• 제목/요약/키워드: lateral compression

검색결과 381건 처리시간 0.023초

Axial compressive residual ultimate strength of circular tube after lateral collision

  • Li, Ruoxuan;Yanagihara, Daisuke;Yoshikawa, Takao
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권1호
    • /
    • pp.396-408
    • /
    • 2019
  • The tubes which are applied in jacket platforms as the supporting structure might be collided by supply vessels. Such kind of impact will lead to plastic deformation on tube members. As a result, the ultimate strength of tubes will decrease compared to that of intact ones. In order to make a decision on whether to repair or replace the members, it is crucial to know the residual strength of the tubes. After being damaged by lateral impact, the simply supported tubes will definitely loss a certain extent of load carrying capacity under uniform axial compression. Therefore, in this paper, the relationship between the residual ultimate strength of the damaged circular tube by collision and the energy dissipation due to lateral impact is investigated. The influences of several parameters, such as the length, diameter and thickness of the tube and the impact energy, on the reduction of ultimate strength are investigated. A series of numerical simulations are performed using nonlinear FEA software LS-DYNA. Based on simulation results, a non-dimensional parameter is introduced to represent the degree of damage of various size of tubes after collision impact. By applying this non-dimensional parameter, a simplified formula has been derived to describe the relationship between axial compressive residual ultimate and lateral impact energy and tube parameters. Finally, by comparing with the allowable compressive stress proposed in API rules (RP2A-WSD A P I, 2000), the critical damage of tube due to collision impact to be repaired is proposed.

Fire resistance tests of LSF walls under combined compression and bending actions

  • Peiris, Mithum;Mahendran, Mahen
    • Steel and Composite Structures
    • /
    • 제43권4호
    • /
    • pp.483-500
    • /
    • 2022
  • Cold-formed steel wall panels sheathed with gypsum plasterboard have shown superior thermal and structural performance in fire. Recent damage caused by fire events in Australia has increased the need for accurate fire resistance ratings of wall systems used in low- and mid-rise construction. Past fire research has mostly focused on light gauge steel framed (LSF) walls under uniform axial compression and LSF floors under pure bending. However, in reality, LSF wall studs may be subject to both compression and bending actions due to eccentric loading at the wall to-roof or wall-to-floor connections. In order to investigate the fire resistance of LSF walls under the effects of these loading eccentricities, four full-scale standard fire tests were conducted on 3 m × 3 m LSF wall specimens lined with two 16 mm gypsum plasterboards under different combinations of axial compression and lateral load ratios. The findings show that the loading eccentricity can adversely affect the fire resistance level of the LSF wall depending on the magnitude of the eccentricity, the resultant compressive stresses in the hot and cold flanges of the wall studs caused by combined loading and the temperatures of the hot and cold flanges of the studs. Structural fire designers should consider the effects of loading eccentricity in the design of LSF walls to eliminate their potential failures in fire.

Comparison of Turkish Steel Building Specifications, TS 648 and SDCCSS 2018

  • Bozkurt, Mehmet Bakir;Ergut, Abdulkerim;Ozkilic, Yasin Onuralp
    • Steel and Composite Structures
    • /
    • 제45권4호
    • /
    • pp.513-533
    • /
    • 2022
  • This study presents similarities and differences between Turkish Building Code for Steel Structures, which are TS 648 and SDCCSS (Specification for Design, Calculation and Construction of Steel Structures) in terms of the design of the members. Hot-rolled I-shaped steel sections for symmetrical and U-shaped steel sections (i.e., channels) for monosymmetric sections were elaborated in detail. The design strength of tension members under tensile load, compression members under axial load and flexural members under flexure and shear were examined separately. Connection details for tension members, slenderness for compression members and distance between lateral supports for flexural members were considered as prime variables. Analysis results revealed the design strength of the tension members where at least one of the cross-sectional parts is not connected to the connection plates, I-shaped compression members where a slenderness ratio is below 39 (𝛌<39), U-shaped compression members and flexural members where Lb is between Lp and Lr (Lpb≤Lr) designed based on TS 648 are greater than those designed based on SDCCSS 2018. Strength differences between the specification can reach 79% for tensile members, 13% for compression members and 9% for flexural members.

Mid-length lateral deflection of cyclically-loaded braces

  • Sheehan, Therese;Chan, Tak-Ming;Lam, Dennis
    • Steel and Composite Structures
    • /
    • 제18권6호
    • /
    • pp.1569-1582
    • /
    • 2015
  • This study explores the lateral deflections of diagonal braces in concentrically-braced earthquake-resisting frames. The performance of this widely-used system is often compromised by the flexural buckling of slender braces in compression. In addition to reducing the compressive resistance, buckling may also cause these members to undergo sizeable lateral deflections which could damage surrounding structural components. Different approaches have been used in the past to predict the mid-length lateral deflections of cyclically loaded steel braces based on their theoretical deformed geometry or by using experimental data. Expressions have been proposed relating the mid-length lateral deflection to the axial displacement ductility of the member. Recent experiments were conducted on hollow and concrete-filled circular hollow section (CHS) braces of different lengths under cyclic loading. Very slender, concrete-filled tubular braces exhibited a highly ductile response, undergoing large axial displacements prior to failure. The presence of concrete infill did not influence the magnitude of lateral deflection in relation to the axial displacement, but did increase the number of cycles endured and the maximum axial displacement achieved. The corresponding lateral deflections exceeded the deflections observed in the majority of the previous experiments that were considered. Consequently, predictive expressions from previous research did not accurately predict the mid-height lateral deflections of these CHS members. Mid-length lateral deflections were found to be influenced by the member non-dimensional slenderness (${\bar{\lambda}}$) and hence a new expression was proposed for the lateral deflection in terms of member slenderness and axial displacement ductility.

Efficiency of stiffening plates in fabricated concrete-filled tubes under monotonic compression

  • Albareda-Valls, Albert;Carreras, Jordi Maristany
    • Steel and Composite Structures
    • /
    • 제18권4호
    • /
    • pp.1023-1044
    • /
    • 2015
  • Concrete-filled tubes (CFT), formed by an outer steel tube filled with plain or reinforced concrete inside, have been increasingly used these recent decades as columns or beam-columns, especially for tall buildings in seismic areas due to their excellent structural response. This improved behavior is derived from the effect of confinement provided by the tube, since the compressive strength of concrete increases when being subjected to hydrostatic pressure. In circular CFTs under compression, the whole tube is uniformly tensioned due to the radial expansion of concrete. Contrarily, in rectangular and square-shaped CFTs, the lateral flanges become subjected to in-plane bending derived from this volumetric expansion, and this fact implies a reduction of the confinement effect of the core. This study presents a numerical analysis of different configurations of CFT stub columns with inner stiffening plates, limited to the study of the influence of these plates on the compressive behavior without eccentricity. The final purpose is to evaluate the efficiency in terms of strength and ductility of introducing stiffeners into circular and square CFT sections under large deformation axial loading.

Experimental study on shear behavior of I-girder with concrete-filled tubular flange and corrugated web

  • Shao, Y.B.;Wang, Y.M.
    • Steel and Composite Structures
    • /
    • 제22권6호
    • /
    • pp.1465-1486
    • /
    • 2016
  • Conventional plate I-girders are sensitive to local buckling of the web when they are subjected mainly to shear action because the slenderness of the web in out-of-plane direction is much bigger. The local buckling of the web can also cause the distorsion of the plate flange under compression as a thin-walled plate has very low torsional stiffness due to its open section. A new I-girder consisted of corrugated web, a concrete-filled rectangular tubular flange under compression and a plate flange under tension is presented to improve its resistance to local buckling of the web and distorsion of the flat plate flange under compression. Experimental tests on a conventional plate I-girder and a new presented I-girder are conducted to study the failure process and the failure mechanisms of the two specimens. Strain developments at some critical positions, load-lateral displacement curves, and load-deflection curves of the two specimens have all be measured and analyzed. Based on these results, the failure mechanisms of the two kinds of I-girders are discussed.

횡하중을 고려한 선체보강판넬의 압축 붕괴거동에 관한 연구 (Axial Collapse Behaviour of Ship's Stiffened Panels considering Lateral Pressure Load)

  • 고재용;박주신
    • 한국항해항만학회지
    • /
    • 제31권3호
    • /
    • pp.235-245
    • /
    • 2007
  • 선체의 갑판부와 선저부 그리고 해양구조물의 기본적인 구조는 보강판이다. 보강판넬은 한쪽방향으로 위치한 보강재 혹은 종/횡 방향으로 복잡하게 위치한 구조를 이루고 있으며, 후자의 모델을 그릴리지 구조라고 부른다 선체구조설계 단계에서 선박의 종강도 평가는 가장 중요한 항목이다. 일반적으로, 극심한 해상상태에 놓인 선박의 선저부에는 호깅조건에 의해 발생되는 횡모멘트에 기인하여 압축하중이 작용하게 되며, 이와 동시에 수압하중 작용으로 인한 국부휭모멘트가 작용된다. 본 논문에서는, 구조해석 결과의 검증을 위해서 여러 가지 해석프로그램 및 현재 사용되고 있는 선급룰과의 비교를 하여 횡하중의 영향에 따른 압축최종강도에 대해 분석하고, 여러 가지 설계변수를 변화하여, 각각의 영향을 검토하고, 최종적으로 조합하중 조건에서의 횡하중의 영향에 대해서 분석하였다. 본 연구에서 얻어진 결과들은 최종한계상태설계법에 기반을 두고, 조합하중이 작용하는 선체보강판의 구조강도 거동에 대해서 하중성분에 대한 관계를 고찰하였다.

Mini-partial lateral corpectomy and hemilaminectomy for the treatment of heavily protruded thoracolumbar intervertebral disc in small dogs

  • Han, Hyun-Jung;Yoon, Hun-Young
    • 대한수의학회지
    • /
    • 제59권4호
    • /
    • pp.213-217
    • /
    • 2019
  • Five paraplegic dogs were diagnosed with thoracolumbar intervertebral disc disease with more than 50% compression of spinal cord. Because the lesions were determined to be disc extrusion on magnetic resonance imaging, a hemilaminectomy was initially performed, however, protruded discs were confirmed during surgery. To remove the protruded disc, modified partial lateral corpectomy (mini-PLC) was additionally performed. All dogs recovered to full ambulation within a median of 44 days without temporary deterioration or vertebral instability. Mini-PLC as described here enables successful removal of the protruded disc, while preserving vertebral stability in dogs for whom the use of hemilaminectomy is inevitable.

Management of Traumatic C6-7 Spondyloptosis with Cord Compression

  • Choi, Man-Kyu;Jo, Dae-Jean;Kim, Min-Ki;Kim, Tae-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권5호
    • /
    • pp.289-292
    • /
    • 2014
  • A case of total spondyloptosis of the cervical spine at C6-7 level with cord compression is described in a 51-year-old male. Because the bodies of C6 and 7 were tightly locked together, cervical traction failed. Then the patient was operated on by a posterior approach. Posterior stabilization and fusion were performed by C4-5 lateral mass and C7-T1 pedicle screw fixation and rod instrumentation with bridging both C4-5's rods to the C7-T1's extended ones. After C6 total laminectomy and foraminotomy, the C6 body was returned to its proper position. Secondly, anterior stabilization and fusion were performed by C6-7 discectomy with a screw-plate system. A postoperative lateral plain radiograph showed good realignment. In this case, we report the clinical presentation and discuss the surgical modalities of C6-7 total spondyloptosis and the failed close reduction.

등입도 투수성 콘크리트 보강 조립토 다짐말뚝의 거동특성 및 침하량 평가기법 (A Estimation Method of Settlement and The Behaviour Characteristics of Granular Compaction Pile Reinforced with Uniformly Graded Permissible Concrete)

  • 김정호;황정순;김승욱;김종민;김홍택
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.362-371
    • /
    • 2006
  • The behaviour characteristics of Granular Compaction Pile(GCP) are mainly governed by the lateral confining pressure mobilized in the matrix soft soil to restrain the bulging failure of the granular compaction pile. The GCP method is most effective in soft soil with untrained shear strength ranging from $15\sim50\;kPa$. However, the efficiency of this method is falling down in the more compressible soil conditions, which does not provide sufficient lateral confinement. In the present study, the GCP method reinforced with uniformly graded permissible concrete is suggested for the extension of application to the soft ground. Also, large triaxial compression tests are conducted on composite- reinforced soil samples for verification of availability of the suggested method and the settlement estimation method of the reinforced GCP is proposed. Further, for the verification of a validity of the proposed method, predicted settlements are compared with results of numerical analyses. Tn addition, parametric studies are performed together with detailed analyses of relevant design parameters.

  • PDF