Plus film. and Digora system is potentially applicable to clinical diagnosis.

  • PDF

Measurement of MTF in Display image on monitor by SWRF (SWRF를 이용한 전시영상의 MTF 측정)

  • Kim, Chang-Bok;Lee, Kyung-Sup;Kim, Young-Keun;Cho, Su-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11b
    • /
    • pp.15-17
    • /
    • 2004
  • The quality of X -ray image is depending on the acquired signal pattern So far, the MTF(modulation transfer function) of medical image system has been obtained through various kinds of calculationprocesses after using SWRF (A square wave response function method) to print out it into films. In this study, a tool has been developed that can help the actual user who actually creates the medical images measure the MTF of the finaldisplay image very simply by applying Borland C++ builder software as well as LEAD tools software for the SWRF calculation process to analyze the MTF even on the display image. Films have been printed out by this newly developed MTF measuring tool under the same conditions with the ones for the existing tools and also the calculation method has shown no difference with any existing SWRF calculation method. By using this, it was found out that the MTF of the resolving power of the computed radiography(CR) Image plate (IP) that is a conventional X-ray detection system Jar the conventional X-ray purpose was about 10% at the range of 3.00 LP/mm.

  • PDF

Useful effect of a clinical shoe insole, Mubal®, as orthotics

  • Park, Chan-Lee;Go, Ji-Hyun;Han, Na-Ra;Moon, Hong-Hee;Seo, Min-Jun
    • CELLMED
    • /
    • v.5 no.2
    • /
    • pp.10.1-10.3
    • /
    • 2015
  • Arthritis is a major cause of joint pain, stiffness, and subsequent disability which adversely affects quality of life. Seriously, it can lead to long term social and psychological effects including loss of independence, depression, and anxiety. Arthritis is usually treated with joint replacement surgery or medications. However, the artificial joint is temporary and pharmacological measures have side effects, such as addiction or hypersensitivity. Thus, orthotics has been developed to improve arthritis as a nonpharmacological measure. The increased regional load across compartments of articular cartilage is an important factor in the cause of the arthritis. Mubal$^{(R)}$, a clinical shoe insole, has a sliding function to help people to walk straight and realign the body balance. The slide of Mubal$^{(R)}$ reduces the knee joint loading in patients with arthritis. In addition, pumping function of Mubal$^{(R)}$ can mitigate arthritis by stretching the squashed nerves from lumbar to cervical vertebral and actively circulating blood of pelvic limb. In addition, Mubal$^{(R)}$ could help to stimulate the growth plate. Therefore, Mubal$^{(R)}$ can be used for the child with short stature as well as patients with arthritis.

Antinociceptive and Antiinflammatory Effect of a Diterpene Isolated from the Aerial Part of Siegesbeckia pubescens

  • Park, Hee-Juhn
    • Korean Journal of Plant Resources
    • /
    • v.19 no.6
    • /
    • pp.660-664
    • /
    • 2006
  • The aerial part of Siegesbeckia pubescens (Compositae) has been used to treat rheumatoid arthritis and hypertension in the Oriental medicine. This crude drug has been used without process (SP-0) or with three times-process of steaming and drying (SP-3) or the nine times of that process (SP-9). To search for the antinociceptive anti-inflammatory components from this crude drug, activity-directed fractionation was performed on this crude drug. Since the $CHCl_3$ extract was shown to have a more potent effect than other extracts, it was subjected to silica gel & ODS column chromatography to yield two diterpene compounds (1). Compound 1 was structurally identified as ent-16 (H, 17-hydroxykauran-19-oic acid, which were tentatively named siegeskaurolic acid A. A main diterpene, siegeskaurolic acid A was tested for the antiiflammatory antinociceptive effects using both hot plate- and writhing anti-nociceptive assays and carrageenan-induced anti-inflammatory assays in mice and rats. Pretreatment with siegeskaurolic acid A (20 and 30mg/kg) significantly reduced the stretching episodes, action time of mice and carrageenan-induced edema. These results support that siegeskaurolic acid is a main diterpene responsible for antinociceptive and antiiflammatory action of S. pubescens. In addition, the assays on SP-0, SP-3 and SP-9 produced the experimental results that SP-9 had more significant effects than other two crude drugs. These results suggest that the processing on the original plant may lead to the higher pharmacological effect.