• Title/Summary/Keyword: laser measurement

Search Result 2,033, Processing Time 0.034 seconds

An Combustion Diagnosis Using Optical Measurement in D. I Diesel Engine with Dual Fuel Stratified Injection System (이종연료 층상분사를 적용한 디젤엔진에서 광 계측을 이용한 연소해석)

  • An, H.C.;Kang, B.M.;Yeom, J.K.;Chung, S.S.;Ha, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.7 no.3
    • /
    • pp.31-37
    • /
    • 2002
  • In previous study, diesel-methanol stratified injection system is manufactured and applied to a D.I. diesel engine in order to realize combustion improvement using methanol, which is oxygenated fuel with large latent heat. We know that NOx and soot is reduced by stratified injection of diesel fuel-methanol. Therefore, in the present study, combustion diagnosis using optical measurement is tried to make clear effect of methanol on simultaneous reduction of NOx and soot. Two-color method is used to measure flame temperature and KL value, which is approximately proportional to the soot consentration along the optical path. Laser induced scattering method was used to measure distribution of soot at two dimensional area. Also, it is compared exhaust characteristics of NOx and soot with results of optical measurement.

  • PDF

Error Compensation of Laser Interferometer for Measuring Displacement Using the Kalman Filter

  • Park, Tong-Jin;Lee, Yong-Woo;Wang, Young-Yong;Han, Chang-Soo;Lee, Nak-Ku;Lee, Hyung-Wok;Choi, Tae-Hoon;Na, Kyung-Whan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.2
    • /
    • pp.41-46
    • /
    • 2004
  • This paper proposes a robust discrete time Kalman filter (RDKF) for the dynamic compensation of nonlinearity in a homodyne laser interferometer for high-precision displacement measurement and in real-time. The interferometer system is modeled to reduce the calculation of the estimator. A regulator is applied to improve the robustness of the system. An estimator based on dynamic modeling and a zero regulator of the system was designed by the authors of this study. For real measurement, the experimental results show that the proposed interferometer system can be applied to high precision displacement measurement in real-time.

  • PDF

Cryogenic Temperature Measurement Using Amplified Spontaneous Emission of Erbium-Doped Fiber (오븀 첨가 광섬유의 증폭 자발 방출을 이용한 저온 측정)

  • Lee, Yong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1992-1994
    • /
    • 2007
  • In this paper we propose a cryogenic sensor system which can measure the temperature at higher resolution at low temperature using temperature-dependent amplified spontaneous emission of erbium-doped fiber pumped by a 1480 nm laser diode. The measurement resolution of the sensor system could be enhanced through the modulation of injection current of the pump laser diode. The measurement resolution considering the fluctuation of the light source in the sensor system was ${\sim}0.4$ K in the room temperature regime and ${\sim}0.07$ K in the liquid nitrogen temperature regime.

Study on Characteristics of Diesel Particualte Matter and it's Measurement and Evaluation (디젤 입자상물질의 특성 및 측정 평가에 관한 연구)

  • 김복윤;이상권;조영도
    • Tunnel and Underground Space
    • /
    • v.6 no.1
    • /
    • pp.48-56
    • /
    • 1996
  • Presently, mobile diesel equipments contribute a lot to improve the economic feasibility of underground mining and tunneling operations. Even in Korea, a lot of diesel equipments are being applied to the undergroud workings already, but the technology of management and control of them is not sufficient yet. This study handled the production procedure, characteristics and evaluation technology on diesel particulate matte(DPM) which is known as a carcinogen. For easy measurement of DPM using laser dust monitor, conversion known as a carcinogen. For easy measurement of DPM using laser dust monitor, conversion factor(k) to gravimetric concentration has been acquired. It is appeared that the critical material among the diesel exhaust pollutants is becoming DPM instead of NOx from this year of 1996 according to the Government regulation.

  • PDF

Simultaneous Measurement of Velocity and Concentration Field in a Stirred Mixer Using PIV/LIF Techniqueut and POD Analysis (PIV/LIF에 의한 교반혼합기 유동의 난류 속도/농도장 측정 및 POD해석)

  • Jeong Eun-Ho;Yoon Sang-Youl;Kim Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.101-104
    • /
    • 2002
  • Simultaneous measurement of turbulent velocity and concentration field in a stirred mixer tank is carried out by using PIV/LIF technique. Instantaneous velocity fields are measured by a $1K\times1K$ CCD camera adopting the frame straddle method while the concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. It is found that the general features of the mixing pattern are quite dependent on the local flow characteristics during the rapid decay of mean concentration. However, the small scale mixing seems to be independent on the local turbulent velocity fluctuation.

  • PDF

Waviness measurement of workpiece with a Large Surface Area (대면적 공작물의 기하학적 Waviness 측정)

  • Kang D.B.;Son S.M.;Ah J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.115-118
    • /
    • 2005
  • A workpiece with a large surface area is likely to be uneven due to form error and waviness. These geometric disturbances can cause inaccurate micro shapes to be formed when micro features are micro-grooved into the surface and cause the resulting workpiece to fail to function as desired. Thus, real-time measurement and compensation is required to guarantee the form accuracy of micro features while machining a workpiece with a large surface area. In this study, a method is suggested for real-time measurement of geometric error for the micro grooving of a large flat surface using a laser displacement sensor. The measurements are demonstrated for the workpieces with large surface areas and the experimental results show that the waviness and form error are well detected.

  • PDF

An Optoelectronical Flank Wear Monitoring Technique of Cutting Tools (절삭공구 플랭크 마모의 광전자학적 측정 시스템 개발)

  • Jeon, Jong-Up;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.4 no.3
    • /
    • pp.60-68
    • /
    • 1987
  • An optoelectronical method for in process monitoring of flank wear of cutting tools is presented. The method is based upon real-time vision technology in which the tool is illuminated by a beam of laser and then the image of wear zone is taken by a vidicon camera. The image is converted to a series of digital pixel data and processed through an algorithm specially developed for measurement of the wear land width. Detailed aspects of the prototype measurement system byilt for experiment are described, and test results are discussed. As conclusions, it is proved that the methods are effec- tive especially for-in situ application with a measuring accuracy of 0.01mm.

  • PDF

Effect of $CO_2$ Laser on Caries Inhibition Evaluated by Laser Fluorescence Measurement (이산화탄소 레이저의 우식 억제 효과에 대한 레이저형광측정 평가)

  • Kim, Seong-Hyeong;Lee, Kwang-Hee;Kim, Dae-Eop;Lee, Ji-Young;Song, In-Kyung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.153-160
    • /
    • 2003
  • The purpose of study was to evaluate the effects of the $CO_2$ laser irradiation on demineralization inhibition and rehardening of human primary tooth enamel by laser fluoresecence measurement. Enamel specimens were made from the human primary teeth. The center spots of the specimens about 2 mm diameter were irradiated by $CO_2$ laser at the conditions of focused continuous or defocused pulsed, 3 or 6 W, for 4 seconds, before or after the demineralization by Coca-Cola for 24 hours at $37^{\circ}C$. The Diagnodent was used to measure the degree of demineralization and rehardening. There was no significant difference between focused continuous and defocused pulsed irradiation. 6W irradiation inhibited the demineralization but 3W did not. 6W irradiation rehardened the demineralized enamel but 3W did partially. The color of enamel was changed to brown to black after 6W irradiation but 3W caused no color change. $CO_2$ laser irradiation showed the effects on demineralization inhibition and rehardening of human priamary tooth enamel, and the laser fluoresecence measurement technique seemed to be a valid evaluation method.

  • PDF

Development of 2-Dimension Radar Distance Measurement System with 24 GHz Antenna Module and Its Performance Evaluation (24 GHz 안테나 모듈을 이용한 2차원 레이더 거리 측정 시스템 개발 및 성능 평가)

  • Go, Seok-Jo;Kim, Tae-Hoon;Cha, Byung-Soo;Park, Min-Kyu;Moon, Young-Gun;Yu, Ki-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.19 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Laser distance measuring systems are used in many fields with high precision. However, when measuring the reflector such as the mirror and the black color, a laser distance measuring system does not guarantee the measurement accuracy. In order to measure the shape of the cargo, this study proposes the radar distance measurement system. The radar distance measuring system is composed of a distance measuring unit with a 24 GHz antenna module, a signal processing and control board and the 1-axis tilting unit. And, this study developed a monitoring program to monitor the measured data. In order to evaluate performance of the developed system, the distance measurement tests are carried out. The distance error was about 6-15 cm. However, considering the size of the cargo, the precision is not a problem. And, cargo shape was measured by using the distance information measured by the 1-axis tilting unit. It could get a 2 dimension shape profile for the cargo stacked in a yard.

Measurement of Large Mirror Surface using a Laser Tracker (레이저트래커(Laser Tracker)를 이용한 대형 광학 거울의 형상 측정)

  • Jo, Eun-Ha;Yang, Ho-Soon;Lee, Yun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.6
    • /
    • pp.331-337
    • /
    • 2013
  • A large optical surface is fabricated by grinding, polishing and figuring. The grinding process is the most rapid and has the largest amount of fabrication of all processes. If we measure the surface precisely and rapidly in the grinding process, it is possible to improve the efficiency of the fabrication process. Since the surface of grinding process is rough and not shiny, it is not easy to measure the surface using light so that we cannot use an interferometer. Therefore, we have to measure the surface using a mechanical method. We can measure the surface under the grinding process by using a laser tracker which is a portable 3-dimensional coordinate measuring machine. In this paper, we used the laser tracker to measure the surface error of 1 m diameter spherical mirror. This measurement result was compared to that of an interferometer. As a result, surface measurement error was found to be $0.2{\mu}m$ rms (root mean square) and $2.7{\mu}m$ PV (Peak to Valley), which is accurate enough to apply to the rough surface under the grinding stage.