• Title/Summary/Keyword: lateral motion

Search Result 796, Processing Time 0.027 seconds

The impact of head repositioning accuracy and proprioception on cervical stabilization exercise in healthy adults

  • Kang, Kyung Wook;Kang, Dae Won;Kwon, Gu Ye;Kim, Han Byul;Noh, Kyoung Min;Baek, Gi Hyun;Cha, Jin Kwan;Kim, Hyun Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.4 no.1
    • /
    • pp.49-54
    • /
    • 2015
  • Objective: Cervical stabilization exercises are frequently to improve strength and endurance of cervical muscles. The purpose of this study was to identify changes in head repositioning accuracy (HRA) and neck proprioception through cervical stabilization exercises in healthy adults. Design: One group pretest-posttest design. Methods: Thirteen participants with no previous history of neck pain or injury to the cervical spine were recruited. HRA was measured by equipment including laser pointer, helmet, eye patch and marking pens. The distance between the spot where the beam had stopped and the center of the graph paper was measured three times with the averaged value used as the head repositioning accuracy. Neck proprioception was measured by a cervical range of motion device (CROM). Subjects wore the CROM tester and were to look straight ahead while bending his/her neck. Subjects were instructed to perform extension, lateral flexion and rotation, and the values were then measured and recorded. The measurements were performed pre-intervention, and after cervical stabilization exercise. Results: There was no significant difference on HRA after intervention. In addition, there was no significant difference on neck proprioception compared with pre-intervention. Conclusions: The present study did not identify any effect on HRA and neck proprioception of cervical stabilization exercise. Further investigations are required to elucidate this in old aged participants and patients with neck pain.

Gaze Effects on Spatial and Kinematic Characteristics in Pointing to a Remembered Target

  • Ryu, Young-Uk;Kim, Won-Dae;Kim, Hyeong-Dong
    • Physical Therapy Korea
    • /
    • v.13 no.4
    • /
    • pp.23-29
    • /
    • 2006
  • The purpose of the present study was to examine gaze effects on spatial and kinematic characteristics during a pointing task. Subjects were asked to watch and point to an aimed target (2 mm in diameter) displayed on a vertically mounted board. Four gaze conditions were developed as combinations of "seeing-aiming" in terms of the eye movements: Focal-Focal (F-F), Focal-Fixing (F-X), Fixing-Focal (X-F), and Fixing-Fixing (X-X). Both the home target and an aimed target were presented for 1 second and then were disappeared in F-F and X-F. In X-F and X-X, only an aimed target disappeared after 1 second. Subjects were asked to point (with index finger tip) to an aimed target accurately as soon as the aimed target was removed. A significant main effect of gaze was found (p<.01) for normalized movement time. Peripheral retina targets had significantly larger absolute error compared to central retina targets on the x (medio-lateral) and z (superior-inferior) axes (p<.01). A significant undershooting to peripheral retina targets on the x axis was found (p<.01). F-F and X-F had larger peak velocities compared to F-X and X-X (p<.01). F-F and X-F were characterized by more time spent in the deceleration phase compared to F-X and X-X (p<.01). The present study demonstrates that central vision utilizes a form of on-line visual processing to reach to an object, and thus increases spatial accuracy. However, peripheral vision utilizes a relatively off-line visual processing with a dependency on proprioceptive information.

  • PDF

Seismic performance evaluation of Pier-Shafts system with multi-layered soil (다양한 지반층을 갖는 Pier-Shafts 시스템의 내진성능평가)

  • Jang, Sung-Hwan;Nam, Sang-Hyeok;Song, Ha-Won;Kim, Byung-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.69-72
    • /
    • 2008
  • The so-called Pier-Shafts system which consists of the continuous column and shaft is often used to support the highway bridge structure because of advantages in easy construction and low cost. In the earthquake region, the Pier-Shafts system undergoes large displacements and represents a nonlinear behavior under the lateral seismic loading. The soil-pile interaction should be considered for more accurate analysis of the Pier-Shafts system. In this study, a transverse response of a reinforced concrete Pier-Shafts system inside multi-layered soil medium is predicted using a finite element program which adopts an elasto-plastic interface model for the interface behavior between the shaft and the soil. Then, seismic analysis is performed to evaluate the performance of Pier-Shafts system under strong ground motion and their results are verified with experimental data.

  • PDF

Development of the similitude law considering the intensity-dependent variation of natural frequency of pile foundation system (말뚝 기초 고유진동수의 가속도 크기 의존성을 고려한 상사법칙 개발)

  • Choi, Jung-In;Yoo, Min-Teak;Kim, Sung-Yul;Kim, Myoung-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.905-912
    • /
    • 2009
  • 1-g shaking table test is conducted to evaluate the dynamic behavior of a soil-structure system under seismic loading condition. A consistent similitude law between the model and prototype is needed to predict the behavior of the prototype structure, quantitatively. The natural frequency of geomaterial decreases with the increase of shaking intensity because of the non-linear property of the geomaterial. This phenomenon affects the applicability of similitude laws in 1-g shaking table tests. In this study, a simple method is suggested to determine the frequency of the input motions in 1-g tests in order to enhance the applicability of similitude laws. Modified input frequency is calculated using the frequency ratio with consideration of the variation of the natural frequency according to the intensity of input ground acceleration. To verify the applicability of the suggested method, a series of 1-g shaking table tests were performed for three different sizes of model piles having an overburden mass on their heads by varying the acceleration and the frequency of input motion. The acceleration amplification ratio on the overburden mass, the lateral displacement at the pile head and the maximum bending moment along the pile depth were measured. The projected behaviors of the virtual prototype based on the measured values of the model tests, where the input frequencies were calculated by the new method, showed good consistency, verifying the applicability of the suggested method.

  • PDF

Evaluation of the Strength Required in Current Seismic Design Code (현행 내진설계 규준의 수평강도 요구에 대한 평가)

  • 한상환;오영훈;이리형
    • Computational Structural Engineering
    • /
    • v.10 no.4
    • /
    • pp.281-290
    • /
    • 1997
  • Current seismic design code is based on the assumption that the designed structures would be behaved inelastically during a severe earthquake ground motion. For this reason, seismic design forces calculated by seismic codes are much lower than the forces generated by design earthquakes which makes structures responding elastically. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factors known as "response modificaion factor". Because these factors were determined empirically, it is difficult to know how much inelastic behaviors of the structures exhibit. In this study, lateral strength required to maintain target ductility ratio was first calculated from nonlinear dynamic analysis of the single degree of freedom system. At the following step, base shear foeces specified in seismic design code compare with above results. If the base shear force required to maintain target ductility ratio was higher than the code specified one, the lack of required strength should be filled by overstrength and/or redundancy. Therefore, overstrength of moment resisting frame structure will be estimated from the results of push-over analysis.

  • PDF

A study on the Development on the Basic Pattern for Pet Dog's Wear (애견복 원형 개발에 관한 연구)

  • Jung, Hwa-Sook;Moon, Myeng-Ok
    • Fashion & Textile Research Journal
    • /
    • v.8 no.1
    • /
    • pp.99-106
    • /
    • 2006
  • With the growing interest in pet dogs and pet dog's wear I used this study to compare and analyze the pattern used by each supplier and developed a new pattern for pet dogs' wear which is appropriate for pet dogs' body lines and movement. Test subjects were 91 pet dogs in Busan and after comparing 3 patterns from different suppliers, I developed the pattern reflecting pet dogs' body shapes and movement. Results are as follows; 1) As a result of analyzing measurements, it was found that pet dogs motion in walking on four feet, is different from that of people on two feet. For center measurements, their waist to bust length is longer than their waist to back length. The result of analysis shows that bust circumference impacts most other measurement results and it seems that better results are achieved if the bust line is taken into consideration when measuring bust back length, bust front length, neck base circumference, front leg arc, the length between lateral shoulder etc. 2) As a result of comparing suppliers' patterns, it was discovered that each supplier has different sizes for the same patterns and those sizes are not standardized across the board. Even if the same size of pattern was actually used in the production of pet dogs' wear by the individual companies, there were many variations in size for each item. 3) To develop a more standard pattern of pet dogs' wear, I collected and analyzed 3 patterns from each supplier and designed a new pattern, revising it three times. After test-wearing of the experimental pattern and the studied patterns, and comparing and analyzing the results, the studied pattern had similarly better estimation than the experimental one.

Control of wind-induced motion in high-rise buildings with hybrid TM/MR dampers

  • Aly, Aly Mousaad
    • Wind and Structures
    • /
    • v.21 no.5
    • /
    • pp.565-595
    • /
    • 2015
  • In recent years, high-rise buildings received a renewed interest as a means by which technical and economic advantages can be achieved, especially in areas of high population density. Taller and taller buildings are being built worldwide. These types of buildings present an asset and typically are built not to fail under wind loadings. The increase in a building's height results in increased flexibility, which can lead to significant vibrations, especially at top floors. Such oscillations can magnify the overall loads and can be annoying to the top floors' occupants. This paper shows that increased stiffness in high-rise buildings may not be a feasible solution and may not be used for the design for comfort and serviceability. High-rise buildings are unique, and a vibration control system for a certain building may not be suitable for another. Even for the same building, its behavior in the two lateral directions can be different. For this reason, the current study addresses the application of hybrid tuned mass and magneto-rheological (TM/MR) dampers that can work for such types of buildings. The proposed control scheme shows its effectiveness in reducing floors' accelerations for both comfort and serviceability concerns. Also, a dissipative analysis carried out shows that the MR dampers are working within the possible range of optimum performance. In addition, the design loads are dramatically reduced, creating more resilient and sustainable buildings. The purpose of this paper is to stimulate, shape, and communicate ideas for emerging control technologies that are essential for solving wind related problems in high-rise buildings, with the objective to build the more resilient and sustainable infrastructure and to optimally retrofit existing structures.

Effects of Robot-Mediated Gait Training Combined with Virtual Reality System on Muscle Activity: A Case Series Research

  • Heo, Seoyoon;Kim, Mooki;Choi, Wansuk
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.2
    • /
    • pp.2021-2027
    • /
    • 2020
  • Background: Previous robot-mediated gait training has been proven several limitations such as pointless repeated motion training, decreased presence, etc. In this research, adult stroke patients were participated in robot-mediated gait training accompanied with or without virtual reality program. Objectives: Exploring whether the results indicated virtual reality system has contribution to muscle strength and balance ability. Design: A case series research, cross-over trial. Methods: Eleven participants (male 4, female 7) with adults diagnosed as stroke from medical doctor ware engaged. The participants received 2 treatment sessions of identical duration, robot-assisted gait training with virtual reality and robot-assisted gait training with screen-off randomly crossed over include 1-day for each person of wash-out period. The parameter was muscle activity, the researchers assessed sEMG (surface electromyography). Results: The result showed less muscle activities during training in robot-assisted gait training with virtual reality circumstances, and these indicated muscles were gluteus medius muscle, vastus medialis muscle, vastus intermedius and vastus lateralis muscle, semimembranosus muscle, gastrocnemius-lateral head, and soleus muscle (P<.05). Conclusion: In this study, we analyzed the outcome of muscle activity for clinical inference of robot-assisted gait training with virtual reality (VR). Less muscle activity was measured in the treatment accompanied by VR, therefore, a more systematic, in-depth and well-founded level of follow-up research is needed.

New bimaxillary orthognathic surgery planning and model surgery based on the concept of six degrees of freedom

  • Jeon, Jaeho;Kim, Yongdeok;Kim, Jongryoul;Kang, Heejea;Ji, Hyunjin;Son, Woosung
    • The korean journal of orthodontics
    • /
    • v.43 no.1
    • /
    • pp.42-52
    • /
    • 2013
  • The aim of this paper was to propose a new method of bimaxillary orthognathic surgery planning and model surgery based on the concept of 6 degrees of freedom (DOF). A 22-year-old man with Class III malocclusion was referred to our clinic with complaints of facial deformity and chewing difficulty. To correct a prognathic mandible, facial asymmetry, flat occlusal plane angle, labioversion of the maxillary central incisors, and concavity of the facial profile, bimaxillary orthognathic surgery was planned. After preoperative orthodontic treatment, surgical planning based on the concept of 6 DOF was performed on a surgical treatment objective drawing, and a Jeon's model surgery chart (JMSC) was prepared. Model surgery was performed with Jeon's orthognathic surgery simulator (JOSS) using the JMSC, and an interim wafer was fabricated. Le Fort I osteotomy, bilateral sagittal split ramus osteotomy, and malar augmentation were performed. The patient received lateral cephalometric and posteroanterior cephalometric analysis in postretention for 1 year. The follow-up results were determined to be satisfactory, and skeletal relapse did not occur after 1.5 years of surgery. When maxillary and mandibular models are considered as rigid bodies, and their state of motion is described in a quantitative manner based on 6 DOF, sharing of exact information on locational movement in 3-dimensional space is possible. The use of JMSC and JOSS will actualize accurate communication and performance of model surgery among clinicians based on objective measurements.

Distraction Arthroplasty as Treatment for Ankle Osteoarthritis (신연 관절 성형술을 이용한 족근 관절 골관절염의 치료증)

  • Park, Yong-Wook;Kim, Do-Young;Lee, Sang-Soo;Lim, Chang-Kyun;Park, Hyun-Chul
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.2
    • /
    • pp.161-166
    • /
    • 2002
  • Purpose: To evaluate the effectiveness of distraction arthroplasty as treatment for moderate or severe ankle osteoarthritis Materials and Methods: Thirteen patients who underwent distraction arthroplasty using the Ilizarov external fixator were available. We removed osteophytes around the ankle before applying the external fixator. We encourage the patients to do active range of motion exercise and to walk with cruch. Follow-up averaged 15 months (range, 10-31 months). Both the patients' postoperative satisfaction and the radiographic joint space were retrospectively evaluated. Results: The duration from applying the external fixator to remove was 12 weeks. Breakage of the wire applied to the forefoot occurred in 2 cases. All patients satisfied with the postoperative clinical results. The ankle joint space averaged $1.6{\pm}0.2mm$ in pre-operative, $4.2{\pm}0.9mm$ in post-Ilizarov external fixator's removal, and $2.3{\pm}0.3mm$ in last follow-up ankle lateral view. Conclusion: We think that distraction arthroplasty with external fixator is useful operative method for the moderate or severe ankle osteoarthritis.

  • PDF