• Title/Summary/Keyword: large scale testing

Search Result 230, Processing Time 0.024 seconds

Analysis of Failutr Count Data Based on NHPP Models (NHPP모형에 기초한 고장 수 자료의 분석)

  • Kim, Seong-Hui;Jeong, Hyang-Suk;Kim, Yeong-Sun;Park, Jung-Yang
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.2
    • /
    • pp.395-400
    • /
    • 1997
  • An important quality characteristic of a software reliability.Software reliablilty growh models prvied the tools to evluate and moniter the reliabolty growth behavior of the sofwate during the testing phase Therefore failure data collected during the testing phase should be continmuosly analyzed on the basis of some selected software reliability growth models.For the cases where nonhomogeneous Poisson proxess models are the candiate models,we suggest Poisson regression model, which expresses the relationship between the expeted and actual failures counts in disjonint time intervals,for analyzing the failure count data.The weighted lest squares method is then used to-estimate the paramethers in the parameters in the model:The resulting estimators are equivalent to the maximum likelihood estimators. The method is illustrated by analyzing the failutr count data gathered from a large- scale switchong system.

  • PDF

Test Suites Generation Method in Consideration of Data Flow (자료흐름을 고려한 테스트 스위트 생성기법)

  • Kim, Yong-Seung;Woo, Sung-Hee;Oh, Byeong-Ho;Lee, Sang-Ho
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.8
    • /
    • pp.1975-1986
    • /
    • 1997
  • Recent evolution of communication networks has led toward increasingly a complex, large-scale protocol. Protocol conformance tests therefore, which consider only control flow, have many problems on testing data flow, transition condition, delay and so on. We propose, design, and implement the tool to solve these problems. The tool, which solves nondeterminism, generates test suites from an integrated flow graph and excludes infeasible path with reachable tree. The presented tool reduces the length of UIO sequence and is efficient partially to test the path that error rate is high. Our automatic test suite generator provides basis of protocol testing environment and high production.

  • PDF

Estimation on Discharge Capacity of Prefabricated Vortical Drains Considering Influence Factors (영향인자를 고려한 연직배수재의 통수능 평가)

  • Shin Eun-Chul;Park Jeong-Jun;Kim Jong-In
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.9
    • /
    • pp.13-23
    • /
    • 2005
  • The prefabricated vertical drains (PVDs) are one of the most widely used techniques to accelerate the consolidation of soft clay deposits and dredged soil. Discharge capacity is one of the factors affecting the behavior of PVDs. In the field, a PVD is confined by clay or dredged soil, which is normally remolded during PVD installation. Under field conditions, soil particles may enter the PVD drainage channels, and the consolidation settlement of the improved subsoil may cause 131ding of the PVD. These factors will affect the discharge capacity of the PVDs. In this study an experimental study was carried out to estimate the discharge capacity of three different types of PVDs by utilizing the large-scale laboratory model testing and small-scale laboratory model testing equipments. The several factors such as confinement condition (confined by soft marine clay or dredged soil) and variations of the discharge capacity were studied with time under soil specimen confinement, The test results indicated that discharge capacity decreases with increasing load, time, and hydraulic gradient. With load application, the cross-sectional area of the drainage channel of PVD decreases because the filter of PVD is pressed into the core. The discharge capacity of the soft marine clay-confined PVDs is much lower than that of the dredged soil-confined PVDs.

Performance Evaluation of Paving Blocks Based Ambient Temperature Reduction Using a Climatic Environment Chamber (기후환경챔버를 활용한 블록의 공기온도 저감 성능평가)

  • Ko, Jong Hwan;Park, Dae Geun;Kim, Yong Gil;Kim, Sang Rae
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.4
    • /
    • pp.187-192
    • /
    • 2017
  • This study evaluated the reduction performance of ambient temperature and the amount of evaporation that takes place depends on the temperature difference of paving blocks which are used in the sidewalk, roadway, parking lot, park, plaza, and etc. The water-retentive block of the LID (Low Impact Development) practice was compared with the conventional concrete block. For the quantitative performance evaluation, experiments were performed in a climatic environment chamber capable of controlling the climatic environment (solar radiation, temperature, humidity, rainfall, and snowfall). The method for performance evaluation was proposed using temperature, humidity, and ambient air of paving blocks which changes according to the solar radiation and the wind speed after the rainfall. As a result, the evaporation amount of the water-retentive block was 2.6 times higher than that of the concrete block, the surface temperature of water-retentive block was $10^{\circ}C$ lower than the concrete block, and the air temperature of water-retentive block was $4.6^{\circ}C$ lower than the concrete block. Therefore, it is analyzed that the water-retentive block with a large amount of evaporation is more effective in reducing the urban heat island phenomenon as compared with the concrete block.

Comparative study on the O/D estimation using Gradient method and Generalized Least Square method (Gradient방법과 일반화최소자승법을 이용한 관측교통량기반 O/D 추정방법에 관한 예측력 비교평가 연구)

  • 이승재;김종형
    • Journal of Korean Society of Transportation
    • /
    • v.18 no.2
    • /
    • pp.41-52
    • /
    • 2000
  • In the developing country, the transportation situation is changed very quickly and the transportation environment is not stable. So the transportation planning should be frequently made in considering the limited cost and time. And the traditional large-scale survey(household survey, roadside interview, etc.) has many Problem like the difficulty for doing it and getting mood results. Therefore the study about the method of evaluation on the traffic count based O/D matrix is Processing actively recently. Though the many study for the network in the realistic size are enacted, the study for comparing with the advantage and disadvantage of each method are few. Therefore this study mainly deals with the static method among the existing models of evaluation on the traffic count based O/D matrix(in terms of the transportation plan). Bi-level(GU) and gradient method are selected as main alternative model and analyzed their capability and validity. For testing the reliability of the models, Bi-level(GLS) and gradient method are adapted to toy network. Then we analyze the result of testing, and study the way for large network.

  • PDF

Energy-saving Strategy Based on an Immunization Algorithm for Network Traffic

  • Zhao, Dongyan;Long, Keping;Wang, Dongxue;Zheng, Yichuan;Tu, Jiajing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.4
    • /
    • pp.1392-1403
    • /
    • 2015
  • The rapid development of both communication traffic and increasing optical network sizes has increased energy consumption. Traditional algorithms and strategies don't apply to controlling the expanded network. Immunization algorithms originated from the complex system theory are feasible for large-scale systems based on a scale-free network model. This paper proposes the immunization strategy for complex systems which includes random and targeted immunizations to solve energy consumption issues and uses traffic to judge the energy savings from the node immunization. The simulation results verify the effectiveness of the proposed strategy. Furthermore, this paper provides a possibility for saving energy with optical transmission networks.

Performance of Adhesives in Glulam after Short Term Fire Exposure

  • Quiquero, Hailey;Chorlton, Bronwyn;Gales, John
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.299-311
    • /
    • 2018
  • As engineered timber such as Glulam is seeing increasing use in tall timber buildings, building codes are adapting to allow for this. In order for this material to be used confidently and safely in one of these applications, there is a need to understand the effects that fire can have on an engineered timber structural member. The post-fire resilience aspect of glulam is studied herein. Two sets of experiments are performed to consider the validity of zero strength guidance with respect to short duration fire exposure on thin glulam members. Small scale samples were heated in a cone calorimeter to different fire severities. These samples illustrated significant strength loss but high variability despite controlled quantification of char layers. Large scale samples were heated locally using a controlled fuel fire in shear and moment locations along the length of the beam respectively. Additionally, reduced cross section samples were created by mechanically carving a way an area of cross section equal to the area lost to char on the heated beams. All of the samples were then loaded to failure in four-point (laterally restrained) bending tests. The beams that have been burnt in the shear region were observed as having a reduction in strength of up to 34.5% from the control beams. These test samples displayed relatively little variability, apart from beams that displayed material defects. The suite of testing indicated that zero strength guidance may be under conservative and may require increasing from 7 mm up to as much as 23 mm.

Testing Gravity with Cosmic Shear Data from the Deep Lens Survey

  • Sabiu, Cristiano G.;Yoon, Mijin;Jee, Myungkook James
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.40.4-41
    • /
    • 2018
  • The current 'standard model' of cosmology provides a minimal theoretical framework that can explain the gaussian, nearly scale-invariant density perturbations observed in the CMB to the late time clustering of galaxies. However accepting this framework, requires that we include within our cosmic inventory a vacuum energy that is ~122 orders of magnitude lower than Quantum Mechanical predictions, or alternatively a new scalar field (dark energy) that has negative pressure. An alternative approach to adding extra components to the Universe would be to modify the equations of Gravity. Although GR is supported by many current observations there are still alternative models that can be considered. Recently there have been many works attempting to test for modified gravity using the large scale clustering of galaxies, ISW, cluster abundance, RSD, 21cm observations, and weak lensing. In this work, we compare various modified gravity models using cosmic shear data from the Deep Lens Survey as well as data from CMB, SNe Ia, and BAO. We use the Bayesian Evidence to quantify the comparison robustly, which naturally penalizes complex models with weak data support. In this talk we present our methodology and preliminary results that show f(R) gravity is mildly disfavoured by the data.

  • PDF

Evaluation of the seismic performance of butt-fusion joint in large diameter polyethylene pipelines by full-scale shaking table test

  • Jianfeng Shi;Ying Feng;Yangji Tao;Weican Guo;Riwu Yao;Jinyang Zheng
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3342-3351
    • /
    • 2023
  • High-density polyethylene (HDPE) pipelines in nuclear power plants (NPPs) have to meet high requirements for seismic performance. HDPE pipes have been proved to have good seismic performance, but joints are the weak links in the pipelines, and pipeline failures usually initiate from the defects inside the joints. Limited data are available on the seismic performance of butt-fusion joints of HDPE pipelines in NPPs, especially in terms of defects changes inside the joints after earthquakes. In this paper, full-scale shaking table tests were performed on a test section of suspended HDPE pipelines in an NPP, which included straight pipes, elbows, and 10 butt-fusion joints. During the tests, the seismic load-induced strain of the joints was analyzed by strain gauges, and it was much smaller than the internal pressure and self-weight-induced strain. Before and after the shaking table tests, phased array ultrasonic testing (PA-UT) was conducted to detect defects inside the joints. The locations, numbers, and dimensions of the defects were analyzed. It was found that defects were more likely to occur in elbows joints. No new defect was observed after the shaking table tests, and the defects showed no significant growth, indicating the satisfactory seismic performance of the butt-fusion joints.

Structural performance of unprotected concrete-filled steel hollow sections in fire: A review and meta-analysis of available test data

  • Rush, David;Bisby, Luke;Jowsey, Allan;Melandinos, Athan;Lane, Barbara
    • Steel and Composite Structures
    • /
    • v.12 no.4
    • /
    • pp.325-350
    • /
    • 2012
  • Concrete filled steel hollow structural sections (CFSs) are an efficient, sustainable, and attractive option for both ambient temperature and fire resistance design of columns in multi-storey buildings and are becoming increasingly common in modern construction practice around the world. Whilst the design of these sections at ambient temperatures is reasonably well understood, and models to predict the strength and failure modes of these elements at ambient temperatures correlate well with observations from tests, this appears not to be true in the case of fire resistant design. This paper reviews available data from furnace tests on CFS columns and assesses the statistical confidence in available fire resistance design models/approaches used in North America and Europe. This is done using a meta-analysis comparing the available experimental data from large-scale standard fire tests performed around the world against fire resistance predictions from design codes. It is shown that available design approaches carry a very large uncertainty of prediction, suggesting that they fail to properly account for fundamental aspects of the underlying thermal response and/or structural mechanics during fire. Current North American fire resistance design approaches for CFS columns are shown to be considerably less conservative, on average, than those used in Europe.