• Title/Summary/Keyword: lateral distance

Search Result 664, Processing Time 0.026 seconds

A Study on the Installation Method of Delineation System Using Detection Distance and Lateral Position (인지거리와 측방위치를 이용한 시선유도시설의 설치방법에 관한 연구)

  • Jeon, Woo-Hoon;Cho, Hye-Jin
    • International Journal of Highway Engineering
    • /
    • v.9 no.3
    • /
    • pp.29-38
    • /
    • 2007
  • This study investigated the effects of delineation systems on drivers' maneuver and how the effectiveness of delineation system can be further improved according to the road geometry. The experiments were conducted to collect lateral placement data and detection distance data using GPS equipped vehicles. The main results are summarizedas follows. Firstly, installing the delineation facilities on the roads helps drivers to recognize road alignment. Secondly, the detection distance is longer for delineators than for raised pavement marker in tangent section, while there is no difference in curve section. The chevron show the longest detection distance in the curve section, while the raised pavement markers showed no distinctive performance in terms of detection distance and lateral placement. Therefore, we can recommend install delineators in the tangent sections and chevrons in curve sections, based on the analysis results of effects of delineation facilities.

  • PDF

A Novel Sub-Micron Gap Fabrication Technology using Chemical-Mechanical Polishing (CMP) for Lateral Field Emission Device (FED) (측면 전계 방출 소자를 위한 화학적-기계적 연마를 이용한 새로운 미소 간격 제작 기술)

  • Lee, Chun-Seop;Han, Cheol-Hui
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.466-470
    • /
    • 2001
  • We have developed a sub-micron gap fabrication technology using chemical-mechanical polishing (CMP) without /the sub-micron lithography equipments (0.18∼0.25 7m). And it has been applied to a lateral field emission device (FED), in which narrow gap distance is very important for reducing turn-on voltage. As a result, the turn-on voltage (at which the current level is 1 nA) of the fabricated device with the gap distance of 256 nm is as low as 4.0 V, which is the lowest turn-on voltage among lateral FEDs ever reported.

  • PDF

Cadever dissection and Dynamic CT for Vascular Anatomy of Rectus Abdominis Muscle (배곧은근의 혈관 주행에 관한 시신해부 및 컴퓨터단층촬영)

  • Son, Daegu;Park, Byungju;Kim, Jinhan;Choi, Taehyun;Kim, Junhyung;Han, Kihwan
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.663-668
    • /
    • 2008
  • Purpose: Pedicled transverse rectus abdominis myocutaneous(TRAM) flap has been a gold standard for breast reconstruction and one of surgical techniques preferred by many surgeons. The authors examined the course of deep epigastric artery focusing on distance from margins of rectus abdominis to pedicle and location of choke vessels to get minimal muscles during pedicled TRAM flap operation. Methods: Eleven rectus abdominis muscle from nine cadavers were used in this study. Rectus abdominis was separated from the cadavers, deep inferior and superior epigastric artery were isolated and then 8 anatomical landmarks in medial and lateral margins of rectus abdominis were designated. Distance to a pedicle meeting first horizontally was measured and vertical location from umbilicus to choke vessel was determined. In addition, 32 rectus abdominis images of 16 women(average age: 37.2 years old) from 64 channel abdomen dynamic computerized tomography were also examined with the same anatomical landmarks with those of cadavers. Results: Average distance from four landmarks on lateral margin of rectus abdominis to pedicle was 1.9 - 3.4cm and 1.8 - 3.8 cm on medial margin. Choke vessel was located between middle and inferior tendinous intersection in all cases and average distance between two tendinous intersection was 6.7 - 7.0 cm on medial margin and 6.2 cm on lateral margin. Location of inferior tendinous intersection was on umbilicus or superior of it in all cases and its average distance from umbilicus was 1.8 - 5.6 cm on medial margin and 2.7 - 6.2 cm on lateral margin. Conclusion: Distance from medial and lateral margins of rectus abdominis muscle to pedicle was the shortest in inferior tendinous intersection and that was averagely 1.8 cm on medial margin and 1.9 cm in average on lateral margin. All choke vessels were located between middle and inferior tendinous intersection.

A new equation based on PGA to provide sufficient separation distance between two irregular buildings in plan

  • Loghmani, Adel;Mortezaei, Alireza;Hemmati, Ali
    • Earthquakes and Structures
    • /
    • v.18 no.5
    • /
    • pp.543-553
    • /
    • 2020
  • Past earthquakes experience shows that serious damage or collapse of buildings have dramatically accrued when sufficient separation distance has not been provided between two adjacent structures. The majority of past studies related to the pounding topic indicate that obtaining the gap size between two buildings is able to prevent collision and impact hazards during seismic excitations. Considering minimization of building collisions, some relationships have been suggested to determine the separation distance between adjacent buildings. Commonly, peak lateral displacement, fundamental period and natural damping as well as structural height of two adjacent buildings are numerically considered to determine the critical distance. Hence, the aim of present study is to focus on all mentioned parameters and also utilizing the main characteristic of earthquake record i.e. PGA to examine the lateral displacement of irregular structures close to each other and also estimate the sufficient separation distance between them. Increasing and decreasing the separation distance is inherently caused economical problems due to the land ownership from a legal perspective and pounding hazard as well. Therefore, a new equation is proposed to determine the optimum critical distance. The accuracy of the proposed formula is validated by different models and various earthquake records.

Correlation between the asymmetry of the infrasternal angle and trunk side shift distance (명치각의 비대칭 성과 몸통 측 이동 거리 사이의 상관 관계)

  • Jung, Sung-hoon;Choi, Sil-ah;Ha, Sung-min
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.691-694
    • /
    • 2021
  • The malalignment of the trunk causes abnormal stress in a specific area and lead to trunk instability. The purpose of this study was to investigate the correlation between the angle between the infrasternal angle and the trunk side shift distance. The participants in this study 22 subjects were participated. The infrasternal angle and trunk side shift distance were measured using a camera and analyzed using the Image J program. The correlation between the asymmetry of the infrasternal angle and trunk side shift distance was moderate (r=-0.413; p=0.028). According to the asymmetry of the infrasternal angle, it was confirmed that trunk lateral shift appeared in a specific direction. Based on result, it suggests that infrasternal angle and trunk side shift should be considered in the intervention plan of patients with asymmetry of the infrasternal angle.

  • PDF

Lateral Displacement Analysis of Concrete Electric Pole Foundation Grounds (배전용 콘크리트전주 기초지반의 횡방향변위 분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.42-49
    • /
    • 2009
  • The effects of various forces acting on concrete pole are analyzed using finite element method how the forces affect on ground displacement. The soil types, wind load location of anchor block embedded depth of pole, and distance between poles are varied to find out effects on lateral displacement. Anchor block is effective when it is located at 1/4 of embedded depth The displacement is decreases as elastic modulus increases. Concrete reinforcement for loosened ground is necessary for double poles because double poles cause large excavation. When embedded depth ratio decrease, lateral displacement increase as closer to ground surface. Large embedded depth is effective to reduce lateral displacement, and the distance between poles is not much large factor.

Comparison on postural control between abdominal draw-in maneuver and abdominal expansion maneuver in persons with stroke

  • Choi, Ho-Suk;Shim, Yu-Jin;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.113-119
    • /
    • 2016
  • Objective: The effect of abdominal expansion maneuver (AEM) and abdominal draw-in maneuver (ADIM) on postural control in an unsupported position in stroke patients. Design: Randomized controlled trial. Methods: A total of 36 persons with hemiplegic stroke participated in this study. The subjects were randomly divided into an AEM experimental group (n=12), an experimental ADIM group (n=12), and a control group (n=12). We collected the general characteristics of all subjects and the pre-test results before the intervention and after 4 weeks of the intervention. The trunk stabilization training of the ADIM and AEM group were performed 15 minutes a day, 3 times a week for 4 weeks, and general physical therapy was performed 2 times a day, 30 minutes per session, 5 times a week for all three groups. The control group received joint mobilizations, muscle strengthening, endurance strengthening, and gait exercises along with treatment of the central nervous system, such as neuro-developmental treatment, mat, and gait training. The AEM is an inspiratory phase of tidal breathing expanding the lateral lower ribcage in a lateral direction with minimal superior movements of the chest. Then the lower abdomen expands and the navel moves in an anterior-caudal direction. The ADIM is a repeated contraction and relaxation of the anal sphincter during inspiration. The navel pulls the lower abdomen to the direction of the spine without the movement of the trunk and pelvis. Results: Before and after the interventions, medial-lateral axis movement distance, anterior-posterior axis movement distance, sway mean velocity, and sway area 95% was a statistically significant change in all three groups (p<0.05). The post-hoc test showed a significant improvement in medial-lateral axis movement distance, anterior-posterior axis movement distance, sway mean velocity, and sway area in the AEM group compared with the control group, and in the ADIM group compared with the control group (p<0.05). Conclusions: In conclusion, both AEM training and ADIM training are necessary interventions to maintain the independent sitting position according to the characteristics of the patient.

The Usefulness of Magnification of the Heart Shadow in Chest Radiography (흉부 촬영시 심음영 확대에 따른 유용성에 관한 연구)

  • Park, Eun-Gyung;Lee, Kun-Young;Jung, Young-Tae;Dong, Kyung-Rae;Ji, Youn-Sang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.119-125
    • /
    • 2010
  • In order to demonstrate the value of long-distance radiography, we have studied how distance affects images in chest frontal radiography and compared short-distance and long-distance images in chest lateral radiography. Cardiothoracic ratio(CTR %) of 50 patients with no disease in the chest(10 each at the age of 20~60) were evaluated in Supine AP(100 cm), Sitting AP(100 cm), Sitting AP(180 cm), and Erect PA(180 cm). In lateral radiography, we evaluated and compared left lateral radiography(100 cm and 180 cm) of the patients based on the horizontal maximum of the heart. The average value of CTR(%) were 0.48 in Erect PA(180 cm), 0.52 in Supine AP(100 cm), 0.50 in Sitting AP(100 cm), 0.49 in Sitting AP(180 cm), which were Supine AP(100 cm) > Sitting AP(100 cm) > Sitting AP(180 cm) > Erect PA(180 cm). The average value of Maximum transverse diameter of left of the cardiac(MLD), which showed how much axis of spine was slanted to the left, was 90.67 mm in Erect PA(180 cm), 103.92 mm in Supine AP(100 cm), 93.54 mm in Sitting(100 cm), 89.84 mm in Sitting AP(180 cm), 58.11 mm in the minimum value and 118.79 mm in the maximum value. The average value of Maximum transverse diameter of right side of the cardiac(MRD), which suggested how much axis of spine was slanted to the right, was 47.18 mm in Erect PA(180 cm), 48.12 mm in Supine AP(100 cm), 44.98 mm in Sitting AP(180 cm), and the minimum value 26.84 mm and the maximum value 65.30 mm. There was no standard method to calculate; therefore, the horizontal maximum of the heart was used for lateral radiography. The average value was 121.07 mm in 100 cm and 109.76 mm in 180 cm. Sitting AP(180 cm) among the types was closest to C-PA(180 cm). As a result, during C-AP radiography, long-distance radiography lessened shadow of the heart more than that of short distance, Sitting position more than Supine position.

  • PDF

A Study on the Accuracy and Convenience of Imaging Method Using Support Device in Knee Joint Lateral Radiography (슬관절의 측면 방사선 촬영에서 보조기구를 이용한 검사방법의 정확성과 편의성에 대한 연구)

  • Uhm, Soyeong;Cho, Yongkeun;Kang, Sungjin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.253-262
    • /
    • 2017
  • In lateral projection imaging method of knee joint, a method that adjusts the incidence angle of central X-ray toward the head side to $5{\sim}7^{\circ}$ in true lateral position which is existing recommended is called imaging method A, Method of imaging the central X-ray perpendicular to the horizontal plane of the examination table toward the knee is called imaging method B, and a method in which the central X-ray is perpendicularly applied to the joints while the lateral side of the distal tibia is compensated by radiolucent materials is called as method C. After tests each imaging method to classified study subject respectively, the joint space distance and the distance between lateral and medial condyle of femur were measured and compared as the quantitative index from the three imaging methods. In addition, the convenience of each imaging method was confirmed through questionnaires to practician. According to the result of the quantitative index, there is no statistically significant difference in imaging method A and C(p>0.05). However, imaging method B showed a significant difference in both A and C(p<0.05). As a result of evaluating the convenience of the imaging method, imaging method A was relatively assessed lower in all items than imaging methods B and C, and as a small difference, imaging method B is assessed higher than C. In this study suggested new knee joint lateral projection imaging method, by using a simple support device, could describe joint space as not much different as existing recommended method without some complex process, and could increase convenience of the practician in the process of the imaging.

Seismic lateral earth pressure analysis of retaining walls

  • Ismeik, Muhannad;Shaqour, Fathi
    • Geomechanics and Engineering
    • /
    • v.8 no.4
    • /
    • pp.523-540
    • /
    • 2015
  • Based on limit equilibrium principles, this study presents a theoretical derivation of a new analytical formulation for estimating magnitude and lateral earth pressure distribution on a retaining wall subjected to seismic loads. The proposed solution accounts for failure wedge inclination, unit weight and friction angle of backfill soil, wall roughness, and horizontal and vertical seismic ground accelerations. The current analysis predicts a nonlinear lateral earth pressure variation along the wall with and without seismic loads. A parametric study is conducted to examine the influence of various parameters on lateral earth pressure distribution. Findings reveal that lateral earth pressure increases with the increase of horizontal ground acceleration while it decreases with the increase of vertical ground acceleration. Compared to classical theory, the position of resultant lateral earth force is located at a higher distance from wall base which in turn has a direct impact on wall stability and economy. A numerical example is presented to illustrate the computations of lateral earth pressure distribution based on the suggested analytical method.