• 제목/요약/키워드: laser mark

검색결과 27건 처리시간 0.025초

Shear bond strengths of aged and non-aged CAD/CAM materials after different surface treatments

  • Kilinc, Hamiyet;Sanal, Fatma Ayse;Turgut, Sedanur
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.273-282
    • /
    • 2020
  • PURPOSE. To assess shear bond strengths (SBS) of resin composites on aged and non-aged prosthetic materials with various surface treatments. MATERIALS AND METHODS. Cerasmart (CE), Vita Enamic (VE), Vita Mark II (VM), and IPS e.max CAD (EC) blocks were sliced, and rectangular-shaped specimens (14 × 12 × 1.5 mm; N = 352) were obtained. Half of the specimens were aged (5000 thermal cycles) for each material. Non-aged and aged specimens were divided into 4 groups according to the surface treatments (control, air abrasion, etching, and laser irradiation; n = 11) and processed for scanning electron microscopy (SEM). The repair procedure was performed after the surface treatments. SBS values and failure types were determined. Obtained data were statistically analyzed (P≤.05). RESULTS. The material type, surface treatment type, and their interactions were found significant with regard to SBS (P<.001). Aging also had a significant effect on prosthetic material-resin composite bonding (P<.001). SBS values of non-aged specimens ranged from 12.16 to 17.91 MPa, while SBS values of aged specimens ranged from 9.46 to 15.61 MPa. Non-aged VM in combination with acid etching presented the highest score while the control group of aged CE showed the lowest. CONCLUSION. Etching was more effective in achieving durable SBS for VM and EC. Laser irradiation could be considered as an alternative surface treatment method to air abrasion for all tested materials. Aging had significant effect on SBS values generated between tested materials and resin composite.

광자기 디스크 재생신호 시뮬레이션에 관한 연구 (A Study on Simulation Of Readout Signal of Magnet-Optic Disk)

  • 손장우;조순철;이세광;김순광
    • 한국자기학회지
    • /
    • 제6권3호
    • /
    • pp.174-178
    • /
    • 1996
  • 광자기 디스크 드라이브의 광학계로부터 검출 신호와 잡음을 시뮬레이션하는 방법을 연구하였다. 기록된 표식과 입사되는 레이저 빔 형태를 간단한 모델을 사용하여 기술하고 각각을 이산화시켜 재생 신호의 크기와 파형을 시륨레이션 하였다. 이렇게 시뮬레이션된 재생 신호에 Gaussian 램덤 잡음을 부가하고 일차원 이산 FFT(Fast Fourier Transform) 알고리즘을 수행하여 신호와 잡음 스펙트럼을 추정하였다. 또한 이로부터 CNR(Carrier to Noise Ratio) 값을 구하였다.

  • PDF

Crosserase와 crosstalk이 DVD 재생 신호에 미치는 영향 (Crosserase and Crosstalk Effects on Readout Signal of Digital Versatile Disks)

  • 박연수;김지원;조순철
    • 전자공학회논문지CI
    • /
    • 제38권4호
    • /
    • pp.33-38
    • /
    • 2001
  • 고밀도 기록매체인 DVD RAM 시스템에서 단면 기록밀도 4.7 GB, 15 GB 매체 개발 실현에 가장 큰 걸림돌로 작용하고 있는 crosserase 및 crosstalk 현상이 재생 신호에 미치는 영향을 분석하기 위해 4.7 GB 및 15 GB 규격으로 재생 신호를 시뮬레이션 하였다. 디스크에 조사된 빔의 강도는 Gaussian으로 근사화하고 기록된 마크는 타원형 마크로 가정하였으며, 재생신호는 Gaussian 빔 패턴과 마크 패턴의 이중 적분으로 계산되었다. Crosserase 정도를 변하여 얻어진 재생 신호로부터 주파수 분석을 통하여 3T-11T 마크의 carrier level의 크기를 구하여 비교하였다. 1,000개의 3T-11T 랜덤 마크로 부터 crosserase 및 crosstalk 에 의한 지터를 계산하여 비교한 결과, crosserase에 의한 지터가 crosstalk에 의한 지터 보다 상대적으로 작음을 확인할 수 있었다.

  • PDF

가시광 레이저를 이용한 수광소자의 수동정렬 및 플립칩본딩 (Passive Alignment of Photodiode by using Visible Laser and Flip Chip Bonding)

  • 유정희;이세형;이종진;임권섭;강현서
    • 마이크로전자및패키징학회지
    • /
    • 제14권3호
    • /
    • pp.7-13
    • /
    • 2007
  • 광통신용 광모듈에서 광소자와 광섬유 또는 도파로를 정밀하게 정렬 및 접합하기 위하여 플립칩본딩 방법 이 널리 이용되고 있다. 이때 광소자를 정확한 위치에 정렬시키기 위하여 기판과 광소자 양쪽에 정렬용 마크를 제작하고 플립칩본더 등을 사용하여 정렬마크를 관찰하며 광소자를 정렬 및 본딩하게 된다. 본 연구에서는 이러한 정렬마크의 제작비용을 줄이고 광섬유와 수광소자(PD 칩)의 수동정렬을 용이하게 하기 위하여 He-Ne 레이저(파장 633nm)인 가시광을 이용한 정렬 및 플립칩본딩 방법을 연구하였다. 광섬유에서 방출되는 레이저 광을 육안으로 관찰하면서 수광소자를 정렬하므로써 패키징에 소요되는 시간과 경비를 절감하고 광모듈의 저가격화를 실현 할 수 있는 새로운 방법이다. 광섬유에 가공되어 있는 V-노치를 경유하여 가시광이 광섬유에 대해 직각방향으로 방출되고 이것을 수광소자와 정렬하는 방법이다. 본 연구결과 광정렬을 위해 입사된 633 nm파장의 가시광 레이저와 통신용 레이저인 1550 nm 파장사이의 파장 차이에 의한 광경로 차이는 약 4m으로 무시가능하고 최대 광세기 지점에서 ${\pm}20\;{\mu}m$ 범위내에서는 광결합효율 변화는 약 2%이었으며 최대 광결합효율은 약 23.3%이었다.

  • PDF

ER71/ETV2 Promotes Hair Regeneration from Chemotherapeutic Drug-Induced Hair Loss by Enhancing Angiogenesis

  • Lee, Tae-Jin;Kang, Hee-Kyoung;Berry, Jeffrey C.;Joo, Hong-Gu;Park, Changwon;Miller, Mark J.;Choi, Kyunghee
    • Biomolecules & Therapeutics
    • /
    • 제29권5호
    • /
    • pp.545-550
    • /
    • 2021
  • Chemotherapy-induced alopecia and hair loss can be stressful in patients with cancer. The hair grows back, but sometimes the hair tends to stay thin. Therefore, understanding mechanisms regulating hair regeneration may improve the management of chemotherapy-induced alopecia. Previous studies have revealed that chemotherapeutic agents induce a hair follicle vascular injury. As hair growth is associated with micro-vessel regeneration, we postulated that the stimulation of angiogenesis might enhance hair regeneration. In particular, mice treated with 5-fluorouracil (5-FU) showed delayed anagen initiation and reduced capillary density when compared with untreated controls, suggesting that the retardation of anagen initiation by 5-FU treatment may be attributed to the loss of perifollicular micro-vessels. We investigated whether the ETS transcription factor ETV2 (aka ER71), critical for vascular development and regeneration, can promote angiogenesis and hair regrowth in a 5-FU-induced alopecia mouse model. Tie2-Cre; Etv2 conditional knockout (CKO) mice, which lack Etv2 in endothelial cells, presented similar hair regrowth rates as the control mice after depilation. Following 5-FU treatment, Tie2-Cre; Etv2 CKO mice revealed a significant reduction in capillary density, anagen induction, and hair restoration when compared with controls. Mice receiving lentiviral Etv2 injection after 5-FU treatment showed significantly improved anagen induction and hair regrowth. Two-photon laser scanning microscopy revealed that enforced Etv2 expression restored normal vessel morphology after 5-FU mediated vessel injury. Our data suggest that vessel regeneration strategies may improve hair regrowth after chemotherapeutic treatment.

3차원 안면자동인식기(3D-AFRA)의 안면 표준점 인식 정확도 검증 (Point Recognition Precision Test of 3D Automatic Face Recognition Apparatus(3D-AFRA))

  • 석재화;조경래;조용범;유정희;곽창규;황민우;고병희;김종원;김규곤;이의주
    • 사상체질의학회지
    • /
    • 제19권1호
    • /
    • pp.50-59
    • /
    • 2007
  • 1. Objectives The Face is an important standard for the classification of Sasang Contitutions. Now We are developing 3D Automatic Face Recognition Apparatus to analyse the facial characteristics. This apparatus show us 3D image of man's face and measure facial figure. We should examine accuracy of position recognition in 3D Automatic Face Recognition Apparatus(3D-AFRA). 2. Methods We took a photograph of Face status with Land Mark by using 3D-AFRA. And We scanned Face status by using laser scanner(vivid 700). We analysed error average of distance between Facial Definition Points. We compare the average between using 3D-AFRA and using laser scanner. So We examined the accuracy of position recognition in 3D-AFRA at indirectly. 3. Results and Conclusions The error average of distance between Right Pupil and The Other Facial Definition Points is 0.5140mm and the error average of distance between Left Pupil and The Other Facial Definition Points is 0.5949mm in frontal image of face. The error average of distance between Left Pupil and The Other Facial Definition Points is 0.5308mm and the error average of distance between Left Tragion and The Other Facial Definition Points is 0.6529mm in laterall image of face. In conclusion, We assessed that accuracy of position recognition in 3D-AFRA is considerably good.

  • PDF

전산화 단층촬영 모의치료기 정도관리 팬텀의 유용성 평가 (Efficiency Evaluation of CT Simulator QA Phantom)

  • 황세하;민제순;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제21권2호
    • /
    • pp.89-95
    • /
    • 2009
  • 목 적: 전산화단층촬영 모의치료기의 일일 정도 관리를 편리하고 신속하게 시행 할 수 있는 팬텀을 제작하여 유용성을 평가한다. 대상 및 방법: 폴리스타일렌 팬텀($250{\times}250{\times}100\;mm$)에 영상에서의 측정치와 실측정치의 정확성 확인을 위하여 홈($1{\times}100{\times}1\;mm$)을 만들었으며 테이블 이동의 정확성 평가를 위하여 중심부에서 위와 아래쪽 100 mm 지점에 직경 1 mm 크기의 홈을 만들어 방사선 비 투과 물질을 삽입하였다. 레이저의 정확성 평가를 위하여 팬텀 좌, 우측 수직선상에 십자 표시를 하였고 CT Number의 정확성 평가를 위하여 직경 25 mm, 깊이 50 mm의 원기둥 3개를 만들어 뼈 등가물질, 물, 공기를 삽입하였다. 제작한 팬텀을 전산화단층촬영 모의치료기(Brilliance BigBore, Philips, Netherlands)를 사용하여 촬영한 후(촬영조건 120 KVp, 100 mAs, 단면 두께 1 mm 연속촬영) 영상을 이용하여 측정치와 실측정치의 정확성, 테이블 이동, 레이저, CT Number의 정확성을 평가 하였다. 결 과: 제작한 팬텀을 이용하여 2008년 1월 7일부터 3월 7일까지 약 2개월 동안 본원에 설치되어 있는 전산화단층촬영 모의 치료기의 일일 정도관리에 사용해 본 결과 영상에서의 측정치와 실측정치의 정확성은 ${\pm}0.3\;mm$, 테이블 이동의 정확성은 ${\pm}0.3\;mm$, 레이저 정확성은 ${\pm}0.5\;mm$로 기준치인 ${\pm}1\;mm$ 오차범위 이내로 측정 되었으며 CT Number의 정확성 평가에서 뼈 등가 물질은 ${\pm}8\;HU$, 공기는 ${\pm}5\;$, 물은 ${\pm}5\;HU$로 기준치인 ${\pm}10\;HU$ 오차범위 이내로 측정되었다. 결 론: 본원에서 제작한 팬텀의 이용으로 신속하고 간편하게 레이저 장치의 정확성과 전산화단층촬영 모의치료기의 성능평가를 동시에 시행 할 수 있었으며 기존에 실시하던 일일 정도관리 항목에 영상을 이용한 평가 항목을 추가 보완함으로서 보다 정확한 치료 계획 과정을 수립 할 수 있을 것으로 사료된다.

  • PDF