• Title/Summary/Keyword: lateral liquids

Search Result 7, Processing Time 0.02 seconds

Liquid Vocalization in the Dialectal Varieties of English

  • Lee, Ponghyung
    • Journal of English Language & Literature
    • /
    • v.56 no.6
    • /
    • pp.1191-1210
    • /
    • 2010
  • This article claims that English liquid consonants are characterized by the presence of complex place nodes, regardless of dialectal varieties. The primary difference between rhotic and laterals can be pursued in a phonological sense. The level of subbranching nodes is in charge of the disparities among two types of liquids: the branching immediately below the Coronal node with laterals, while branching at the secondary sublevel with rhotics. In this context, the processes of rhotic deletion and lateral vocalization can be understood as those motivated to get rid of complex place nodes. That is, those processes take place as part of phonological attrition. Next, the onset/coda asymmetry regarding liquids stems from the dispreference of vocoid at the onset position, which is readily accounted for by the series of constraints on the well-formedness on the onset, namely Harmonic Onset. The rationale of gradualness and harmonic improvement proposed by Harmonic Serialism is useful to separate the attested outputs from unattested ones across the whole gamut of English varieties. All in all, the primary benefits of our analysis can be found in the consistence in the explanation for the operations running through the sounds regarded as belonging to liquid consonants, comprising the whole range of rhotic and lateral consonants.

Shear-induced Migration of Brownian Suspension in a Pressure-driven Microchannel Flow

  • Kim Y.W.;Jin S.W.;Kim S.W.;Yoo J.Y.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.84-85
    • /
    • 2004
  • Experimental study was conducted to characterize shear-induced lateral migration of $1.0-{\mu}m-diameter$ Brownian particles flowing through a rectangular microchannel which can be used to deliver small amount of liquids, drugs, biological agents and particles in microfluidic devices. Measurements were obtained by using a mercury lamp with a light of 532-nm wavelength, an inverted epi-fluorescence microscope, and a cooled CCD camera to record particle images. Peclet number was used as a parameter to assess the lateral distribution of the particles at a fixed volume fraction of $0.1\%$. It was shown that as Pe increased, particles were moved toward the centerline of the channel, which is in good agreement with previous studies.

  • PDF

Effects of tube-support parameters on damping of heat exchanger tubes in liquids (튜브지지대 인자가 열교환기 튜브의 감쇠에 미치는 영향)

  • 김범식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.1003-1015
    • /
    • 1988
  • Damping information is required to analyse heat exchangers for flow-induced vibration. The most important energy dissipation mechanisms in heat exchanger tubes are related to the dynamic interaction between tube and support. In liquids, squeeze-film damping is dominat. Simple experiments were carried out of a two-span tube with one intermediate support to investigate the effects of tube-support parameters, such as: tube-support thickness, diametral clearance, tube eccentricity, tube span length, location of tube-support, and nature of dynamic interaction between tube and tube-support. The results show that squeeze-film damping is much larger for lateral-type motion than for rocking-type motion at the support. Eccentricity was found to be very important. Diametral clearance, support thickness and frequency are also very relevant. The effects of these parameters on squeeze-film damping are formulated and proposed in a semi-empirical expression.

An Experimental Study on Characteristics of Droplet Generation by Electrospraying for Highly Viscous Liquids (정전분무에 의한 고점성 액체의 액적 생성 특성에 관한 실험적 연구)

  • Kim, Sang-Su;Gu, Bon-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.604-613
    • /
    • 2002
  • Generation characteristics of electrospray droplets for highly viscous liquid have been investigated by measuring size distributions of droplets emitted from the Taylor cone using glycerol solutions with various conductivities. Because of very small volatility of glycerol, droplet sizes can be measured by an aerodynamic size spectrometer (TSI Aerosizer DSP) with negligible evaporation of droplets. For highly conducting and viscous liquid, the sizes of the droplets electrosprayed from the Taylor cone are found to be relatively insensitive to applied voltages and the electrosprays assisted by the corona discharge call produce monodisperse droplets as long as the corona intensity is not too high. Near the minimum flow rate where a liquid cone is stable, the spray tends to consist of a one -peak monodisperse distribution of drop lets. However, at high flow rates, the spray bifurcates into bimodal distributions, which are consistent with the result of the previous study for less viscous liquids than our liquids. For liquid flow rates (Q) below 1 nl/s, the measured droplet diameters by the aerosizer are in the range of 0.30 to 1.2 ${\mu}{\textrm}{m}$ for the glycerol solutions. The diameters of monodisperse droplets scale approximately with $r^*=Q_$\tau$(Q$\tau$){^1/3}$ where $r^*$ is a characteristic length and $\tau$is the electrical relaxation time of the fluid. However, when compared with several represe ntative scaling laws, the droplet diameters are two to six factors greater than those predicted by the scaling laws. This may be closely related to the combined effect of the much higher viscosity and the electrical charge on the jet breakup of glycerol so solution.

Optimization of Passive Mixer for Enhanced Mixing in a Micro-channel by Using Lattice Bloltzmann Method (격자 볼츠만 방법을 이용한 미소 채널에서의 혼합효율 증가를 위한 수동형 믹서의 최적화)

  • Han Gyu suk;Byun Sung Joon;Yoon Joon Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.5 s.236
    • /
    • pp.707-715
    • /
    • 2005
  • In this work, Scalar Passive code in Lattice Boltzmann Method is employed to simulate two-phase flow of low Reynolds number in a micro-channel. The mixing characteristics in a micro-channel is a function of Peclet number. The mixing length increases with the Peclet number. It is found that with the inclusion of static elements at the channel, rapid mixing of two liquids can be achieved, as shown by the results of computer simulations. The enhancement in mixing performance is thought to be caused by the generation of eddies and by lateral velocity component when the mixture flows past static elements. The results indicate that the size of static element has more effect on the mixing than the number of static element.

The Effect of Audio and Visual Cues on Korean and Japanese EFL Learners' Perception of English Liquids

  • Chung, Hyun-Song
    • English Language & Literature Teaching
    • /
    • v.11 no.2
    • /
    • pp.135-148
    • /
    • 2005
  • This paper investigated the effect of audio and visual cues on Korean and Japanese EFL learners' perception of the lateral/retroflex contrast in English. In a perception experiment, the two English consonants /l/ and /r/ were embedded in initial and medial position in nonsense words in the context of the vowels /i, a, u/. Singletons and clusters were included in the speech material. Audio and video recordings were made using a total of 108 items. The items were presented to Korean and Japanese learners of English in three conditions: audio-alone (A), visual-alone (V) and audio-visual presentation (AV). The results showed that there was no evidence of AV benefit for the perception of the /l/-/r/ contrast for either Korean or Japanese learners of English. Korean listeners showed much better identification rates of the /l/-/r/ contrast than Japanese listeners when presented in audio or audio-visual conditions.

  • PDF

A study of /l/ velarization in American English based on the Buckeye Corpus (벅아이 코퍼스를 이용한 미국 영어의 /l/ 연구개음화 연구)

  • Sa, Jae-Jin
    • Phonetics and Speech Sciences
    • /
    • v.13 no.2
    • /
    • pp.19-25
    • /
    • 2021
  • It has been widely recognized that there are two varieties of lateral liquid /l/, which are light /l/ (a non-velarized allophone) and dark /l/ (a velarized allophone). However, this categorical view has been challenged in recent studies, both on articulatory and acoustic aspects. The purpose of this study is to investigate whether to consider /l/ velarization as a continuum in American English and provide supporting data. A spontaneous American English speech database called the Buckeye Speech Corpus was used for the material. The formant frequencies of /l/ in each syllable position were measured and analyzed statistically. The formant frequencies of /l/ in each syllable position, especially F2 values, were significantly different from each other. The results showed that there were other significantly different varieties of /l/ in American English, which support the continuum view on /l/ velarization. Regarding the effect of the adjacent vowel, the backness of the adjacent vowels was shown to affect the degree of /l/ velarization, regardless of the syllable position of the lateral liquid. This result will help provide a solid ground for the continuum view.