• Title/Summary/Keyword: lateral compression

Search Result 381, Processing Time 0.022 seconds

Qualitative Anatomical Characteristics of Compression Wood, Lateral Wood, and Opposite Wood in a Stem of Ginkgo biloba L.

  • Purusatama, Byantara Darsan;Kim, Yun-Ki;Jeon, Woo Seok;Lee, Ju-Ah;Kim, Ah-Ran;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.125-131
    • /
    • 2018
  • This study was conducted to understand and to compare the qualitative aspects of anatomical characteristics in compression wood (CW), lateral wood (LW), and opposite wood (OW) in a stem of Ginkgo biloba. The qualitative analysis was examined by optical microscopy and scanning electron microscopy. CW in Ginkgo biloba disks were dark brown in color, and the OW and LW were light brown in color. CW and OW showed abrupt transitions from earlywood to latewood, while LW showed a gradual transition. Cross sections of CW presented circular tracheids with angular outlines, many intercellular spaces, and varying sizes of lumens. Cross sections of LW and OW showed rectangular tracheids, fewer intercellular spaces, and varying sizes of lumens. In radial sections, CW showed an irregular arrangement of tracheids in earlywood, while LW and OW showed comparatively regular arrangements. Slit-like bordered pits on the tracheid cell wall, piceoid pits in the crossfield, and a few spiral checks were present in CW. LW and OW showed bordered pits with slightly oval-shaped apertures, as well as cuppresoid pits in the crossfields. Rays were primarily uniseriate, with few biseriate rays in the tangential sections of CW, LW, and OW. The tips of the tracheids were branched in CW but had a normal appearance in LW and OW.

Development of Design Method of Compression(SSC) Anchor (압축헝 앵커의 설계법 개발)

  • 임종철;홍석우;이태형;이외득
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.63-78
    • /
    • 1999
  • For the design of compression anchor, three things should be considered. The first is a resistance force by skin friction, the second is a tension strength of tendon, and the third is a compressive strength of grout. Especially, compressive strength of grout is the most important design parameter of compression anchor. When compression anchor is pulled out from the ground, the compressive strength of grout increases by confining pressure of ground($\sigma_{tg$). Here, $\sigma_{tg$ is the confining pressure which is produced by earth pressure at rest and by lateral expansion of grout. We call this phenomenon of increase of confining pressure "poisson effect". In this paper, the design method of compression anchor called SSC anchor and the computer program for the design are developed through compression tests of anchor body grout.ody grout.

  • PDF

Buckling Analysis of Anisotropic Laminated Plates with Shear Deformation (전단변형을 고려한 이방성 적층판의 좌굴해석)

  • 최용희;권택진
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.361-368
    • /
    • 2001
  • This paper deals with the buckling load of antisymmetric angle-ply and cross-ply laminated rectangular plates. Buckling analysis is preformed for a simply supported, shear deformable laminated plate subjected to uniaxial compression and biaxial compression combined with uniform lateral pression. The shear deformation theory is considered to figure out a more exact behavior of laminated plates exactly. The purposes of this study are to formulate anisotropic laminated plates with shear deformation and to investigate the buckling load according to the various variables of laminated plates by using the exact solutions for anisotropic laminated plates having simply supported boundary.

  • PDF

Confining Effect of CFS on Concrete Compressive Members under Load Actions (하중이력에 따른 콘크리트 압축부재의 CFS 보강효과에 관한 연구)

  • 배주성;김경수;김재욱;고영표
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.705-708
    • /
    • 1999
  • Advanced composite materials such as carbon fiber, aramid, and glass fiber sheet, are widely used recently to strengthening existing reinforced concrete structures. The purpose of this paper was to investigate the mechanical characteristics of concrete compressive members confined with carbon fiber sheet and evaluate the efficiency of the strengthening under load actions. Uniaxal compression tests of concrete compressive members confined with carbon fiber sheet were experimentally used to develop a relationship between the axial stresses and the lateral stresses. The resulting axial and lateral strains were used to determine the confinement effect of concrete compressive members.

  • PDF

Geometrically Nonlinear Analysis of Cantilevered Cylindrical Shells under Lateral Load (탑상형 원통쉘의 휨내력에 관한 기하학적 비선형 해석)

  • 최현식
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.10a
    • /
    • pp.55-62
    • /
    • 1993
  • Elastic failures of cantilevered cylindrical shells subject to lateral load are caused mainly by geometrical nonlinearlity. Geometerally nonlinear analysis is call for so as to investigate failure mechanisms. In this paper the geometericlly nonlinear analysis of cantilevered cylindrical shells under transverse load by the Rayleigh-Ritz Method is presented to examine the collapse loads and the process of cross-sectional deformations. The critical stress for relatively long cylinders have a tendency to show low level in comparison with the classical buckling stress for compression.

  • PDF

A Study on the Prevention Effect of Lateral Movement by Finite Element Analysis (유한요소해석에 의한 측방이동 방지효과에 대한 연구)

  • Park, Choon-Sik;Rho, Tae-Kyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.12
    • /
    • pp.71-82
    • /
    • 2018
  • This study presents a reasonable and economical DCM reinforcement length for the various factors (the embankment height, the distance from the embankment to the underground structure, the depth of the soft ground, and the compression index and the swelling index of the soft ground) that affect the stability of the structure due to lateral movement. Based on these results, we analyzed each factor's degree of influence and figured out which factor influenced the lateral movement most. The cross section of the embankment on the soft ground was modeled by using the Finite Element Program and reinforced with DCM. The results show that the increase rate of the reinforcement length with the increase of the embankment height is about 9~50%, the increase rate of the reinforcement length with the depth of soft ground is about 13~30%, and the increase rate of the reinforcement length with increasing compression index is about 3~25%. In addition, the influence of each factor on each other was analyzed. As a result, among the separation distance, the compressive index and the maximum to minimum slope ratio of the reinforcement length of the embankment height, the separation distance was the largest for the depth of soft ground. As the depth of the soft ground increases, the ratio of the maximum to minimum slope of the reinforcement length according to the embankment height is 3.75, the ratio of the maximum to minimum slope of the reinforcement length according to the spacing distance is 4.3, and the ratio of maximum to minimum slope according to compression index is 2.5. From these results, it is confirmed that the three factors are greatly affected by the depth of soft ground.

Uniaxial Compression Behavior of High-Strength Concrete Confined by Low-Volumetric Ratio Lateral Ties

  • Hong Ki-Nam;Han Sang-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.843-852
    • /
    • 2005
  • Presently, test results and stress-strain models for poorly confined high-strength columns, more specifically for columns with a tie volumetric ratio smaller than $2.0\%$, are scarce. This paper presents test results loaded in axial direction for square reinforced concrete columns confined by various volumetric ratio lateral ties including low-volumetric ratio. Test variables include concrete compressive strength, tie yield strength, tie arrangement type, and tie volumetric ratio. Local strains measured using strain gages bonded to an acryl rod. For square RC columns confined by lateral ties, the confinement effect was efficiently improved by changing tie arrangement type from Type-A to Type-B. A method to compute the stress in lateral ties at the concrete peak strength and a new stress-strain model for the confined concrete are proposed. Over a wide range of confinement parameters, the model shows good agreement with stress-strain relationships established experimentally.

Lateral loading test for partially confined and unconfined masonry panels

  • Tu, Yi-Hsuan;Lo, Ting-Yi;Chuang, Tsung-Hua
    • Earthquakes and Structures
    • /
    • v.18 no.3
    • /
    • pp.379-390
    • /
    • 2020
  • Four full-scaled partially confined and unconfined masonry panels were tested with monotonic lateral loads. To study the effects of vertical force and boundary columns, two specimens with no boundary columns were subjected to different vertical forces, while two wing-wall specimens had the column placed eccentrically and in the middle, respectively. The specimens with no boundary columns exhibited ductile rocking behavior, where the lateral strength increased with increasing vertical compression. The wing-wall specimens with columns behaved as strut-and-tie systems. The column-panel interaction resulted in greater strength, lower deformation capacity and differences in failure modes. A comparison with analytical models showed that rocking strength can be accurately estimated using vertical force and the panel aspect ratio for panels with no boundary columns. The estimation for lateral strength on the basis of a panel section area indicated scattered error for wing-wall specimens.

The Strength Characteristics of Concrete Confined with Composite Fiber (복합섬유(複合纖維) 횡보강(橫補强)콘크리트의 강도(强度) 특성(特性)에 관한 연구(硏究))

  • Jang, Jeong-Su;Jo, Seong-Chan;Gang, Chung-Ryeor
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.93-102
    • /
    • 2001
  • The objective of this experimental study is to evaluate the strengthening effects of concrete compression confined with Epoxy-boned compound fiber sheets. An analytical model is proposed to construct a stress-strain relationship for confined concrete. Test results are summarized as followed. While non-FRP lateral confinement specimens appeared sudden failure after shell concrete was torn off, specimens confined laterally with FRP were showed that their failure. Specially, Glass fiber lateral confined specimens occurred obviously increase ductility ability. Hence, concrete specimen with lateral confinement by Hi-carborn and Aramide. Glass fiber simultaneously can be increased in not only strength but also a lot of ductility ability.

  • PDF

Tarsal Tunnel Syndrome secondary to the Neurilemoma of first branch of the Lateral Plantar Nerve (외족장신경 제1분지의 신경초종에 의해 발생된 족장터널증후군)

  • Lee, Kyung-Tai;Tak, Sang-Bo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.2 no.1
    • /
    • pp.52-55
    • /
    • 1998
  • Tarsal tunnel syndrome is a complex of symptoms resulting from the compression of the posterior tibial nerve or its branches, Many disease have been previously reported in the literatures as etiological agents in tarsal tunnel syndrome. We reported a case of tarsal tunnel syndrome secondary to neurilemoma of the first branch of lateral plantar nerve. The symptoms were similar with the entrapment syndrome of the first branch of the lateral plantar nerve. Symptoms were completely relieved after operation.

  • PDF