• Title/Summary/Keyword: lead measurement

Search Result 718, Processing Time 0.03 seconds

Direct Measurement of Diffusion Length in Mixed Lead-halide Perovskite Films Using Scanning Photocurrent Microscopy

  • Kim, Ahram;Son, Byung Hee;Kim, Hwan Sik;Ahn, Yeong Hwan
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.514-518
    • /
    • 2018
  • Carrier diffusion length in the light-sensitive material is one of the key elements in improving the light-current conversion efficiency of solar-cell devices. In this paper, we measured the carrier diffusion length in lead-halide perovskite ($MAPbI_3$) and mixed lead-halide ($MAPbI_{3-x}Cl_x$) perovskite devices using scanning photocurrent microscopy (SPCM). The SPCM signal decreased as we moved the focused laser spot away from the metal contact. By fitting the data with a simple exponential curve, we extracted the carrier diffusion length of each perovskite film. Importantly, the diffusion length of the mixed-halide perovskite was higher than that of the halide perovskite film by a factor of 3 to 6; this is consistent with the general expectation that the carrier mobility will be higher in the case of the mixed lead-halide perovskites. Finally, the diffusion length was investigated as a function of applied bias for both samples, and analyzed successfully in terms of the drift-diffusion model.

Relationship of between blood lead level and lead related symptoms in low level lead exposure (저농도 연폭로에서 혈중 연농도와 자각증상과의 관계)

  • Hwang, Kyu-Yoon;Ahn, Jae-Eog;Ahn, Kyu-Dong;Lee, Byung-Kook;Kim, Joung-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.2 s.34
    • /
    • pp.181-194
    • /
    • 1991
  • This study intended to obtain an useful information on the prevalence of subjective symptoms, and to clarify the interrelationships between blood lead and lead related symptoms in low level lead exposure. The 93 male workers exposed to lead and 56 male nonexposed workers were examined for their blood lead(PBB), Zinc-protoporphy(ZPP), hemoglobin(HB) and personnal history, and completed 15 questionnaires related to symptoms of lead absorption : also measured lead concentration in air (PBA) in the workplace. The results obtained were as follows ; 1. The means of blood lead (PBB), blood ZPP and hemoglobin (HB) among workers exposed to lead were $26.1{\pm}8.8{\mu}g/dl,\;28.3{\pm}26.0{\mu}g/dl$ and $16.2{\pm}1.2g/dl$ : whereas those of nonexposed workers were $18.7{\pm}5.1{\mu}g/dl,\;20.6{\pm}8.7{\mu}g/dl$ and $17.3{\pm}1.1g/dl$. The means of above three indicies between two groups showed significant difference statistically (p<0.05). 2. The means of blood lead (PBB), blood ZPP and hemoglobin of workers exposed .to different lead concentration in air were as follows : When it was below $25{\mu}g/m^3$, the indices were $24.7{\pm}79,\;26.1{\pm}26.8{\mu}g/dl\;and\;16.4{\pm}1.1g/dl$ respectively : These indices were $27.1{\pm}8.5,\;23.9{\pm}10.92{\mu}g/dl\;and\;16.2{\pm}1.3g/dl$ when the lead concentration in air was $25{\sim}50{\mu}g/m^3$ : and they were $3.4{\pm}9.3,\;42.3{\pm}31.3{\mu}g/dl\;and\;15.5{\pm}1.2g/dl$ when the concentration of lead was above $50{\mu}g/m^3$. Although there were statistical difference in blood lead and hemoglobin among three different lead concentration in air, there was no statistical difference of blood ZPP among the three groups with different exposure levels (p>0.05). 3. The most frequent by complained symptom was 'Generalized weakness and fatigue', and fewest symptom was 'Intermittent pains in abdomen' 4. Only two symptoms out of fifteen symptoms checked by themselves revealed significant difference between exposed and nonexposed groups. These were 'Intermittent pains of abdomen' and 'Joint pain or arthralgia' (p<0.05), No positive correlation was found between the levels of blood lead and symptom groups categorized as gastrointestinal, neuromuscular and constitutional symptoms, 5. Blood lead (r=0.3995) and ZPP (r=0.2837) showed statistically significant correlation with mean lead concentration in air, whereas correlations were not demonstrated between blood lead and lead related symptoms or blood ZPP and lead related symptoms. 6. Blood lead (PBB) and ZPP showed association (r=0.2466) and the equation PBB=23.75+0.0842 ZPP was derived. 7. On stepwise multiple regression, using blood lead level as a dependent variable and ZPP, hemoglobin (HB), age, work duration (WD) and symptom prevalence as a independent variables, only ZPP significantly contributed a lot to blood lead level. 8. While the ZPP measurement was found to be a good indicator in evaluating health effect of lead absorption in low level lead exposure, lead related symptoms were not sensitive enough to evaluate of lead absorption in low level exposure.

  • PDF

Effect of the voltage lead configurations on AC Loss Measurement in a Single Layer High-Tc Superconducting Model Cable (전압리드의 배치가 단층 고온초전도 모델케이블의 교류손실 측정에 미치는 영향)

  • 류경우;정재훈;황시돌;김석환
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.12
    • /
    • pp.670-675
    • /
    • 2002
  • AC loss is an important issue in the design of high-T$_{c}$ superconducting Power cables. The cables consists of a number of Bi-2223 tapes wound on a former. In such cables tapes have different critical current characteristics intrinsically. And they are electrically connected to each other and current leads by soldering. These make loss measurements considerably complex, especially for short samples of laboratory size. Special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work the at losses in a single layer model cable have been experimentally investigated for different contacts and arrangements of voltage leads. The results show that the losses are not dependent on both arrangements and contact positions of the voltage leads. This implies that loss flux is only in a cylindrical conductor section. The measured losses also agree well with those based on a monoblock model and are independent of frequencies. This means that the measured AC loss of the model cable is purely hysteretic in nature.e.

How to Measure Alert Fatigue by Using Physiological Signals?

  • Chae, Jeonghyeun;Kang, Youngcheol
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.760-767
    • /
    • 2022
  • This paper introduces alert fatigue and presents methods to measure alert fatigue by using physiological signals. Alert fatigue is a phenomenon that which an individual is constantly exposed to frequent alarms and becomes desensitized to them. Blind spots are one leading cause of struck-by accidents, which is one most common causes of fatal accidents on construction sites. To reduce such accidents, construction equipment is equipped with an alarm system. However, the frequent alarm is inevitable due to the dynamic nature of construction sites and the situation can lead to alert fatigue. This paper introduces alert fatigue and proposes methods to use physiological signals such as electroencephalography, electrodermal activity, and event-related potential for the measurement of alert fatigue. Specifically, this paper presents how raw data from the physiological sensors measuring such signals can be processed to measure alert fatigue. By comparing the processed physiological data to behavioral data, validity of the measurement is tested. Using preliminary experimental results, this paper validates that physiological signals can be useful to measure alert fatigue. The findings of this study can contribute to investigating alert fatigue, which will lead to lowering the struck-by accidents caused by blind spots.

  • PDF

Scattering Measurement of Syringe Shield Used in PET/CT (PET/CT실에서 사용되는 주사기 차폐체의 산란선 측정)

  • Jang, Dong-Gun;Park, Cheol-Woo;Park, Eun-Tae
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.375-382
    • /
    • 2020
  • PET/CT is a medical equipment that detects 0.511 MeV of gamma rays. The radiation workers are inevitably exposed to ionizing radiation in the process of handling the isotope. Accordingly, PET/CT workers use syringe shields made of lead and tungsten to protect their hands. However, lead and tungsten are known to generate very high scattering particles by interacting with gamma rays. Therefore, in this study, we tried to find out the effect on the scattering particles emitted from the syringe shield. In the experiment, first, the exposure dose to the hand (Rod phantom) was evaluated according to the metal material (lead, tungsten, iron, stainless steel) using Monte Carlo simulation. The exposure dose was compared according to whether or not plastic is attached. Second, the exposure dose of scattering particles was measured using a dosimeter and lead. As a result of the experiment, the shielding rate of plastics using the Monte Carlo simulation showed the largest difference in dose of about 40 % in lead, and the lowest in iron, about 15 %. As a result of the dosimeter test, when the plastic tape was wound on lead, it was found that the reduction rate was about 15 %, 28 %, and 39 % depending on the thickness. Based on the above results, it was found that 0.511 MeV of gamma ray interacts with the shielding tool to emit scattered rays and has a very large effect on radiation exposure. However, it was considered that the scattering particles could be sufficiently removed with plastics with a low atomic number. From now on, when using high-energy radiation, the shielding tool and the skin should not be in direct contact, and should be covered with a material with a low atomic number.

Aluminum, Copper and Lead as Shielding Materials in 6 MeV Electron Therapy (6 MeV 전자선 치료 시 차폐물질로서 알루미늄, 구리, 납)

  • Lee, Seung-Hoon;Cha, Seok-Yong;Lee, Sun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.2
    • /
    • pp.457-466
    • /
    • 2014
  • During irradiation of lesions in cancer treatment with high energy electrons, normal tissue and critical organs are protected by the shielding material. Scattered radiation that generated the shielding materials affect the depth dose and atomic number. Therefore, we want to examine secondary particles and the scattered photons through calculation and its associated analysis, and compare the measurement for the aluminum, copper, and lead shielding substance of which thickness has 95% charge reduction. Dose change rate which effected scattering radiation was found to be +0.88% for material thickness, +0.43% for atomic number, and +19.70%, +15.20%, +12.40% for measurement, +25.00%, +15.10%, +13.70% for calculation on the aluminum, copper, and lead materials of which thickness has 95% charge reduction, respectively, As a result, we found that scattering rate was dependent on thickness than atomic number. In the dose increasing rate, scattered electrons are more important than scattered photon. For the above mentioned reasons, I think that high atomic number materials should be applied to reduce scattered radiation that generated with thickness effect.

Validation of Non-invasive Method for Electrocardiogram Recording in Mouse using Lead II

  • Kim, Myung Jun;Lim, Ji Eun;Oh, Bermseok
    • Biomedical Science Letters
    • /
    • v.21 no.3
    • /
    • pp.135-143
    • /
    • 2015
  • Electrocardiogram measures the electric impulses generated by the heart during its cycle. Recently genome-wide association studies on electrocardiogram traits revealed many relevant genetic loci. Therefore, these findings need to be validated and investigated to determine the underlying mechanisms using mouse models. Invasive radiotelemetry has been widely used to record the electrocardiogram in mice because it has several advantages over non-invasive measurements. However, radiotelemetry is expensive and requires complicated surgery. On the other hand, a non-invasive method using 3 electrodes (one for earth) for lead II is easy to establish and allows for rapid measurement. In this study, eleven mice were measured with this non-invasive method and no statistical difference among them was found in any ECG measurements. In addition, repeat measurement in the same mouse was performed in 9 sets of experiment and the results indicated that non-invasive method was reliable for reproducibility. Further it was shown that measurements for 1, 5, 10, and 15 minutes were not different so that a short recording such as 5 minutes was enough to estimate the ECG values including heart rate. Further this method was validated by measuring the ECG of Balb/c and FVB that were previously shown to differ in ECG values by radiotelemetry. Significant differences were found in heart rate, PR interval and corrected QT interval between these mouse strains. This study partially proved that non-invasive method also could provide the accuracy and reproducibility. Based on these results, the non-invasive ECG recordings of lead II is recommended as a useful method for quick test in mouse model.

Development of Multiple Channel Measurement System for IC Socket (IC 소켓 검사용 다중 채널 측정 시스템 개발)

  • Gang, Sang-Il;Song, Sung-Yong;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.315-321
    • /
    • 2021
  • In this paper, we have developed the multiple channel measurement system for IC Socket Test. The one can test the current-voltage measurements for pitting the several device specification, which analyze the thin current from several ㎂ to 5A with very low resistor mΩ. The increasement of the IC socket channel with lead pitch under 0.25 mm be need to perform several functions, concurrently. The system to perform these functions be designed to integrate several SMU(source measure unit) on board. So, we can reduce the 2 minutes test time per channel point to 40 sec, with daisy chain test method. Using by graphic interface, I-V curve mode and data logging technologies, we can implement the test flow methods and can make economies the time and cost.

Field Measurement and Compensation Method of Column Shortening for SRC Columns in 37-story Residential Building (37층 초고층주상복합건물 SRC기둥의 기둥축소량 현장계측 및 보정법)

  • Song, Hwa-Cheol;Do,e Guen-Young;Cho, Hun-hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.4 s.18
    • /
    • pp.145-152
    • /
    • 2005
  • Long-term axial shortening of the vertical elements of tail buildings results in differential movements between two elements and may lead to the additional moments of connection beam and slab elements, and other secondary effects, such as cracks of partitions or curtain walls. Accurate prediction of time-dependent column shortening is essential for tall buildings from both strength and serviceability aspects. The compensation method is different from reinforced concrete and SRC(Steel Reinforced Concrete) members. The SRC columns are usually compensated according to total differential shortening between two vertical elements. In this study, column shortenings of 37-story W building under construction are predicted and compensated. The SRC column shortenings are compared with the actual column shortening by field measurement and the column shortenings are reanalysed and recompensated.