• Title/Summary/Keyword: lateral wall

Search Result 948, Processing Time 0.025 seconds

Evaluation of the posterior superior alveolar artery canal by cone-beam computed tomography in a sample of the Egyptian population

  • Fayek, Marco Malak;Amer, Maha Eshak;Bakry, Ahmed Mohamed
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.35-40
    • /
    • 2021
  • Purpose: This study was conducted to evaluate the accuracy of cone-beam computed tomography (CBCT) in detecting the posterior superior alveolar(PSA) artery canal in a sample of the Egyptian population. Materials and Methods: CBCT images of 600 maxillary sinuses of patients were examined for the presence or absence of the PSA artery along the lateral wall of the maxillary sinus, and for the diameter and type of the canal in relation to age and sex. The distances from the canal to the alveolar crest and sinus floor were also measured. Each canal was assessed to determine whether it was bifid. Results: The PSA artery canal could be detected in 92.0% of the sinuses. The mean distance from the inferior border of the PSA artery canal to the sinus floor was 8.2±2.2 mm (range, 3.2-13.6 mm) in males and 7.3±2.1 mm (range, 3.0-13.1 mm) in females. The mean distance from the inferior border of the PSA artery canal to the alveolar crest was 18.2±2.7 mm (range, 11.0-23.9 mm) in males and 17.4±2.3 mm (range, 10.8-23.5 mm) in females. The mean diameter of the PSA artery canal was larger in male subjects. The PSA artery canal was bifid in 8.7% of cases. The most frequently observed location of the PSA artery canal was intraosseous(82.2%). Conclusion: CBCT was confirmed to be a valuable tool for evaluation and localization of the PSA artery before maxillary sinus lift surgery to avoid intraoperative bleeding.

Optimization of Fan-Shaped Hole for Gas Turbine Blade on Thin Wall (가스터빈 블레이드의 얇은 벽에서의 팬 형상 홀 최적화)

  • Hyun, Minjoo;Park, Hee Seung;Kim, Taehyun;Song, Ho Seop;Lee, Hee Jae;Cho, Hyung Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.4
    • /
    • pp.71-77
    • /
    • 2021
  • Several cooling techinques have been studied for protecting gas turbine blades from hot gas. In terms of film-cooling techniques, various shapes of film cooling holes have been studied including fan shaped holes, which are used on gas turbine blades. However, owing to increasing demands on smaller gas turbines, a research on film-cooling holes on thin walls is required. This study was conducted at blowing ratios of 1 and 2, using numerical analysis. Through the numerical analysis, the effect of geometrical parameters on the effectiveness of fan-shaped hole film cooling was studied. Moreover, optimization was performed on three geometrical parameters: metering length, lateral expansion angle and forward expansion angle. As a result, we realized that the optimal fan-shaped holes on each blowing ratio were found to have very similar geometry and cooling performance.

Numerical Study of Structural Behavior of Underground Silo Structures for Low-and-Intermediate-level Radioactive Waste Disposal Facility (중저준위 방폐물 처분 사일로 구조물의 구조거동 수치해석 연구)

  • Kim, Sun-Hoon;Kim, Kwang-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.3
    • /
    • pp.183-190
    • /
    • 2022
  • The construction of an underground silo structure was the first stage of erecting the Gyeongju low-and-intermediate-level radioactive waste disposal facility. The facility, completed in 2014, has a scale of 100 000 drums and is currently in operation. The underground silo structure, 25 and 50 m in diameter and height, respectively, consists of cylindrical (for storing waste packages) and dome parts. The dome is divided into lower (connected to the operation tunnel) and upper parts. The wall of the underground silo structure is an approximately 1-m-thick reinforced concrete liner. In this study, finite element analysis was performed for each phase of the construction sequence and operation of the underground silo structure. Two-dimensional axial symmetric finite element analysis was implemented using the SMAP-3D program. Three-dimensional finite element analysis was also performed to examine the reliability of the two-dimensional axial symmetric finite element model. The structural behavior of the underground silo structure was predicted, and its structural safety was examined.

Mitigating the effect of urban layout on torsion of buildings caused by infill walls

  • Noorifard, Azadeh;Tabeshpour, Mohammad Reza;Saradj, Fatemeh Mehdizadeh
    • Earthquakes and Structures
    • /
    • v.23 no.2
    • /
    • pp.151-168
    • /
    • 2022
  • Torsion is one of the most important causes of building collapse during earthquakes. Sometimes, despite the symmetric form of the building, infill walls disturb the symmetry of the lateral resisting system. The purpose of this research is to investigate the effect of urban layout on developing torsion caused by infill walls. For this purpose, a typological study was conducted based on the conditions of perimeter walls on 364 buildings and then 9 cases were selected. The dimensions of the selected buildings are constant and the conditions of the perimeter walls including facades with openings and cantilevered facades are variable. The selected buildings with 60 different layouts of infill walls were analyzed and the behavior of each one was evaluated based on the torsional irregularity criteria of seismic codes. The results of the analyses showed that if the perimeter walls of a building are symmetric, asymmetric interior walls will not be important in developing torsion and effective parameters in symmetry of the perimeter infill walls are the number of walls, area of openings, aspect ratio, and construction details. Finally, architectural solutions to mitigate the torsional effects of infill walls were proposed for buildings with solid infill walls on some sides, for buildings where the perimeter walls of one side are on the cantilevered part, and for buildings where the perimeter walls of two adjacent sides are on the cantilevered part. In three-sided buildings, where two adjacent façades are cantilevered, it is often impossible to use the potential of the infill walls.

Cut-Through versus Cut-Out: No Easy Way to Predict How Single Lag Screw Design Cephalomedullary Nails Used for Intertrochanteric Hip Fractures Will Fail?

  • Garrett W. Esper;Nina D. Fisher;Utkarsh Anil;Abhishek Ganta;Sanjit R. Konda;Kenneth A. Egol
    • Hip & pelvis
    • /
    • v.35 no.3
    • /
    • pp.175-182
    • /
    • 2023
  • Purpose: This study aims to compare patients in whom fixation failure occurred via cut-out (CO) or cut-through (CT) in order to determine patient factors and radiographic parameters that may be predictive of each mechanism. Materials and Methods: This retrospective cohort study includes 18 patients with intertrochanteric (IT) hip fractures (AO/OTA classification 31A1.3) who underwent treatment using a single lag screw design intramedullary nail in whom fixation failure occurred within one year. All patients were reviewed for demographics and radiographic parameters including tip-to-apex distance (TAD), posteromedial calcar continuity, neck-shaft angle, lateral wall thickness, and others. Patients were grouped into cohorts based on the mechanism of failure, either lag screw CO or CT, and a comparison was performed. Results: No differences in demographics, injury details, fracture classifications, or radiographic parameters were observed between CO/CT cohorts. Of note, a similar rate of post-reduction TAD>25 mm (P=0.936) was observed between groups. A higher rate of DEXA (dual energy X-ray absorptiometry) confirmed osteoporosis (25.0% vs. 60.0%) was observed in the CT group, but without significance. Conclusion: The mechanism of CT failure during intramedullary nail fixation of an IT fracture did not show an association with clinical data including patient demographics, reduction accuracy, or radiographic parameters. As reported in previous biomechanical studies, the main predictive factor for patients in whom early failure might occur via the CT effect mechanism may be related to bone quality; however, conduct of larger studies will be required in order to determine whether there is a difference in bone quality.

Deup1 Expression Interferes with Multiciliated Differentiation

  • Miram Shin;Jiyeon Lee;Haeryung Lee;Vijay Kumar;Jaebong Kim;Soochul Park
    • Molecules and Cells
    • /
    • v.46 no.12
    • /
    • pp.746-756
    • /
    • 2023
  • A recent study revealed that the loss of Deup1 expression does not affect either centriole amplification or multicilia formation. Therefore, the deuterosome per se is not a platform for amplification of centrioles. In this study, we examine whether gain-of-function of Deup1 affects the development of multiciliated ependymal cells. Our time-lapse study reveals that deuterosomes with an average diameter of 300 nm have two different fates during ependymal differentiation. In the first instance, deuterosomes are scattered and gradually disappear as cells become multiciliated. In the second instance, deuterosomes self-organize into a larger aggregate, called a deuterosome cluster (DC). Unlike scattered deuterosomes, DCs possess centriole components primarily within their large structure. A characteristic of DC-containing cells is that they tend to become primary ciliated rather than multiciliated. Our in utero electroporation study shows that DCs in ependymal tissue are mostly observed at early postnatal stages, but are scarce at late postnatal stages, suggesting the presence of DC antagonists within the differentiating cells. Importantly, from our bead flow assay, ectopic expression of Deup1 significantly impairs cerebrospinal fluid flow. Furthermore, we show that expression of mouse Deup1 in Xenopus embryos has an inhibitory effect on differentiation of multiciliated cells in the epidermis. Taken together, we conclude that the DC formation of Deup1 in multiciliated cells inhibits production of multiple centrioles.

Numerical analysis on two-phase flow-induced vibrations at different flow regimes in a spiral tube

  • Guangchao Yang;Xiaofei Yu;Yixiong Zhang;Guo Chen;Shanshan Bu;Ke Zhang;Deqi Chen
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1712-1724
    • /
    • 2024
  • Spiral tubes are used in a wide range of applications and it is significant to understand the vibration introduced by two-phase flow in spiral tubes. In this paper, the numerical method is used to study the vibration induced by the gas-liquid two-phase flow in a spiral tube with different flow regimes. The pressure fluctuation characteristics at the pipe wall and the solid vibration response characteristics are obtained. The results show that the motion of small bubbles in bubbly flow leads to small pressure fluctuations with low-frequency broadband (0-50 Hz). The motion of the gas plug in the plug flow causes small amplitude periodic pressure fluctuation with a shortened low-frequency broadband (0-15 Hz) compared to the bubbly flow. The motion of the gas slug in the slug flow causes large periodic fluctuations in pressure with a significant dominant frequency (6-7 Hz). The wavy flow is very stable and has a distinct main frequency (1-2 Hz). The vibration regime in the bubbly flow and wave flow are close to the first-order mode, and the vertical vibrating component is dominant. The plug flow and slug flow excite higher-order vibration modes, and the lateral vibration component plays more important part in the vibration response.

Quantitative Assessment of Myocardial Tissue Velocity in Normal Children with Doppler Tissue Imaging : Reference Values, Growth and Heart Rate Related Change (소아에서 도플러 조직영상을 이용한 최대 심근 속도의 계측 : 정상 추정치 및 성장 및 심박동수에 따른 변화)

  • Kim, Se Young;Hyun, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.8
    • /
    • pp.846-856
    • /
    • 2005
  • Purpose : To measure the peak myocardial tissue velocities and patterns of longitudinal motion of atrioventricular(AV) annuli and assess body weight and heart rates-related changes in normal children. Methods : Using pulsed wave Tissue Doppler Imaging(TDI), we measured peak systolic, early and late diastolic myocardial velocities in 72 normal children at six different sites in apical-4 chamber (A4C) view and at four different sites in apical-2 chamber(A2C) view and compared those values with each other, also observing effects with body weights and heart rates. Longitudinal motions of the AV annuli were measured at three different sites in A4C. Results : There were no significant differences of the TDI parameters between gender, ECHO-machines and among the three Doctors performing TDI. Peak myocardial velocities were significantly higher at the base of the heart than in the mid-ventricular region and in the right lateral ventricular wall than in the left lateral ventricular wall or IVS. The TDI parameters showed no significant correlation with fractional shortening(%). Peak systolic and early diastolic myocardial velocities had no correlation with heart rates, but peak late diastolic velocities and A/E ratio correlated positively with heart rates. Correlations between the TDI parameters and body weight were inconsistent. Absolute longitudinal displacement and % displacement were not differ between gender and not correlated with the TDI parameters. Conclusion : We measured the peak myocardial velocities with TDI and the longitudinal motion of the AV annuli using M-mode echocardiography in normal children. With more large scale evaluation, we may establish reference values in normal children and broaden clinical applicabilities in congenital and acquired heart diseases.

Surgical Approaches to the Middle Cranial Base Tumors (중두개와저 종양에 대한 수술적 치료)

  • Kim, Il Seub;Rha, Hyung Kyun;Lee, Kyung Jin;Cho, Kyung Keun;Park, Sung Chan;Park, Hae Kwan;Cho, Jeung Ki;Kang, Jun Ki;Choi, Chang Rhack
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.9
    • /
    • pp.1079-1085
    • /
    • 2001
  • Objective : We analysed various surgical approaches and surgical results of 28 middle cranial base tumors for the purpose of selecting optimal surgical approach to the middle cranial base tumor. Methods : In this retrospective review, 28 patients, including 16 meningioma, 6 trigeminal neurinoma, 2 pituitary adenoma, 2 craniopharyngioma, 1 facial neurinoma, and 1 metastatic tumor, underwent surgical treatment using skull base technique. Of theses, 16 tumors were mainly confined to middle cranial fossae, 5 tumors with extension into both anterior and middle fossa, and 7 tumors with extension into both middle and posterior fossa. Tumors that confined to the middle cranial fossa or extended into the anterior cranial fossa were operated with modified pterional, orbitozygomatic or Dolen'c approach, and tumors that extended into the posterior cranial fossa were operated with anterior, posterior or combined transpetrosal approach. Completeness of tumor resection, surgical outcome, postoperative complication, and follow up result were studied. Results : Total tumor removal was achieved in 9 tumors of 10 tumors that did not extended to the cavernous sinus, and was achieved in 7 tumors of 8 tumors that extended to the lateral wall of the cavernous sinus. Of 10 tumors that extended to the venous channel of the cavernous sinus, only 2 were removed totally. Surgical outcome was excellent in 14 patients, good in 10, fair in 2 and poor in 2. There were no death in this series. Dumbell type tumor which extended into both middle and posterior fossae showed tendency of poor prognosis as compared with tumors that confined middle cranial fossa and extended into both anterior and middle cranial fossa. Postoperative dysfunctions were trieminal hypesthesia in 3, oculomotor nerve palsy in 2, abducens nerve palsy in 2, hemiparesis in 2, cerebellar sign in 1, facial palsy in 1 and hearing impairment in 1. Conclusion : Based on our findings and a review of the literature, we conclude that, when selecting the surgical approach to the middle cranial fossa tumors, the most important factors to be considered were exact location of the tumor mass and existence of the cavernous sinus invasion by tumor mass. We recommend modified pterional or orbitozygomatic approach in cases with tumors located anterior and middle cranial base, without cavernous sinus invasion. In cases with tumors invading into cavernous sinus, we recommend Dolen'c or orbitozygomatic approach. And in lateral wall mass and the cavernous sinus, it is preferred to approach the tumor extradurally. For the tumor involing with middle fossa and posterior fossa(dumbell type) a combined petrosal approach is necessary. In cases with cavernous sinus invasion and internal carotid artery encasement, we recommend subtotal resection of the tumor and radiation therapy to prevent permanent postoperative sequele.

  • PDF

Comparison of Emergency Tc-99m Sestamibi Myocardial Perfusion SPECT and ECG in the Diagnosis of Acute Myocardial Infarction (급성심근경색증 환자에서 응급으로 시행한 Tc-99m Sestamibi 심근관류 SPECT와 심전도의 비교)

  • Cho, Ihn-Ho;Lee, Hyoung-Woo;Park, Jong-Sun;Won, Kyu-Chang;Do, Jun-Young;Sin, Dong-Gu;Yoon, Kyung-Woo;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.104-111
    • /
    • 1996
  • We did Tc-99m sestamibi myocardial perfusion SPECT in 36 patients with acute myocardial infarction when they arrived at the emergency room. And we compared myocardial perfusion images with ECG findings. Then we obtained the follows. The myocardial infarction by the obstruction of left coronary descending artery and right coronary artery showed a good concordance in the diagnosis and infarction site between myocardial perfusion images and ECG findings. The 7 patients with myocardial infarction by a left circumflex coronary artery showed a perfusion defect in the lateral wall in myocardial perfusion SPECT images. But 4 patients of them showed ST segment elevation, 2 patients showed ST depression and 1 patient showed normal ECG findings. The diagnostic sensitivity of Tc-99m sestamibi myocardial perfusion SPECT was 100% by a qualified analysis. The perfusion defect site in the myocardial perfusion SPECT were corresponded with the infarct related coronary artery in 31 patients which was diagnosed by coronary angiograpy. The size of perfusion defect in the po1ar map was $31{\pm}18%(M{\pm}SD)$, in the myocardial infarction with left anterior descending coronary arery obstruction, $31{\pm}13% (M{\pm}SD)$ in the myocardial infarction with right coronary artery obstruction and $25{\pm}5.9%(M{\pm}SD)$ in the myocardial infarction with left circumflex coronary artery obstruction. We concluded that emergency myocardial perfusion SPECT images are useful in the diagnose of myocardial infarction and it's very useful when we are difficult to diagnose with ECG like as lateral wall infarction or left bundle branch block.

  • PDF