• Title/Summary/Keyword: lateral direction

Search Result 744, Processing Time 0.031 seconds

Roughness Analysis of Paved Road using Drone LiDAR and Images (드론 라이다와 영상에 의한 포장 노면의 평탄성 분석)

  • Jung, Kap Yong;Park, Joon Kyu
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.1
    • /
    • pp.55-63
    • /
    • 2021
  • The roughness of the road is an important factor directly connected to the ride comfort, and is an evaluation item for functional evaluation and pavement quality management of the road. In this study, data on the road surface were acquired using the latest 3D geospatial information construction technology of ground LiDAR, drone photogrammetry, and drone LiDAR, and the accuracy and roughness of each method were analyzed. As a result of the accuracy evaluation, the average accuracy of terrestrial LiDAR were 0.039m, 0.042m, 0.039m RMSE in X, Y, Z direction, and drone photogrammetry and drone LiDAR represent 0.072~0.076m, 0.060~0.068m RMSE, respectively. In addition, for the roughness analysis, the longitudinal and lateral slopes of the target section were extracted from the 3D geospatial information constructed by each method, and the design values were compared. As a result of roughness analysis, the ground LiDAR showed the same slope as the design value, and the drone photogrammetry and drone LiDAR showed a slight difference from the design value. Research is needed to improve the accuracy of drone photogrammetry and drone LiDAR in measurement fields such as road roughness analysis. If the usability through improved accuracy can be presented in the future, the time required for acquisition can be greatly reduced by utilizing drone photogrammetry and drone LiDAR, so it will be possible to improve related work efficiency.

A Comparison for Cervical Neural Foraminal Area by 3-dimensional CT in Normal Adults (3차원 컴퓨터단층촬영상을 이용한 정상 성인의 경추 신경공 면적 비교)

  • Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.623-627
    • /
    • 2021
  • Cervical foraminal stenosis is a disease in which the nerves that pass from the spinal canal to the limbs are narrowed and the nerves are compressed or damaged. Due to the lack of an imaging method that provides quantitatively stenosis, this study attempted to evaluate the area of the cervical vertebrae by reconstructing a three-dimensional computed tomography image, and to determine the area of the neural foramen in normal adults to calculate the stenosis rate. Using a three-dimensional image processing program, the surrounding bones including the posterior spinous process, lateral process, and lamellar bones of the cervical vertebra were removed so that the neural foramen could be observed well. A region of interest including the neural foraminal area of the three-dimensional image was set using ImageJ, and the number of pixels in the neural foraminal area was measured. The neural foraminal area was calculated by multiplying the number of measured pixels by the pixel size. To measure the largest neural foraminal area, it was measured between 40~50 degrees in the opposite direction and 15~20 degrees toward the head. The average area of the right C2-3 foramen was 44.32 mm2, C3-4 area was 34.69 mm2, C4-5 area was 36.41 mm2, C5-6 area was 35.22 mm2, C6-7 area was 36.03 mm2. The average area of the left C2-3 foramen was 42.71 mm2, C3-4 area was 32.23 mm2, C5-6 area was 34.56 mm2, and C6-7 area was 31.89 mm2. By creating a reference table based on the neural foramen area of normal adults, the stenosis rate of patients with neural foraminal stenosis could be quantitatively calculated. It is expected that this method can be used as basic data for the diagnosis of cervical vertebral foraminal stenosis.

Modeling 2D residence time distributions of pollutants in natural rivers using RAMS+ (RAMS+를 이용한 하천에서 오염물질의 2차원 체류시간 분포 모델링)

  • Kim, Jun Song;Seo, Il Won;Shin, Jaehyun;Jung, Sung Hyun;Yun, Se Hun
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.7
    • /
    • pp.495-507
    • /
    • 2021
  • With the recent industrial development, accidental pollution in riverine environments has frequently occurred. It is thus necessary to simulate pollutant transport and dispersion using water quality models for predicting pollutant residence times. In this study, we conducted a field experiment in a meandering reach of the Sum River, South Korea, to validate the field applicability and prediction accuracy of RAMS+ (River Analysis and Modeling System+), which is a two-dimensional (2D) stream flow/water quality analysis program. As a result of the simulation, the flow analysis model HDM-2Di and the water quality analysis model CTM-2D-TX accurately simulated the 2D flow characteristics, and transport and mixing behaviors of the pollutant tracer, respectively. In particular, CTM-2D-TX adequately reproduced the elongation of the pollutant cloud, caused by the storage effect associated with local low-velocity zones. Furthermore, the transport model effectively simulated the secondary flow-driven lateral mixing at the meander bend via 2D dispersion coefficients. We calculated the residence time for the critical concentration, and it was elucidated that the calculated residence times are spatially heterogeneous, even in the channel-width direction. The findings of this study suggest that the 2D water quality model could be the accidental pollution analysis tool more efficient and accurate than one-dimensional models, which cannot produce the 2D information such as the 2D residence time distribution.

Mutilateralism vs. Bilateralism in Chinese Resource Diplomacy : Comparative Analysis on Chinese Foreign Policy toward Central Asia and Africa (중국 자원외교의 다자주의와 양자주의: 중앙아시아 및 아프리카에 대한 중국 자원외교 비교)

  • Kim, Ki-jung;Chun, Ja-hyun
    • Journal of International Area Studies (JIAS)
    • /
    • v.13 no.1
    • /
    • pp.107-133
    • /
    • 2009
  • International relations in the 21st century is featured by boundless competition among nations to secure sufficient energy resources for achieving economic development. Resource diplomacy, therefore, is competitive in its nature, which is derived from the fact that resources of the globe are limited. Chinese recent economic growth has been possible mainly due to its success in resource diplomacy. The Chinese resource diplomacy has shown two different patterns according to target regions. On the one hand, China has pursued multilateral approach to Central Asia region, by which China aimed to secure energy with joint exploration method in the region. Chinese resource diplomacy toward Africa, on the other hand, has been based on bilateral approach combined with unit-centered economic aid to African nations. This difference in Chinese foreign policy pattern seems to be derived from three factors: namely, Chinese strategic considerations on geopolitical condition, regional security sensitivity, and legacies of Chinese long-time non-alignment diplomacy since the 1950s. Whether China is able to maintain the current pattern of resource diplomacy will be depended on how wisely China pursue its relations with two other global powers: Russia in the Central Asia and the U.S. in Africa. In this regard, the Chinese resource diplomacy is expected to work as determining factor of shaping a pattern of tri-lateral strategic relations among the U.S., Russia, and China. Chinese resource diplomacy thus will determine the future direction of the global politics in terms of strategic arrangement.

Finite element analysis for acoustic and temperature characteristics of a piezoelectric HIFU transducer at 10 MHz (10 MHz용 압전 HIFU 트랜스듀서의 음향 및 온도 특성에 대한 유한요소해석)

  • Jong-Ho Kim;Il-Gok Hong;Ho-Yong Shin;Hyo-Jun Ahn;Jong-In Im
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.116-123
    • /
    • 2023
  • A high intensity focuses ultrasound (HIFU) is one of the emerging technologies in the biomedical field. The piezoelectric HIFU transducer is a device that utilizes the thermal energy generated by high ultrasound energy. Recently an operating frequency of the HIFU transducer is to expand above a 7 MHz. In this study, the acoustic pressures and temperature distributions in the tissue that generated by the HIFU transducer at 10 MHz were calculated with the finite element method. In addition, the pressure focusing characteristics of the device were analyzed. The geometrical variables are the piezomaterial thickness, lens shape, water height, and film thickness. The results shown that the acoustic pressure increased and saturated gradually when the height/radius (HL/RL) ratio of the lens increased. Moreover, the focal area was gradually decreases with HL/RL ratio of the lens. In case of the optimized HIFU transducer, the maximum pressure and temperature were analyzed about 19 MPa and 65℃ respectively. And the -3 dB focused distances in the axial and lateral direction are around 2.3 mm and 0.23 mm respectively.

Seismic Performance Evaluation of Unreinforced and ECC-jacketed Masonry Fences using Shaking Table Test (진동대실험을 사용한 비보강 및 ECC 자켓 보강 조적담장의 내진성능평가)

  • Yonghun Lee;Jinwoo Kim;Jae-Hwan Kim;Tae-Sung Eom;Sang-Hyun Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.182-192
    • /
    • 2023
  • In this study, the efficacy of Engineered Cementitious Composite(ECC) jacket for masonry fences subjected to lateral dynamic load was experimentally verified through a shaking table test, comparing it with the performance of an unreinforced masonry(URM) fence. Firstly, dominant frequencies, modal damping ratios and deformed shapes were identified through an impact hammer test. URM and ECC-strengthened fences with heights of 940mm and 970mm had natural frequencies of 6.4 and 35.3Hz, and first modal damping ratios of 7.0 and 5.3%, respectively. Secondly, a shaking table test was conducted in the out-of-plane direction, applying a historical earthquake, El Centro(1940) scaled from 25 to 300%. For the URM fence, flexural cracking occurred at the interface of brick and mortar joint(i.e., bed joint) at the ground motion scaled to 50%, and out-of-plane overturning failure followed during the subsequent test conducted at the ground motion scaled to 30%. On the other hand, the ECC-jacketed fence showed a robust performance without any crack or damage until the ground motion scaled to 300%. Finally, the base shear forces exerted upon the URM and ECC-jacketed fences by the ground motions scaled to 25~300% were evaluated and compared with the ones calculated according to the design code. In contrast to the collapse risk of the URM fence at the ground motion of 1,000-year return period, the ECC-jacketed fence was estimated to remain safe up to the 4,800-year return period ground motion.

Accuracy of soft tissue Profile change prediction in mandibular set-back surgery patients: a comparison of Quick Ceph Image $Pro^{TM}$ (ver 3.0) and $V-Ceph^{TM}$(ver 3.5) (하악골 후퇴 수술 환자의 연조직 측모 예측의 정확성: Quick Ceph Image $Pro^{TM}$(ver 3.0)와 $V-Ceph^{TM}$(Ver 3.5)의 비교)

  • Kim, Myoung-Kyun;Choi, Yong-Sung;Chung, Song-Woo;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.216-226
    • /
    • 2005
  • The purpose of this study was to test and compare the accuracy and reliability of soft tissue profile predictions generated from two computer software programs (Quick Ceph Image $Pro^{TM}$ (ver 3.0) and $V-Ceph^{TM}$(ver 3.5)) for mandibular set-back surgery. The presurgical and postsurgical lateral cephalograms of 40 patients (20 males and 20 females) were traced on the same acetate paper with the reference taken as the cranial base outline. The presurgical skeletal outlines were digitized onto each computer program and the mandible was moved to mimic the expected surgical procedure with reverence to the mandibular anterior border and lower incisor position of the actual postsurgical skeletal outline. The soft tissue profile was generated and the amount and direction of skeletal movement was calculated with each software. The predicted soft tissue profile was compared to the actual postsurgical soft tissue profile. There were differences between the actual and the predicted surgical soft tissue profile charges in the magnitude and direction, especially the upper lip. lower lip and the soft tissue chin (P<0.05). Quick Ceph had more horizontal measurement errors and thickness errors for the upper lip and lower lip, but V-Ceph had more vertical measurement errors of the lower lip (P<0.05). There was a positive correlation between the prediction errors and the amount of mandibular movements in the vertical position of Sn, the horizontal position of Ls and the upper lip thickness for V-Ceph, and there was a negative correlation in the horizontal position and the thickness of the lower lip for Quick Ceph (P<0.05). However all of the Prediction errors of both imaging softwares were ranged within 3mm, and this was considered to be allowable clinically.

A Kinematic Analysis of Uchi-mata(inner thigh reaping throw) by Kumi-kata types in Judo (유도 맞잡기 타입에 따른 허벅다리걸기의 Kinematic 분석[I])

  • Kim, Eui-Hwan;Cho, Dong-Hee;Kwon, Moon-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.63-87
    • /
    • 2002
  • The purpose of this study was to analyze the kinematic variables when Uchi-mata(inner thigh reaping throw) performing by Kumi-kata(engagement position, basic hold) types A, B(A: grasping part-behind neck lapel, B: chest lapel) in Judo with three dimensional analysis technique DLT method by videography. The subjects were four male judokas who have been training in Yong-In University(YIU), on Korean Representative level and Uchi-mata is their tokui-nage(favorite technique), the throwing form was filmed on two S-VHS 16mm video camera( 30frame/sec. Panasonic). Kinematic variables were temporal, posture, and COG. The data collection was performing by Uchi-mata. Six good trials were collected for each condition (type A, B) among over 10 trials. The mean values and the standard deviation for each variable were obtained and used as basic factors for examining characteristics of Uchi-mata by Kumi-kata types. The results of this analysis were as follows : 1) Temporal variables The total time elapsed(TE) by Uchi-mata of types A, B were 1.45, 1.56 sec. respectively. Types A shorter than B. 2) Posture variables In performing of Uchi-mata, the range of flexion in type A, left elbow was $45^{\circ}$ and B was $89^{\circ}$ from Event 2(E2) to Event 6(E6). Type A and B were quite different in right elbow angle in Event1(E1). Left shoulder angle of type A was extended and type B was flexed in E4. Both types right shoulder angles were showed similar pattern. Also both hip angles(right/left) were showed similar pattern. When type A performed Uchi-mata the knee-angle of supporting foot showed $142^{\circ}$in the 1st stage of kake phase[KP], and extended to $147^{\circ}$in the 2nd stage of KP. And the foot-ankle angle of supporting foot showed $83^{\circ}$in the 1st stage of KP, and extended to $86^{\circ}$in the 2nd stage of KP. moreover, The knee angle of attacking foot showed $126^{\circ}$in the 1st stage of KP, and extended to $132^{\circ}$in the 2nd stage of KP, and the foot-ankle angle of attacking foot showed $106^{\circ}$in the 1st stage of KP, and extended to $121^{\circ}$in the 2nd stage of KP. When type B performed Uchi-mata the knee-angle of supporting foot showed $144^{\circ}$in the 1st stage of KP, and extended to $154^{\circ}$in the 2nd stage of KP. And the foot-ankle angle of supporting foot showed $83^{\circ}$in the 1st stage of KP, and extended to $92^{\circ}$in the 2nd stage of KP. moreover, The knee angle of attacking foot showed $132^{\circ}$in the 1st stage of KP, and extended to $140^{\circ}$in the 2nd stage of KP, and the foot-ankle angle of attacking foot showed $103^{\circ}$in the 1st stage of KP, and extended to $115^{\circ}$in the 2nd stage of KP. During Uchi-mata performing, type A showed pulling pattern and type B showed lift-pulling pattern. As Kumi-kata types, it were different to upper body(elbow, shoulder angle), but mostly similar to lower body(hip, knee, ankle angle) on both types. 3) C. O. G. variables When the subjects performed Uchi-mata, COG of type A, B up and down in vertical aspect was 71cm, 73.8cm in height from the foot in the 2nd stage of KP. As Kumi-kata types, it were different on medial-lateral direction aspect but weren't different in Kuzushi phase on vertical direction aspect.

A study on the perimandibular tissues before and after orthodontic treatment with orthognathic surgery in mandandibular prognathic patients (하악골 전돌자의 악교정 수술을 동반한 교정치료 전후 하악골 주위조직의 변화에 관한 연구)

  • Yang, Byung-Ho;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.261-272
    • /
    • 2000
  • Severe skeletal anteroposterior and vertical discrepancy is difficult to obtain satisfactory result by only orthodontic treatment, and much anteroposterior movement and treatment stability require orthodontic treatment with orthognathic surgery. The treatment goal of mandibular prognathic patients is to promote the function of stomatognathic system including mastication and phonetics, to improve the esthetics of facial profile and to maintain stability. Positional changes of hyoid bone, pharynx and tongue were seen with mandibular movement after orthognathic surgery. This study was performed to observe the changes of perimandibular tissues of orthodontic patients with skeletal mandibular prognathism who treated with orthodontic treatment, and the changes of hyoid bone, pharyx and tongue by relapse or recurrance after before and after orthognathic surgery and retention. The 22 patients who had mandibular prognathism were selected. They treated with orthodontic treatment with sagittal split ramus osteotomy as orthognathic surgery. And lateral cephalometric radiographs were taken 3 times : pre-surgery (T1), immediate post-surgery (T2) and 2 years alter retention (T3). The results were as follows : 1. The hyoid bone returned back after clockwise rotation to maxilla and occlusal plane during retention (P<0.01). 2. The hyoid bone moved posterior-inferiorly by mandibular surgery and returned back anterior-superior after retention. (P<0.01) 3. The changes of pharyngeal depth showed a little decrease at upper area in post- surgery, but it was not a significant difference generally through before, after and retention. 4. In relating to tongue base, the angle of tongue base was decreased and the dorsal area of tongue base moved to inferior-posterior direction and to superior direction again after retention (P<0.01). 5. Related to the thickness of upper and lower lip, the thickness of upper lip decreased after surgery, and the soft tissues below lower lip increased after surgery and decreased after retention.

  • PDF

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.

  • PDF