• 제목/요약/키워드: lateral capacity

검색결과 813건 처리시간 0.027초

A Study on the Lateral Flow of the Silts which is Polluted with a Garbage Leachate to the Dyes (쓰레기 침출수와 염료로 오염된 실트지반의 측방유동에 관한 연구)

  • Ahn, Jong-Pil;Park, Sang-Bum;Ahn, Ki-Mun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1157-1166
    • /
    • 2008
  • Critical surcharge value of silt ground polluted with garbage leachate to the dyes $q_{cr}=3.73c_u$ and ultimate bearing capacity value $q_{ult}=8.60c_u$. Lateral flow pressure at polluted silt ground was about $P_{max}$/3 and depth of maximum lateral flow pressure was found at that of H/3 of soft layer thickness(H). Expression of polluted silt ground of fracture baseline at stability control charge by Matsuo Kawamura is $S_v=3.56\exp\{0.51(Y_m/S_v)\}$.

  • PDF

A Study on the Skin Friction Characteristics of SIP(Soil-cement Injected Precast Pile) (SIP 말뚝의 주면마찰 특성에 관한 연구)

  • 천병식;임해식;강재모;김도형;지원백
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.583-588
    • /
    • 2002
  • As environmental problem in course of construction has been a matter of interest, noise and vibration in the process of piling are considered as a serious problem. For this reason, the use of SIP method inserting pile as soon as boring and cement grouting is rapidly increasing for preventing vibration and noise. But a resonable bearing capacity formula for SIP method does not exit and even the standard specification for domestic condition isn't formed, though the lateral friction between cement paste and the ground does an important role and boring depth largely influences to the design bearing capacity, applying the SIP method . Therefore, the lateral friction was analyzed after the direct shear test worked with the lateral face of SIP and the soil.

  • PDF

A Experimental Study for Stress-Strain Behavior and Energy Capacity of Confinement Steel (심부구속철근의 응력-변형률 거동 및 에너지 성능에 관한 실험적 연구)

  • Lee, Jae-Hoon;Ko, Seong-Hyun;Hwang, Jung-Kil;Son, Hyun-A
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.77-80
    • /
    • 2006
  • Longitudinal reinforcements of the plastic hinge region were behaved tensile deformation and compressional deformation by direction of lateral loading. However Confinement steels were behaved only tensile deformation by lateral loading. Transverse steels were laid the state of tension in the lateral loading of time, and they were laid state that stress is zero when it was removed lateral load. Nine specimens were tested under cyclic stresses(tension and zero). The purpose of this research is to investigate the strain behavior and capacity of energy for confinement steel. The selected test variables are $L/d_b(L/d_b=6)$, size of reinforcement and specified yielding strength(300, 400, 500 MPa).

  • PDF

Experiment of Lateral Load Resistance of Dori-Directional Frame in Traditional Wood Structure System (전통목구조 시스템의 도리방향 골조의 횡저항 성능에 대한 실험)

  • Lee, Young-Wook;Hong, Sung-Gul;Kim, Nam-Hee;Jung, Sung-Jin;Hwang, Jong-Kook;Bae, Boung-Sun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.241-246
    • /
    • 2007
  • The capacity of a lateral load resistance of a joint with Jangbu-connection of Dori-directional frame in traditional wood structure system was studied, through experiments of 1/2 scaled and T-shaped 7 subassemblies of joint of Dori-directional frame for Deawoongjeon of Bongjungsa. From the experiment, it was shown that the capacity of a lateral load resistance was influenced by the vertical load confining joint and not influenced by the number of Chok and the depth of Changbang, And lateral load resistance mechanism is developed by the restraint between the vertical load and the contacting edge of column; if structure is pushed to the left, the top-right end of Pyeongju contacts with Changbang and left Changbang loses the contacts with Pyeongju and therefore only right Changbang can resist to lateral load.

  • PDF

Finite element analysis of granular column for various encasement conditions subjected to shear load

  • Jaiswal, Akash;Kumar, Rakesh
    • Geomechanics and Engineering
    • /
    • 제29권6호
    • /
    • pp.645-655
    • /
    • 2022
  • Granular columns have recently found widespread use in underground construction. The behaviour of granular columns under vertical loads has been extensively studied, specifically in relation to vertical load capacity obtained by bulging of the column body, including the behaviour after encasement of material. Determining the shear strength of loose soils reinforced with granular columns has received less attention. After the observations of lateral deformation near the toe of the embankment, attempts have been made to strengthen the lateral strength of granular columns. The purpose of this research is to look into the effects of different encasement conditions on the lateral load capacity of granular columns. This was accomplished by three-dimensional finite element analysis with FEM software. Various normal pressures and two different encasement configurations, namely single layer encasement and double layer encasement, with differing tensile strengths, were used in this study to determine their effect on lateral resistance. The failure envelope for a single column planted in loose sand was used to analyse the findings for three different granular column diameters, as well as the impact of different encasement conditions. According to the findings, the inclusion of a Granular Column enhanced the shear strength and overall stiffness of the loose sand bed, and the encasement of the Granular Column helped in deriving higher lateral resistance.

Effect of Edge Confinement on Deformation Capacity in the Isolated RC Structural Walls (벽체 단부의 횡보강근 양에 따른 변형능력의 평가)

  • 한상환;오영훈;이리형
    • Journal of the Korea Concrete Institute
    • /
    • 제11권6호
    • /
    • pp.101-112
    • /
    • 1999
  • Structural walls have been mostly used for the design of reinforced concrete buildings in seismic areas because they play a role as an efficient bracing system and offer great potential for lateral load resistance and drift control. The lateral resistance system for the earthquake load should be designed to have enough ductility and stable hysteretic response in the critical regions where plastic deformation occurred beyond yielding. The behavior of the reinforced concrete element to experience large deformation in the critical areas by a major earthquake is affected by the performance of the confined core concrete. Thus, the confinement of concrete by suitable arrangements of transverse reinforcement results in a significant increase in both the strength and ductility of compressed concrete. This paper reports the experimental results of reinforced concrete structural walls for wall-type apartment structure under axial loads and cyclic reversal of lateral loads with different confinement of the boundary elements. The results show that confinement of the boundary element by open 'U'-bar and cross tie is effective. The shear strength capacity is not increased by the confinement but deformation capacity is improve.

Capacity of Concrete Filled Carbon Tube Columns Based on the Comparison of Ductility and Energy Dissipation Capacity (연성도 및 에너지 소산능력 비교에 따른 콘크리트충전 탄소섬유튜브 기둥의 성능)

  • Lee, Kyoung-Hun;Hong, Won-Kee;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • 제11권1호
    • /
    • pp.29-35
    • /
    • 2007
  • Flexural capacity estimation test of concrete filled carbon tube (CFCT) column under the cyclic lateral load was carried out in this study. Thickness of carbon tube and winding angles of carbon fiber were chosen as test parameters and two types of column with square and circular sections were manufactured. To act axial and lateral load, three dynamic actuators were used and all specimens were made with actual size. Flexural stiffness, ability of deformation, energy dissipation capacity and ductility behavior. of CFCT column were analyzed with test data.

A Study on the Bearing Capacity of Rammed Aggregate Pier as the Intermediate Foundations (중간기초개념으로서 짧은 쇄석다짐말뚝의 지지력 특성에 관한 연구)

  • CHUN BYUNG-SIK;KIM KYUNG-MIN;KIM JUN-HO
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.247-252
    • /
    • 2004
  • To secure stability and availability of Rammed Aggregate Pier method as the foundation of a structure, the bearing capacity and failure behavior characteristics was studied through soil laboratory tests in a model ground. In this study, soil laboratory tests use carried out to find the applicability of RAP method as the foundation of a structure. And bearing capacity and the failure mechanism of RAP method was studied according to relative density($60\%,\;70\%,\;90\%$), diameter(45mm, 60mm, 70mm) of each pier ana depth(5cm, l0cm, 15cm, 20cm, 25cm, 30cm). Earth pressure cell is set up approach RAP and 1.0D space at RAP center. Bearing acpacity and the failure mechanism of RAP is investigated by load test As a result, bulging failure was happened in $5\~10cm\;(1.0D\~2.00)$ depth which the maximum lateral earth pressure is acting. Especially, diameter changing of RAP are in inverse proportion to the relative density and the lateral stress is very much influenced by the lateral earth pressure in every layer and tends to decrease according to depth.

  • PDF

Capacity Development of Existing Frame by Aramid Sheet and Energy Dissipation Device (아라미드 시트와 에너지 소산 장치에 의한 기존 골조의 능력 향상)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제19권5호
    • /
    • pp.112-119
    • /
    • 2015
  • In this paper, the strengthening method was proposed for improving the seismic performance of the vulnerable structural frames. To improve the brittle characteristics of columns, aramid fiber sheet was used for the lateral confinement of columns. And to introduce the energy dissipation capacity, a steel damper with S-shaped struts was installed. By making the unreinforced and reinforced specimens with full size specimens were evaluated for lateral load resistance capacity. It was confirmed the strengthening effects by the evaluation of failure shape, strength, stiffness degradation, and energy dissipation capacity. Also from the FE analysis using ABAQUS, the hysteretic behavior of the specimens were predicted and evaluated.

Experimental study on seismic performances of steel framebent structures

  • Liang, Jiongfeng;Gu, Lian S.;Hu, Ming H.
    • Earthquakes and Structures
    • /
    • 제10권5호
    • /
    • pp.1111-1123
    • /
    • 2016
  • To study seismic performance of steel frame-bent structure, one specimen with one-tenth scale, three-bay, and five-story was tested under reversed cyclic lateral load. The entire loading process and failure mode were observed, and the seismic performance indexes including hysteretic loops, skeleton curve, ductility, load bearing capacity, drift ratio, energy dissipation capacity and stiffness degradation were analyzed. The results show that the steel frame-bent structure has good seismic performance. And the ductility and the energy dissipation capacity were good, the hysteresis loops were in spindle shape, which shape were full and had larger area. The ultimate elastic-plastic drift ratio is larger than the limit value specified by seismic code, showing the high capacity of collapse resistance. It can be helpful to design this kind of structure in high-risk seismic zone.