• Title/Summary/Keyword: later phase

Search Result 282, Processing Time 0.027 seconds

Effects of Phase Feeding on Growth Performance, Nutrient Digestibility and Nutrient Excretion of Growing Barrows and Gilts

  • Kim, Y.G.;Jin, J.;Kim, J.D.;Kim, J.H.;Han, In K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.6
    • /
    • pp.795-801
    • /
    • 2000
  • A total of 120 growing crossbred pigs ($Landrace{\times}Large$ $White{\times}Duroc$) with equal numbers of barrows and gilts were used in the feeding trial in a $2{\times}3$ factorial arrangement (gender by feeding regimens) to investigate the effect of phase feeding on growth performance during the 25 to 58 kg body weight growth stage, and 6 pigs (three of each sex) were used in a metabolic trial. The growing period was divided into two phases and 4 different CP diets were used to make 3 different feeding regimens (GE18-GL18; 18% CP diets for both early and later growing period, GE18-GL16; 18% CP diet for early and 16% CP diet for later growing period, GE19-GL17; 19% CP diet for early and 17% CP diet for later growing period). There were no significant differences in growth performance among treatments during the entire growing period. However, during the later growing period, feed intake of barrows was significantly higher than that of gilts (p<0.05). Average daily gain of barrows was higher than that of gilts (p>0.05). Based on the result, growth performance differences between barrows and gilts appeared to begin after 40 kg of body weight. There was no significant difference in digestibility among treatments or between sexes. During the early growing period the 18% CP diet showed better digestibility than the 19% CP diet. However, during the later growing period, the 18% and 17% CP diets exhibited similar digestibilities, although 16% CP diet showed slightly lower digestibility than 18% and 17% CP diets. During the early growing period, fecal N and P excretion of pigs fed the 19% CP were higher than that of those fed the 18% CP diet. During later growing period, fecal N and P excretion by those receiving the two phase feeding compared to single phase feeding was reduced by 10.2% and 2.0%, respectively. In the gilts, the cost reduction by two phase feeding (GE18-GL16) compared to single feeding was around 3.81%, but that of barrows was only 0.52%. The results suggested that the same nutrient levels could be applied to barrows and gilts during the growing period. Also, this study suggested the optimum protein and lysine level for early and later growing pigs to be 18% CP, 1.0% lysine and 16% CP, 0.8% lysine, respectively. Feeding two diets to growing pigs, i.e., two-phase feeding, would be more appropriate than feeding a single diet on economic and environmental considerations.

Technique development of Bi-2212/2223 superconductor thick film manufacturing by plasma spraying and heat treatment (플라즈마 용사 및 열처리 공정을 통한 Bi-2212/2223 초전도체 thick film 제조의 기술 개발)

  • Lee, Seon-Hong;Cho, Sang-Hum;Ko, Young-Bong;Park, Kyeung-Chae
    • Proceedings of the KWS Conference
    • /
    • 2005.11a
    • /
    • pp.262-264
    • /
    • 2005
  • $Bi_{2}Sr_{2}CaCu_{2}O_{x}$(Bi-2212) and $Bi_{2}Sr_{2}Ca_{2}Cu_{3}O_{y}$(Bi-2223) high-$T_{c}$ superconductor(HTS) coating have been prepared by plasma spraying and heaat treatment. The Bi-2212 HTS coating later is synthesized through the peritectic reaction between Sr-Ca-Cu oxide coating layer and Bi-Cu oxide coating later, and $Bi_{2}Sr_{2}CaCu_{2}O_{y}$(Bi-2212) superconducting phase grow by partial melting process. The superconducting characteristic depends strongly on the conditions of the partial melting process. the Bi-2212 HTS layer consists of the whiskers grown in the diffusion direction. Above the 2212 layer, Bi-2223 phase and secondary phase was observed. The secondary phase is distributed uniformly over the whole surface. This is caused to the microcrack on the coatings surface. Despite everything, the film shows superconducting with an onset $T_{c}$ of about 115K. There are two changes steps. One changes (1step) at 115K is due to the diamagnetism of the Bi-2223 phase and the other changes (2step) at 78K is due to the diamagnetism of the Bi-2212 phase.

  • PDF

A SIMPLE DISK-HALO MODEL FOR THE CHEMICAL EVOLUTION OF OUR GALAXY

  • Lee, S.W.;Ann, H.B.
    • Journal of The Korean Astronomical Society
    • /
    • v.14 no.2
    • /
    • pp.55-71
    • /
    • 1981
  • On the basis of observational constraints, particularly the relationship between metal abundance and cumulative stellar mass, a simple two-zone disk-halo model for the chemical evolution of our Galaxy was investigated, assuming different chemical processes in the disk and halo and the infall rates of the halo gas defined by the halo evolution. The main results of the present model calculations are: (i) The halo formation requires more than 80% of the initial galactic mass and it takes a period of $2{\sim}3{\times}10^9$ yrs. (ii) The halo evolution is divided into two phases, a fast collapse phase ($t=2{\sim}3{\times}10^8$ yrs) during which period most of the halo stars $({\sim}95%)$ are formed and a later slow collapse phase which is characterized by the chemical enrichment due to the inflow of external matter to the halo. (iii) The disk evolution is also divided into two phases, an active disk formation phase with a time-dependent initial mass function (IMF) up to $t{\approx}6{\times}10^9$ yrs and a later steady slow formation phase with a constant IMF. It is found that at the very early time $t{\approx}5{\times}10^8$ yrs, the metal abundance in the disk is rapidly increased to ${\sim}1/3$ of the present value but the total stellar mass only to ${\sim}10%$ of the present value, finally reaching about 80% of the present values toward the end of the active formation phase.

  • PDF

Balance Recovery Mechanisms Against Anterior Perturbation during Standing (직립자세에서의 전방향 동요 시 균형회복 기전)

  • 태기식;김영호
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.435-442
    • /
    • 2003
  • In this paper, biomechanical aspects of dynamic대학교postural responses against forward perturbations were experimentally determined simultaneous measurements of joint angles, accelerations. EMG activations, center of pressure(CoP) movements and ground reaction forces(GRF), Thirteen young healthy volunteers, stood on a flat platform, were translated into the forward direction by an AC servo-motor at two separate velocities(0.1m and 0.2m/s). In order to recover postural balance against the forward perturbation, joint motions were observed in the sequence of the ankle dorsiflexion, the knee flexion and then the hip flexion during the later acceleration phase. Both acceleration patterns at the heel and the sacrum were shown the forward acceleration pattern during the later acceleration phase and early of constant velocity phase as increasing platform velocity, respectively. Tibialis anterior(TA) for the ankle dorsiflexion and biceps femoris(BF) for the knee flexion. the primary muscle to recover the forward perturbation, was activated during the half of acceleration phase. Ankle strategy was used for slow-velocity perturbation, but mixed strategy of both ankle and hip used for the fast-velocity perturbation. In addition, parameters of perturbation such as timing and magnitude influenced the postural response against the perturbation.

ON MEASURING THE WELDING TEMPERATURE OF CONNECTOR

  • Deng Jyh-jeng
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.361-377
    • /
    • 1998
  • The measurement of welding temperature of connector is usually performed with an infra red temperature gauge. However, the factors, which influence the temperature measurement, are rarely known. This research used the welding temperature measurement of the connector as an example, applying the experimental design, in two-phase experiments, to search the affecting factors. In phase-I experiment, we used a resolution III, seven-factor fractional factorial design with two levels for each factor. The result showed that none of the factor was significant in affecting the welding temperature when the type I error ${\alpha}$ was 0.05. Next, we did the phase-II factorial experiment with three factors and each factor had three levels. The experiment showed the experimental time was significant in affecting the temperature measurement when the type I error ${\alpha}$ was 0.05. Further Duncan's multiple range tests on the second experimental data showed that the later the experimental time, the weaker the light intensity could have on the temperature measurement and the average of the highest temperatures was lower. Moreover, the later the experimental time, the smaller was the variance of the temperature measurement and the difference between the averages of the highest and the lowest temperatures was also lower.

  • PDF

Design of Single-Phase Line-Start Permanent Magnet Motor Using Equivalent Circuit Method

  • Kwon, Sun-Hyo;Lee, Chul-Kyu;Kwon, Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.490-495
    • /
    • 2006
  • In this research, the design procedure and the design method of a single-phase line-start permanent magnet motor (LSPM) are proposed. In the design procedure, the permanent magnet is designed first and the windings and capacitors are designed later. As well, the points of design of each design parameter are explained. In the design of the single-phase LSPM, the equivalent circuit method is combined with the finite element method (FEM) because it has a shorter analysis time than FEM. The 400 watts single-phase LSPM is designed and manufactured. The characteristics of the manufactured single-phase LSPM are analyzed and experimented. From the analysis result and the experiment result, it is verified that the design procedure and the design method of the single-phase LSPM is valid.

PREPARATION OF POLY(ETHYLENE-CO-VINYL ALCOHOL) MEMBRANE VIA THERMALLY INDUCED PHASE SEPARATION

  • Matsuyama, Hideto;Shang, Mengxian;Teramoto, Masaaki
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.74-77
    • /
    • 2004
  • Porous membranes were prepared via thermally induced phase separation (TIPS) of (ethylene-co-vinyl alcohol) (EVOH)/glycerol mixtures. The liquid-liquid (L-L) phase boundaries are shifted to higher temperature when the ethylene contents in EVOH increase. Moreover, the kinetic study proved that the growth of droplets formed by the general liquid-liquid (L-L) phase separation obeyed a power-law scaling relationship in the later stage of spinodal decomposition (SD). A new phase separation mechanism was presented, in which the L-L phase separation could be resulted from the crystallization. The hollow fiber membranes were prepared. The membranes showed asymmetric structures with skin layer near the outer surface, the larger pores just below the skin layer and the smaller pores near the inner surface. The effect of ethylene content (EC) in EVOH, cooling water bath temperature and take-up speed on membrane performance was investigated.

  • PDF

Precipitation of Manganese in the p-Xylene Oxidation with Oxygen-Enriched Gas in Liquid Phase

  • Jhung, Sung-Hwa;Park, Youn-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.3
    • /
    • pp.369-373
    • /
    • 2002
  • The liquid phase oxidation of p-xylene has been carried out with oxygen-enriched gas, and the manganese component was precipitated probably via over-oxidation to $Mn^{4+}$. The precipitation increased with rising oxygen concentration in the reaction gas and occurred mainly in the later part of the oxidation. The activity of the reaction decreased, and the blackening of the product and side reactions to carbon dioxide increased with the degree of precipitation. Precipitation can be decreased with the addition of metal ions, such as cerium, chromium and iron.

A Four State Rotational Frequency Detector for Fast Frequency Acquisition

  • Yeo, Hyeop-Goo
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.3
    • /
    • pp.305-309
    • /
    • 2011
  • This paper proposes a new rotational frequency detector (RFD) for phase-locked loop (PLL) or clock and data recovery (CDR) applications for fast frequency acquisition. The proposed RFD uses the four states finite state machine (FSM) model to accelerate the frequency acquisition time. It is modeled and simulated with MATLAB Simulink. The functionalities of the proposed RFD are examined and the results are compared to those of a conventional RFD. The proposed RFD's frequency acquisition time is four times faster than that of a conventional one. The proposed RFD incorporated with a phase detector (PD) in PLL or CDR is expected to improve the frequency and phase acquisition performance later greatly.