• 제목/요약/키워드: layered structure

검색결과 1,140건 처리시간 0.023초

직사각형 MEMS 판 구조의 리츠 해석 (I);수식화 및 수치해법 (Ritz Analysis of Rectangular MEMS Structures (I);Formulation and Its Implementation)

  • 김은석;이병채
    • 대한기계학회논문집A
    • /
    • 제24권2호
    • /
    • pp.421-430
    • /
    • 2000
  • We apply the Rayleigh Ritz method to analyze multi-layered plates with residual stresses. The method is very simple, straight forward, and easily programmable, but it should be applied to structure s only in simple shapes. We derive coupled variational equations based on the principle of virtual displacement, and investigate what kind of basis functions is desirable for the analysis of rectangular plates with various boundary conditions. We demonstrate the effectiveness and usefulness of the method through several examples. The analysis results obtained with the method are in good agreement with those available in literature. A multi-layered MEMS plate example shows that the coupling effect should not be ignored and that residual stresses do influence the stiffness of the structure very much.

혼합가스 분위기 중에서 공업용 순 타이타늄의 고온산화 거동 (High-Temperature Oxidation Behavior of Commercial Pure Titanium in Mixed Gases)

  • 박성호;안용식
    • 동력기계공학회지
    • /
    • 제11권2호
    • /
    • pp.44-50
    • /
    • 2007
  • The oxidation behavior of commercial pure titanium is investigated in the temperature range of $727^{\circ}C{\sim}950^{\circ}C$ in mixed gases. The weight change is measured by TGA during oxidation in mixed gases. The oxidation behavior indicated by weight gain or the growth of oxide layer is based on the linear rate law at high temperatures. The structure of the oxide scale formed during oxidation is analysed by optical microscopy, electron probe microanalyzer, scanning electron microscope and x-ray diffraction. Oxide scales have a $TiO_2$ structure, and are constituted with multi-layered or two layered porous external one and a dense internal one. Ti-O solid solution region is formed at the interface of metal and scale layer. The formation of oxide scale is influenced by the oxidation temperature, time, crystal structure and the condition of atmosphere.

  • PDF

Preparation and Cyclic Performance of Li1.2(Fe0.16Mn0.32Ni0.32)O2 Layered Cathode Material by the Mixed Hydroxide Method

  • Karthikeyan, K.;Nam, K.W.;Hu, E.Y.;Yang, X.Q.;Lee, Y.S.
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권7호
    • /
    • pp.1995-2000
    • /
    • 2013
  • Layered $Li_{1.2}(Fe_{0.16}Mn_{0.32}Ni_{0.32})O_2$ was prepared by the mixed hydroxide method at various temperatures. Xray diffraction (XRD) pattern shows that this material has a ${\alpha}-NaFeO_2$ layered structure with $R{\bar{3}}m$ space group and that cation mixing is reduced with increasing synthesis temperature. Scanning electron microscopy (SEM) reveals that nano-sized $Li_{1.2}(Fe_{0.16}Mn_{0.32}Ni_{0.32})O_2$ powder has uniform particle size distribution. X-ray absorption near edge structure (XANES) analysis is used to study the local electronic structure changes around the Mn, Fe, and Ni atoms in this material. The sample prepared at $700^{\circ}C$ delivers the highest discharge capacity of 207 $mAhg^{-1}$ between 2-4.5 V at 0.1 $mAcm^{-2}$ with good capacity retention of 80% after 20 cycles.

복층건물의 출입문 개방여부에 따른 화재온도분포 및 독성가스 농도 변화특성에 관한 연구 (A Study on Characteristics of Fire Temperature and Concentration of Toxic Gases while the Door Opening or Closed on Multi-layered Construction)

  • 이정윤;김정훈;김응식;김홍
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.72-77
    • /
    • 2017
  • In S. Korea, recently, building fire accidents of residential accommodations or recreational facilities have taken place more frequently than before. Among various building constructions, Multi-layered structure, such as office-residential complex, are mostly made in S. korea. $O_2$, $CO_2$, CO, $NO_x$, $SO_x$, and HCl, these gases has toxic hazard and harmful for human body. And it is predicted that different concentration of released gases from diesel pool fire with upper and lower layer. Therefore, this study reports the fire characteristics of Multi-layered structure by analyzing the fire behavior and concentration of combustion gases of a experimental compartment via real scale fire experiment, in order to predict risks and secure safety for similar fire accidents.

이방성 층상구조에 대한 전위와 전기장 및 전기비저항탐사 계산 연구 (Forward Calculation of Electric Potential, Electric Field and Resistivity Survey on Anisotropic Layered Half Space)

  • 나성호;김형수
    • 지구물리와물리탐사
    • /
    • 제24권3호
    • /
    • pp.98-112
    • /
    • 2021
  • 임의의 전기 이방성을 갖는 지하 층상 구조에 유입되는 전류에 의한 전위와 전기장의 계산을 위하여, Das (1995)에 의해 연구되었던 해석해 알고리듬을 면밀하게 검토하고 개선하였다. 모든 이론 전개를 단계별로 확인하였으며, 그에 따라 전류 전극에 의한 전위 및 전류를 구하는 컴퓨터 프로그램을 작성하였다. 전위와 전기장의 계산을 통해 이방성 층상구조에 대한 전기 비저항 탐사 겉보기 비저항 변화를 전극 간격과 전극 운영 방향에 따라 계산하였다. 이러한 결과들을 예시로 도시화함으로써 전기적 이방성 매체의 효과를 검토하였다.

Fabrication of Layered Cu-Fe-Cu Structure by Cold Consolidation of Powders using High-pressure Torsion

  • Asghari-Rad, Peyman;Choi, Yeon Taek;Nguyen, Nhung Thi-Cam;Sathiyamoorthi, Praveen;Kim, Hyoung Seop
    • 한국분말재료학회지
    • /
    • 제28권4호
    • /
    • pp.287-292
    • /
    • 2021
  • In this study, the layered structures of immiscible Fe and Cu metals were employed to investigate the interface evolution through solid-state mixing. The pure Fe and Cu powders were cold-consolidated by high-pressure torsion (HPT) to fabricate a layered Cu-Fe-Cu structure. The microstructural evolutions and flow of immiscible Fe and Cu metals were investigated following different iterations of HPT processing. The results indicate that the HPT-processed sample following four iterations showed a sharp chemical boundary between the Fe and Cu layers. In addition, the Cu powders exhibited perfect consolidation through HPT processing. However, the Fe layer contained many microcracks. After 20 iterations of HPT, the shear strain generated by HPT produced interface instability, which caused the initial layered structure to disappear.

도심 산지형 공원 능선부 식생유형에 따른 공기이온 평가 - 충주시 탄금대 공원을 대상으로 - (Evaluation of Air Ion According to the Type of Ridge in Urban Park -Focused on Tangeumdae Park in ChungJu-)

  • 김정호;이상훈;윤용한
    • 한국환경생태학회지
    • /
    • 제33권5호
    • /
    • pp.587-595
    • /
    • 2019
  • 도심 산지형 공원 내 식생유형별 요인이 공기이온에 미치는 영향력을 파악하고자 충주시 탄금대 공원을 대상으로 수행하였다. 측정지점은 능선부 내 수종, 흉고직경, 울폐도, 층위구조에 따라 설정하였으며, 기상요소와 공기이온을 측정하였다. 공기이온 측정결과, 양이온 발생량은 평균 $610.90{\pm}50.27ea/cm^3$, 음이온 발생량은 평균 $723.58{\pm}64.25ea/cm^3$, 이온지수는 $1.19{\pm}0.10$이였다. 식생유형에 따른 분석결과는 다음과 같다. 첫째, 공기이온은 수종, 흉고직경, 층위구조에 따라 차이가 발생하였으며, 통계적으로 유의한 것으로 분석되었다. 둘째, 이온지수와 식생유형과의 관계에서 수종, 흉고직경, 울폐도, 층위구조 모두에서 정의 상관관계로 분석되었으며, 양이온의 경우 수종, 흉고직경, 울폐도와 부의 상관관계, 음이온의 경우 수종, 흉고직경, 울폐도, 층위구조에서 정의 상관관계로 분석되었다. 셋째, 능선부 내 이온지수의 영향요인은 기상요인과 식생유형을 비교한 결과 식생유형의 상관계수가 더 높았으며, 세부적으로는 수종 > 층위구조 > 울폐도 > 흉고직경의 순이었다. 본 연구에서는 능선부를 대상으로 공기이온을 평가한 한계점이 존재한다. 이에 향후 공기이온에 대한 연구에서 지형구조, 식생유형을 모두 고려한 분석이 이루어져야할 것이며, 계절에 따른 변화 비교연구가 필요할 것으로 판단되었다.

3차원 지반-구조물 상호작용해석을 위한 입방형 무한요소 (Cuboidal Infinite Elements for Soil-Structure-Interaction Analysis in Multi-Layered Half-Space)

  • 서춘교;윤정방;김재민
    • 한국전산구조공학회논문집
    • /
    • 제20권1호
    • /
    • pp.39-50
    • /
    • 2007
  • 본 논문은 다중 적층지반상의 지반-구조물 상호작용 해석을 위한 3차원 무한요소를 소개한다. 본 무한요소는 Cartesian 좌표계에서 정식화되었으며, 수평, 수평모서리, 수직, 수직 모서리 그리고 수평 수직 모서리 무한요소로서 총 5개의 무한요소로서 구성된다 적용한 형상함수 내부의 파동함수들은 적층지반의 파동문제를 효과적으로 모사하며 다중파동성분을 포함하고 있다. 본 요소의 성능을 검증하기 위하여 주파수영역에서 여러 가지 예제해석을 수행하였다. 균질 및 적층지반상 강체기초와 묻힌 케이슨 기초의 무차원 동적 거동(compliance & impedance)을 구하였으며, 기연구자들의 값과 비교 검토하였다.

Dynamic analysis of foundations in a layered half-space using a consistent transmitting boundary

  • Lee, Jin Ho;Kim, Jae Kwan;Tassoulas, John L.
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.203-230
    • /
    • 2012
  • This paper presents results for impedance (and compliance) functions and input motions of foundations in a layered half-space computed on the basis of a procedure that combines a consistent transmitting boundary with continued-fraction absorbing boundary conditions which are accurate and effective in modeling wave propagation in various unbounded domains. The effects of obliquely incident seismic waves in a layered half-space are taken into account in the formulation of the transmitting boundary. Using the numerical model, impedance (and compliance) functions and input motions of rigid circular foundations on the surface of or embedded in a homogeneous half-space are computed and compared with available published results for verification of the procedure. Extrapolation methods are proposed to improve the performance in the very-low-frequency range and for the static condition. It is concluded from the applications that accurate analysis of foundation dynamics and soil-structure interaction in a layered half-space can be carried out using the enhanced consistent transmitting boundary and the proposed extrapolations.

수중 세슘 제거를 위한 층상 황화 금속 물질 자성화 연구 (A Study on Magnetization of Layered Metal Sulfide for the Removal of Cesium Ions from Aqueous Solution)

  • 전철민;박지원;류정호;장정윤;조동완
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제28권4호
    • /
    • pp.1-5
    • /
    • 2023
  • In the fabrication of magnetic adsorbent by incorporating iron species on base materials with layered structure, there can be a potential loss of adsorption capacity from the penetration of dissolved iron species into the structure. This work newly synthesized a magnetic adsorbent by incorporating nano magnetite and glucose into layered metal sulfide via hydrothermal treatment, and tested the removal efficiencies of cesium ions (Cs+) by the adsorbents fabricated under different conditions (final temperature and glucose mass ratio). As a result, the optimal fabrication condition was found to be mass ratio of 1 (layered metal sulfide): 0.1 (nano magnetite): 0.4 (glucose) and final temperature of 160℃. As-prepared adsorbent possessed good adsorption ability of Cs+ (54.8 mg/g) without a significant loss of adsorption capacity from attaching glucose and nano magnetite onto the surface.