• Title/Summary/Keyword: laser scan data

Search Result 104, Processing Time 0.022 seconds

Scan Matching based De-skewing Algorithm for 2D Indoor PCD captured from Mobile Laser Scanning (스캔 매칭 기반 실내 2차원 PCD de-skewing 알고리즘)

  • Kang, Nam-woo;Sa, Se-Won;Ryu, Min Woo;Oh, Sangmin;Lee, Chanwoo;Cho, Hunhee;Park, Insung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.3
    • /
    • pp.40-51
    • /
    • 2021
  • MLS (Mobile Laser Scanning) which is a scanning method done by moving the LiDAR (Light Detection and Ranging) is widely employed to capture indoor PCD (Point Cloud Data) for floor plan generation in the AEC (Architecture, Engineering, and Construction) industry. The movement and rotation of LiDAR in the scanning phase cause deformation (i.e. skew) of PCD and impose a significant impact on quality of output. Thus, a de-skewing method is required to increase the accuracy of geometric representation. De-skewing methods which use position and pose information of LiDAR collected by IMU (Inertial Measurement Unit) have been mainly developed to refine the PCD. However, the existing methods have limitations on de-skewing PCD without IMU. In this study, a novel algorithm for de-skewing 2D PCD captured from MLS without IMU is presented. The algorithm de-skews PCD using scan matching between points captured from adjacent scan positions. Based on the comparison of the deskewed floor plan with the benchmark derived from TLS (Terrestrial Laser Scanning), the performance of proposed algorithm is verified by reducing the average mismatched area 49.82%. The result of this study shows that the accurate floor plan is generated by the de-skewing algorithm without IMU.

Direct Finite Element Model Generation using 3 Dimensional Scan Data (3D SCAN DATA 를 이용한 직접유한요소모델 생성)

  • Lee Su-Young;Kim Sung-Jin;Jeong Jae-Young;Park Jong-Sik;Lee Seong-Beom
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.5 s.182
    • /
    • pp.143-148
    • /
    • 2006
  • It is still very difficult to generate a geometry model and finite element model, which has complex and many free surface, even though 3D CAD solutions are applied. Furthermore, in the medical field, which is a big growth area of recent years, there is no drawing. For these reasons, making a geometry model, which is used in finite element analysis, is very difficult. To resolve these problems and satisfy the requests of the need to create a 3D digital file for an object where none had existed before, new technologies are appeared recently. Among the recent technologies, there is a growing interest in the availability of fast, affordable optical range laser scanning. The development of 3D laser scan technology to obtain 3D point cloud data, made it possible to generate 3D model of complex object. To generate CAD and finite element model using point cloud data from 3D scanning, surface reconstruction applications have widely used. In the early stage, these applications have many difficulties, such as data handling, model creation time and so on. Recently developed point-based surface generation applications partly resolve these difficulties. However there are still many problems. In case of large and complex object scanning, generation of CAD and finite element model has a significant amount of working time and effort. Hence, we concerned developing a good direct finite element model generation method using point cloud's location coordinate value to save working time and obtain accurate finite element model.

Multi-facet 3D Scanner Based on Stripe Laser Light Image (선형 레이저 광 영상기반 다면 3 차원 스캐너)

  • Ko, Young-Jun;Yi, Soo-Yeong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.10
    • /
    • pp.811-816
    • /
    • 2016
  • In light of recently developed 3D printers for rapid prototyping, there is increasing attention on the 3D scanner as a 3D data acquisition system for an existing object. This paper presents a prototypical 3D scanner based on a striped laser light image. In order to solve the problem of shadowy areas, the proposed 3D scanner has two cameras with one laser light source. By using a horizontal rotation table and a rotational arm rotating about the latitudinal axis, the scanner is able to scan in all directions. To remove an additional optical filter for laser light pixel extraction of an image, we have adopted a differential image method with laser light modulation. Experimental results show that the scanner's 3D data acquisition performance exhibited less than 0.2 mm of measurement error. Therefore, this scanner has proven that it is possible to reconstruct an object's 3D surface from point cloud data using a 3D scanner, enabling reproduction of the object using a commercially available 3D printer.

Pulsed Laser Deposition $Na_{0.5}K_{0.5}NbO_3$ Thin Film (PLD 기법에 의한 $Na_{0.5}K_{0.5}NbO_3$ 박막 제작)

  • 최원석;문병무;조중래
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.33.1-35
    • /
    • 2000
  • Na-K-Nb system showed a number of ferroelectric phases in bulk ceramic. [001]-axis oriented single-phase $Na_{0.5}/K_{0.5}NbO_3$(NKN) thin film have been grown on $LaA1O_3$substrates using KrF excimer laser. X-ray diffraction $\theta$-2$\theta$ scan, rocking curves, and $\varphi$ scan data evidence highly c-axis oriented along the [001] direction.

  • PDF

Pulsed Laser Deposition $Na_{0.5}K_{0.5}NbO_{3}$ Thin Film (PLD 기법에 의한 $Na_{0.5}K_{0.5}NbO_{3}$ 박막 제작)

  • 최원석;문병무;조중래
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.33-35
    • /
    • 2000
  • Na-K-Nb system showed a number of ferroelectric phases in bulk ceramic. [001]-axis oriented single-phase Na$_{0.5}$K$_{0.5}$NbO$_3$ (NKN) thin film have been grown on LaA1O$_3$ substrates using KrF excimer laser. X-ray diffraction $\theta$-2$\theta$ scan, rocking curves, and $\phi$ scan data evidence highly c-axis oriented along the [001] direction.ion.

  • PDF

Distance Measurement Based on Structured Light Image for Mobile Robots (이동로봇을 위한 구조광 영상기반 거리측정)

  • Yi, Soo-Yeong;Hong, Young-Jin;Suh, Jin-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.18-24
    • /
    • 2010
  • In this paper, we address an active ranging system based on laser structured light image for mobile robot application. Since the burdensome correspondence problem is avoidable, the structured light image processing has efficient computation in comparison with the conventional stereo image processing. By using a cylindrical lens in the laser generation, it is possible to convert a point laser into a stripe laser without motorized scan in the proposed system. In order to achieve robustness against environmental illumination noise, we propose an efficient integro-differential image processing algorithm. The proposed system has embedded image processing module and transmits distance data to reduce the computational burden in main control system.

The Reflected Property Analysis of 3D Laser Scanning System as Object Surface Materials (대상물 표면물질에 따른 3차원 레이저스캐닝 시스템의 반사특성분석)

  • Um, Dae-Yong;Kim, Ji-Hye
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.3
    • /
    • pp.347-356
    • /
    • 2009
  • Recently many kind of industry request 3D Modeling and visualize for object. So application of 3D laser scanning system is improved for 3D modeling and survey. But although application of scanner is steady improved, there are variety of caution error is contained in the result. There is request high quality survey for it is restricted by when field. To analysis what is consider major factor of reflect ratio about surface specification as ratio and characteristics accidental error. So this research use 3D laer scanning system what is adopted method of laser measurement for improvement accuracy 3D scan data. As a result we can check reflect volume will be improve as specification of survey object if it has high reflect ratio. It able to improve accuracy how laser scan data is revised by reflect volume.

Organizing Lidar Data Based on Octree Structure

  • Wang, Miao;Tseng, Yi-Hsing
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.150-152
    • /
    • 2003
  • Laser scanned lidar data record 3D surface information in detail. Exploring valuable spatial information from lidar data is a prerequisite task for its applications, such as DEM generation and 3D building model reconstruction. However, the inherent spatial information is implicit in the abundant, densely and randomly distributed point cloud. This paper proposes a novel method to organize point cloud data, so that further analysis or feature extraction can proceed based on a well organized data model. The principle of the proposed algorithm is to segment point cloud into 3D planes. A split and merge segmentation based on the octree structure is developed for the implementation. Some practical airborne and ground lidar data are tested for demonstration and discussion. We expect this data organization could provide a stepping stone for extracting spatial information from lidar data.

  • PDF

Characteristics of Nanolithography Process on Polymer Thin-film using Near-field Scanning Optical Microscope (근접장현미경을 이용한 폴리머박막 나노리쏘그라피 공정의 특성분석)

  • 권상진;김필규;장원석;정성호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.590-595
    • /
    • 2004
  • The shape and size variations of the nanopatterns produced on a positive photoresist using a near-field scanning optical microscope(NSOM) are investigated with respect to the process variables. A cantilever type nanoprobe having a 100nm aperture at the apex of the pyramidal tip is used with the NSOM and a He-Cd laser at a wavelength of 442nm as the illumination source. Patterning characteristics are examined for different laser beam power at the entrance side of the aperture( $P_{in}$ ), scan speed of the piezo stage(V), repeated scanning over the same pattern, and operation modes of the NSOM(DC and AC modes). The pattern size remained almost the same for equal linear energy density. Pattern size decreased for lower laser beam power and greater scan speed, leading to a minimum pattern width of around 50nm at $P_{in}$ =1.2$\mu$W and V=12$\mu$m/. Direct writing of an arbitrary pattern with a line width of about 150nm was demonstrated to verify the feasibility of this technique for nanomask fabrication. Application on high-density data storage using azopolymer is discussed at the end.

  • PDF

Finite Element Mesh Generation from 3D Laser Scanned Data (3차원 레이저 스캐닝 점 좌표 데이터로부터 CAE 유한 요소 메쉬 생성 알고리즘 개발)

  • Jarng S.S.;Yang H.J.;Lee J.H.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.10 no.1
    • /
    • pp.70-75
    • /
    • 2005
  • A 3D solid element mesh generation algorithm was newly developed. 3D surface points of global rectangular coordinates were supplied by a 3D laser scanner. The algorithm is strait forward and simple but it generates mixed solid elements such as hexagonal, pyramid and prism types. Then, the surface triangular or rectangular elements were generated from the solid elements. The key of the algorithm is elimination of elements and 3D adaptive surface smoothing using given 3D surface point data.