• Title/Summary/Keyword: lateral flow

Search Result 590, Processing Time 0.022 seconds

Finite Element Analysis for Circulation Phenomena in Sudden Expansion of Open Channel (유한요소법을 이용한 개수로단면급확대부의 순환현상해석)

  • 윤태훈;서승원
    • Water for future
    • /
    • v.21 no.1
    • /
    • pp.67-76
    • /
    • 1988
  • Analyzed was the circulation phenomena in the open channel with sudden expansion, by applying the Galerkin's finite element method to the depth-averaged 2-dimensional continuity and momentum equations. Wave tests were done in the simplified channel in order to review the validity of this newly developed model and the computed results were within 0.5% of $L_2$-norm error, and application of this model to the simulation of simplified dam-break gave very close results compared with the analytical solution, thus, it can be concluded that this model is valid and efficient. The main flow in the expanded channel was defined as a new initial condition with given velocity and the flow in the expanded portion was at rest in simulating the circulation, and besides the Neumann's condition the slip boundary condition for lateral wall was found to be proper condition than the no-slip condition. It can be concluded, from the numerical tests in the sudden expension, that the circulating phenomena depend mainly on the convective inertia and the effect of turbulence due to bottom shear and lateral shear is insignificant.

  • PDF

Sap Temperature Distribution of the Xylem and Leaf Water Status of Apple Trees in Relation to Soil Oxygen Diffusion Rates

  • Ro, Hee-Myong
    • Journal of Applied Biological Chemistry
    • /
    • v.43 no.3
    • /
    • pp.170-175
    • /
    • 2000
  • A pot-lysimeter experiment was conducted with 3-year-old 'Tsugaru' apple (Malus domestica Borkh) trees to examine the changes in oxygen diffusion rate (ODR) with lateral flow velocity of water through soil. The influence of lateral water flow velocity on water relations and elemental content in leaf, and sap temperature distribution patterns of the xylem of trees were also determined. Trees were grown under four soil water regimes: (1) fast laterally flowing (FWT, $2.50{\times}10^{-4}cm\;s^{-1}$), (2) slow laterally flowing (SWT, $0.25{\times}10^{-4}cm\;s^{-1}$), and (3) stagnant water table (WLT) at 60-cm, and (4) drip-irrigation at -40 kPa of soil matric potential as a control. The rate of $O_2$ diffusion converged near $2{\times}10^{-3}g\;m^{-2}\;min^{-1}$ for FWT and control soils, but decreased below $1{\times}10^{-3}g\;m^{-2}\;min^{-1}$ 40 days after treatment (DAT) for WLT soils. For SWT soils, however, the ODR at 15 cm below the soil surface was similar to that of control, but at 45 cm below the soil surface, ODR was similar to that of the WLT treatment. Leaf water potential of FWT and SWT plants was similar to that of control plants, but the values for SWT plants declined by 98 DAT. Leaf water potential of WLT plants decreased from -1.86 MPa (9 DAT) to -2.41 MPa (59 DAT) and finally down to -2.70 MPa. The sap temperature measured at 1100-hr was lowest at top and highest at bottom for FWT and control plants, but this pattern of SWT and WLT plants was disturbed from 29 DAT. However, for SWT plants, such thermal disturbance of sap temperature disappeared from 63 DAT.

  • PDF

An Experimental Study of Backwater Effects Caused by Piers in the Covered Reach of Urban Streams (都市河川 覆蓋區間내 橋脚으로 인한 背水影響의 實驗的 硏究)

  • Yoon, Yong-Nam;Ahn, Jae-Hyun;Kim, Jin-Kwan
    • Water for future
    • /
    • v.29 no.3
    • /
    • pp.143-152
    • /
    • 1996
  • The hydraulics of flow within the covered reach of urban streams is very complicated due to the accumulation and interference effect of eddies around the multiple piers supporting the covering slab. An extensive experimental study is done to quantitatively estimate the backwater rise effect caused by various arrays of multiple piers. The factors governing the backwater rise are found out to be the contraction ratio due to the piers, Froude number of the flow, longitudinal pier spacing, and the length of the covered reach. For a single section of lateral pier arrays the effect of contraction ratio and Froude number on the backwater rise is analyzed and a multiple regression equation is derived. The effect of multiple piers, arrayed in both lateral and longitudinal directions, on the backwater rise is analyzed in terms of the contraction ratio, Froude number,longitudinal pier spacing and the total length of the covered reach. A multiple regression equation for the backwater rise estimation is proposed based on the experimental data collected in the present study.

  • PDF

Development of Nucleic Acid Lateral Flow Immunoassay for Rapid and Accurate Detection of Chikungunya Virus in Indonesia

  • Ajie, Mandala;Pascapurnama, Dyshelly Nurkartika;Prodjosoewojo, Susantina;Kusumawardani, Shinta;Djauhari, Hofiya;Handali, Sukwan;Alisjahbana, Bachti;Chaidir, Lidya
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.12
    • /
    • pp.1716-1721
    • /
    • 2021
  • Chikungunya fever is an arboviral disease caused by the Chikungunya virus (CHIKV). The disease has similar clinical manifestations with other acute febrile illnesses which complicates differential diagnosis in low-resource settings. We aimed to develop a rapid test for CHIKV detection based on the nucleic acid lateral flow immunoassay technology. The system consists of a primer set that recognizes the E1 region of the CHIKV genome and test strips in an enclosed cassette which are used to detect amplicons labeled with FITC/biotin. Amplification of the viral genome was done using open-source PCR, a low-cost open-source thermal cycler. Assay performance was evaluated using a panel of RNA isolated from patients' blood with confirmed CHIKV (n = 8) and dengue virus (n = 20) infection. The open-source PCR-NALFIA platform had a limit of detection of 10 RNA copies/ml. The assay had a sensitivity and specificity of 100% (95% CI: 67.56% - 100%) and 100% (95% CI: 83.89% - 100%), respectively, compared to reference standards of any positive virus culture on C6/36 cell lines and/or qRT-PCR. Further evaluation of its performance using a larger sample size may provide important data to extend its usefulness, especially its utilization in the peripheral healthcare facilities with scarce resources and outbreak situations.

Structural Analysis and Safety Assessment for Constricted Bridges (협착교량의 구조해석 및 안전성 평가)

  • Jeong, Jae-Hun;Kim, Moon-Ok;Choi, Hyun-Ho;Kim, Jang-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.33-38
    • /
    • 2022
  • As the intense heat continues, many cases of highway pavement blow up and bridge expansion joints damages have been inspected. Especially, Expansion joint closure of bridges is an important problem that can threat the safety of the bridge structure or reduce long-term durability. This paper proposed a structural analysis method for bridges having expansion joint closure and structural analysis was performed to verify the effects according to bridge types. Analysis bridges were divided into four types: concrete and steel bridges, shallow and piled foundations. To induce the situation of abutments and bridge decks are jammed, the following loads were additionally considered; lateral flow pressure, pavement expansion by alkali-aggregate reaction, creep settlement of backfill. The structural analysis method was verified by comparing the structural analysis results with the actually measured joint gap data. In addition, behavioral analysis due to joint closure was conducted to confirm the change in safety ratio by type of superstructure as the axial force increased.

Numerical Simulation of Triaxial Compression Test Using the GREAT Cell: Hydro-Mechanical Experiment (GREAT 셀을 이용한 삼축압축시험의 수치모사: 수리역학 실험)

  • Dohyun Park;Chan-Hee Park
    • Tunnel and Underground Space
    • /
    • v.33 no.2
    • /
    • pp.83-94
    • /
    • 2023
  • Unlike the conventional triaxial test cells for cylindrical specimens, which impose uniform lateral confining pressures, the GREAT (Geo-Reservoir Experimental Analogue Technology) cell can exert differential radial stresses using eight independently-controlled pairs of lateral loading elements and thereby generate horizontal stress fields with various magnitudes and orientations. In the preceding companion paper, GREAT cell tests were numerically simulated under different mechanical loading conditions and the validity of the numerical model was investigated by comparing experimental and numerical results for circumferential strain. In the present study, we simulated GREAT cell tests for an artificial sample containing a fracture under both mechanical loading and fluid flow conditions. The numerical simulation was carried out by varying the mechanical properties of the fracture surface, which were unknown. The numerical responses (circumferential strains) of the sample were compared with experimental data and a good match was found between the numerical and experimental results under certain mechanical conditions of the fracture surface. Additionally, the effect of fluid flow conditions on the mechanical behavior of the sample was investigated and discussed.

Long-term Behavior Characteristics of Backfilled Ground by EPS (EPS로 뒷채움된 지반의 장기거동특성)

  • Chun, Byung-Sik;Jung, Chang-Hee;Choi, Hui-Rim
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.10
    • /
    • pp.151-161
    • /
    • 2007
  • EPS provides a superb self-sufficient stability. Studies on the process of EPS construction method focus on the inchoate phase of general construction, which is increasingly applied to construction sites throughout the world. Unfortunately, there has been little study on the durability and long-term soil behavior involving EPS materials. In this study, the boring, in-site and laboratory tests were conducted to examine the long-term soil behavior in the back-filling of alternating behind the side to which EPS was applied. And results of finite element analysis considering various test results and the soil behavior data measured during the construction show that EPS construction method is a superb process that relieves the load and consequently reduces the settlement, alleviates the stress on the abutment, and prevents lateral flow.

Are Accuracy Studies for Periprosthetic Joint Infection Diagnosis Inherently Flawed? And What to Do with Schrödinger's Hips? A Prospective Analysis of the Alpha Defensin Lateral-Flow Test in Chronic Painful Hip Arthroplasties

  • Jesse W.P. Kuiper;Steven J. Verberne;Pim W. van Egmond;Karin Slot;Olivier P.P. Temmerman;Constantijn J. Vos
    • Hip & pelvis
    • /
    • v.34 no.4
    • /
    • pp.236-244
    • /
    • 2022
  • Purpose: The most recent diagnostic criteria for periprosthetic joint infection (PJI) include the use of the alpha-defensin (AD) lateral-flow (LF) test, but hip and knee arthroplasties were usually combined in previous studies. This prospective study was designed to examine the accuracy of the AD-LF test for diagnosis of PJI in chronic painful total hip arthroplasties (THA). Materials and Methods: Patients with chronic painful hip arthroplasties were prospectively enrolled between March 2018 and May 2020. Exclusion criteria included acute PJI or an insufficient amount of synovial fluid. The modified Musculoskeletal Infection Society (MSIS) criteria were primarily used for PJI diagnosis. Fifty-seven patients were included in the analysis group. Revision surgery was not performed in 38 patients, for different reasons (clinical group); these patients remain "Schrödinger's hips": in such cases PJI cannot be excluded nor confirmed until you "open the box". Results: The result of the AD-LF test was positive in nine patients and negative in 48 patients. Six patients were diagnosed with PJI. AD-LF sensitivity (MSIS criteria) was 83% (95% confidence interval [CI] 36-100%) and specificity was 92% (95% CI 81-98%). The positive and negative predictive value were 56% and 98%, respectively. Conclusion: The AD test is useful in addition to the existing arsenal of diagnostic tools, and can be helpful in the decision-making process. Not all patients with chronical painful THA will undergo revision surgery. Consequently, in order to determine the reliable diagnostic accuracy of this test, future PJI diagnostic studies should include a second arm of "Schrödinger's hips".

Effect of N2 flow rate on growth and photoluminescence properties of GaN nanorods grown by using molecular beam epitaxy (분자선 에피택시를 이용하여 GaN 나노로드를 성장시 구조 및 광학적인 특성에 미치는 N2의 양의 효과)

  • Park, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.4
    • /
    • pp.298-304
    • /
    • 2007
  • We have studied the effect of $N_2$ flow rate on the structural and optical properties of GaN nanorods grown on (111) Si substrates by radio-frequency plasma-assisted molecular-beam epitaxy. The hexagonal shape nanorods with lateral diameters from 80 to 190 nm with increasing $N_2$ flow rate from 1.1 to 2.0 sccm are obtained. However, the ratio of length (thickness) and compact region increases with increasing $N_2$ flow rate up to 1.7 sccm and then saturate. From the photoluminescence, free exciton transition is clearly observed for GaN nanorods with low $N_2$ flow rate. And the PL peak energies are blue-shifted with decreasing diameter of the GaN nanorods due to size effect. Temperature-dependent photoluminescence spectra for the nanorods with $N_2$ flow rate of 1.7 sccm show an abnormal behavior like "S-shape" with increasing temperature.

Characterization of a Thermal Interface Material with Heat Spreader (전자부품의 방열방향에 따른 접촉열전도 특성)

  • Kim, Jung-Kyun;Nakayama, Wataru;Lee, Sun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.91-98
    • /
    • 2010
  • The increasing of power and processing speed and miniaturization of central processor unit (CPU) used in electronics equipment requires better performing thermal management systems. A typical thermal management package consists of thermal interfaces, heat dissipaters, and external cooling systems. There have been a number of experimental techniques and procedures for estimating thermal conductivity of thin, compressible thermal interface material (TIM). The TIM performance is affected by many factors and thus TIM should be evaluated under specified application conditions. In compact packaging of electronic equipment the chip is interfaced with a thin heat spreader. As the package is made thinner, the coupling between heat flow through TIM and that in the heat spreader becomes stronger. Thus, a TIM characterization system for considering the heat spreader effect is proposed and demonstrated in detail in this paper. The TIM test apparatus developed based on ASTM D-5470 standard for thermal interface resistance measurement of high performance TIM, including the precise measurement of changes in in-situ materials thickness. Thermal impedances are measured and compared for different directions of heat dissipation. The measurement of the TIM under the practical conditions can thus be used as the thermal criteria for the TIM selection.