Browse > Article
http://dx.doi.org/10.12989/scs.2022.43.4.483

Fire resistance tests of LSF walls under combined compression and bending actions  

Peiris, Mithum (Queensland University of Technology (QUT))
Mahendran, Mahen (Queensland University of Technology (QUT))
Publication Information
Steel and Composite Structures / v.43, no.4, 2022 , pp. 483-500 More about this Journal
Abstract
Cold-formed steel wall panels sheathed with gypsum plasterboard have shown superior thermal and structural performance in fire. Recent damage caused by fire events in Australia has increased the need for accurate fire resistance ratings of wall systems used in low- and mid-rise construction. Past fire research has mostly focused on light gauge steel framed (LSF) walls under uniform axial compression and LSF floors under pure bending. However, in reality, LSF wall studs may be subject to both compression and bending actions due to eccentric loading at the wall to-roof or wall-to-floor connections. In order to investigate the fire resistance of LSF walls under the effects of these loading eccentricities, four full-scale standard fire tests were conducted on 3 m × 3 m LSF wall specimens lined with two 16 mm gypsum plasterboards under different combinations of axial compression and lateral load ratios. The findings show that the loading eccentricity can adversely affect the fire resistance level of the LSF wall depending on the magnitude of the eccentricity, the resultant compressive stresses in the hot and cold flanges of the wall studs caused by combined loading and the temperatures of the hot and cold flanges of the studs. Structural fire designers should consider the effects of loading eccentricity in the design of LSF walls to eliminate their potential failures in fire.
Keywords
cold-formed steel; combined compression and bending; loading eccentricity; LSF wall panels; standard fire tests;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Xu, L., Yang, S. and Cui, J. (2017), "Fire performance of CFS walls with web-perforated studs - A numerical investigation", Eurosteel, Ce/papers, 1(2-3), 2553-2562. https://doi.org/10.1002/cepa.304.   DOI
2 Steau, E. and Mahendran, M. (2021), "Elevated temperature thermal properties of fire protective boards and insulation materials for light steel frame systems", J. Build. Eng., 102571. https://doi.org/10.1016/j.jobe.2021.102571.   DOI
3 Thanasoulas, I.D., Vardakoulias, I.K., Kolaitis, D.I., Gantes, C.J. and Founti, M.A. (2018), "Coupled thermo-mechanical simulation for the performance-based fire design of CFS drywall systems", J. Constr. Steel Res., 145, 196-209. https://doi.org/10.1016/j.jcsr.2018.02.022.   DOI
4 Rajanayagam, H., Upasiri, I., Poologanathan, K., Gatheeshgar, P., Sherlock, P., Konthesingha, C., Nagaratnam, B. and Perera, D. (2021), "Thermal performance of LSF wall systems with vacuum insulation panels", Buildings, 11(12), 621. https://doi.org/10.3390/buildings11120621.   DOI
5 Rokilan, M. and Mahendran, M. (2020), "Elevated temperature mechanical properties of cold-rolled steel sheets and coldformed steel sections", J. Constr. Steel Res., 167, 105851. https://doi.org/10.1016/j.jcsr.2019.105851.   DOI
6 Standards Australia (2014), AS 1530.4, Methods for Fire Tests on Building Materials, Components and Structures, Part 4: FireResistance Test of Elements of Construction, Sydney, Australia
7 Ariyanayagam, A.D. and Mahendran, M. (2018), "Fire performance of load bearing LSF wall systems made of low strength steel studs", Thin-Walled Struct., 130, 487-504. https://doi.org/10.1016/j.tws.2018.05.018.   DOI
8 Selvaraj, S. and Madhavan, M. (2019), "Improvements in AISI design methods for gypsum-sheathed cold-formed steel wall panels subjected to bending", J. Struct. Eng., 145(2), 04018243. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002223.   DOI
9 Ariyanayagam, A.D. and Mahendran, M. (2014), "Numerical modelling of load bearing light gauge steel frame wall systems exposed to realistic design fires", Thin-Walled Struct., 78, 148-170. https://doi.org/10.1016/j.tws.2014.01.003.   DOI
10 Ariyanayagam, A.D. and Mahendran, M. (2018), "Experimental study of non-load bearing light gauge steel framed walls in fire", J. Constr. Steel Res., 145, 529-551. https://doi.org/10.1016/j.jcsr.2018.02.023.   DOI
11 Ariyanayagam, A.D. and Mahendran, M. (2019), "Influence of cavity insulation on the fire resistance of light gauge steel framed walls", Constr. and Build. Mater., 203, 687-710. https://doi.org/10.1016/j.conbuildmat.2019.01.076.   DOI
12 Chen, W., Ye, J., Zhao, Q. and Jiang, J. (2020), "Full-scale experiments of gypsum-sheathed cavity-insulated cold-formed steel walls under different fire conditions", J. Constr. Steel Res., 164, 105809. https://doi.org/10.1016/j.jcsr.2019.105809.   DOI
13 Chen, W., Ye, J., Bai, Y. and Zhao, X.L. (2012), "Full-scale fire experiments on load-bearing cold-formed steel walls lined with different panels", J. of Constr. Steel Res., 79, 242-254. https://doi.org/10.1016/j.jcsr.2012.07.031.   DOI
14 Gunalan, S. and Mahendran, M. (2013), "Finite element modelling of load bearing cold-formed steel wall systems under fire conditions", Eng. Struct., 56, 1007-1027. https://doi.org/10.1016/j.engstruct.2013.06.022.   DOI
15 Magarabooshanam, H., Ariyanayagam, A. and Mahendran, M. (2019), "Behaviour of load bearing double stud LSF walls in fire", Fire Safety J., 107, 15-28. https://doi.org/10.1016/j.firesaf.2019.05.003.   DOI
16 Peiris, M., Mahendran, M. (2022), "Advanced numerical modelling of light-gauge steel framed walls subject to eccentric compression", Eng. Struct., 256, 114063. https://doi.org/10.1016/j.engstruct.2022.114063.   DOI
17 Schafer, B.W. (2019), "Advances in the direct strength method of cold-formed steel design", Thin-Walled Struct., 140, 533-541. https://doi.org/10.1016/j.tws.2019.03.001.   DOI
18 Feng, M., Wang, Y.C. and Davies, J.M. (2018), "Behaviour of loaded full-scale cold-formed thin-walled steel structural panels under fire conditions", Thin-Walled Struct., CRC Press, 307-314. https://doi.org/10.1201/9781351077309-33.   DOI
19 Gnanachelvam, S., Ariyanayagam, A. and Mahendran, M. (2020), "Fire resistance of LSF wall systems lined with different wallboards including bio-PCM mat", J. Build. Eng., 32, p.101628. https://doi.org/10.1016/j.jobe.2020.101628   DOI
20 Jatheeshan, V. and Mahendran, M. (2016), "Experimental study of cold-formed steel floors made of hollow flange channel section joists under fire conditions", J. Struct. Eng., 142, 04015134. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001409.   DOI
21 Kyvelou, P., Gardner, L. and Nethercot, D.A. (2018), "Finite element modelling of composite cold-formed steel flooring systems", Eng. Struct., 158, 28-42. https://doi.org/10.1016/j.engstruct.2017.12.024.   DOI
22 Pancheti, J., Mahendran, M. and Steau, E. (2022), "Fire resistance of external LSF walls with corrugated steel cladding", J. Constr. Steel Res., 188, 107008. https://doi.org/10.1016/j.jcsr.2021.107008.   DOI
23 Peiris, M. and Mahendran, M. (2021), "Behaviour of cold-formed steel lipped channel sections subject to eccentric axial compression", J. Constr. Steel Res., 184, 106808. https://doi.org/10.1016/j.jcsr.2021.106808.   DOI
24 Kodur, V.K.R. and Sultan, M.A. (2006), "Factors influencing fire resistance of load-bearing steel stud walls", Fire Technol., 42(1), 5-26. https://doi.org/10.1007/s10694-005-3730-y.   DOI
25 Dias, Y., Mahendran, M. and Poologanathan, K. (2019), "Fullscale fire resistance tests of steel and plasterboard sheathed web-stiffened stud walls", Thin-Walled Struct., 137, 81-93. https://doi.org/10.1016/j.tws.2018.12.027.   DOI
26 Gnanachelvam, S., Ariyanayagam, A. and Mahendran, M. (2021), "Effects of insulation materials and their location on the fire resistance of LSF walls", J. Build. Eng., 44, 103323. https://doi.org/10.1016/j.jobe.2021.103323.   DOI
27 Kesawan, S. and Mahendran, M. (2018), "A review of parameters influencing the fire performance of light gauge steel frame walls", Fire Technol., 54(1), 3-35. https://doi.org/10.1007/s10694-017-0669-8.   DOI