• Title/Summary/Keyword: latent power

Search Result 124, Processing Time 0.027 seconds

Concept of an intelligent operator support system for initial emergency responses in nuclear power plants

  • Kang, Jung Sung;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2453-2466
    • /
    • 2022
  • Nuclear power plant operators in the main control room are exposed to stressful conditions in emergency situations as immediate and appropriate mitigations are required. While emergency operating procedures (EOPs) provide operators with the appropriate tasks and diagnostic guidelines, EOPs have static properties that make it difficult to reflect the dynamic changes of the plant. Due to this static nature, operator workloads increase because unrelated information must be screened out and numerous displays must be checked to obtain the plant status. Generally, excessive workloads should be reduced because they can lead to human errors that may adversely affect nuclear power plant safety. This paper presents a framework for an operator support system that can substitute the initial responses of the EOPs, or in other words the immediate actions and diagnostic procedures, in the early stages of an emergency. The system assists operators in emergency operations as follows: performing the monitoring tasks in parallel, identifying current risk and latent risk causality, diagnosing the accident, and displaying all information intuitively with a master logic diagram. The risk causalities are analyzed with a functional modeling methodology called multilevel flow modeling. This system is expected to reduce workloads and the time for performing initial emergency response procedures.

A latent profile analysis of job performance types based on task performance, contextual performance and counterproductive work behavior (과업수행, 맥락수행, 반생산적 업무행동 기반의 직무수행 유형 분석: 잠재프로파일분석을 중심으로)

  • Yoo, Young-Sam;Kim, Myoung-So;Noh, So-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.145-155
    • /
    • 2020
  • Since Campbell (1990) proposed multidimensionality of job performance, unlike the single structure of traditional job performance, it has been largely classified as task performance, contextual performance, and counterproductive work behavior. The objective of this study is to validate the threecriteria currently considered major aspects of job performance, to identify different types of performance based on three dimensions, and to compare the power of personality factors among performance types. A total of 681 employees working at various organizations participated in an on-line survey. The survey included boththe exploratory and confirmatory factor analyses. A 3-factor job performance model consisting of three dimensions was also included. The relationships between performance dimensions and personality factors differedby dimensions of performance, supporting the validity of the 3-factor structure of performance.The results of the Latent Profile Analysis identified four types of performance: exemplary, moderately conscientious moderate, and conscientious, butlow.. The Multinomial logistic regression analysis showed each type differed significantly according to the predictors of personality variables. In conclusion, implications and limitations of the study were noted.

PROPOSAL FOR DUAL PRESSURIZED LIGHT WATER REACTOR UNIT PRODUCING 2000 MWE

  • Kang, Kyoung-Min;Noh, Sang-Woo;Suh, Kune-Yull
    • Nuclear Engineering and Technology
    • /
    • v.41 no.8
    • /
    • pp.1005-1014
    • /
    • 2009
  • The Dual Unit Optimizer 2000 MWe (DUO2000) is put forward as a new design concept for large power nuclear plants to cope with economic and safety challenges facing the $21^{st}$ century green and sustainable energy industry. DUO2000 is home to two nuclear steam supply systems (NSSSs) of the Optimized Power Reactor 1000 MWe (OPR1000)-like pressurized water reactor (PWR) in single containment so as to double the capacity of the plant. The idea behind DUO may as well be extended to combining any number of NSSSs of PWRs or pressurized heavy water reactors (PHWRs), or even boiling water reactors (BWRs). Once proven in water reactors, the technology may even be expanded to gas cooled, liquid metal cooled, and molten salt cooled reactors. With its in-vessel retention external reactor vessel cooling (IVR-ERVC) as severe accident management strategy, DUO can not only put the single most querulous PWR safety issue to an end, but also pave the way to very promising large power capacity while dispensing with the huge redesigning cost for Generation III+ nuclear systems. Five prototypes are presented for the DUO2000, and their respective advantages and drawbacks are considered. The strengths include, but are not necessarily limited to, reducing the cost of construction by decreasing the number of containment buildings from two to one, minimizing the cost of NSSS and control systems by sharing between the dual units, and lessening the maintenance cost by uniting the NSSS, just to name the few. The latent threats are discussed as well.

Research Trend Analysis for Smart Grids Using Dynamic Topic Modeling (동적 토픽분석을 활용한 스마트그리드 연구동향 분석)

  • Na, Sang-Tae;Ahn, Joo-Eon;Jung, Min-Ho;Kim, Ja-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.613-620
    • /
    • 2017
  • The power grid has been changed to a smart grid system to satisfy the growing need for power grid complexity, demand, reliability, security, and efficiency with a combination of existing power and ICT technology. This study analyzes the research trends in smart grid technology in the period since the introduction of the smart grid system and compares it with industrial trends to grasp the progress and characteristics of Smart Grid technology and look for ways to innovate the technology. To do this, we analyze the research trends using dynamic topic modeling, which is capable of time-series research topic analysis. Next, we compare the results of research trends with industrial trends analyzed by Gartner's experts to demonstrate that smart grid research is evolving to the level of industrialization. The results of this study are quantitative analysis through data mining, and it is expected that it will be used in many fields such as companies that want to participate in industry and government agencies that need to establish policies by showing more objective analysis results.

Forecasting probabilities of earthquake in Korea based on seismological data (지진 관측자료를 기반으로 한 한반도 지진 발생 확률 예측)

  • Choi, Seowon;Jang, Woncheol
    • The Korean Journal of Applied Statistics
    • /
    • v.30 no.5
    • /
    • pp.759-774
    • /
    • 2017
  • Earthquake concerns have grown after a remarkable earthquake incident on September 12th, 2016 in Gyeongju, Korea. Earthquake forecasting is gaining in importance in order to guarantee infrastructure safety and develop protection policies. In this paper, we adopt a power-law distribution model to fit past earthquake occurrences in Korea with various historical and modern seismological records. We estimated power-law distribution parameters using empirical distributions and calculated the future probabilities for large earthquake events based on our model. We provide the probability that a future event has a larger magnitude than given levels, and the probability that a future event over certain levels will occur in a given period of time. This model contributes to the assessment of latent seismological risk in Korea by estimating future earthquake probabilities.

Three-Parallel System Operation and Grid-Connection Technique for High-Power Wind Turbines using a PMSG (PMSG를 이용한 풍력 발전 시스템의 3병렬 운전과 계통 연계 기술)

  • Lee, Sang-Hyouk;Jung, Hea-Gwang;Lee, Kyo-Beum;Choi, Se-Wan;Choi, Woo-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.296-308
    • /
    • 2010
  • This paper proposes a design of the three-parallel converter system and grid-connection technique for a PMSG based wind turbine systems. The back-to-back converter of the PMSG based wind turbine system is directly connected to the grid so that both the power devices and the filters are needed to have large power ratings. The three-parallel converter configuration can reduce the required power ratings of the devices and filters. However, the three-parallel converter can cause circulating currents. These circulating currents can be suppressed by sellecting proper inner inductance at each leg. An LCL filter design is used to meet the THD regulations. The latent resonance caused by the LCL filter is compensated by an active damping method without additional loss. The decline of the power quality caused by the unbalanced and distorted grid voltages is also compensated with an additional compensation algorithm. The simulation and experimental results show that the proposed system and compensation methods are effective for the wind turbine systems.

Operation Characteristics According to Steam Temperature and Effectivenss of External Steam-Related SOEC System (외부 수증기 연계 SOEC 시스템의 공급 스팀 온도 및 열교환기 유용도에 따른 시스템 BOP 및 운전 특성 분석)

  • KIM, YOUNG SANG;LEE, YOUNG DUK;AHN, KOOK YOUNG;LEE, DONG KEUN;LEE, SANG MIN;CHOI, EUN JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.6
    • /
    • pp.596-604
    • /
    • 2020
  • Solid oxide electrolysis cell (SOEC) attracts much attention because of its high energy efficiency among many water-electrolysis technologies. SOEC operates at temperatures above 700℃, so that the water required for water-electrolysis must be supplied in the form of steam. When the steam to be supplied to the SOEC is generated by the SOEC system itself, an enormous amount of latent heat is required to vaporize the water, so additional energy must be supplied to the SOEC system. On the other hand, if the steam can be supplied from the outside, a small amount of energy is required to raise the temperature of the low temperature steam, so that the SOEC system can be operated without additional energy supply from outside, which enables efficient water-electrolysis. In this study, we figure out the size of heat exchanger for various steam temperature and effectiveness of heat exchanger, and propose the energy efficiency of the system.

Satellite Thermal Control Device Enhanced by Latent Heat of the Phase Change Material (응고/융해 잠열을 이용한 위성용 열제어장치의 실험적 연구)

  • Kim, Tae Su;Shin, Yoon Sub;Kim, Taig Young;Seo, Jung-gi;Hyun, Bum-Seok;Cheon, Hyeong Yul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.10
    • /
    • pp.887-894
    • /
    • 2016
  • The thermal control device using solid-liquid phase change material (PCM) is designed, manufactured, and experimented in thermal environment chamber. The n-Hexadecane is selected as a PCM and its melting point is placed within the component working temperature range. The PCM container is made of Al6061 and has the thermal spreading fins inside. To simulate the working condition for on-orbit satellite the heat pipes are used to connect the heater and radiator and the PCM thermal control device (PCMTD) is installed at the middle portion of heat pipes. The thermal buffer mass (TBM), which is same configuration and volume with PCMTD, is also manufactured to compare the thermal control performance. As a result, the PCMTD is not only more efficient than TBM in their temperature control features but both mass and power of compensation heater are reduced.

An Analysis on Identifying Typology of Intergenerational Relationship and Affecting Factors among the Old Retirees According to the Eligibility of Public Pension (공적연금 수급 여부에 따른 노년기 세대관계 잠재 유형 분류 및 영향 요인 분석)

  • Jo, Gee-Yong;Lee, Jong-Ha
    • Journal of Family Resource Management and Policy Review
    • /
    • v.17 no.4
    • /
    • pp.189-213
    • /
    • 2013
  • The purpose of this work is to explore different types of intergenerational relationships in the later lives of old retirees. This will be done according to the eligibility of public pension and the old age social security system so that the factors affecting intergenerational relationships can be analyzed, and to propose a plan to improve social adaptation in later life. The data used in this work are the Fourth basic survey data of the 2011 Korea Retirement and Income Study. The study subjects of this work were 2,435 retirees over age 65 who had children. In this study, latent class analysis and logistic regression analysis were conducted to classify types of intergenerational relationships and to analyze the influence of relevant factors. As a result of the analysis, some of those in the group were eligible for public pension, and the ones who were not were classified into three types: the closely-living-together type, the separate-living-contact type, and the estrangement type. In the group not eligible for public pension, it was found that age, spouse, number of children, economic factors, and level of health satisfaction gave significant power to intergenerational relationships. In the group eligible for public pension, it was found that age, income and net assets, ADL(Activities of Daily Living), whether there was an IADL(Instrumental Activities of Daily Living) spouse, and number of children affected types of intergenerational relationships; Socio-demographic factors, economic factors, and healthy factors became significant variables according to the classified types of intergenerational relationship. Based on the study results, this work suggested such necessities to lay the foundation for an elderly welfare system for social adaptation in later life, This includes the offering of programs for retirement preparation, the use of family and local society resources, and expansion of the opportunity to participate in social activities.

  • PDF

Performance of a Latent Heat Storage System Using Two-Phase Closed Thermosyphon(II) - The Case of Constant Temperature Heating Fluid (열싸이폰을 이용한 잠열축열시스템의 성능실험(II) - 일정한 온도의 가열유체를 사용한 경우 -)

  • Kim, Tae-Il;Kim, Ki-Hyun
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.37-46
    • /
    • 1992
  • An experimental study was carried out to investigate the performance of a latent heat storage system using paraffin wax as the phase change material. A thermosyphon was employed to transfer heat from the hot ethylene glycol flowing across the evaporator section of the thermosyphon into the wax. In order to increase the effective thermal conductivity of wax, layers of copper wire mesh were immersed in the wax. Experiments were run for volume ratios of 2%, 3%, and 4%, varying mass flow rate of ethylene glycol in each case. Some of the important results are as follows : (1) The wire mesh enhanced the conductive hea transfer and thus, helped even out the temperature distribution in the wax : (2) The increase of the number of layers of wire mesh increased the conduction. However, it also resulted in increasing the resistance to the convective motion of liquefied wax : and (3) There is an optimal number of layers of wire mesh, maximizing the performance of the storage system, which occurred at a volume ratio of $3{\sim}4%$ in the present study.

  • PDF