• Title/Summary/Keyword: large-scale test

Search Result 1,428, Processing Time 0.031 seconds

A Noise Control of Cooler Housing in Large Scale Vertical Motor (대형 수직전동기 Cooler Housing의 이상소음 제어)

  • Joo, W.H.;Kim, D.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.132-137
    • /
    • 2000
  • Recently, a severe noise problem was encountered during a shop test of large scale vertical motor. In order to identify the noise characteristics and propose the countermeasure, a variety of experiments such as sound excitation test and contribution analysis was earned out in addition to ordinary noise and vibration measurements. The results showed that the severe noise level was dominated by an acoustic resonance phenonmenon in the cooler housing and higher sound power of outer fan. Through proper treatments, the noise level could be acceptable.

  • PDF

Analysis of Stress Behavior on Field Welded Joints of U-rib in Steel Bridge (U리브 현장용접이음부 응력거동에 관한 연구)

  • Kang, Chang Ib;Choi, Seong Min;Kook, Seung Kyu;Lee, Dong Uk
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.3 s.70
    • /
    • pp.387-396
    • /
    • 2004
  • In this paper, stress analysis anda 3-point bending fatigue test were conducted on the full-scale specimen to investigate the effects of misalignment at the U-rib welded joint due to misfitting in the steel deck bridge. In addition, the researchers investigated the direction and starting point of fatigue cracks by SEM (Scanning Electron Microscope) and beach mark. The results of the stress analysis show that maximum stress occurred at the bottom corner of the U-rib, and that the stress was large when the magnitude of the misalignment was large. On the other hand, the results of the static loading test of the full-scale specimen show that stress was large at the bottom corner of the U-rib. In addition, fatigue life was short when the misalignment was large and fatigue life was short when the misalignment was large and fatigue life was short when the misalignment was large and fatigue life was large when the misalignment was small, as indicated by the results of both the static loading test and the fatigue test. From the observation of the failure surface, fatigue cracks began manifesting at the root of the base metal and proceeded to the bead surface (weld toe).

Multi-factor Evolution for Large-scale Multi-objective Cloud Task Scheduling

  • Tianhao Zhao;Linjie Wu;Di Wu;Jianwei Li;Zhihua Cui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.4
    • /
    • pp.1100-1122
    • /
    • 2023
  • Scheduling user-submitted cloud tasks to the appropriate virtual machine (VM) in cloud computing is critical for cloud providers. However, as the demand for cloud resources from user tasks continues to grow, current evolutionary algorithms (EAs) cannot satisfy the optimal solution of large-scale cloud task scheduling problems. In this paper, we first construct a large- scale multi-objective cloud task problem considering the time and cost functions. Second, a multi-objective optimization algorithm based on multi-factor optimization (MFO) is proposed to solve the established problem. This algorithm solves by decomposing the large-scale optimization problem into multiple optimization subproblems. This reduces the computational burden of the algorithm. Later, the introduction of the MFO strategy provides the algorithm with a parallel evolutionary paradigm for multiple subpopulations of implicit knowledge transfer. Finally, simulation experiments and comparisons are performed on a large-scale task scheduling test set on the CloudSim platform. Experimental results show that our algorithm can obtain the best scheduling solution while maintaining good results of the objective function compared with other optimization algorithms.

Characteristics of Resilient Modulus of Reinforced-Roadbed Materials Using Large Repetitive Triaxial Test (대형반복삼축시험에 의한 강화노반 재료의 회복탄성계수 특성 분석)

  • Lim, Yu-Jin;Lee, Jin-Ug;Hwang, Jung-Kyu;Park, Mi-Yun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1115-1122
    • /
    • 2011
  • Reinforced-Roadbed materials are usually composed of crushed stones. Repeated load application can induce deformation in the reinforced-roadbed layer so that it causes irregularity of track. Thus it is important to develop a prediction model of elastic modulus based on stress-strain relation under repeatitive load in order to investigate behavior of reinforced roadbed. The prediction model of elastic modulus of the material can be obtained from repeated triaxial test. However, a proper size of the sample for the test must be used. In this study, a large repeatitive triaxial test apparatus with the sample size of diameter of 30 cm and height of 60cm was adapted for performing test of the crushed stone reinforced-roadbed considering large particle size to get resilient modulus Mr. The obtained resilient modulus was compared to shear modulus obtained from mid size resonant column test. The sample size effect is somewhat large enough so that it is required to design a scale factor based on similarity law in order to use smaller samples for getting elastic modulus of the crushed stone reinforced-roadbed material. A scale factor could be obtained from this study.

  • PDF

An empirical study of the effectiveness of spatial navigation system - Focus on large-scale web sites - (공간 지식을 적용한 항해 시스템에 관한 연구 - 대규모 웹 사이트를 중심으로 -)

  • Suh, Jin-Won;Kim, Jin-Woo
    • Asia pacific journal of information systems
    • /
    • v.11 no.2
    • /
    • pp.79-98
    • /
    • 2001
  • As the average size of web sites gets larger, users tend to experience more severe problems while navigating through the sites. In order to alleviate the navigation-related problems, this paper proposes two new navigation systems based on the spatial metaphor to the navigation in the real world. Prototypes of the two system, Complete Route Navigation(CRN) and Complete Survey Navigation(CSN), were developed and applied to four versions of test bed web sites, which were then used in an experiment to test the effectiveness of the two navigation systems. Results from the experiment indicate that the two systems are indeed effective in aiding users to navigate in a large scale web site, and have more positive impacts when provided together. This paper ends with the limits of the study results and their implications to the development of large-scale web sites.

  • PDF

Geocomat를 활용한 폐기물매립장의 사면안정성 검토

  • 신은철;이성근;이영재
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.06a
    • /
    • pp.45-54
    • /
    • 2001
  • In this study, slope stability analysis of LCRS(Leachate Collection Removel System) in waste landfill was peformed by large scale field test. Geocomat is new type of geocomposite product. Gecomat is a sort of Geocomposite product. It is composed of nonwoven geotextiles, woven geotextile, and geonet. Large scale field tests were performed on the slope of different two LCRSsections with static loading condition. One is LCRS section witch consist of GCL, HDPE and Geocomat, another is GCL, HDPE, and woven type geocomposite. The behavior of geosynthetics lined slope was monitored by incorporating instrumentation including vertical soil pressure meter, settlement plate, strain gauges, potential meter, displacement pin.. Based on the field monitoring, the Geocomat LCRS section is less sliding than the conventional geocomposite LCRS section.

  • PDF

The Fluid Loss and Sealing Mechanisms in Slurry Trench Condition (I) : A Large Scale Test and Design Procedure (Slurry wall 공법에서 안정액의 역할 (I) : 대형모형실험과 설계절차)

  • Kim, Hak-Moon
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.239-248
    • /
    • 2002
  • Bentonite slurries in a slurry wall construction must fulfill a stabilizing function by forming impermeable membrane (surface cake and penetrated cake) on the excavated soil faces. Thus problems are occurring in practice for the construction of diaphram walls and cut-off walls with a low permeability for wastes disposal areas in some deep excavations or different grounds. In this paper, the fundamental mechanics of fluid loss and filter cake formation in various soil beds are investigated using large scale laboratory apparatus. The sealing efficiency of filter cake from the large scale tests and the significance of fluid loss in a slurry trench are utilized for practical situation as a recommended design procedure.

Migration of fine granular materials into overlying layers using a modified large-scale triaxial system

  • Tan Manh Do;Jan Laue;Hans Mattsson;Qi Jia
    • Geomechanics and Engineering
    • /
    • v.37 no.4
    • /
    • pp.359-370
    • /
    • 2024
  • The primary goal of this study is to evaluate the migration of fine granular materials into overlying layers under cyclic loading using a modified large-scale triaxial system as a physical model test. Samples prepared for the modified large-scale triaxial system comprised a 60 mm thick gravel layer overlying a 120 mm thick subgrade layer, which could be either tailings or railway sand. A quantitative analysis of the migration of fine granular materials was based on the mass percentage and grain size of migrated materials collected in the gravel. In addition, the cyclic characteristics, i.e., accumulated axial strain and excess pore water pressure, were evaluated. As a result, the total migration rate of the railway sand sample was found to be small. However, the total migration rate of the sample containing tailings in the subgrade layer was much higher than that of the railway sand sample. In addition, the migration analysis revealed that finer tailings particles tended to be migrated into the upper gravel layer easier than coarser tailings particles under cyclic loading. This could be involved in significant increases in excess pore water pressure at the last cycles of the physical model test.

EVALUATION OF SHEAR BEHAVIOR OF LARGE GRANULAR MATERIALS WITH DIFFERENT PARTICLE SIZES BY TRIAXIAL TEST AND NUMERICAL SIMULATION

  • Kim, Bum-Joo;Sagong, Myung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09c
    • /
    • pp.55-60
    • /
    • 2010
  • Rockfill zones in CFRD consist typically of large granular materials, usually the maximum particle size up to several meters, which makes laboratory testing to determine the mechanical properties of rockfill difficult. Commonly, the design strength of the rockfills is obtained by scaling down the original rockfill materials and performing laboratory strength tests for the reduced size materials. The objective of the present study is to investigate the effect of particle size on the shear behavior and the strength for granular materials. A series of large-scale triaxial tests was conducted on large granular materials with the maximum particle size varying from 20 to 50mm. The test results showed that overall shear behaviors were similar between the samples with different particle sizes while there were slight differences in the magnitudes of the peak shear stress between the samples. In addition, a simulation of the granular material with the max. particle size of 20mm was performed using DEM code, $PFC^{2D}$, and compared with the test results. The deviatoric stress versus strain behaviors of experimental and numerical tests were found to be matched well up to the peak stress state.

  • PDF

A Test System of Valve and Poles for Large Scale Inverter using Resonant Circuit (공진회로를 이용한 대용량 인버터 구성용 밸브 및 폴 시험설비에 관한 연구)

  • Han, Young-Seong;Chung, Chung-Choo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.971-976
    • /
    • 2011
  • This paper proposes a test system for a valve and poles building blocks used for large scale inverters such as STATCOM, SSSC, UPFC and VSC HVDC. Power semiconductors in the valve are normally connected in series to withstand switching voltage much larger than the voltage rating of a single power semiconductor. Therefore, there is a need to verify if the dynamic voltage sharing during switching in a valve is satisfactory. In this paper, we propose a test system that provides the necessary test condition: voltage and current in the valve using resonant circuits. A test scheme for a single phase inverter consisting two poles is also proposed. The performance of the inverter pole has to be verified at the factory test, before the system is installed at the site to secure the reliability of the system. The proposed scheme makes it possible to confirm if the pole can withstand voltage and current switching condition and handle loss.